• 제목/요약/키워드: 콘덴서

검색결과 383건 처리시간 0.037초

적층 세라믹콘덴서 제조공정에서 $BaTiO_3$의 분산이 테이프캐스팅 성형체의 물성에 미치는 영향 (Effect of $BaTiO_3$ Dispersion on the Properties of Cast Tapes in Processing of Multilayer Ceramic Capacitor(MLCC))

  • 김봉호;김병관;김명호;백운규
    • 한국세라믹학회지
    • /
    • 제33권2호
    • /
    • pp.214-222
    • /
    • 1996
  • The effect of physicochemical properties of organic solvent and dispersant among organic solvent dispersant binder and plasticizer which are used as processing additives in MLCC fabrication process on the dispersion of BaTiO3 was studied. The steric and electrostatic stabilization mechanisms in dispersion of BaTiO3 in organic media were evaluated respectively. The sttability of BaTiO3 achieved bysteric stabilization was dependent on the fraction of surface coverage of dispersant adsorption on BaTiO3. The electrostatic repulsive forces of BaTiO3 particles dispersed in orgainc media was found to be appreciabley great and dependent mainly on the kinds of organic solvent used. The mechanism affecting the stability of BaTiO3 was studied by the method of rheologi-cal behaviors of BaTiO3 suspension.

  • PDF

유도결합 플라즈마에서 임피던스 정합조건을 용한 비침투식 진단방법

  • 김영도;정진욱
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2013
  • 유도결합 플라즈마 방전 시 사용되는 L형 임피던스 정합기(impedance matcher)의 경우 일반적으로 직렬 및 병렬 콘데서가 연결되어있으며, 임피던스 정합조건이 되었을때 전원과 안테나 사이에 있는 임피던스 정합기의 소자값이 특정 값을 가지게 된다. 유도결합 플라즈마를 진단하기 위한 여러 방법들이 연구되어 왔지만, 이러한 임피던스 정합조건과 플라즈마 내부 변수들의 상관 관계에 대한 연구는 보고된 바 없다. 본 연구에서는 유도결합 플라즈마의 임피던스 정합조건과 유도결합 플라즈마의 변압기 회로모델를 이용하여 플라즈마 저항 및 플라즈마 인덕턴스를 구하기 위한 관계식을 도출하고 임피던스 정합기의 직렬 및 병렬 콘덴서 용량값 측정하여 플라즈마 저항 및 플라즈마 인덕턴스값을 계산하였다. 결과 검증을 위해 다양한 압력 및 전력 조건에서 부유랑뮤어 탐침법을 이용하여 플라즈마 밀도를 측정해 비교해 보았으며, 두 결과의 경향성은 잘 일치함을 확인하였다.

  • PDF

콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계 (A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE)

  • 김화종;이상찬;오응종;이희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF

분할공진 콘덴서를 갖는 전류형 고주파 인버터의 특성해석과 설계 (Analysis Chatacteristics and Design of a Current-fed High Frequency inverter with Separated Resonant Capacitor)

  • 이봉섭;김동희
    • 조명전기설비학회논문지
    • /
    • 제12권2호
    • /
    • pp.91-98
    • /
    • 1998
  • 본 논문은 병렬 공진 커패시터를 분리 설치한 전류형 고주파 인버터를 대상으로 하여 그 운전 특성에 대해 논하고 있다. 회로 해석은 정규화 파라메타를 도입하여 범용성 있게 기술하고 있으며, 회로의 특성평가도 행하였다. 또한, MOSFET를 스위칭 소자로 사용여 실험을 행한 결과, 이론적 해석과 잘 일치하고 있어, 연구 대상 회로의 이론적 해석의 정당성을 입증하고 있다. 향후, 제안회로는 유도 가열용 고주파 전원 등으로 활용되리라 기대된다.

  • PDF

근골격계 질환 예방활동 우수사례

  • 박찬성;김중태
    • 산업안전기술지
    • /
    • 제3권1호
    • /
    • pp.31-35
    • /
    • 2003
  • 충남 아산시에 위치하고 있는 당사의 주 생산품은 김치냉장고, 에어컨 등의 위니아 공장 생산품과 히터, 콘덴서 등의 차량공조 생산품이며, 총 근로자 수는 1,310명으로서 이 중에서 90명은 여성 근로자가 차지하고 있다. 만도공조(주)는 1962년 10월 (주) 현대양행으로 시작된 이래로, 1995년 12월 ISO-9001 인증을 획득하였고, 2000년 1월 무재해 1배 달성(210만 시간), 2000년 7월 KOSHA 2000 P/G를 인정받았다. 이어서 무재해 2배(420만 시간)를 달성하였고, 2001년 10월 ISO-14001을 인정받았다. 한편, 당사의 과거 9년간 산업재해 발생현황을 살펴보면 그림 1에 제시된 바와 같이 최근에 산업재해 발생율이 약간 증가하기는 하였으나, 전반적으로 1995년에 17건의 산업재해를 기록한 이후로 감소하고 있는 추세이다. 근골격계질환에 대해서 살펴보면, 산업재해건수 대비 근골격계질환 발생비율이 1998년부터 0%를 기록하고 있다.(중략)

