• Title/Summary/Keyword: 코덱스

Search Result 41, Processing Time 0.03 seconds

Error Concealment of MPEG-2 Intra Frames by Spatiotemporal Information of Inter Frames (인터 프레임의 시공간적 정보를 이용한 MPEG-2 인트라 프레임의 오류 은닉)

  • Kang, Min-Jung;Ryu, Chul
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.2
    • /
    • pp.31-39
    • /
    • 2003
  • The MPEG-2 source coding algorithm is very sensitive to transmission errors due to using of variable-length coding. When the compressed data are transmitted, transmission errors are generated and error correction scheme is not able to be corrected well them. In the decoder error concealment (EC) techniques must be used to conceal errors and it is able to minimize degradation of video quality. The proposed algorithm is method to conceal successive macroblock errors of I-frame and utilize temporal information of B-frame and spatial information of P-frame In the previous GOP which is temporally the nearest location to I-frame. This method can improve motion distortion and blurring by temporal and spatial errors which cause at existing error concealment techniques. In network where the violent transmission errors occur, we can conceal more efficiently severe slice errors. This algorithm is Peformed in MPEG-2 video codec and Prove that we can conceal efficiently slice errors of I-frame compared with other approaches by simulations.

  • PDF

Spatio-Temporal Error Concealment of I-frame using GOP structure of MPEG-2 (MPEG-2의 GOP 구조를 이용한 I 프레임의 시공간적 오류 은닉)

  • Kang, Min-Jung;Ryu, Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1C
    • /
    • pp.72-82
    • /
    • 2004
  • This paper proposes more robust error concealment techniques (ECTs) for MPEG-2 intra coded frame. MPEG-2 source coding algorithm is very sensitive to transmission errors due to the use of variable-length coding. The transmission errors are corrected by error correction scheme, however, they cannot be revised properly. Error concealment (EC) is used to conceal the errors which are not corrected by error correction and to provide minimum visual distortion at the decoder. If errors are generated in intra coded frame, that is the starting frame of GOP, they are propagated to other inter coded frames due to the nature of motion compensated prediction coding. Such propagation of error may cause severe visual distortion. The proposed algorithm in this paper utilizes the spatio-temporal information of neighboring inter coded frames to conceal the successive slices errors occurred in I-frame. The proposed method also overcomes the problems that previous ECTs reside. The proposed algorithm generates consistent performance even in network where the violent transmission errors frequently occur. Algorithm is performed in MPEG-2 video codec and we can confirm that the proposed algorithm provides less visible distortion and higher PSNR than other approaches through simulations.

Development of an Analytical Method for Chloropicrin Determination in Hulled Rice by GC-ECD and GC-MS (GC-ECD 및 GC-MS를 이용한 현미 중 chloropicrin의 잔류시험법 개발)

  • Do, Jung-Ah;Choi, Jeong-Heui;Park, Hyejin;Park, Yong-Chun;Yoon, Hae-Jung;Choi, Dongmi;Oh, Jae-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.222-226
    • /
    • 2013
  • A simple and sensitive analytical method was developed using gas chromatograph with electron capture detector (GC-ECD) and gas chromatograph-mass spectrometer (GC-MS) for determination and identification of chloropicrin. Because of small molecular weight and high volatile properties of chloropicrin, analytical method was developed utilizing headspace extraction and direct injection to the GC. The developed method was validated using hulled rice sample spiked with chloropicrin at different concentration levels, 0.1 and 0.5 mg/kg. Average recoveries of chloropicrin (using each concentration three replicates) ranged 77.7~79.3% with relative standard deviations less than 10% and calibration solutions concentration in the range $0.005{\sim}0.5{\mu}g/mL$, and limit of detection (LOD) and limit of quantification (LOQ) were 0.004 and 0.01 mg/kg, respectively. The result showed that developed analytical methods was successfully applied to detect a small amount of chloropicrin in hulled rice.

Development and Validation of an Analytical Method for Flutianil Residue Identification Using Gas Chromatography-Electron Capture Detection (GC-ECD를 이용한 flutianil 잔류량 분석법 개발 및 확인)

  • Kwon, Ji-Eun;Do, Jung-Ah;Park, Hyejin;Lee, Ji-Young;Cho, Yoon-Jae;Oh, Jae-Ho;Rhee, Gyu-Seek;Lee, Sang-Jae;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • A sensitive and simple analytical method to identify flutianil residues in agricultural commodities was developed and validated using gas chromatography-electron capture detection (GC-ECD) and mass spectrometry (GC-MS). The flutianil residues were extracted with acetonitrile, partitioned with dichloromethane, and then purified using a silica solid-phase extraction (SPE) cartridge. The method was validated using pepper, sweet pepper, mandarin, hulled rice, soybean, and potato spiked with 0.02 or 0.2 mg/kg flutianil. The average recovery of flutianil was 76.5-108.0% with a relative standard deviation of less than 10%. The limit of detection and limit of quantification were 0.004 and 0.02 mg/kg, respectively. The result of recoveries and relative standard deviation were in line with Codex Alimentarius Commission Guidelines (CAC/GL 40). These results show that the method developed in this study is appropriate for flutianil identification and can be used to maintain the safety of agricultural products containing flutianil residues.

