• Title/Summary/Keyword: 친환경 건물

Search Result 128, Processing Time 0.022 seconds

Applied Technologies and Effects for the Carbon Zero Office Building (업무용 탄소제로건물의 적용기술 및 효과)

  • Lee, Jae-Bum;Hong, Sung-Chul;Beak, Name-Choon;Choi, Jin-Young;Hong, You-Deog;Lee, Suk-Jo;Lee, Dong-won
    • Journal of Climate Change Research
    • /
    • v.2 no.4
    • /
    • pp.283-295
    • /
    • 2011
  • Many actions against climate change have been taken to reduce greenhouse gases (GHGs) emissions at home and abroad. As of 2007, the GHGs emitted from buildings accounted for about 23 % of Korea's total GHGs emission, which is the second largest GHG reduction potential following industry. In this study, we introduced Carbon Zero Building (CZB), which was constructed by the National Institute of Environmental Research to cut down GHGs from buildings in Korea, and evaluated the main applied technologies, the amount of energy load and reduced energy, and economic values for CZB to provide data that could be a basis in the future construction of this kind of carbon-neutral buildings. A total of 66 technologies were applied for this building in order to achieve carbon zero emissions. Applied technologies include 30 energy consumption reduction technologies, 18 energy efficiency technologies, and 5 eco-friendly technologies. Out of total annual energy load ($123.8kWh/m^2$), about 40% of energy load ($49kWh/m^2$) was reduced by using passive technologies such as super insulation and use of high efficiency equipments and the other 60% ($74.8kWh/m^2$) was reduced by using active technologies such as solar voltaic, solar thermal, and geothermal energy. The construction cost of CZB was 1.4 times higher than ordinary buildings. However, if active technologies are excluded, the construction cost is similar to that of ordinary buildings. It was estimated that we could save annually about 102 million won directly from energy saving and about 2.2 million won indirectly from additional saving by the reduction in GHGs and atmospheric pollutants. In terms of carbon, we could reduce 100 ton of $CO_2$ emissions per year. In our Life Cycle Cost (LCC) analysis, the Break Even Point (BEP) for the additional construction cost was estimated to be around 20.6 years.

Energy Economic Analysis of Standard Rural House Model with PV System (PV 시스템이 적용된 농어촌 주택 표준모델의 에너지 경제성 분석)

  • Lee, Chan Kyu;Kim, Woo Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1540-1547
    • /
    • 2013
  • The energy economic analysis of the standard rural house model with PV system was performed based on annual energy demand calculation using the EnergyPlus to contribute in reducing building energy which occupies 25% of national energy consumption and in developing a low-energy & eco-friendly house model. Two types of PV system installation was considered to cover electricity demand for cooling, electric, and heating devices. For the selected house model, heating energy demand is 7 times higher than cooling energy demand. For the Case1, it is favorable to use electricity from PV system for cooling and electric devices and to sell surplus electricity. For the Case2, it is favorable to use electricity from PV system for cooling, electricity and heating devices and to sell surplus electricity. Considering the installation cost of PV system and heat pump air conditioning system, the break-even point of Case1 and Case2 are about 13 and 11 years respectively. Although the installation cost of Case2 is more expensive, Case2 provides three times more profit than Case1 after the break-even point. Because the expected average life time of the selected PV system is 25 years, Case2 is more favorable option for the given standard rural house model.

Effect of Bi and Zr addition on yellow colour properties of environment-friendly ceria-based pigments (비스무스와 지르코늄 첨가를 통한 세리아계 친환경 노란색 안료 특성에 관한 연구)

