• 제목/요약/키워드: 컬럼

Search Result 976, Processing Time 0.021 seconds

Removals of Formaldehyde by Silver Nano Particles Attached on the Surface of Activated Carbon (나노 은입자가 첨착된 활성탄의 포름알데히드 제거특성)

  • Shin, Seung-Kyu;Kang, Jeong-Hee;Song, Ji-Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.10
    • /
    • pp.936-941
    • /
    • 2010
  • This study was conducted to investigate formaldehyde removals by silver nano-particles attached on the surface of granular activated carbon (Ag-AC) and to compare the results to those obtained with ordinary activated carbon (AC). The BET analysis showed that the overall surface area and the fraction of micropores (less than $20{\AA}$ diameter) of the Ag-AC were significantly decreased because the silver particles blocked the small pores on the surface of the Ag-AC. The formaldehyde removal capacity of the Ag-AC determined using the Freundlich isotherm was higher than that of AC. Despite the decreased BET surface area and micropore volume, the Ag-AC had the increased removal capacity for formaldehyde, presumably due to catalytic oxidation by silver nano-particles. In contrast, the adsorption intensity of the Ag-AC, estimated by 1/n in the Freundlich isotherm equation, was similar to that of the ordinary AC, indicating that the surface modification using silver nano-particles did not affect the adsorption characteristics of AC. In a column experiment, the Ag-AC also showed a longer breakthrough time than that of the AC. Simulation results using the homogeneous surface diffusion model (HSDM) were well fitted to the breakthrough curve of formaldehyde for the ordinary AC, but the predictions showed substantial deviations from the experimental data for the Ag-AC. The discrepancy was due to the catalytic oxidation of silver nano-particles that was not incorporated in the HSDM. Consequently, a new numerical model that takes the catalytic oxidation into accounts needs to be developed to predict the combined oxidation and adsorption process more accurately.

Gas Chromatographic Analysis on the Residual of Fungicide Fenhexamid in Crops(Cucumber, Strawberry and Grape) (작물(오이, 딸기, 포도) 중 살균제 Fenhexamid의 잔류성에 대한 기체 크로마토그래피 분석)

  • Han, Seong-Soo;Lo, Seog-Cho;Kim, Won-Ju;Park, PiII-Jae;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.70-77
    • /
    • 2003
  • The optimum conditions for the residue analysis of hydroxyanilide fungicide fenhexamid on cucumber, strawberry and grape were investigated by gas chromatography equipped with electron capture detector (GC-ECD) and the residual amount was determined by sprayed days before harvest. Each samples were extracted with acetone, filtered and concentrated to 50 mL. The concentrated extracts were transferred to dichloromethane and then thoroughly concentrated. The concentrated phase was loaded on the filtration column stuffed with silica gel and purified with acetone:hexane (5:95, 15:85, v/v) mixed solvent. The regression equation and linearity of the standard calibration curves between 0.05~2.00 ng were as follows : cucumber; Y=312.40X+10.26, $R^2=0.9996$, strawberry; Y=313.33X+5.54, $R^2=0.9998$, grape; Y=253.27X-2.23, $R^2=0.9994$. From the standard additional experiments with 0.10 mg/L and 0.40 mg/L, the average recoveries of cucumber, strawberry and grape were 94.8%, 88.1% and 93.7%, respectively and the detection limits were all the same as 0.01 mg/L. Residual amounts in crops were ranged from 0.01 to 0.58 mg/L.

Determining Anti-impotence drug-like compounds in Food (식품 중 발기부전치료제 및 유사물질의 분석)

  • Choi, Dongmi;Im, Mooheg;Lee, Kyungjin;Kwon, Kwangil;Jeong, Jiyoon;Park, Gunsang;Hong, Mooki;Lee, Chulwon
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.520-526
    • /
    • 2004
  • To determine 6 anti-impotence drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil and hongdenafil in food, simultaneously, high performance liquid chromatography was applied. In the case of solid sample, it was extracted in organic solvents after homogenizing with mortar and pestle. Whereas liquid sample was just diluted in water and then extracted in organic solvents. Maximum lengths of UV for targets have been identified on photodiode array spectra. As results, vardenafil, hongdenafil, hydroxyhomosildenafil, sildenafil, homosildenafil, and tadalafil were eluted in order using $C_{18}$ column in acetonitrile containing phosphoric acid as the mobile phase. The maximum wavelength (${\lambda}_{max}$) was 216 nm for vardenafil, 233 and 282 nm for hongdenafil, 222 and 293 nm for hydroxyhomosildenafil, sildenafil and homosildenafil, and 284 nm for tadalafil. The overall recoveries were ranged from 95% to 109% and the limit of detection was about 0.04 mg/kg at signal/noise>3. Levels of targets in the selected food samples were 1.7 (hongdenafil) ~ 63 (tadalafil) mg/one dose.

