• 제목/요약/키워드: 콘크리트 콘 파괴

검색결과 21건 처리시간 0.022초

Evaluation of Concrete Cone Breakout Strength of Expansion Anchors (익스팬션 앵커의 콘크리트 콘 파괴강도 평가)

  • Kim, Sung Yong;Kim, Kyu Suk
    • Journal of Korean Society of Steel Construction
    • /
    • 제15권6호통권67호
    • /
    • pp.649-660
    • /
    • 2003
  • The paper presents an evaluation of the tensile strength of the expansion anchor that can cause failure in the concrete based on the design of the anchorage. Tests of the heavy-duty anchor and the wedge anchor that are domestically manufactured and installed in plain concrete members are conducted to probe the effects of the embedded depth, concrete strength, and anchors spacing. The design of post-installed steel anchors is presented using the Concrete Capacity Design (CCD) approach. The CCD method is applied to predict the concrete failure load of the expansion anchor in plain concrete under monotonic loading for important applications. The concrete tension capacity of the fastenings with heavy-duty anchors and wedge anchors in plain concrete predicted using the CCD method is compared with the test results. For the CCD method, a normalization coefficient of 9.94 is appropriale for the nominal concrete breakout strength of an anchor or a group of wedge anchors in tension. On the other hand, a normalization coefficient of 11.50 is appropriate for the nominal concrete breakout strength of an anchor or a group of heavy-duty anchors in tension.

A Study on the Fracture Resistance Characteristics of Post-Installed Anchor (후설치 앵커볼트의 파괴저항 특성에 관한 연구)

  • Kim, Doo Hwan;Hwang, Yun Sung;Cha, Young Min;Song, Kwan Kwon;Choi, Kyung Gyp
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2011년도 정기 학술발표대회
    • /
    • pp.156-156
    • /
    • 2011
  • 중량물 혹은 철골구조물 등을 고정시키는데, 건축구조물의 철골기둥, 터빈 제네레이터 기기등을 콘크리트 구조물에 부착시키기 위해 널리 쓰인다. 1990년대 들어 국내 건물의 리모델링, 보수 및 유지관리의 증가에 따라 앵커의 사용량도 현저히 증가하고 있으나 대부분 고가의 외국산제품을 수입하고 있다. 현재 국내외에 주로 시행되는 앵커타입은 마찰형 앵커이나 마찰형 앵커와 달리 지압형 앵커의 경우, 외국에서는 이미 그 유효성에 대한 인식이 널리 퍼져있으며 각국의 지반조건에 적합한 설계법이 개발되었다. 그러나 국내의 경우 이러한 연구가 미진한 실정이며 이에 대한 연구가 절실한 상황이다. 본 연구에서는 중량물앵커(Heavy Duty Anchor)의 인장시험을 실시하여 내력을 규명하고 도출한 결과를 기존 시험연구 결과와 비교분석하여 기 제안된 이론식들과 사업경제성에대해 보다 깊이있고 정확한 적용성을 입증하는데 본 연구를 수행하였다. 시험을 통한 저강도 파괴시험의 결과 구조부재의 접합부에서 각 시험체마다 뽑힘파괴가 발생하였으며, 뽑힘파괴가 발생한 시험체는 앵커강재의 파괴력 또는 콘크리트의 콘파괴를 발생시키기에는 앵커슬리브의 확장력이 작게 작용되었다. 그 결과, 콘파괴 대신 구조부재의 접합부에서 뽑힘파괴가 발생되었으며 이를 통해 설계시, 앵커의 안정성을 증가시키기 위해 구조부재의 접합부를 연성적이며, 부가여력을 충분히 지니도록 설계하는 것이 효과적인 것으로 나타났다. 고강도 파괴시험의 결과 콘파괴가 발생되었음을 알 수 있는데, 본 시험에 사용된 앵커의 경우 정착위치가 구조물의 연단 모서리 거리와 너무 근접하여 앵커의 내력이 감소하게 되어 콘크리트의 콘강도가 발생되기 전에 먼저 파괴되었다. 따라서 설계시, 앵커의 파괴강도를 증가시키기 위해 앵커의 정착위치를 고려한 설치를 통해 앵커체결과정에서 적정 연단거리를 확보하는 것이 효과적인 것으로 나타났다. 앵커볼트 최소간격과 연단거리에 따른 파괴시험결과 앵커볼트의 간격이 허용범위 내에서 넓어질수록 불균등 부반력의 차는 감소하였으며, 최대 부반력도 감소하였다. 따라서 앵커의 파괴저항강도를 증가시키기 위해서는 허용범위 내에서 앵커볼트의 설치간격을 증가시키는 것이 효과적인 것으로 나타났다.

