• Title/Summary/Keyword: 침하판

Search Result 42, Processing Time 0.027 seconds

A Study on the Behavior of Piled Raft Foundation Using Triaxial Compression Apparatus (삼축압축 시험기를 이용한 말뚝 지지 전면 기초 거동 연구)

  • 이영생;홍승현
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.387-395
    • /
    • 2003
  • Model tests were conducted to study the behavior of the piled raft foundation system on sands. Especially in this study, the method using the triaxial compression apparatus was devised and used to apply the confining pressure which is considered difficult in the existing model test on the soil. Steel rods (6mm dia.) and aluminum plates (8mm thickness, 50mm dia.) were used to simulate piles and rafts respectively. Jumunjin standard sands were used to ensure the homogeneity of the sample. After the sample with the piled raft model was laid inside the triaxial cell, the confining pressure was applied and then the compressive force was applied. The increase and/or decrease ratio of the bearing capacity, the load distribution ratio between raft and piles and the effect of settlements decrease depending on the confining pressure, the number of piles and the length of piles were analyzed and the bearing capacity and skin friction of the pile was calculated. By the results of these experiments, the bearing capacity increased and the settlement decreased with this piled raft foundation system. Especially the effect was larger with the increase of the number of piles than with the increase of length of piles. Hereafter, the study of the load transfer mechanism of piles under confining pressure would be made possible using these small model tester like triaxial compression apparatus.

Stress analysis of large ground-supported cylindrical storage tanks (地盤支持된 大形圓筒탱크의 應力解析)

  • 김동현;차홍석;윤갑영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.976-981
    • /
    • 1986
  • The Stress analysis based on the large deflection theory of plate for the large cylindrical storage tank is performed by considering the change of membrane force for the various parameter, i.e., thickness ratio, tank height to diameter ratio, and stretched length. The critical buckling force of cylindrical shell is obtained to investigate the safety of tank shell. By numerical result, the thickness ratio is the important parameter for the membrane force, the height of tank is related linearly with the force, and the stretched length of bottom plate is little influenced. Also, the critical buckling force of cylindrical shell is large than the edge shear force at bottom-shell junction, and hence the consideration of the shell buckling is not required.

Strength Evaluation of I-Type Connecting System on a Segmental Retaining Reinforced Wall Consideration the Backfill Settlement (배면침하 영향을 고려한 보강토 옹벽의 I형 연결시스템 강도 평가)

  • Moon, Hee-Jung;Han, Jung-Geun;Lee, Jong-Young;Cho, Sam-Deok;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.1
    • /
    • pp.27-32
    • /
    • 2007
  • This paper describes the applicability of geogrid with I-type coupling system, which permits vertical displacement on back fill ground of the reinforced retaining wall and also minimize the damage between block and geogrid. The improvement of coupling method allowed the reduction of approximately 700 mm in the existing geogrid, and as a result, the tensile strength at the coupling joint showed approximately 53% of the maximum tensile strength. It is expected from the laboratory investigations that the coupling strength of geogrid with the combination of in-situ supporting material should be predominant in the field condition.

  • PDF

Treatment of Canine Cervical and Lumbar Disc Disease by Injection-Acupuncture (개 경부 및 요부 디스크의 수침치료)

  • Kim Duck-Hwan;Liu Jian-Zhu;Lee Young-Won;Song Kun-Ho;Kang Sang-Kyu;Choi Ho-Jung;Seo Kang-Moon;Choi Seok-Hwa;Nam Tchi-Chou;Rogers Phil A.M.
    • Journal of Veterinary Clinics
    • /
    • v.23 no.1
    • /
    • pp.65-68
    • /
    • 2006
  • Two cases of canine intervertebral disc disease (IVDD) were treated twice a week with injection-acupuncture (injection-AP) using 0.1 ml/acupoint. In case 1, a paralysed dog with cervical intervertebral disc disease (C3-C4), was submitted to injection-AP with dexamethasone (1 mg/ml) at session 1-2 and thiamine (25 mg/ml) at session 3-5. Injected acupoints included GV-16, GB-20, BL-10, LU-7, LI-4 and SI-6. The acupoints GV-6, GV-20 and SP-6 were added at session 2-5. Trigger point (TP) therapy with 0.2 ml of 2% lidocaine was used in session 3-5 at TP in the infraspinatus and triceps muscles. Treatment was stopped when paralysis disappeared after 5 injection-AP treatments; there were no recurrent symptoms in the follow-up period of 5 months. In case 2, an ataxic dog with lumbar IVDD (L1-L2), was submitted to injection-AP with dexamethasone at session 1 and 2 and thiamine at session 3-4. Injected acupoints included GV-6 as the main point, ST-36, GB-30, ST-40, GB-34, ST-41 and BL-40. TP therapy with 0.2 ml of 2% lidocaine was used at TP in the ileocostorum lumborum and quadriceps muscles. Treatment was stopped when ataxia disappeared after 4 treatments; there were no recurrent symptoms In the fallow-up period of 5 months. Injection-AP using dexamethasone and thiamine, combined with TP therapy using lidocaine, effectively alleviate the symptoms of canine cervical and lumbar IVDD.

