• Title/Summary/Keyword: 캔틸레버

Search Result 260, Processing Time 0.023 seconds

Free Vibrations of Tapered Cantilever Arches with Variable Curvature (변단면 변화곡율 캔틸레버 아치의 자유진동)

  • 이병구;이용수;오상진
    • Journal of KSNVE
    • /
    • v.10 no.2
    • /
    • pp.353-360
    • /
    • 2000
  • Numerical methods are developed for calculating the natural frequencies and mode shapes of the tapered cantilever arches with variable curvature. The differential equations governing the free vibrations of such arches are derived and solved numerically, in which the effect of rotatory inertia is included. The parabolic shape is chosen as the arch with variable curvature while both the prime and quadratic arched members are considered as the tapered arch with variable curvature while both the prime and quadratic arched members are considered as the tapered arch. Comparisons the natural jfrequencies between this study and finite element method SAP 90 seve to validate the numerical method developed herein. The lowest four natural frequencies are reported as a function of four non-dimensional system parameters. The effects of both the rotatory inertia and cross-sectional shape are reported. Also, the typical mode shapes of stress resultants as well as the displacements are reported.

  • PDF

Critical Loads of Tapered Cantilever Columns with a Tip Mass (자유단 집중질량을 갖는 변단면 캔틸레버 기둥의 임계하중)

  • Jeong, Jin Seob;Lee, Byoung Koo;Kim, Gwon Sik;Kim, Jong Ung
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.699-705
    • /
    • 2005
  • This paper investigates critical loads of tapered cantilever columns with a tip mass, subjected to a follower force. The linearly tapered solid rectangular cross-sections are adopted as the column taper. The differential equation governing free vibrations of such columns, also called Beck's columns, is derived using the Bernoulli-Euler beam theory. Both divergence and flutter critical loads are calculated from the load-frequency curves that are obtained by solving the differential equation. The critical loads are presented as functions of various non-dimensional system parameters, namely, the taper type, the subtangential parameter, and the mass ratio.

Effects of Material Characteristics on the Time-dependant Behavior of Prestressed Concrete Box Girder Bridges Constructed by Free Cantilever Method (재료특성치의 변화에 따른 캔틸레버 공법 프리스트레스트 콘크리트 박스거더 교량의 장기거동 분석)

  • 오병환;양인환
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.179-188
    • /
    • 1998
  • 캔틸레버 공법으로 시공되는 프리스트레스트 콘크리트 박스거더 교량의 구조적 거동은 단계적 시공에 따른 구조물의 순차적 변화 및 콘크리트의 재료적 특성에 의해 시간 의존적 거동을 나타낸다. 콘크리트의 시간의존적 특성, 즉 콘크리트의 크리프 및 건조수축 특성은 현장타설 세그멘탈 캔딜레버공법으로 가설되는 콘크리트 교량의 설계 및 시공에서 매우 중요한 역할을 한다. 본 연구에서는 콘크리트의 크리프 및 건조수축 특성이 교량의 시간의존적 거동, 특히 처짐 및 텐던응력예측에 미치는 영향을 연구하였다. 교량해석은 본 연구진에 의해 개발된 프리스트레스트 콘크리트 교량해석기법 및 프로그램을 이용하여 크리프의 ACI 모델, CEB-FIB모델, 그리고 국내 도로교 시방서 모델을 고려하여 해석하였다. 해석결과 최종크리프 값의 크기에 따라 장기처짐의 발생량이 차이가 큰 것으로 나타나고 있으며, 최종건조수축량과 상대습도도 영향을 주는 것으로 나타났다. 또한 ACI 모델과 CEB-FIB모델간에도 차이가 큰 것으로 나타나 실제교량의 크리프 특성 및 건조수축 특성의 정확한 예측이 교량의 정밀시공 및 거동예측에 매우 중요한 것으로 나타나고 있다.

A Study on the Development of a Cantilever & Swing-Type Fast Tool Servo with Rotational Moment Hinge Design (회전모멘트 힌지 설계에 따른 캔틸레버형 횡방향 구동 Fast Tool Servo 연구 개발에 관한 고찰)

  • Lee, Seung Jun;Jeong, Jae Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.8
    • /
    • pp.43-49
    • /
    • 2020
  • The growth of the AR/VR market due to the advent of the 4th Industrial Revolution begins with the development of the display industry. The development of OLED and flexible displays is further accelerated by the development of R2R technology. Micro-processing technology using a fast tool servo (FTS), the core technology in R2R processes, is making technological progress in increasingly diverse ways. This paper proposes a method to develop an FTS for horizontal driving and presents this method through experiments and analyses. To develop a swing-type FTS based on a seesaw motion, a rotational moment hinge structure was designed for each type, and research was conducted to determine an effective design method. A cantilever-based swing-type FTS was developed in two variations: one with single-side hinges and another with dual-side hinges. The parameters in the design of the swing-type FTS are rotational moment, natural frequency, and material selection. In conclusion, an FTS with a single-side hinge demonstrates the high performance required for micro processing.

Vibration Characteristics and Performance of Cantilever for Non-contact Atomic Force Microscopy (비접촉 원자간력 현미경의 탐침 캔틸레버 진동 특성 및 측정 성능 평가)

  • 박준기;권현규;홍성욱
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.6
    • /
    • pp.495-502
    • /
    • 2004
  • This paper presents the vibration analysis and the performance evaluation of cantilevers with probing tips for non-contact scanning probe microscopy. One of the current issues of the scanning probe microscopy technology is to increase the measurement speed, which is closely tied with the dynamic characteristics of cantilevers. The primary concern in this research is to investigate the relation between the maximum possible speed of non-contact scanning probe microscopy and the dynamic characteristics of cantilevers. First, the finite element analysis is made for the vibration characteristics of various cantilevers in use. The computed natural frequencies of the cantilevers are in good agreement with measured ones. Then, each cantilever is tested with topographic measurement for a standard sample with the scanning speed changed. The performances of cantilevers are analyzed along with the natural frequencies of cantilevers. Experiments are also performed to test the effects of how to attach cantilevers in the piezo-electric actuator. Finally, measurement sensitivity has been analyzed to enhance the performance of scanning probe microscopy.

Design and Implementation of the Diseases Diagnosis System Using The Cantilever Micro-Arrays (박막 캔틸레버 어레이 센서를 이용한 질병 진단기 설계 및 구현)

  • Jung, Seung-Pyo;Choi, Jun-Kyu;Lee, Jung-Hoon;Park, Ju-Sung
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • The disease diagnosis system has been developed using the thin nitride(Si3N4) cantilever arrays which can measure the difference of capacitances between sensor and reference. The system consists of 32-bits RISC(Reduced Instruction Set Computer), RAM/Flash, bus, communication IP's, ADC(Analog Digital Converter) board, and LCD display. The marker selection method, which give us the good accuracy from reasonal numbers of markers, is suggested. The developed system has the resolution under 1fF and can detect 10nM concentration of Thrombin.

DNA Selective Immobilization on a Microcantilever with Nano-Interdigitated Electrodes (Nano-IDEs) Using Cyclic Voltammetry (맞물린 나노전극을 가지는 마이크로 캔틸레버의 제작 및 순환전압전류방법을 이용한 DNA의 선택적인 고정화)

  • Lee, Jung-A;Lee, Kwang-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.6
    • /
    • pp.459-464
    • /
    • 2008
  • We present a novel microcantilever device with nano-interdigitated electrodes (nano-IDEs) and DNA selective immobilization on the nano-IDEs for biosensing applications. Using the nano-IDEs and cyclic voltammetric methods, we have achieved selective immobilization of DNA with submicrometer spatial resolution on a freestanding microcantilever. $70{\sim}500\;nm$-wide gold (Au) nano-IDEs are fabricated on a low-stress SiNx microcantilever with dimensions of $100{\sim}600\;{\mu}m$ in length, and $15{\sim}60\;{\mu}m$ in width, with a $0.5\;{\mu}m$ thickness using electron beam lithography and bulk micromachining. Streptavidin is selectively deposited on one side of the nano-IDEs using cyclic voltammetry at a scan rate of 0.1 V/s with a range of $-0.2{\sim}0.7\;V$ during $1{\sim}5$ cycles. The selective deposition of dsDNA is confirmed by fluorescence microscopy after labeling with YOYO-1 dye.