A Study on the Concrete Breakout Capacity Evaluation of Medium-to-Large size CIP Anchor Bolts under Tension Loading

인장하중을 받는 중대형급 선설치 앵커볼트의 콘크리트파괴강도 평가를 위한 연구

  • 박용명 (부산대학교 사회환경시스템공학부) ;
  • 전명희 (부산대학교 사회환경시스템공학부 대학원) ;
  • 이건준 (부산대학교 사회환경시스템공학부 대학원) ;
  • 김철환 (포스코건설 기술연구소)
  • Received : 2011.05.02
  • Accepted : 2011.07.28
  • Published : 2011.08.27

Abstract

The $45^{\circ}$cone failure theory has been used for concrete anchor bolt design, but the CCD (concrete capacity design) method was adopted as a new design method in 2000. The method was allowed to be used, however, only for anchors with a diameter of less than 50 mm and an embedment depth of less than 635 mm because it is based on the experiment results from medium-sized to small anchor bolts. Therefore, it is necessary to develop a rational concrete breakout capacity equation for medium-sized to large anchor bolts. In this study, tension tests on an M56 cast-in-place single anchor bolt with an effective embedment depth of 400-450 mm were carried out for the five test specimens. Based on the test results together with the other recent test results, the applicability of the concrete breakout capacity equation in the current design code to the large to medium-sized anchor bolts with an embedment depth of 280-1,200 mm was estimated.

콘크리트용 앵커볼트의 설계에 $45^{\circ}$ 콘파괴 이론이 그동안 적용되어 왔으나, 2,000년 이후부터 CCD(Concrete Capacity Design) 방법이 새로운 설계법으로 도입되었다. 그러나, 본 방법은 중소형 앵커볼트에 대한 실험 결과에 근거한 관계로 앵커볼트의 직경이 50mm 이하이고 매입깊이가 635mm 이하인 경우에만 허용되고 있다. 따라서 M50 이상의 중대형 앵커볼트에 대한 합리적인 인장파괴강도식의 도출이 필요한 실정이다. 본 연구에서는 매입깊이 400~450mm의 M56 선설치 단일 앵커볼트의 콘크리트 인장파괴강도 평가를 위해 5개의 시험체에 대해 실험을 수행하였다. 그리고, 본 실험 결과와 최근의 타 실험 결과를 종합하여 매입깊이가 280~1,200mm인 중대형급 앵커볼트에 대해 현 설계기준의 인장파괴강도식의 적용성 여부를 평가하였다.

Keywords

References

  1. 장정범, 서용표, 이종림(2003) 직매형 앵커기초의 설계기준 개선에 관한 연구, 대한토목학회논문집, 대한토목학회, 제23권, 제6A호, pp.1331-1338.
  2. 서용표, 주인수 등(2005) 원전 주요 기기 지지용 매입앵커의 거동성능 및 설계기준 수립에 대한 연구 : 최종보고서, 연구보고서, 한국수력원자력(주).
  3. 한국콘크리트학회(2007) 콘크리트구조설계기준해설 부록 IV 콘크리트용 앵커, 한국콘크리트학회, pp.462-494.
  4. ACI Committee 318 (2002) Building Code Requirements for Structural Concrete (ACI 318-02) and Commentary (ACI 318R-02); Appendix D Anchoring to Concrete, American Concrete Institute, pp.399-426.
  5. ACI Committee 318 (2008) Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary; Appendix D Anchoring to Concrete, American Concrete Institute, pp.409-438.
  6. ACI Committee 349 (1990) Code Requirements for Nuclear Safety Related Concrete Structures(ACI 349-90); Appendix B Steel Embedments, American Concrete Institute, pp.80-86.
  7. ACI Committee 349 (2001) Code Requirements for Nuclear Safety Related Concrete Structures(ACI 349-01); Appendix B Anchoring to Concrete, American Concrete Institute, pp.81-88.
  8. ASTM E 488-96 (Reapproved 2003) Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements, An American National Standards, ASTM international.
  9. Fuchs, W., Eligehausen, R., and Breen, J.E. (1995) Concrete Capacity Design(CCD) Approach for Fastenings to Concrete, ACI Structural Journal, Vol. 92, No. 6, pp.794-802.
  10. Klingner, R.E., Muratli, H., and Shirvani, M. (1999) A Technical Basis for Revision to Anchorage Criteria, NUREG CR-5563, U.S. Nuclear Regulatory Commission.
  11. Shirvani, M., Klingner, R.E., and Graves, III, H.L. (2004) Berakout Capacity of Anchors in Concrete-Part 1: Tension, ACI Structural Journal, Vol. 101, No. 6, pp.812-820.