  • PDF

An Experimental Study on Pullout Characteristics of Post-installed Set Anchor for Concrete under Edge Distance, Anchor Interval and Concrete Strength (연단거리, 앵커간격 및 콘크리트 강도에 따른 콘크리트용 후설치 세트앵커의 인발특성에 관한 실험적 연구)

  • Suth, Ratha;Yoo, Seung-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제15권4호
    • /
    • pp.2469-2475
    • /
    • 2014
  • In 1990s, with the increase of domestic building renovation but also increase the amount of anchor. The 45-degree cone failure theory has been used in concrete anchor bolts design, but the CCD (concrete capacity design) method was adopted as a new design method since 2000. However, the method has some problems because it is based on the experimental results of pre-installed concrete anchor bolts. In this study, the objective is to investigate the effects of anchor edge distance, anchor interval and concrete strength on pullout characteristics of post-installed concrete set anchor embedded in plain concrete.

A Study on the Concrete Breakout Capacity of CIP Anchor Bolts under Shear Loading (전단력을 받는 선설치 앵커볼트의 콘크리트 파열파괴강도 평가 연구)

  • Park, Yong-Myung;Jeon, Myeong-Hui;Choi, Myung-Kuk;Kim, Cheol-Hwan;Kim, In-Gi
    • Journal of Korean Society of Steel Construction
    • /
    • 제24권2호
    • /
    • pp.207-215
    • /
    • 2012
  • The 45-degree cone failure theory has been used in concrete anchor bolts design under shear loading, but the CCD (Concrete Capacity Design) method was adopted as a new design method since 2000. However, the method was allowed only for anchor diameters of less than 50mm because it is based on the experimental results of small size anchor bolts. Therefore, it is necessary to develop a rational concrete breakout capacity equation for medium-to-large size anchor bolts with large edge distance. In this study, shear tests on M56 cast-in-place single anchor bolt with edge distance of 350mm were performed using four test specimens. Based on the test results and findings of existing studies, a new equation for the breakout capacity of anchor bolts under shear loading with edge distance of up to 750mm was proposed.

A Study on the Concrete Breakout Capacity Evaluation of Medium-to-Large size CIP Anchor Bolts under Tension Loading (인장하중을 받는 중대형급 선설치 앵커볼트의 콘크리트파괴강도 평가를 위한 연구)

  • Park, Yong-Myung;Jeon, Myeong-Hui;Lee, Kun-Jun;Kim, Cheol-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • 제23권4호
    • /
    • pp.493-501
    • /
    • 2011
  • The $45^{\circ}$cone failure theory has been used for concrete anchor bolt design, but the CCD (concrete capacity design) method was adopted as a new design method in 2000. The method was allowed to be used, however, only for anchors with a diameter of less than 50 mm and an embedment depth of less than 635 mm because it is based on the experiment results from medium-sized to small anchor bolts. Therefore, it is necessary to develop a rational concrete breakout capacity equation for medium-sized to large anchor bolts. In this study, tension tests on an M56 cast-in-place single anchor bolt with an effective embedment depth of 400-450 mm were carried out for the five test specimens. Based on the test results together with the other recent test results, the applicability of the concrete breakout capacity equation in the current design code to the large to medium-sized anchor bolts with an embedment depth of 280-1,200 mm was estimated.

A Study on Characteristics of Flexural Behavior of High-strength Polymer Concrete Beams Using Recycled PET (PET 재활용 고강도 폴리머 콘크리트보의 휨거동에 관한 연구)

  • Cho Byung-Wan;Park Jong-Hwa;Park Seung-Kook;Bea Sung-Wan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.483-486
    • /
    • 2005
  • The polymer concrete is drawing a strong interest as high-performance materials in the construction industry. Resins using recycled PET offer the possibility of a lower source cost of materials for making useful polymer concrete products. Also the recycling of PET in polymer concrete would help solve some of the solid waste problems posed by plastics and save energy. Polymer concrete beams using unsaturated polyester resins based on recycled polyethylene terephthalate (PET) plastic waste were used in our study for grasping its structural behavior of static and fatigue. As a result of static test, Compression stress distribution of Polymer concrete indicates linear behavior such as triangles. Although polymer concrete is high strength materials, its ductility capacity is excellent. From the fatigue test results, There was almost no difference on flexural characteristics between before and after fatigue loading. Therefore, recycled PET polymer concrete remains excellent structural ability after fatigue loading.