Development and validation of an analytical method for the determination of lepimectin residues by HPLC-PDA (HPLC-PDA를 이용한 lepimectin 잔류량 분석법 개발 및 확인)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • A new, rapid, and simple analytical method was developed and validated using high performance liquid chromatograph-photodiode array detector (HPLC-PAD) for the determination of lepimectin residues in agricultural commodities. The lepimectin residues in samples were extracted with methanol, partitioned with dichloromethane, and then purified with glass column filled with subsequently to aminopropyl ($NH_2$) solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-PAD. Correlation coefficient ($R^2$) of both lepimectin $A_3$ and $A_4$ solutions were 0.9999. The method was validated using cucumber spiked with lepimectin at 0.02 and 0.2 mg/kg and pepper, mandarin, hulled rice, potato, soybean at 0.02 and 0.5 mg/kg. Average recoveries were 76.0~114.8% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.01 mg/kg, respectively. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional KFDA and Daejeon regional KFDA was followed with Codex guideline (CAC/GL 40). Therefore, developed method in this study is accurate, rapid, and appropriate for lepimectin determination and will be used to keep safety of lepimectin residues in agricultural products.

Scientific Principles on the Revision and Addition of the Codex Nutrient Reference Values for Food Labelling Purposes (식품표시를 위한 코덱스 영양소기준치 개정에 필요한 과학적 근거)

  • Chang, Nam-Soo;Cho, Youn-Ok;Joung, Hyo-Jee;Chung, Hae-Rang;Kim, Hye-Young;Choi, Young-Sun;Lim, Hyeon-Sook;Yun, Jin-Sook;Kwon, O-Ran
    • Journal of Nutrition and Health
    • /
    • v.42 no.2
    • /
    • pp.183-188
    • /
    • 2009
  • There has been a need to update the current Codex nutrient reference values (NRVs) which had been established following the Helsinki Consultation in 1988. The main purposes of NRVs are to help consumers compare the nutrient content of different food products and estimate the usefulness of a food product in terms of its percentage contribution to the overall healthful diets. The establishment of Codex NRVs for labelling purposes is intended to facilitate the goals of protecting consumers' health and ensuring fair practices in food trade. When revising the Codex NRVs several issues are needed to discussed, which are: 1) Consideration of population groups whether to have one set of NRVs for general population or to have several sets of NRVs for each population groups, 2) Determination of scope of nutrients such as what nutrients to include and what reference values to choose and 3) Development of principles for establishing NRVs such as the selection of suitable reference values among many including recommended intake/recommended dietary allowances, estimated average requirement and upper levels to extract NRVs. This paper will discuss the above issues and the inputs and efforts that the Korean Nutrition Society had put into to carry out the project, "International Collaboration on the Revision and Addition of the Codex Nutrient Reference Values for Food Labelling Purposes," and to ascertain relevant scientific principles and evidences that are utilized for establishment and revision of the Codex NRVs.

Development and validation of analytical methods for pyrifluquinazon residues determination on agricultural commodities by HPLC-UVD (HPLC-UVD를 이용한 농산물 중 pyrifluquinazon 잔류시험법 개발 및 검증)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Cho, Yoon-Jae;Chang, Moon-Ik;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.174-181
    • /
    • 2013
  • Pyrifluquinazon is classified with a quinazoline insecticide that regulates food intake by controling the feeding behavior acting on the endocrine or nervous system of pests such as aphids and white fly. To keep safety on pyrifluquinazon residues in agricultural commodities a simple, accurate and rapid analytical method was developed and validated using high performance liquid chromatograph (HPLC-UVD). The pyrifluquinazon residues acidified with 1% formic acid in samples were extracted with acetonitrile and partitioned with hexane subsequently to dichloromethane then purified with silica solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-UVD. The method was validated using apple and pear spiked with pyrifluquinazon at 0.02, 0.05 and 0.1 mg/kg and hulled rice, pepper, soybean at 0.05 and 0.1 mg/kg. Average recoveries were 70.5~107.9% with relative standard deviation less than 10%. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional FDA and Daejeon regional FDA was followed with Codex guideline (CODEX CAC/GL 40). This method is appropriated at pyrifluquinazon residues determination and will be used as official method of analysis.