An Experimental Study on Behavior Characteristics of the Pretension Soil Nailing Systems (프리텐션 쏘일네일링 시스템의 거동특성에 관한 실험적 고찰)

  • Choi, Young-Geun;Shin, Bang-Woong;Park, Si-Sam;Kim, Hong-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • Application of the soil nailing method is continuously extending in maintaining stable excavations and slopes. However, ground anchor support system occasionally may not be used because of space limitations in urban excavation sites nearby the existing structures. In this case, soil nailing system with relatively short length of nails could be efficiently adopted as an alternative method. The general soil nailing support system, however, may result in excessive deformations particularly in an excavation zone of the existing weak subsoils. Pretensioning the soil nails then could play important roles to reduce deformations mainly in an upper part of the nailed-soil excavation system as well as to improve local stability. In this study, a newly modified soil nailing technology named as the PSN (Pretension Soil Nailing) is developed to reduce both facing displacements and ground surface settlements in top-down excavation process as well as to increase the global stability. Up to now, the PSN system has been investigated mainly focusing on an establishment of the design procedure. In the present study, laboratory model tests are carried out to investigate the failure mechanism and behavior characteristics of the PSN system. Various results of model tests are also analyzed to provide a fundamental basis for the efficient design.

A Study on the Negative Skin Friction based on Measurements from Existing Works Analysed by 3D Finite Element Analyses (기발표 실측치 분석을 기반으로 한 3차원 유한요소해석 수행을 통한 부마찰에 관한 연구)

  • Jeon, Sang Joon;Jeon, Young Jin;Jeon, Seung Chan;Lee, Cheol Ju
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.8
    • /
    • pp.15-27
    • /
    • 2020
  • In the current paper, a series of advanced 3D finite element analyses have been performed on existing pieces of work of negative skin friction from a geotechnical centrifuge test and full-scale field measurements. From these analyses, key features of pile behaviour under the influence of negative skin friction which, previously, were not fully understood in existing studies, have been meticulously discussed. As such, it has been possible to successfully address several numerical modelling issues such as negative skin friction induced pile settlements and group effects (the shielding effect), the effect of sacrificial piles in groups and the interaction between the pile head and the cap, the effect of interface elements at the pile-soil interface and the time-dependent pile behaviour. During a geotechnical centrifuge test, substantial amounts of negative skin frictions were mobilised when centrifugal acceleration increased from 1g to a certain g-level due to an increase in the self-weight of soil. The behaviour of piles inside a group were heavily affected by the sacrificial piles and the connectivity between the pile head and the pile cap. In particular, as negative skin friction has time dependent qualities associated with consolidation, it was logical to perform coupled analyses when analysing piles in consolidating grounds. From the current work, several insufficiencies of previous researches have been addressed, and the engineering pile behaviour subjected to negative skin friction has been clarified.

A Study on Prediction of Moment Developed in Bottom of Foundations between Pile and Heterogeneous Soils (말뚝기초와 이질지반 경계부 기초저판에서의 발생모멘트 예측에 관한 연구)

  • Lim, Hae-Sik;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.277-285
    • /
    • 2011
  • To reinforce bearing capacity-changed section or different foundation in the same building, empirical or simple tools have been used. To solve this problem, an analytical solution which can evaluate and reinforce the stability of foundation is introduced. To suggest a clue for the problems, current foundation reinforcing method is studied through recent literature studies and the structural analyses of foundation slab are performed on the pile foundation of 49$m^2$, 59$m^2$ and 84$m^2$ I type apartments in 15 story building. The analyses are conducted with SAP 2000, a computer program for ordinary structural analysis. To predict the moments of slab by ground non-uniformity, the structural analysis results for the foundation slab of 3 types 15 story apartment buildings in 49$m^2$, 59$m^2$ and 84$m^2$ I type on non-uniformity ground are shown in the diagrams.

