• Title/Summary/Keyword: 콘크리트 충전 강관 기둥

Search Result 165, Processing Time 0.023 seconds

A study on strength of steel square tubular columns filled with high strength concrete under biaxial eccentric load (2축휨을 받는 고강도콘크리트충전 각형강관기둥의 내력에 관한 연구)

  • Seo, Seong Yeon;Keigo, Tsuda;Atsushi, Nakamura
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.567-576
    • /
    • 2002
  • Maximum-strength concrete-ailed steel square tubular columns were tested under concentric and biaxial eccentric load. Buckling length-section depth ratio $L_k/D$, magnitude of eccentricity e, and angle of eccentric load ${\theta}$ were selected as experimental parameters. Strength and behavior were also examined. Test results showed that the maximum strength of columns under biaxial eccentric load could be predicted using the previously proposed strength formula of columns under uniaxial eccentric load. Likewise, the behavior and maximum strength of columns could be predicted using the analysis.

An Experimental Study on the Bond Strengths for Concrete Filled Steel Tube Columns using a Push-Out Test (단순가력실험을 통한 콘크리트충전 강관기둥의 부착응력에 관한 연구)

  • Woo, Hae Sung;Kim, Jin Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.481-487
    • /
    • 2002
  • Currently, the load transfer's mechanism from a beam to a column has yet to ve clarified in a concrete filled steel tubular (CFT) structure with a connection type of an exterior diaphragm. The loads for each floor are transferred to the concrete core from a steel beam through ha contacted face between an in-filled concrete and the interior surface of a steel tube. Thus, a Push-Out test was performed to investigate the load transfer mechanism. A total of 30 samples were tested to confirm the bond stress and/or axial load distribution between a steel tube and in-filled concrete for CFT column. The main parameters considered for this study included concrete type, steel tube-shape/length, and the effect of a weld joint wit ha backing strip for a column splice. Test results were summarized to confirm load transfer behavior between a concrete and steel tube for each experimental parameter, using the analytical approach to verify experimental results.

Evaluation on Deformation Capacity of CFT Square Columns subject to Constant Axial and Cyclic Lateral Loads (일정축력과 반복 수평력을 받는 콘크리트충전 각형강관 기둥의 변형성능 평가)

  • Ji, Ku Hyun;Choi, Sung Mo;Kim, Dong Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.209-219
    • /
    • 2000
  • Concrete Filled steel Tube(CFT) Column has an excellent structural capacities in accordance with an interaction effect between the steel tube and concrete. Recently, CFT structure has been focussed on a structural system for a high-rise buildings. The purpose of this study is to evaluate a strength and deformation capacity of CFT square columns subjected to constant axial and cyclic lateral load. The test parameters are diameters to thickness ratio of steel tube, axial load ratios, concrete strengths, load applying types and whether or not filled concrete. Total sixteen specimens are fabricated to clarify the energy absorbtion capacity of CFT columns. Experimental results are summarized for maximum strength, initial stiffness and deformation capacity.

  • PDF

Analytical Study on the Fire Resistance of Internally Confined Hollow CFT Column (내부 구속 중공 CFT 기둥의 내화 성능에 대한 해석 연구)

  • Won, Deok Hee;Han, Taek Hee;Park, Jong Sup;Kim, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.5
    • /
    • pp.461-470
    • /
    • 2009
  • A column resisting axial load and seismic load is one of the main members in a structural system. The heated column by event of a fire can lose its strength and it may damage its structural system or cause the collapse of the entire structural system. In this study, the fire resistance capacity of internally confined hollow concrete filled tube (ICH CFT) column was investigated. In an ICH CFT column, the yield strength of the external tube is important as a concrete filled tube (CFT) column because the external tube confines the filled concrete and the strength of the column depends on the confined effect. A study was performed by finite element analyses considering the confined effect and material nonlinearity as the temperature changes by the fire. The hollow ratio, the thickness of the external tube, and the strength of concrete were selected as the parameters for the analyses. The analyses were performed by using a commercial FEA program (ABAQUS) and nonlinear concrete model program. The analysis results showed that the hollow ratio and the strength of concrete mainly affect the fire resisting capacity of an ICH CFT column.

Estimation of the Local Load-Carrying Capacities of CFCT Column to H-Beam Connections by Yield Line Model -With regard to the Tensile side of Beam flange- (인장측 보플랜지의 항복선 모델을 이용한 CFCT기둥-H형강보 접합부의 국부내력평가)

  • Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.3 s.36
    • /
    • pp.525-536
    • /
    • 1998
  • This paper is concerned with a theoretical study on the local load-carrying capacities of Concrete-Filled Circular Tubular(CFCT) column to H-beam connections by yield line theory. In this paper, the three cases which are assumed the yield line are involved. The first model is a simplified yield line model. The second model is modified by x and kx factors. The last one is a Morita's model. The local load-carrying capacities of CFCT column to H-beam connections has been studied both experimentally and theoretically using the yield line theory. The purpose of this paper is to suggest the basic data for developing the non-diaphragm connection.