Current status of comparative compositional analysis for GM crop biosafety assessment (유전자변형작물 안전성평가를 위한 영양성분 비교연구 동향)

  • Kim, Eun-Ha;Oh, Seon-Woo;Lee, Sang-Gu;Lee, Sung-Kon;Ryu, Tae-Hun
    • Journal of Plant Biotechnology
    • /
    • v.47 no.4
    • /
    • pp.261-272
    • /
    • 2020
  • Approvals for cultivation and import of genetically modified (GM) crops have dramatically increased around the world. Comparative compositional studies are an important aspect of safety assessments of products from GM crops and are based on substantial equivalence. Compositional analyses focus on determining similarities and differences between the compositions of the GM crops and their conventional counterparts, and thereby assessing the compositional equivalence of GM crops and their conventional comparators. The analytes, such as major constituents, key nutrients, and antinutrients, are generally determined on a crop-specific basis according to the OECD consensus document. The use of standard methods throughout the processes, such as selection of comparators, field trials, analytical methods, and statistical data analysis, is crucial. In this study, we showed the general framework of compositional studies. Literature for compositional studies of GM crops conducted abroad and in Korea was reviewed to obtain information about analytes, conventional counterparts, cultivation year, location, and statistical methods. The studies conducted abroad assessed for commercial release of GM crops such as soybean, maize, and cotton, while domestic studies were mainly performed for research in rice. In addition, we suggested a guidance for conventional comparators and field trials applicable to the domestic situation.

Arsenic species in husked and polished rice grains grown at the non-contaminated paddy soils in Korea (국내 비오염 논토양에서 재배한 현미와 백미 중 비소화학종 함량)

  • Kim, Da-Young;Kim, Ji-Young;Kim, Kye-Hoon;Kim, Kwon-Rae;Kim, Hyuck-Soo;Kim, Jeong-Gyu;Kim, Won-Il
    • Journal of Applied Biological Chemistry
    • /
    • v.61 no.4
    • /
    • pp.391-395
    • /
    • 2018
  • There is an increasing concern over arsenic (As) contamination of paddy soil and rice with regard to food safety. This study was conducted to investigate total and inorganic As concentration in one hundred husked and polished rice samples collected at the non-contaminated paddy soil in Korea. Arsenic species in rice samples were extracted using 1% nitric acid ($HNO_3$) with a microwave oven and were measured using high performance liquid chromatography coupled with inductively coupled plasma-mass spectrometry. Mean concentrations of total As in husked rice and polished rice were 0.18 and $0.11mg\;kg^{-1}$, respectively. Also, average inorganic As concentrations in husked rice and polished rice were 0.11 and $0.07mg\;kg^{-1}$, respectively. These levels are lower than the standard guideline value 0.35 and $0.2mg\;kg^{-1}$ for inorganic As in husked and polished rice recommended by Codex Committee on Contaminants in Foods and Ministry of Food and Drug Safety, respectively. The mean of the inorganic As ratio for the total amount of As was 0.65 and 0.67 for husked rice and polished rice, respectively, and the range was from 0.08 to 1.0. For health risk assessment, the average value of cancer risk probability was $9.24{\times}10^{-5}$ and ranged from $2.30{\times}10^{-5}$ to $1.90{\times}10^{-5}$. Therefore, human exposure to As through dietary intake of surveyed rice samples might considered to be a low health risk.

Motion Vector Coding Using Adaptive Motion Resolution (적응적인 움직임 벡터 해상도를 이용한 움직임 벡터 부호화 방법)

  • Jang, Myung-Hun;Seo, Chan-Won;Han, Jong-Ki
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.165-178
    • /
    • 2012
  • In most conventional video codecs, such as MPEG-2 and MPEG-4, inter coding is performed with the fixed motion vector resolution. When KTA software was developed, resolution for MVs can be selected in each slice. Although KTA codec uses a variety of resolutions for ME, the selected resolution is applied over the entire pixels in the slice and the statistical property of the local area is not considered. In this paper, we propose an adaptive decision scheme for motion vector resolution which depends on region, where MV search area is divided to multiple regions according to the distance from PMV. In each region, the assigned resolution is used to estimate MV. Each region supports different resolution for ME from other regions. The efficiency of the proposed scheme is affected from threshold values to divide the search area and the entropy coding method to encode the estimated MV. Simulation results with HM3.0 which is the reference software of HEVC show that the proposed scheme provides bit rate gains of 0.9%, 0.6%, and 2.9% in Random Access, Low Delay with B picture, and Low Delay with P picture structures, respectively.