A Study on the Cut-slope Maintenance according to Anchor Tension Force (앵커 긴장력 변화에 따른 비탈면 유지관리 연구)

  • Park, Byungsuk;Kim, Wooseok;Hwang, Sungpil;Kwon, Oil
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.673-682
    • /
    • 2020
  • The ground shear force at the expected failure surface and resistance force due to reinforced anchor can act as important factors according to a failure type from the stability viewpoint at a slope. Furthermore, the anchor's axial force may vary at an anchor-reinforced slope due to ground weathering, settlement, and corrosion in the incompletely anti-corrosion treated steel wire strand at a ground where the bearing plate is installed. However, in case that the resistance force of the anchor is locally lost due to the variation of the anchor's axial force, the resistance force may not play the role so that the external force tends to be transferred to the surrounding anchors, causing an increase in the tensile force in the surrounding anchors. Accordingly, a stability problem at the entire slope may occur, which requires much attention. Thus, this study proposed a method to monitor a variation trend of the tensile force of anchors installed at a slope and infer the external stability at the entire slope considering the monitoring result.

An Assessment on the Urban Riverfront in Shincheon, Daegu - Focused on a Universal Design Concept - (대구광역시 신천의 친수공간 평가 연구 - 유니버설디자인 개념을 중심으로 -)

  • Choi, Dong-Sik;Moon, Ji-Won;Kim, Shang-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.1-14
    • /
    • 2012
  • The purpose of this study is to derive a desirable riverfront construction plan to me for the activities of citizens through the evaluation and analysis of the urban riverfront space from the perspective of universal design. Therefore, previous studies were examined in order to induce evaluation tools that bhve been grafted from the universal design concept; in addition, a field survey was conducted in Shincheon, Daegu, which was selected as the study target, in order to induce problems and improvement directions from the perspective of universal design. The major results can be summarized as follows. (1) In the 'fairness' aspect, all the items such as installation of integrated functional signage, showing pictures, symbols, foreign language signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; and therefore, it is necessary to improve the fairness of usage for everybody. (2) In the 'Functionality(Usability)' aspect, all items such as installation of bicycle paths beside access roads, installation of integrated functional signs, and night light signs were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the functionalities of these facilities. (3) In the 'Convenience' aspect, all items such as the installation of bicycle parking areas, continuous rest facilities, and back and ann support(handles) at resting facilities were determined to be 'All Unsuitable' for many sections; therefore, it is necessary to improve these facilities for the convenience of usage. (4) In the 'Information(Recognizability)' aspect, all items such as showing pictures, symbols, foreign languages and installation of night light signs, and restroom entrances signage were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the recognizability to minimize misunderstandings and confusion. (5) In the 'Safety' aspect, all items such as the installation of safe pedestrian paths in parking areas, using anti-slip and shock absorption materials on restroom floors, and the continuous installation of pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the safety to prevent accidents. (6) In the 'Amenity' aspect, access roads, parking areas, hygiene facilities, convenience facilities, and waterside facilities for many sections were determined to be 'All Unsuitable'; therefore, it is necessary to conduct more concentrated hygiene management. (7) In the 'Accessibility(Mobility)' aspect, all items such as the installation of safe pedestrian paths in parking areas, and continuous pedestrian paths that are separate from bicycle paths were determined to be 'All Unsuitable' for all sections; therefore, it is necessary to improve the accessibility to provide safety and convenience. (8) In the 'Durability' aspect, access roads, parking areas, rest facilities, convenience facilities, fitness facilities, and waterside facilities were determined to be 'All Unsuitable' for many sections, therefore, it is necessary to improve sunken or damaged areas by inspecting facilities by section.

Effects of Soil Pysical Properties on Workability of Agricultural Machineries in Paddy Field (논토양(土壤)의 물리성(物理性)이 농기계(農機械) 작업능률(作業能率)에 미치는 영향(影響))

  • Jo, In-Sang;Kim, Lee-Yul;Cho, Yeong-Kil;Im, Jeong-Nam;Um, Ki-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 1984
  • This study was conducted to find out the effects of soil physical properties on workability of farm machines in the paddy fields. Various soil physical properties, workability of cultivator and tractor were investigated at three different textured soils and three levels of soil moisture conditions. The results are summarized as follows: 1. Soil strength, shear and friction resistance, plate sinkage, wheel and footprint sinkage, and slippage were greatly affected by the soil texture and moisture conditions, and the workabilities were changed by the soil physical properties. 2. Cultivator workability were high values at the range of soil shear resistance $200-450g/cm^2$, and cultivator or tractor working was difficult at below $200g/cm^2$ of the shear resistance. 3. The favorable range of soil strength for tractor working was $8-12kg/cm^2$, and $6-10kg/cm^2$ for cultivator. 4. Footprint sinkage was closely related to the values obtained by testers. It's optimum range for cultivator was 1-2cm, and tractor workability was increased by decreasing the footprint sinkage.

  • PDF