  • PDF

Experimental Study on the Infilling Characteristics of CFT Column Infilled by Pumping-Up Below (하부압입공법에 의한 콘크리트 충전강관(CFT)기둥의 충전특성에 관한 실험적 연구)

  • Kim, Myoung Mo;Jeon, Sang Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.375-383
    • /
    • 2002
  • To evaluate the applicability of the construction method involving infilling CFT columns by pumping-up, a trial construction was done using 6 actual size test samples. The 12.8m-high test samples were similar to a four-story building scale. The pumping-up level was controlled at 12m. The test used two types of high performance concrete with $450kgf/cm^2$ standard design strength, and a concrete pump which is used domestically. The pressure changes in pipes or pump as well as the changes in concrete characteristics were measured during construction. in order to evaluate applicability. After the concrete hardened, the column was dismantled. The filled state of the concrete, concrete strength distribution according to column height, etc., were checked to evaluate the quality of the concrete, From the results, some basic data which characterize the pumping-up pressure were suggested. Also, the strength of hardened concrete as well as the filled state were proven to be acceptable ranges.

Structural Behaviour of Beam-to-Concrete Filled Steel Tube Column Pin Connections (콘크리트충전 각형강관기둥-보 핀접합부의 거동에 관한 실험적 연구)

  • Kim, Cheol-Hwan;Lee, Eun-Taik;Kim, Seong-Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.437-443
    • /
    • 2000
  • In order to clarify the behavior of beam-to-concrete filled steel tube column under cyclic loading condition, experimental studies were carried out on shear connections. Test parameters of this study are the width-to-thickness ratio and the effect on beams with or without slab and diaphragm. Test results show that the moment-rotation relationships of connections without slab are in the range of AISC regulation of pinned connections and the rotation capacity of connection is dependent upon the width-to-thickness ratio of the column.

  • PDF

Structural Characteristics of Welded Built-up Square CFT Column to Beam Connections with External Diaphragm (용접조립 각형 CFT 기둥-보 외다이아프램 접합부의 구조특성)

  • Lee, Seong Hui;Jung, Hun Mo;Kim, Dae Jung;Kim, Jin Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.711-722
    • /
    • 2008
  • Existing tube for concrete filled tubular structure is made through welding of four plates irrespective of tube thickness, so production performance is poor and special welding technique is needed to weld the internal diaphragm and through the diaphragm. Therefore, through manufacturing by cold forming development of beam to column connections that is no welding in position of stress concentration is needed. In this study the proposal of beam to column connections details and to making tube specimens by method of bending steel plates, we want to know the compositeeffect between internal anchor and concrete by processing on stress distribution and internal force evaluation of concrete filled tube beam to column connections with a variable of flange welding existence between column and beam, welding quantity between column and diaphragm, existence of concrete in tube, column with diaphragm and general column.

An Experimental Study on the Behaviours of Hollow CFT Column Subjected to Axial Load (중공 콘크리트충전 각형강관 기둥의 거동에 관한 연구 (I. 중심 압축실험))

  • Kim, Cheol-Hwan;Kim, Jong-Kil
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.69-76
    • /
    • 2006
  • Concrete Filled Steel Tube (CFT) system is advantageous because it increases the load-carrying capacity without increasing the size of column. However CFT system has many benefits, it is not applied to field generally because of its heavyweight and difficulty of concrete filling method. As a solution to these problems, we proposed concrete filled steel tube column with hollow made by factory-manufactured PC method. The hollow concrete filled steel tube system is expected to obtain the high strength and high capacity of deformation despite it is a lightweight. This study deals with mechanical properties, strength and deformation, of hollow concrete filled steel tube subjected to axial load. 9 specimens were tested to examine mechanical properties closely, and the following results were obtained: All specimens basically showed higher initial rigidity and maximum strength with increased concrete filling rate. And most specimens showed almost linear behavior until around 80% of maximum strength regardless of filling rate, it is estimated that the elastic range is up to a half of the maximum strength which is the yield strength level.

  • PDF

Eccentric Axial Load Test for Concrete-Filled Tubular Columns Encased with Precast Concrete (프리캐스트 콘크리트에 의해 피복된 콘크리트충전 강관기둥의 편심압축실험)

  • Lee, Ho Jun;Park, Hong Gun;Kim, Sung Bae;Park, Sung Soon
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • In this paper, concrete-filled steel tubular columns encased with precast reinforced concrete were studied. Four eccentrically loaded columns and a concentrically loaded column were tested to investigate the axial load-carrying capacity. The test parameters were the use of fiber reinforcement for cover concrete, eccentricity, column length, and lateral reinforcement. The maximum axial loads of the specimens agreed with the nominal strengths predicted by KBC 2009. However, in some specimens, the load carrying capacity quickly decreased after the peak strength due to spalling of the cover concrete.