• Title/Summary/Keyword: 콘크리트 열화

Search Result 428, Processing Time 0.029 seconds

Degradation of Cement Mortar with Supplementary Cementitious Materials Submerged in Various Oils (각종 유지류에 침지된 혼화재 치환 시멘트 모르타르의 열화특성)

  • Han, Cheon-Goo;Hwang, Chan-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.137-143
    • /
    • 2017
  • There has been a number of research on concrete durability. specially, as a research on chemical ingression, the research on the degradation against acid, alkali, and sulfate has been conducted. On the other hand, for the research on oils, especially, the influence of various oils on cement mortar with Supplementary Cementitious Materials(SCMs) is not sufficiently studied. hence, in this research, the degradation of cement mortar incorporated fly ash and blast furnace slag is researched when the cement mortar is submerged in various oils. For the result of experiment, as the content of fatty acid in the oils, the degradation of cement mortar with SCMs was occurred more, and the cement mortar with SCMs suffered more degradation than the ordinary portland cement regarding the oil submerging.

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment (고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.

The Corrosion Behavior of Rebar Embedded in Concrete With Chloride. (염화물 혼입에 따른 철근의 부식 거동)

  • Kim, Myung-Yu;Kim, Il-Sun;Jin, Sang-Ho;Yang, Eun-Ik;Lee, Sung-Tae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1069-1072
    • /
    • 2008
  • As embedded reinforcing suffer from corrosion process, the bond strength and stiffness are reduced, and the structure proceed, eventually, to the deterioration of the concrete, shortening the service life of concrete structures rapidly. In order to deal with these problems, a multitude of researches have been carried out up to this date to evaluate the bond characteristics of RC members, i.e. by artificially inducing rapid corrosion of the reinforcing bar. These artificial corrosion methods, however, could not represent the real condition, resulting in the possibility of overestimation for the RC members in real situation. Accordingly, the purpose of this paper is to investigate the difference in the bond characteristics for RC members corroded by different corrosion methods (artificial rapid method, natural method). For the case of natural corrosion, the brittle failure was observedeven for the case of the area ofcorrosion of 50%. And, the bond strength decreased by about 10% or more for the caseofspecimens with the area of corrosion of 80% or above. Especially, the deterioration of concrete starts at the state of low corrosion level for the case of natural corrosion. Thus, the safety of RC members must be assessed and evaluated more carefully for the naturally corroded members than for the RC concrete members corroded rapidly by artificial method.

  • PDF

Freeze-Thaw Durability and Carbonation of Concrete Surface Protecting materials (콘크리트 표면보호재 종류에 따른 동결융해 및 중성화 내구특성)

  • Lee, Beung-Duk;Kim, Hyun-Joong;Kwon, Young-Rak;Kim, Sye-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.593-596
    • /
    • 2008
  • Domestic area of most be happened chloride deicer damage. Because daily mean temperature is below 0$^{\circ}C$ from the area of domestic most. Use of deicing chemicals has been and will continue to be a major part of concrete structure in the highway. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. Extensive use of chloride deicers is, however, not only the source of substantial cost penalties due to their corrosive action and ability to deterioration roadway surface materials but also the source of environmental damages. Chloride-containing chemicals such as calcium chloride or rock salt are main deicers for the road. Extensive use of chloride deicers is, however, not only the source of substantial cost penalties due to their corrosive action and ability to deterioration roadway surface materials but also the source of environmental damages. In this study, Use of deicing chemicals has been and will continue to be a major part of highway freeze-thaw durability and carbonation of concrete surface protecting materials

  • PDF

Modeling of Chloride Ingress in Reinforced Concrete Structures (철근 콘크리트 구조물의 염소이온 침투 모델)

  • Koo, Hyun-Bon;Kim, Eui-Tae;Lee, Kwang-Myong
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.25-34
    • /
    • 2003
  • The degradation of reinforced concrete (RC) structures due to physical and chemical attacks has been a major issue in construction engineering. Deterioration of RC structures by chloride attack followed by reinforcement corrosion is one of the serious problems. An objective of this study is to develop a form of mathematical model of chloride ingress into concrete. In order to overcome some limits of the previous approaches, a chloride ingress model, consisting of chloride solution intrusion through the capillary pore and chloride ion diffusion through the pore water, was proposed. Moreover, the variability of chloride ion diffusivity due to the degree of hydration of cement, relative humidity in pore, exposure condition, and variation of chloride binding, was considered in the model. In order to verify the proposed model, the results predicted by the proposed model were compared with analysis results of Life-365, a computer program for predicting the service life of reinforced concrete structures exposed to chlorides. In conclusion, the proposed model would be promising to predict the chloride ion profile and to estimate the service life of RC structures.

A Study on Corrosion Properties of Reinforced Concrete Structures in Subsurface Environment (지중 환경하에서의 철근콘크리트 구조물의 부식 특성 연구)

