• Title/Summary/Keyword: 침전지

Search Result 129, Processing Time 0.028 seconds

Economic Design of Activated Sludge System at the Optimum Sludge Concentration (슬러지 농도 최적화에 따른 합리적인 활성슬러지공정 설계방안 연구)

  • Lee, Byung Joon;Choi, Yun Young
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.5
    • /
    • pp.483-490
    • /
    • 2014
  • The design procedures for a biological reactor and a secondary settling tank (SST) of an activated sludge system are based on the steady state design method (Ekama et al., 1986; WRC, 1984) and the 1-D flux theory design method (Ekama et al., 1997), respectively. This study combined both of the design procedures, to determine the optimum sludge concentration in the reactor and the best design with the lowest cost. The best design of the reactor volume and the SST diameter at the optimum sludge concentration were specified with varying wastewater and sludge characteristics, temperature, sludge retention time (SRT) and peak flow rate. The effects of the influent wastewater characteristics, such as substrate concentration and unbiodegradable particulate fraction, were found to be considerable, but the effect of unbiodegradable soluble fraction was to be negligible. The effects of sludge settling characteristics, were also significant. SRT, as an operating parameter, was found to be an important factor for determining the optimum sludge concentration. However, the effect of temperature was found to be small. Furthermore, for designing a large scale wastewater treatment plant, the number of reactors or SSTs could be estimated, by dividing the total reactor volume or SST area. The new combined design procedure, proposed in this research, will be able to allow engineers to provide the best design of an activated sludge system with the lowest cost.

The Analysis of Coagulation Effect in the Water Treatment Plant by Input of Micro-Particles having Different Specific Gravity (비중이 다른 미세입자의 투입에 따른 정수장의 응집 효과 분석)

  • Kwon, Young-Bin;Choi, Gye-Woon;Lee, Joo-Kyoung;Park, Hyo-Seon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.673-677
    • /
    • 2009
  • 현재 상수시설의 경우 갈수록 악화되는 수질과 정수장의 유지관리 인원 상주의 어려움, 기존의 응집, 침전, 여과 정수처리 시스템의 처리성능 증대에 따른 한계성에 직면한 상황이다. 안정적으로 수질의 개선을 통한 장치의 컴팩트화, 유지관리가 편리한 고도정수 수질기준에 만족하는 정수처리 시스템이 필요하다. 본 연구에서는 기존의 정수처리 시설인 혼화지에 응집제와 함께 다양한 비중을 가지고 있는 모래입자를 투입하여 응집제와 모래의 결합에 따른 탁도 제거효율과 슬러지의 양을 비교하였으며, 침전지내에 정류벽을 설치하여 침전지 초반에 가라앉을 수 있도록 유도하여 탁도 및 슬러지양을 비교하였다. 응집제만 투입한 경우보다 시료를 투입한 경우가 탁도제거율과 슬러지양이 상승하는 것을 볼 수 있으며 그중에서도 규사의 경우가 가장 많은 탁도제거율의 상승을 나타냈다. 또한 이중 정류벽을 설치하여 탁도 및 슬러지양을 측정한 결과 이중정류벽을 설치하지 않은 경우보다 탁도제거율 및 슬러지양 또한 높게 측정되었으며 슬러지의 양 또한 침전지 앞부분에 집중되는 것으로 나타났다. 이러한 경우 상기 플럭의 질량이 증가하기 때문에 처리속도를 높이고, 체류시간을 줄이고, 처리를 효율적으로 안정되게 수행하는 것이 가능하다. 본 연구결과를 바탕으로 정수시설의 설치에 있어 시료와 이중정류벽을 함께 사용할 경우 응집제의 절감 또는 침전지의 컴팩트화를 가져올 것으로 예상된다.

  • PDF

Turbidity Reduction for Construction Runoff Using Polyacrylamide (고분자응집제를 이용한 건설현장 탁수처리)

  • Kang, Ji-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.237-241
    • /
    • 2012
  • 많은 건설사업장의 경우 토사 유출에 따른 고농도 탁수가 발생하며, 그 탁도를 낮추기 위해 침전지 혹은 토사탈수백 등의 Best Management Practices(BMPs)를 이용한다. 본 연구에서는 유입되는 탁수에 고분자응집제인 polyacrylamide(PAM)를 액상으로 주입하고, 침전지와 토사탈수백을 통해 탁도를 저감하는 field-scale 실험을 수행하였다. 일반적으로 침전지 중간에는 유입되는 물의 힘을 분산시키기 위해 배플이라는 구조물이 설치되는데, 본 연구결과에 따르면 PAM을 통한 화학적 처리 없이 배플 자체로는 탁도를 낮추는 데 그 효과가 낮았으나, PAM주입을 할 경우 배플 설치 여부에 상관없이 90-98%까지 방류수 탁도를 낮출 수 있는 것으로 나타났다. 침사지 이후에 설치한 토사탈수 백은 그 효과가 낮았으나, 침사지 없이 토사탈수백만 사용할 경우 PAM을 이용한 화학적 처리 없이는 만족할 만한 방류수 탁도를 기대하기 어려웠다. 본 연구결과는 향후 미국에서 면적 10에이커 이상의 공사현장에 적용되는 탁도 규제에 대한 대응 방안으로 PAM을 이용한 탁수 처리의 효용성을 보여준다.

