Browse > Article
http://dx.doi.org/10.5806/AST.2011.24.1.010

Determination of bromide in bottled mineral water and ground water in Korea  

Ahn, Hye-Sil (Water Supply and Sewerage Research Division, National Institute of Environmental Research)
Seo, Kyoung-Ae (Water Supply and Sewerage Research Division, National Institute of Environmental Research)
Park, Ju-Hyun (Water Supply and Sewerage Research Division, National Institute of Environmental Research)
Lee, Jun-Bae (Water Supply and Sewerage Research Division, National Institute of Environmental Research)
Kim, Tae-Seung (Geum River Environment Research Center, Director, National Institute of Environmental Research)
Han, Jin-Seok (Water Supply and Sewerage Research Division, National Institute of Environmental Research)
Kwon, Oh-Sang (Water Supply and Sewerage Research Division, National Institute of Environmental Research)
Publication Information
Analytical Science and Technology / v.24, no.1, 2011 , pp. 10-14 More about this Journal
Abstract
This study was performed to compare international analytical methods of bromide and applied to determine bromide in bottled mineral water and raw ground water in Korea. Bromide in water was eluted by 10~50 mM potassium hydroxide (KOH) and determined by ion chromatography-suppressed conductivity detector (IC-CD). Sample was purified with Ba- and H-on-guard cartridge and $0.2\;{\mu}m$ membrane filter. The method detection limit (MDL) and the limit of quantitation (LOQ) of bromide were 0.2 and $0.5\;{\mu}g/L$, respectively. The calibration curve showed good lineality above 0.9993 in the ranges of the $0.5\sim80\;{\mu}g/L$. A correlation coefficient of bromide in ground water and sum of bromide and bromate in bottled mineral water is 0.808.
Keywords
bromide; IC-CD; bottled mineral water; ground water;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 US EPA, 'EPA method 317.0 Determination of Inorganic Oxyhalide Disinfection By-products in Drinking Water Using Ion Chromatography with the Addition of a Postcolumn Reagent for Trace Bromate Analysis' Washington DC, US Environmental Protection Agency, 2001.
2 US EPA, 'EPA method 326.1 Determination of Inorganic Oxyhalide Disinfection By-products in Drinking Water Using Ion Chromatography Incorporating the Addition of a Suppressor Acidified Postcolumn Reagent for Trace Bromate Analysis', Washington DC, US Environmental Protection Agency, 2002.
3 R. Michalski, Polish J. of Environ. Studies, 14(3), 257-268(2005).
4 한국표준협회, 'KS I ISO 10304-1, 수질-이온 액체크로마토그래피를 이용한 용존된 불화물, 염화물, 아질산염, 오르토인산염, 브롬화물, 질산염과 황산염 이온의 측정-제1부: 오염이 적은 물에 대한 방법', 2006.
5 안혜실, 김현구, 박주현, 정동일, 김태승, 한국분석과학회지, 23(2), 155-160(2009).
6 Rodney, S. Magazinovic, Brenton, C. Nicholson, Dennis, E. Mulcahy and David, E. Davey, Chemosphere 57, 329-335(2004).   DOI   ScienceOn
7 IARC, 'Agents Reviewed by the IARC Monographs', 1-100A(2009).
8 US EPA, Fed. Reg. 68(159), 49647, 2003.
9 WHO, 'Guidelines for Drinking Water Quality', Geneva, Switzerland, 2008.
10 M. Manassis and S. Constantinos, Ozone science & engineering, 25, 167-175(2002).
11 US EPA, 'EPA method 300.1 The determination of Inorganic Anions in Water by Ion Chromatography' Washington DC, US Environmental Protection Agency, 1997.