  • Kwon, Ki-jung;Jung, Haeryong;Park, Joo-Wan
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.79-85
    • /
    • 2016
  • A concrete silo plays an important role in subsurface low- and intermediate-level waste facilities (LILW) by limiting the release of radionuclides from the silo geosphere. However, due to several physical and chemical processes the performance of the concrete structure decreases over time and consequently the concrete loses its effectiveness as a barrier against groundwater inflow and the release of radionuclides. Although a number of processes are responsible for degradation of the silo concrete, it is determined that the main cause is corrosion of the reinforcing steel. Therefore, the time it takes for the silo concrete to fail is calculated based on two factors: the initiation time of corrosion, defined as the time it takes for chloride ions to penetrate through the concrete cover, and the propagation time of corrosion. This paper aims to estimate the time taken for concrete to fail in a LILW disposal facility. Based on the United States Department of Energy (DOE) approach, which indicates that concrete fails completely once 50% of the volume of the reinforcing steel corrodes, the corrosion propagation time is calculated to be 640 years, which is the time it takes for corrosion to penetrate 0.640 cm into the reinforcing steel. In addition to the corrosion propagation time, a diffusion equation is used to calculate the initiation time of corrosion, yielding a time of 1284 years, which post-dates the closure time of the LILW disposal facility if we also consider the 640 years of corrosion propagation. The electrochemical conditions of the passive rebar surface were modified using an acceleration method. This is a useful approach because it can reduce the test time significantly by accelerating the transport of chlorides. Using instrumental analysis, the physicochemical properties of corrosion products were determined, thereby confirming that corrosion occurred, although we did not observe significant cracks in, or expansion of, the concrete. These results are consistent with those of Smartet al., 2006 who reported that corrosion products are easily compressed, meaning that cracks cannot be discerned by eye. Therefore, it is worth noting that rebar corrosion does not strongly influence the hydraulic conductivity of the concrete.

Characteristics of Pore Structure and Chloride Penetration Resistance of Concrete Exposed to Freezing-Thawing (동결융해 작용을 받은 콘크리트의 공극구조 및 염화물 침투저항 특성)

  • Choi, Yoon Suk;Won, Min Sik;Yi, Seong Tae;Yang, Eun Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.73-81
    • /
    • 2012
  • Concrete structures are commonly exposed to freezing-thawing condition. This freezing-thawing action changes the pore structure of concrete, and it can reduce the durability of concrete. In this study, the change of the internal pore structure and durability of concrete due to freezing-thawing action are investigated. According to results, the excellent durability records were reported by the existing evaluation methods for all mixes. However, the pores, 50~100nm size in diameter, are increased in concrete specimens exposed to freezing-thawing action, and the chloride penetration resistance was significantly reduced. The linear relationship between pore structure and chloride penetration resistance was shown in water cured concrete. Meanwhile, the linear relationship was decreased when concrete is exposed to freezing-thawing condition. It is desirable to review the criterion of durability evaluation for concrete specimens exposed to freezing-fthawing and chloride attack condition, simultaneously.

Development and Application of Ultra High Performance Concrete (초고성능 콘크리트의 개발과 활용)

  • Kim, Sung-Wook;Park, Jung-Jun;Kang, Su-Tae;Ryu, Gum-Sung;Koh, Gyung-Taek;Lee, Jang-Hwa
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1117-1120
    • /
    • 2008
  • In order to develop an Ultra High Performance Concrete (UHPC) suited to the Korean conditions, KICT has carried out several parts of research in the field of UHPC from 2003. KICT developed UHPC which was a structural material exhibiting very remarkable mechanical performances with compressive strength, tensile strength and flexural strength rising up to 200MPa, 15MPa and 35MPa, respectively. In addition, this material presents exceptional durability regard to the very low diffusion and penetration speeds of noxious substances like chloride ions. This 200MPa strength concrete has been effectively adopted for the construction of bridges like Sherbrooke Bridge in Canada in 1997, Sunyu Bridge in Korea in 2002, Meata Bridge in Japan in 2003, Sheperds Guelly Creek Bridge, the first ultra-high strength concrete highway bridge in Australia in 2004 and, more recently in 2005, Mars Hill highway bridge in USA in 2005. The construction of structures using ultra high performance concrete is a worldwide development trend of concrete technology for the construction of advanced facilities in the 21st century.

  • PDF

Study on the Water Penetration in Mortar by Water Pressure (수압에 따른 모르타르내 수분침투에 관한 연구)

  • Yoo, Jo-Hyeong;Lee, Han-Seung;Cho, Hyeong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.505-508
    • /
    • 2008
  • Concrete is a type of porous materials and is physically and chemically damaged due to exposure to various environments from the placing to the service life. These reactions affect the corrosionof steel bars applied in concrete and that decreases the durability life and strength of such steel bars. Thus, it is very important to insert rust inhibitors into steel bars in the case of a deterioration element that exceeds the critical amount of corrosion in the location of steel bars. However, it is very difficult to guarantee corrosion resistance at the location of steel bars using conventional technology that applies corrosion inhibitors only on the surface of concrete. This study attempts to develop a method that penetrates corrosion inhibitors up to the location of steel bars and investigate the penetration depth of corrosion inhibitors by verifying moisture migration in concrete under an applied pressure.

  • PDF

Characterization of Acryl Polymer Concretes for Ultra Thin Overlays (초박층 덧씌우기용 아크릴 폴리머 콘크리트의 특성 연구)

  • Kim, Dae-Young;Kim, Tae-Woo;Lee, Hyun-Jong;Kim, Hyung-Bae
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.1-8
    • /
    • 2010
  • This study is performed to evaluate the physical and mechanical characteristics of an acryl polymer concrete that is developed as an overlay material for cement concrete slabs and pavements. Various laboratory tests including viscosity, flow, compressive strength, flexural strength, tensile strength, linear shrinkage, thermal expansion and thermal compatibility tests are performed. It is observed from the laboratory tests that the acryl polymer concrete developed in this study satisfies all the requirements suggested by ACI guideline. In addition to the laboratory tests, an accelerated performance testing (APT) is conducted to validate the performance of the acryl polymer concrete. During the APT, no significant distresses are observed until 15,903,939 cycles of equivalent single axle loading is applied. Finally, a 10mm thick overlay with the acryl polymer concrete is applied on top of an old deteriorated concrete pavement to evaluate field performance. Right after the field construction, skid resistance, noise and roughness are measured. The skid resistance and noise level have been significantly improved while the roughness is increased. Periodic investigation for the field study section will be conducted to evaluate the long-term performance.