  • PDF

콘덴서 제어회로를 이용한 배전용 변압기의 역률 개선에 관한 연구 (A Study for Improving the Power Factor of Distribution Transformer using Condenser Control Circuit)

  • 이광직
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.21-28
    • /
    • 2014
  • Daily use characteristics of apparent power supplied to distribution transformer can be separated into two different time zone of waking hours and sleeping hours. In sleeping hours, using amount of power is decreasing. The actual curve of power seemed to be quite similar to this kind of separation. Inserting a condenser into a circuit in each different time zone led to maximize power factor of the transformer. The compensating condenser's on/off time is controlled by hysteresis circuit utilizing op amp and power factor of the transformer was improved from 0.945 to 0.999. As a result, the average of current reduction was 2.53A per hour of transformer.

콘덴서 양부판정용 충·방전 시험기 설계와 구현에 관한 연구 (A Study on the Design and Implementation of Charge and Discharge-Tester for Capacitors)

  • 문종현;김금수;박재욱;서철식;김동희
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.71-78
    • /
    • 2010
  • The existing capacitor-testers could only judge the condition of capacitor is normal or abnormal, and could not inform the real characteristics of the tested capacitors. In this research, it has designed the real-time observation of the new capacitor in charge and discharge tester for showing capacitor conditions and classification through wide voltages by regular cycle-tests. And proposed the quality classification algorithm of capacitors for more simple and practical, and approve them by test.

전력계통변경에 따른 수력발전소 수전역률저하와 그 대책에 관한 연구 (A Study on Solution and a Drop of Power Factor according to a Change of Power Network)

  • 윤종범;최장건;오봉록;옥광석;박경환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.287-289
    • /
    • 2003
  • 합천수력발전소는 1989년 준공이후 최근까지는 발전정지시 전력계통으로부터 전력을 수전할 경우 수전역률이 90%이상되어 문제가 없었으나, 2001년 6월경 전력계통이 논공154kV변전소에서 고령345kV변전소로 변경된 이후, 계통전압이 평균 $2.5{\sim}3.0kV$상승함으로써 역률이 약70%로 저하하였다. 이런 전압상승은 전력계통의 무효전력조정에 의한 것으로, 수전시 합천수력발전소의 평균소비전력은 주변압기 용량의 약0.55%로 전력계통에서 발전소를 바라보면 주변압기가 무부하로 운전되는 것처럼 보이게 되어 발전소내에서 소비되는 무부하손이 증가하여 역률이 저하한 것으로 검토되었다. 이런 무효전력소비는 주변압기에만 국한되어 있으므로 역률개선용 콘덴서를 주변압기 1차측에 설치하여 저하된 역률을 보상할 수 있었다.

  • PDF

유한요소법과 등가회로 해석의 결합에 의한 콘덴서 구동형 단상유도전동기의 특성해석 (Characteristic Analysis of Capacitor-Run Single Phase Inuction Motor by Equivalent Circuit Coupled with Finite Element Method)

  • 남혁;하경호;강규홍;홍정표;정승규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.837-839
    • /
    • 2000
  • Capacitor-run single induction motors have the unbalanced elliptic rotating magnetic field so that it is difficult to analyze the characteristic and calculate the accurate slot leakage reactance of the rotor with the closed slot by using the lumped parameter. In this paper, the characteristic is analyzed by the symmetrical coordinate method in terms of the lumped parameter coupled with the numerical analysis. The secondary parameters are calculated by the one slot pitch boundary condition applying to Finite Element Method (FEM). The analysis results are compared with experimental ones.

  • PDF

저압 콘덴서의 열원 분포 해석 (Analysis of Heat Source Distribution in Low Voltage Condenser)

  • 김종겸;이동주;김일중;박영진
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1242-1247
    • /
    • 2010
  • In this study, the heat source distributions at the end side and the center of the electrode are analyzed to estimate the electrical stress due to the harmonics from the nonlinear loads. The governing equation at the analysis area of low voltage condenser are numerically solved using the finite element software package to analyze the effects of heat source distribution due to the 5th and 7th harmonics, which can exist normally in the distribution network and can be applied to the low voltage condenser. Finally, the heat source distribution from the harmonics is compared and analyzed with the heat source distribution from the fundamental component of the applied voltage.