Simultaneous analysis of β-lactam antibiotics and β-blockers by LC-MS/MS (LC-MS/MS를 이용한 베타락탐계 항생제와 베타차단제의 동시분석)

  • Son, Bo-young;Kim, Jun-il;An, Chi-hwa;Lee, Su-won;Kim, Bogsoon;Chung, Deukmo
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.179-185
    • /
    • 2016
  • An effective analytical method has been developed for the determination of β-blockers(atenolol, metoprolol and propranolol) and 6 β-lactams(amoxicillin, penicillin G, cefaclor, cefadroxil, cephalexin and cephradine) in water samples using two different cartridges. The samples were extracted by solid-phase extraction (SPE) with the usage of polymeric hydrophile-lipophile balance(HLB cartridges) and strong cation-exchange mixed-mode polymeric sorbent (MCX cartridges). A XDB-C18 column(1.8 μm; 3.0 mm × 100 mm) was used for the sufficient chromatographic resolution. The calibration curves showed good linearity with high correlation coefficients (>0.995). The method detection limits (MDL) and the limits of quantification(LOQ) were from 1.1 to 3.9 ng/L and from 5 to 13 ng/L, respectively. The method was applied for the determination of the target compounds in tributaries and raw water of the Han River and these were found at N.D. to 0.209 μg/L.

Determination of bromide in bottled mineral water and ground water in Korea (먹는 샘물 및 지하수 원수 중 bromide 분석연구)

  • Ahn, Hye-Sil;Seo, Kyoung-Ae;Park, Ju-Hyun;Lee, Jun-Bae;Kim, Tae-Seung;Han, Jin-Seok;Kwon, Oh-Sang
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.10-14
    • /
    • 2011
  • This study was performed to compare international analytical methods of bromide and applied to determine bromide in bottled mineral water and raw ground water in Korea. Bromide in water was eluted by 10~50 mM potassium hydroxide (KOH) and determined by ion chromatography-suppressed conductivity detector (IC-CD). Sample was purified with Ba- and H-on-guard cartridge and $0.2\;{\mu}m$ membrane filter. The method detection limit (MDL) and the limit of quantitation (LOQ) of bromide were 0.2 and $0.5\;{\mu}g/L$, respectively. The calibration curve showed good lineality above 0.9993 in the ranges of the $0.5\sim80\;{\mu}g/L$. A correlation coefficient of bromide in ground water and sum of bromide and bromate in bottled mineral water is 0.808.

Studies of separation and quantitation for selenium species in food (식품중의 셀레늄 화학종의 분리 및 정량연구)

  • Jang, Hee-Young;Min, Hyungsik;Lee, Jonghae;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.182-189
    • /
    • 2013
  • The purpose of this research is to separate and quantitate selenium species in some food samples with HPLC-ICP-MS. Cation exchange chromatography showed efficient separation only for inorganic Se species while reversed phase ion pair chromatography showed good separation for both inorganic and organic Se species. $C_8$ column ($Symmetryshield^{TM}\;RP_8$, 3.5 ${\mu}m$, $4.6{\times}150$ mm) was used with optimum condition of 5% methanol mobile phase, 0.05% of nonafluorovaleric acid ion pairing reagent. Five standard Se species of Se(IV), Se(VI), SeCys(selenocystein), SeMet(selenomethionine) and Se-M-C(seleno methyl cystein) were separated successfully under the optimum condition (mobile phase; 5% methanol, ion-pairing reagent; 0.05% nonafluorovaleric acid, flow rate; 0.9 mL $min^{-1}$). To extract Se species, microwave assisted and enzyme-assisted extraction methods were studied. In enzyme-assisted extraction method, protease I for garlic, protease I plus trypsin for pork and mackerel, and protease XIV for tuna showed the best extraction efficiency. With the optimum condition for each sample, it was found that mostly inorganic Se, SeCys and SeMet are present in the sample studied ranging from few ${\mu}g$ $g^{-1}$ to few tens of ${\mu}g$ $g^{-1}$.

Development of Analytical Method for Sodium Alginate in Foods (식품 중 알긴산나트륨의 분석법 개발)

  • Kim, Hee-Yun;Hong, Ki-Hyoung;Choi, Jang-Duck;Park, Sung-Kwan;Jung, Si-Sub;Choi, Woo-Jeong;Ahn, Yeong-Sun;Hong, Yeong-Pyo;Song, Ok-Ja;Moon, Dong-Chul;Lee, Shin-Ho;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.1-4
    • /
    • 2006
  • Method of analyzing sodium alginate in foods was developed using high performance liquid chromatography (HPLC). HPLC conditions for sodium alginate were: column, MCI GEL $(8\;mm\;i.d{\times}300\;mm)$; mobile phase, deionized water; detector, refractive index detection (sensitivity = 16). Separation of sodium alginate was achieved within 15 min. Sodium alginate showed good linear relationship at 0.1-2.0% range. Correlation coefficient of calibration curve for sodium alginate exceeded 0.999, and detection limit was 0.005%. Recovery rate of sodium alginate in wheat flour dough was 106.67%. This method was successfully applied to analyses of cereals, saccharides, and ice cream, etc. Sodium alginate was detected in chocolate, noodles, and kelp at 0-44.8% range.