  • Kim, Tae-Ho;Hwang, Hae-Jin;Kim, Jin-Ho;Hwang, Kwang-Taek;Han, Kyu-Sung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.4
    • /
    • pp.153-159
    • /
    • 2015
  • Inorganic pigments have been received a great attention for various applications including paint, glazed ceramic ink, art tile, and building exterior due to their excellent thermal and chemical stability. Traditionally, the compositions of $PbCrO_4$, CdS and CdSe have been widely used as a yellow inorganic pigment. However, the use of these compositions has been restricted in recent years, because they contain harmful elements such as Cd, Cr, Pb and Se. In this study, new environment-friendly ceria-based pigment was synthesized using solid state reaction. Crystal structure and morphology of the obtained $Ce_{1-x}Zr_xBi_yO_{2-y/2}$ yellow pigment were analyzed using XRD and SEM, respectively. Substitutional effect of Zr and Bi on the pigment color was analyzed using UV-vis. spectrophotometer and CIE $L^*a^*b^*$ analysis. The crystal structure of the obtained pigments was dependent on the calcination temperature. The color characteristics and absorption band of the pigments were dependent on the calcination temperature and Zr, Bi contents. As a result, all the obtained yellow pigments showed the effective absorption ranged from ultraviolet to visible light, and $Ce_{0.44}Zr_{0.36}Bi_{0.20}O_{0.19}$ (x = 0.36, y = 0.20) pigment showed the most brilliant yellow color.

Daylighting Performance of Office Space Applied with Electrochromic Façade System (전기변색 외피시스템 적용 업무공간의 채광 성능 분석)

  • Kim, Jae-Hyang;Han, Seung-Hoon
    • Land and Housing Review
    • /
    • v.13 no.1
    • /
    • pp.131-140
    • /
    • 2022
  • A smart window is a new building material that can realize energy savings in a building. Smart windows can freely adjust Visible Light Transmittance (VLT) and solar gain coefficient (g-value) according to the situation. Smart windows include such technologies as Electrochromic (EC), Suspended Particle Device (SPD), and Polymer Dispersed Liquid Crystal (PDLC). Recent research on building energy savings through the VLT and g-value control functions of smart windows is being actively conducted and meaningful results are being drawn. However, since most of the research is focused on energy savings, research on the indoor environment is somewhat lacking. A building is a space where people live and the comfort of life should be prioritized before energy savings. Therefore, in this study, analysis on the daylight performance of an office space was carried out. Through green building standards such as LEED, BREEAM, CASBEE, and G-SEED, the daylight performance was reviewed according to VLT value changes of the smart window. In addition, a study was conducted on the VLT range of the electrochromic façade that can maintain a comfortable indoor environment. The smart window used electrochromic control with a wide range of VLT. The study showed that the minimum VLT of a smart window that can satisfy G-SEED is 25% or more. In addition, it was found that the VLT change of the electrochromic smart window did not significantly affect the uniformity of the room. When the LEED standard was applied, the minimum VLT value of the electrochromic smart window that must be maintained according to each orientation of the building was derived.

A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency (비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구)

  • Jang, Hyun-Sook;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.3-12
    • /
    • 2012
  • The slowdown of private building industry resulted in growth of remodeling market as a way to improve energy performance. Remodeling is considered more cost-effective and eco-friendly approach for energy efficient building than new construction. Since 2008, Seoul has promoted Building Retrofit Project (BRP) preponderantly to attract energy-saving renovation by supporting building owners to switch building system into energy-saving system when they remodel their old buildings. According to 2012 press release, 254 Private sectors participated in this green building project and annually reduced 41000ton of greenhouse gas emission, 14000TOE, which also result in 7.5 billion won energy cost savings per year. The paper focuses on the building envelope remodeling as a way to improve energy efficiency. Different components of the building envelope such as wall insulation, window, and shading, were applied to the baseline model and the comparison was analyzed to come up with the ideal solution. This study only assesses the building envelope as to suggest the way to redesign the better energy performing building. Offering solution focusing on the architectural feature is essential because it will provide basic information and standard when remodeling a building for energy efficiency, especially, for the nonresidential buildings used as rental offices.

A Study on the Necessity of Vertical Garden in Public Places for Urban Environment Improvement (도시환경 개선을 위한 공공장소의 수직정원 필요성에 관한 연구)

  • Kim, Chul-soo
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.6
    • /
    • pp.75-81
    • /
    • 2021
  • (Research background and purpose) Urban development has also had a significant impact on the eco-friendly industry. In the public environment, citizens are stressed in many areas, which has really made them need a natural ecological environment. