• Title/Summary/Keyword: 침전제 주입 속도

검색결과 13건 처리시간 0.025초

A Study on the Performance of Ni Catalysts in Biogas Steam Reforming: Impact of Supports and Precipitation Agent Injection Rates (바이오가스 수증기 개질 반응용 Ni 촉매 성능 연구: 지지체 및 침전제 주입 속도에 따른 영향)

  • Ji-Hyeon Gong;Min-Ju Kim;Kyung-Won Jeon;Won-Jun Jang
    • Clean Technology
    • /
    • 제29권4호
    • /
    • pp.327-332
    • /
    • 2023
  • This study investigated synthesis gas production via steam reforming of biogas. Ni-Al2O3 and Ni-CeO2 catalysts were synthesized using the co-precipitation method, with controlled precipitation agent injection rates. Catalytic performances were tested at various temperatures, with a gas composition ratio of CH4:CO2:H2O = 1:0.67:3 and a gas hourly space velocity (GHSV) of 647,000 mL h-1 gcat-1. The rate of precipitation agent injection influenced the characteristics of the catalysts depending on the type of support used. As the temperature increased, both the CO2 reforming of methane and the reverse water gas shift reactions occurred. The Ni-Al2O3 catalyst, synthesized with a single injection of the precipitation agent, exhibited the best catalytic activity under conditions with sufficient steam supply among the prepared catalysts, due to its high Ni dispersion.

Recovery and Characterization of Lactic Acid from Fermentation Broth Using Chemical Precipitation (화학침전을 이용한 발효액의 젖산 회수 및 유기물 특성분석)

  • Lee, Wontae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • 제26권1호
    • /
    • pp.47-53
    • /
    • 2018
  • Recovery of lactic acid from fermentation broth using chemical precipitation was investigated with various chemicals. Effects of chemical types, mixing speeds, settling duration, and solvent addition were evaluated to improve the recovery rates of lactic acid. Overall, recovery efficiencies increased as the dosage of chemicals increased. Recovery rate of lactic acid by CaO was higher than those of $Ca(OH)_2$ and $CaCO_3$. Recovery of lactic acid increased by 48% under the optimized reaction conditions which included a mixing speed at 180 rpm, a settling duration of 24 h, and addition of ethanol at 25%(v/v). Practical application needs to consider types and concentrations of other organic acids as well as lactic acid. Based upon the results of fluorescence excitation emission matrix (FEEM), size exclusion chromatography (SEC), characteristics of recovered lactic acid were same as that in the fermentation broth.

Synthesis of $TiO_2$Anchored on a Porous Clay Ceramic Support Using Dropping Precipitant Method (침전제 적하법을 이용한 $TiO_2$고정화 다공체 제조)

  • 신대용;한상목;김경남
    • Journal of the Korean Ceramic Society
    • /
    • 제38권12호
    • /
    • pp.1097-1103
    • /
    • 2001
  • TiO$_2$anchored on a porous clay ceramic support (PCS) for use in lightweight photocatalyst were synthesized by the dropping precipitant method. A PCS of macro and micro pore size of around several mm~${\mu}{\textrm}{m}$ in diameter were prepared by the rapid heat treatment at, 1,15$0^{\circ}C$ for 10 min from low grade of clay. The change in pH of reaction solution due to the different addition rate of NH$_4$HCO$_3$as a precipitant, the reaction temperature and the concentration of TiCl$_4$had a pronounced effect on the nature of precipitated TiO$_2$particles on the surface of a PCS and the crystal structure of precipitated TiO$_2$particles. At an addition rate of 0.8 ml/min of NH$_4$HCO$_3$and pH=6 of reaction solution, homogeneous precipitation of TiO$_2$particles on a PCS was achieved. TiO$_2$particles with anatase phase was precipitated on the surface of a PCS at the low concentration of TiCl$_4$, the high addition rate of NH$_4$HCO$_3$and the high reaction temperature.

  • PDF

A Study on Removal of Dissolved Organic Matter and Phosphorus in Eutrophic Lake by Coagulation Process Using Powdered Activated Carbon (분말활성탄 응집침전 공정을 이용한 부영양화 호소수의 용존 유기물 및 인의 제거 연구)

  • Cho, Kyung Chul;Lee, Min Hee;Park, Jung Hwan;Jung, Jongtai
    • Journal of Wetlands Research
    • /
    • 제14권4호
    • /
    • pp.629-635
    • /
    • 2012
  • This study was conducted to evaluate the removal behaviors of DOM(dissolved organic matter) and phosphorus in eutrophic lake water by coagulation process with PAC(powdered activated carbon). It was observed that the removal characteristic of soluble matter was different from that of dissolved one, and the removal of DOM was effected by both pH and coagulant dosage. It was founded that PAC could increase the removal efficiency by an adsorption of DOM in coagulation process. A formation of soluble and colloidal matters resulted in the degradation of phosphorus removal efficiency in a chemical precipitation process. The phosphorus removal efficiency could be enhanced by an absorption of colloidal matter and dissolved complex with PAC addition. In addition, the PAC addition caused the increase of floc density in coagulation process, that led to the rise of sedimentation rate, and resulted in a significant improvement of solid-liquid separation efficiency.

Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone (선회류를 이용한 응집침전모듈의 개발 및 실증 연구)

  • Moon, Jinyoung;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제15권5호
    • /
    • pp.3336-3344
    • /
    • 2014
  • The purpose of this study is small scale coagulation module is developed and demonstrated through a lab-scale test. Recent as a sewage treatment rate increases, have heightened the interest in the necessity on the nonpoint source and developing a small processing unit has been increased. Coagulation sedimentation module in this study is additional growth of floc through swirling in the outside zone, reduction of microstructure floc number and the internal settling zone through vertical/level flow complex sedimentation method after the coagulation process precipitation method as an effective high separation efficiency can be divided was also assessed. Coagulation sedimentation module can increase the load factor was 4.4 times compared to conventional clarifier base on the same volume and surface area through vertical/level flow. In this study, this process was selected formation and maintenance of swirling and uniform flow distribution in the internal settling zone as an important design factor, to derive its FLUENT was used to characteristics of the flow model. Through the simulation of swirling, influent velocity, dimensions of external basin, hopper depth of bottom cone was determined and through analysis of velocity distribution, flow distribution detailed specifications are derived like as diameter and number of effluent hole. Lab-scale($120{\ell}/hr$) test results, influent of 300~800 NTU to less than 10 NTU without polymer feeding was able to operate in the 20minutes retention time(surface loading rate $37.3m^3/m^2$-day), and through analysis FLUENT the possibility of using design parameters were derived.

Determination of Optimun Coagulant Dosage for Effective Water Treatment of Chinyang Lake -The Effect of Coagulant Dosing on Remoaval of Colloidal Pollutants- (진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -콜로이드성 오염물질 처리를 위한 응집제 주입효과-)

  • 이원규;조주식;이홍재;허종수
    • Journal of Environmental Science International
    • /
    • 제7권6호
    • /
    • pp.761-772
    • /
    • 1998
  • This study was performed to determine the optimum coagulant dosing amount for effective treatment of raw water. The removal rate of turbidity and the variations of water qualities according to various dosage of coagulants such as Alum, PAC and PACS were investigated. The optimum coagulant dosing amount to make the lowest turbidity of water were 35mg/ι t of Alum, 30mg/ι of PAC and 10mg/ι of PACS in case of 5 NTU of raw water turbidity, and 30mg/ι of Alum, 25mg/ι of PAC and 10mg/ι of PACS in case of 10 NTU of that, respectively. The removal rates of turbidity at 4 min. and 8 min. of settling time were 10 and 72% of Alum, 44 and 62% of PAC and 25 and 55% of PACS in case of 5 NTU, and 52 and 70% of Alum, 90 and 95% of PAC and 10 and 28% of PACS in case of 10 NTU, respectively. Judging from the settling capability of floc., the reaction time of floe. formation and removal efficiency of turbidity, PAC was evaluated as more effective coagulant than Alum and PACS. Also PAC was regarded as the most effective coagulant when the water supply was changed sharply and the fluctuation of the surface loading occured with wide and sharp in settling basin. pH and alkalinity of the water were decreased with increasing coagulants dosage. But pH and alkalinity were not decreased below 5.8 which is the standard for drinking water quality, and 10mg/ι which is the limit concentration of floc. breakage, respectively. Residual Al of the treated water was decreased with increasing coagulants dosage in case of 5 and 10NTU of raw water turbidity. $KMnO_4$ consumption of the water was decreased with increasing coagulants dosage. The reduction rate of $KMnO_4$ consumption at the optimum coagulants dosage were 39% of Alum. 18% of PAC and 11% of PACS in case of 5 NTU of raw water turbidity, and 42% of Alum, 27% of PAC and 36% of PACS in case of 10 NTU of that, respectively. Any relationship was not found between the removal rate of turbidity and KMnO$_4$ consumption. TOC of the water was a bit decreased with increasing coagulants dosage up to 30mg/ι but not changed above 30mg/ι of coagulants dosage. The degree of TOC reduction was increased in the order of Alum, PAC and PACS treatment. Zeta potential of the colloidal floe. at the optimum coagulants dosage was in the range of -20~-15mV in case of 5 NTU of raw water turbidity and 0~0.5mV in case of 10 NTU of that. respectively. Although the kinds and dosages of coagulants were different, zeta potential range were fixed under the conditions of the best coagulation efficiency.

  • PDF

Filtration characteristic of quantity of coagulant and variable pressure (응집제의 주입량 및 압력변화에 따른 여과특성)

  • Lee, Sung-ho;Lim, Taek-jun;Cho, Jun-hyung
    • Journal of Forest and Environmental Science
    • /
    • 제17권1호
    • /
    • pp.29-36
    • /
    • 2001
  • Compared to other industries, pulp and paper industry use a lot of water. As a result, a large amount of the waste water is discharged in the pulp and paper industry. This study was investigated to prevent the environmental pollution terribly faced with our society nowadays. In the waste water of pulp and paper, there are so many things in the waste water, like fiber, filler, and other organic solvent etc. so we must remove them from our environment. This study was investigated to experiment on test of impressed filtration with the kind and quantity of coagulant and the variance of pressure. In this study, we used feds, alums. $CaCl_2$, polymer as a coagulant and these pressure was 49, 98, 147, 196kpa. According to this study, we measured the speed of filtration and turbidity, measuring filtrated water. According to the values, we know the fact that as the consistency of coagulant and pressure were high, the filtration was good.