  • PDF

Machine learning model for residual chlorine prediction in sediment basin to control pre-chlorination in water treatment plant (정수장 전염소 공정제어를 위한 침전지 잔류염소농도 예측 머신러닝 모형)

  • Kim, Juhwan;Lee, Kyunghyuk;Kim, Soojun;Kim, Kyunghun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1283-1293
    • /
    • 2022
  • The purpose of this study is to predict residual chlorine in order to maintain stable residual chlorine concentration in sedimentation basin by using artificial intelligence algorithms in water treatment process employing pre-chlorination. Available water quantity and quality data are collected and analyzed statistically to apply into mathematical multiple regression and artificial intelligence models including multi-layer perceptron neural network, random forest, long short term memory (LSTM) algorithms. Water temperature, turbidity, pH, conductivity, flow rate, alkalinity and pre-chlorination dosage data are used as the input parameters to develop prediction models. As results, it is presented that the random forest algorithm shows the most moderate prediction result among four cases, which are long short term memory, multi-layer perceptron, multiple regression including random forest. Especially, it is result that the multiple regression model can not represent the residual chlorine with the input parameters which varies independently with seasonal change, numerical scale and dimension difference between quantity and quality. For this reason, random forest model is more appropriate for predict water qualities than other algorithms, which is classified into decision tree type algorithm. Also, it is expected that real time prediction by artificial intelligence models can play role of the stable operation of residual chlorine in water treatment plant including pre-chlorination process.

A Study on the Optimization of Sedimentation Efficiency through Controlling Stirring Speed and Baffle Angle (교반속도 및 Baffle 각도 조절에 따른 침전지 효율 최적화 연구)

  • Kwak, Sung-Keun;Kim, Choong-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.4
    • /
    • pp.69-75
    • /
    • 2020
  • This study was conducted to improve the solid-liquid separation efficiency of clarifiers. To do so, the study did a bio-flocculation experiment simply by controlling the stirring speed (rpm) and baffle angle of a clarifier on a lab scale, but without using a coagulant. For the purpose of the experiment, the feed wall of a clarifier was so improved that a baffle could be installed on the clarifier. Then, it was ensured to change its stirring speed (to 0.0rpm, 0.6rpm, and 1.2rpm), with the angle fixed at 10°. As a result, it was found that concentration efficiency increased by 2.0%, and effluent removal efficiency (SS concentration) by 7.8%, at a stirring speed of 0.6ppm. This indicates the bio-coagulation efficiency of sludge increased with changing stirring speeds. Then, the baffle angle of the sedimentation unit was changed to analyze how the changed baffle angle would affect the sedimentation of sludge. As a result, it was found that the compression of sludge interface was very effective at a baffle angle of 20°. It is hoped that these experimental findings will be useful in improving the sedimentation efficiency of circular clarifiers.

Evaluation of Hydraulic Behavior within Parallel arranged Upflow Sedimentation Basin Using CFD Simulation (I) - The influence of feed water inequity- (CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(I) - 침전지 내 유입유량 불균등 영향 조사 -)

  • Park, No-Suk;Kim, Seong-Su;Choi, Jong-Woong;Sung, Youl-Boong;Kang, Moon-Sun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.469-477
    • /
    • 2013
  • In order to investigate the influence of feed water inequity on the settling performance for parallel arranged upflow sedimentation basin in domestic G_WTP(Water Treatment Plant), CFD(Computational Fluid Dynamics) simulation were employed and ADV(Acoustic Doppler Velocimeter) measurements were carried out. From the results of both CFD simulations and ADV measurements, the differences among inlet flow rates to each inlet structure make turbulent energy dissipation uneven overall sedimentation basin. Especially local velocities in the near of both side wall were observed over the design overflow rate(74.4 mm/min). Also, it was confirmed that this inequity of inlet flow would exert an serious influence on the turbidity of settled water which is out from 8 troughs. Even though experimental velocities in full scale basin about 20% higher than the simulated, the results of ADV measurement were in good accordance with those of CFD simulations.