• Title/Summary/Keyword: 침-평판

Search Result 19, Processing Time 0.024 seconds

Technique of Transformer Diagnosis Using Ultrasonic Sensor (초음파 센서를 이용한 변압기 예방진단 기술 연구)

  • 권동진;최수안;박형준;곽희로;정찬수;전희종;김재철
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.2
    • /
    • pp.46-53
    • /
    • 1994
  • This paper presents a diagnosis teclmique using ultrasonic sensors for monitoring the growth of partial discharge in power transformers. This teclmique counts the ultrasonic pulses generated from partial discharge over a threshold leveL In experiments, a ultrasonic generator and the point to plane electrodes generated ultrasonic pulses. With a constant voltage between the electrodes, the ultrasonic pulses over a threshold were a fairly constant. When the voltage increased or insulation paper was inserted between the electrodes, the partial discharge increased. In this case the number of ultrasonic pulses also increased and therefore the proposed teclmiques successfully diagnosed the growth of partial discharge.

  • PDF

Numerical Simulation of Nitrogen Discharge at Medium Pressure between Point-Plane Electrodes (침-평판 전극 사이에서 중간 압력 질소 방전의 시뮬레이션)

  • Koh, Wook-Hee;Park, In-Ho
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.487-494
    • /
    • 2008
  • The numerical simulation of point-to-plane discharge of nitrogen at medium pressure has been achieved by a quasi-2d numerical model. In the model, we calculate the distributions of electric charges which are varying as temporal and space and determine the electric field depending on space charge distribution by solving Poisson's equation. The continuity equations are treated numerically by using FCT (Flux-Corrected Transport) Algorithm and FEM (Finite Element Method). The numerical simulation results make us to understand the physical characteristics of nitrogen discharge at 50 torr. The comparison with experimental results[1] shows a good qualitative agreement.

Characteristics of ionic Wind in a DC Corona Discharge in Needle-to-punched plate Geometry (침 대 중공평판전극에서 직류코로나 방전에 의한 이온풍 특성)

  • Lee, Bok-Hee;Kil, Hyeong-Joon;Eom, Ju-Hong;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.74-80
    • /
    • 2003
  • Ionic wind is produced by a corona discharge when a DC high voltage is applied across the point-to-plane gap geometry. The corona discharge phenomena have been investigated in several beneficial application fields such as electrostatic cooling, ozone generation, electrostatic precipitation and electrostatic spraying. Recently ionic wind might be used in aerodynamic, for example, heat transfer, airflow modification, and etc. In this work, in order to analyze the control behavior of the velocity and amount of ionic wind produced by the positive DC corona discharges. The ionic wind velocity was measured as a function of the applied voltage, diameter of the punched hole on plate electrode and separation between the point-to-plate electrodes. As a results, the airflow is generated from the tip of needle to the plate electrode in the needle-to-punched-plate electrode systems. The ionic wind velocity is linearly increased with an increase in applied voltage and ranges from 1 to 3 m/sec at the locations of 100-200 mm from the punched-plate.

Comparison of Artificial Neural Network for Partial Discharge Diagnosis (부분방전 진단을 위한 인공신경망 기법의 비교)

  • Chung, Gyo-Bum;Kwack, Sun-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4455-4461
    • /
    • 2013
  • This paper investigates the diagnosis performance of Artificial Neural Network (ANN) depending on the structure and the input vector type of ANN, which has been used to detect the partial discharge to lead to the electric machinery deterioration. The diagnosis performance of one hidden layer and two hidden layer in ANN are compared. The performance using the 2048 time-series data and the performance using the feature input vector are compared. For measuring the partial discharge signal, the tip-to-plate, the sphere-to-sphere, the tip-to-tip, the tip-to-sphere and the sphere-to-plate electrodes are used respectively. For ANN's learning, Matlab and C-code program are used. For evaluating the diagnosis performance of ANNs, the simulation studies are performed.

Surface Discharge Characteristics for Epoxy Resin in Dry-Air with Variations of Electrode Features and Epoxy Resin Size (Dry-Air 중의 전극 형상 및 에폭시수지의 크기변화에 따른 연면방전특성 연구)

  • Park, He-Rie;Choi, Eun-Hyeok;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.154-160
    • /
    • 2009
  • This paper shows a basic data of the surface discharge characteristics for epoxy resin in Dry-Air as being focused on environmentally friendly insulating Gas. Used electrodes are needle to plane, sphere to plane and KS M3015 electrodes. With the changing electrodes in same condition, we can obtain different creeping lengths, surface discharge voltages and surface dielectric strengths, respectively. Surface dielectric strengths of Needle to plane electrodes are more higher than the others. Moreover, it is considered that the surface discharge characteristics with variation of epoxy resin thickness and diameter. Surface discharge voltage increases as the thickness and the diameter of epoxy resin.

The Characteristic of Hydrogen Generation on the Structure of Plasma Reactor Using the Streamer Discharge in the Water (수중 스트리머 방전용 플라즈마 반응기 구조에서 수소발생 특성)

  • Park, Jae-Youn;Kim, Jong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.37-42
    • /
    • 2006
  • The effect of arc like streamer discharge is investigated on the hydrogen generation using the multineedle-plate electrode geometry plasma realtor(MPER) and the needle-plate electrode geometry plasma reactor(NPER). In order to restrict waves at the water surface when the high voltage applied, two kinds of the insulator such as the rectangular mesh or the hole mesh type are installed under the water surface. The discharge assistant of the two type(the saw type and the $TiO_2$ pellet type) was placed under the water surface to investigate the effect of the water surface conditions. The experimental results are compared in case of the reactor with and without the discharge assistant on the water surface.

Discharge Characteristics between Needle and Plane Electrodes in Water under Impulse Voltages (임펄스전압에 의한 침 대 평판전극에서 수중방전특성)

  • Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.67-74
    • /
    • 2008
  • In this paper we describe discharge characteristics between needle-to-plane electrodes in water in various conditions such as different impulse voltages, polarities and water resistivities. Streamer corona is initiated at the tip of needle electrode and propagates toward plane electrode, and it experiences the final jump across the test gap. The branched channels of streamer coronas for lower water resistivities are much thicker and brighter than those for higher water resistivities at the same level of applied voltage. The negative streamer coronas not only have more branches but also widely spread out compared to the positive streamer coronas. A number of pulse-like currents ranging from some hundreds mA to a few A after streamer corona onset were produced with discharge developments. The time-lags-to breakdown for the positive polarity were remarkably shorter than those for the negative polarity. The pre-breakdown energy supplied into the test gap was inversely proportional to water resistivity.

Electrical Treeing Deterioration and Dielectric Breakdown Phenomena in Polymeric Insulator (고분자 절연재료에서 전기트리 열화 및 절연파괴 현상)

  • Cho, Yeong-Sin;Kim, Sang-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.398-403
    • /
    • 1999
  • Studies on the electrical treeing deterioration and dielectric breakdown phenomena in the polymeric insulator of polyethylene and epoxy resin were carried out. Block type samples with needle-plane electrode geometry were electrically stressed and the tree pattern from the needle tip was observed. In LDPE the density of electrical tree was very high and its pattern was bush type. For the case of XLPE, branched tree was observed. As temperature and SN content increased, the dielectric breakdown voltage decreased and the treeing phenomena became more complicated. Fan type cracks were observed around the conducting tree path in the brittle DGEBA/MDA system.

  • PDF

Detection and Analysis of Partial Discharges in Insulation Oil by a Monopole Antenna (모노폴 안테나에 의한 유중 부분방전의 검출과 분석)

  • Park, Dae-Won;Lee, Jung-Yoon;Kim, Min-Su;Kil, Gyung-Suk;Cheon, Sang-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.69-69
    • /
    • 2011
  • 본 논문에서는 유입변압기의 절연진단을 위한 기초연구로 유중 부분방전에 의해 발생하는 전자파의 검출과 분석에 대하여 기술하였다. 유중 방사전자파 측정에는 공진주파수가 1 GHz인 모노폴 안테나를 제작하였다. 절연유 내부에 침-평판 전극계를 설치하고 0~50 kV까지 고전압을 인가시키면서 유중 부분방전의 발생을 모의하였다. 실험결과, 92.3 pC의 부분방전 발생시 1.28 V의 신호가 검출되었다.

  • PDF

Detection and Analysis of Partial Discharges in Insulation Oil by a Monopole Antenna (마이크로폰을 이용한 코로나 방전의 측정 및 분석)

  • Cho, Hyang-Eun;Park, Dae-Won;Kim, Min-Su;Kil, Gyung-Suk;Cheon, Sang-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.68-68
    • /
    • 2011
  • 본 논문에서는 수배전반의 상태진단을 위하여 코로나 방전에 의해 발생하는 음향신호의 측정 및 분석에 대하여 기술하였다. 침-평판 전극계를 제작하여 코로나 방전을 모의하였으며 음향신호의 측정에는 감도 4 mV/Pa, -3 dB의 주파수 대역이 4 Hz~100 kHz인 마이크로폰을 사용하였다. 코로나 방전에 의한 음향신호의 주파수 분석결과, 주파수 성분은 10 kHz~80 kHz에 분포하였으며 20 kHz~40 kHz의 성분이 가장 우세하게 나타났다.

  • PDF