  • PDF

Reliability of RC Beams Designed for Flexure (철근콘크리트 휨부재의 신뢰성)

  • M.B크라코프스키;박순규
    • Magazine of the Korea Concrete Institute
    • /
    • 제7권3호
    • /
    • pp.164-174
    • /
    • 1995
  • Reliability of RC beanls designed for flexure under the provisions of ACI Building Code is analyzed. The results are compared with those obtained previously. It is shown that in some cases the reliability is inadequate and changes substantiallv with reinforcernent ratio. The probability of brittle failure appears to be rather high. The reasons for these phenomena are revealed and some measures to remedy the situation are recommentied. hluch attention is given to the conditions askthey stand at present in Korea.

Effect of Cutting Off Tension Bars in R/C Beams On the Full Scale and Model Specimens (철근콘트리트 보에서 체단된 철근의 효과에 관한 연구 실물 및 축소모형실험을 중심으로)

  • 이리형;최창식;임재형
    • Magazine of the Korea Concrete Institute
    • /
    • 제2권1호
    • /
    • pp.79-90
    • /
    • 1990
  • The purpose of this paper is to study on the effect of cutting off tension bars in reinforced concrete beams. that is, the ultimate strength, the failure mode and thl} tension stress distribution through the span. To achieve this purpose, a full-scale frame and seven small scale model beams (five rectangular and two T-section beams) were tested. The four main model specimens and two speciml}ns without cutting off tension bars 1,'{ere analyzed as plane stmss element with package program ADINA. As a result of test and analysis, the shorter' distance bet ween the reaction point and the cutting off point, the higher the ultimate strength of a bl}am will be when other physical properties are equal.

Generalized Analysis of RC and PT Flat Plates Using Limit State Model (한계상태모델을 이용한 철근콘크리트와 포스트텐션 무량판의 통합해석)

  • Kang, Thomas H.K.;Rha, Chang-Soon
    • Journal of the Korea Concrete Institute
    • /
    • 제21권5호
    • /
    • pp.599-609
    • /
    • 2009
  • This paper discusses generalized modeling schemes for both reinforced concrete (RC) and post-tensioned (PT) flat plate buildings. In this modeling approach, nonlinear behavior due to slab flexure, moment and shear transfer at slab-column connections, and punching shear was included along with linear secant stiffness of each member or connection that accounts for concrete cracking. This generalized model was capable of simulating all different scenarios of slab-column connection failures such as brittle punching, flexure-shear interactive failure, and flexural failure followed by drift-induced punching. Furthermore, automatic detection of drift-induced punching shear and subsequent backbone curve modifications were realistically modelled by incorporating the limit state model, in which gravity shear versus drift capacity relations were adopted. The validation of the model was conducted using one-third scale two-story by two-bay RC and PT flat plate frames. The comparisons revealed that the model was robust and effective.

Flexural Behavior of Concrete Beams Reinforced with GFRP Bars (GFRP 보강근을 사용한 콘크리트 보의 휨파괴 거동)

  • Eo, Seok-Hong;Ha, Sang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제15권8호
    • /
    • pp.5318-5326
    • /
    • 2014
  • This paper presents the results of flexural test of concrete beams reinforced with GFRP and conventional steel reinforcement for comparison. The beams were tested under a static load to examine the effects of the reinforcement ratio and compressive strength of concrete on cracking, deflection, ultimate capacity, and modes of failure. The test results showed that the ultimate capacity of the GFRP-reinforced beams increased with increasing reinforcement ratio and concrete strength, showing a 41.3~51.6% increase compared to steel reinforced beams. The deflections at maximum loads of the GFRP reinforced beams were 4.1~6.3 times higher that of steel reinforced beams. The measured deflections of GFRP reinforced beams decreased approximately 31% compared to the theoretical predictions because the theoretical flexural stiffness was underestimated at the maximum loads. For the GFRP-reinforced beams, the ACI code 440 design method resulted in conservative flexural strength estimates.