Study on Synthesis of 68GeO2 and Behavior of 68Ga3+ for Generator Column (Generator 컬럼용 68GeO2 합성 및 68Ga3+의 거동에 관한 연구)

  • Kim, Gun Gyun;Lee, Jun Young;Kim, Sang Wook;Hur, Min Gu;Yang, Seung Dae;Park, Jeong Hoon
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.189-192
    • /
    • 2016
  • $^{68}Ga$ has emerged as a promising candidate for non-invasive diagnostic imaging within Positron Emission Tomography (PET) because of its advantageous radiochemical characteristics ($t_{1/2}=68min$, ${\beta}^+$ yield ~89%). $^{68}Ga$ forms a stable chelation with various ligands and it is possible to be quickly and easily study using a $^{68}Ge/^{68}Ga$ generator. Commercial $^{68}Ge/^{68}Ga$ generators are chromatographic system using the inorganic materials such as alumina and tin dioxide which are employed as column matrixes for $^{68}Ge$. In this study, we tried out to make $^{68}Ge/^{68}Ga$ generator system with the $^{68}GeO_2$ microstructures for column matrix. $^{68}Ge$ tends to have stable bond with oxide as $^{68}GeO_2$ microstructures. The $^{68}GeO_2$ has been synthesized by hydrolysis of $GeCl_4$ (sol-gel method) and characterized by X-ray diffraction and scanning electron microscope for geometrical analysis. The stability of $GeO_2$ was tested using eluents with diverse solvents(water, ethanol and 0.1 N HCl). The radioactivity of $^{68}Ga^{3+}$ in eluate through $GeO_2$ was measured to prove a function as column material for a generator.

Leaching Characteristics of Arsenic and Heavy Metals and Stabilization Effects of Limestone and Steel Refining Slag in a Reducing Environment of Flooded Paddy Soil (담수된 논토양의 환원 환경에서 비소 및 중금속의 용출특성과 석회석 및 제강슬래그의 안정화 효과 검토)

  • Yun, Sung-Wook;Kang, Sin-Il;Jin, Hae-Geun;Kim, Ha-Jin;Yu, Chan
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.251-263
    • /
    • 2011
  • In order to investigate treatment effects of limestone and steel refining slag for paddy soils contaminated with arsenic and heavy metals, a lab-column test was carried out under reducing environments of flooded paddy soils. In conditions of the flooded paddy soils, at the point of time when iron and manganese were reduced and leached rapidly, heavy metals also leached rapidly, and some leachate samples from an untreated soil exceeded regulatory standards. On the contrary, all samples from soils treated with limestone 5% and steel refining slag 5% respectively were below the regulatory standards, showing much lower heavy metal concentrations than in the untreated soil. Arsenic increased continuously during the observation period according to its typical characteristics, and along with decreasing redox potential, arsenic was expected to leach as $H_3AsO_3$-of form $A^{3+}$ with high mobility and strong toxicity. Limestone and steel refining slag showed high treatment effects against heavy metals present in soil and steel refining slag especially showed the high treatment effects against arsenic.

Development of Simultaneous Analysis of Ferulic Acid, Caffeic Acid, Catechin and Taxifolin from Health Functional Food Pinus Pinaster Bark Extract by UPLC-MS/MS (건강기능식품 프랑스해안송껍질추출물 중 UPLC-MS/MS를 이용한 Ferulic acid, Caffeic acid, Catechin, Taxifolin 동시분석법 개발 연구)

  • Oh, Jae-Myoung;Kim, Ji An;Hu, Soo Jung;Choi, Yoon Hee;Oh, Keum Soon
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.431-437
    • /
    • 2019
  • This study was conducted to develop a simultaneous analysis method for ferulic acid, caffeic acid, catechin and taxifolin from Health Functional Food (HFF) Pinus Pinaster bark extract. The simultaneous analytical method for ferulic acid, caffeic acid, catechin and taxifolin is carried out using UPLC-MS/MS. The method validation was performed to determine selectivity, linearity, accuracy, limit of detection (LOD), limit of quantification (LOQ) and precision for ferulic acid, caffeic acid, catechin and taxifolin. LC-MS/MS method was established using an Acquity UPLC BEH $C_{18}$ Column and was applied for these 4 compounds. Product-ion traces, at m/z $194.2{\rightarrow}133$, $180.2{\rightarrow}135$, $290.3{\rightarrow}245$, $304.3{\rightarrow}248$, were used for quantitative analysis of ferulic acid, caffeic acid, catechin and taxifolin, respectively. Excellent linearity ($r^2=0.999$) was observed for ferulic acid, caffeic acid, catechin and taxifolin in the concentration range (50-2500 mg/L). The observed recoveries of these 4 compounds were found to be between 84.9 and 104.9%, while precision was between 1.20 and 4.43% relative standard deviation (% RSD).