  • PDF

Evaluation of Biological Aerated Filter Position on Water Treatment Processes for Water Quality Improvement (상수원수 전처리 시 효율향상을 위한 생물여과 반응기 위치선정)

  • Choi, Hyung-Joo;Choi, Dong-Ho;Bae, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제28권6호
    • /
    • pp.677-686
    • /
    • 2006
  • This study was the effectiveness of two downflow BAF(Biological Aerated Filter) systems at conventional water treatment system. A BAF reactor placed in front of coagulation and sedimentation tanks(Mode A) and after coagulation and sedimentation tanks(Mode B) that were compared in terms of removal of suspended particles, organic matters, and ammonia nitrogen. The suspended particles removal efficiency was over 80% for both Mode A and B, although Mode A gave slightly better results. $BOD_5$ removal and nitrification efficiencies were more than 90% for both reactor. The organic matter and ammonia removals were also superior in the Mode A. The biofilm thickness and biomass increased as increment of EBCT and the upper part of reactor more about 30% than lower part. The specific oxygen uptake rate(SOUR) was higher the upper part of reactor and Mode A than the lower part of reactor and Mode B. A cost analysis showed that the Mode A system was more cost effectiveness. It could save the coagulant dose by about 67% and the chlorine demand by about 95%. The ideal place to put the BAF reactor was in front of the coagulation/sedimentation process.

Removal Improvement in Water Treatment Plant for Occurrence of Diatoms (Synedra sp.) in the Nakdong River (낙동강유역 상수원의 규조류 발생에 따른 정수장에서 제거율 향상 방안)

  • Kim, Min-Chai;Kim, Ji-Hoon;Seo, Gyu-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제36권1호
    • /
    • pp.29-34
    • /
    • 2014
  • This study was conducted to investigate removal characteristics for Synedra sp. and filter run time (FRT) according to the cell length in the Nakdong River. When used alone flocculent, the removal efficiency for Synedra tenera (around $100{\mu}m$) was constant with 90.9~94.4%, while Synedra acus (around $300{\mu}m$) had the lower removal efficiency as 60~70%. $PACS_2$ and PAC showed 5~6% higher removal for S. acus than others (HiB and LAS). When added coagulant aid, loess had no effect and also needed more amount of flocculent. Sodium Silicate increased the removal rate by max 10.6%. On the other hand, 2.5 mg/L of Polyamine showed 96.9% removal efficiency for S. acus increasing up to 25% more than $PACS_2$ alone. In the effect of water temperature, the removal for S. acus at $15^{\circ}C$ were 6% higher than at $4^{\circ}C$. There was no significant correlation between the removal efficiencys of turbidity and S. acus. The results of this study was similar to the actual water treatment process's removal characteristics for Synedra sp. depending on the cell length and temperature. In the actual process, the numbers of Synedra in settled water was established natural logarithm function with the filter run time (FRT), so we can predict FRT as Synedra numbers.

On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant (정수장 응집혼화공정에서의 응집플럭 연속 모니터링)

  • Ga, Gil-Hyun;Jang, Hyun-Sung;Kim, Young-Beom;Kwak, Jong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제31권4호
    • /
    • pp.263-271
    • /
    • 2009
  • This study evaluated the flocs forming characteristics in the mixing zone to increase the coagulation effect in the drinking water plant. As a measuring tool of formed flocs, on-line particle dispersion analyzer (iPDA) was used in Y drinking water plant. To evaluate the forming flocs, many parameters such as poly amine, coagulant dosing amount, raw water turbidity, and pH was applied in this study. During the periods of field test, poly aluminium chloride (PACl) as a coagulant was used. With the increase of the raw water turbidities, poly amine was also added as one of aids for increasing in coagulation efficiency. The turbidity and pH of raw water was ranged from 7 to 9 and from 25 to 140 NTU, respectively. The increasing of raw water turbidity brought the bigger floc sizes accordingly. From a regression analysis, $R^2$ value was 0.8040 as a function of T, raw water turbidity. Floc size index (FSI) was obtained from a correlation equation as follows; FSI = 0.9388logT - 0.3214 Also, polyamine gave the bigger flocs the moment it is added to the coagulated water in the rapid mixing zone. One of parameters influencing the floc sizes was the addition of powdered active carbon(PAC) in the mixing zone. In case of higher turbidity of raw water, $R^2$ value was 0.9050 in the parameters of [PACl] and [PAC]; FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ On-line floc monitor was beneficial to evaluate the flocs sizes depending on the many parameters consisting raw water properties, bring the profitable basic data to control the mixing zone more effectively.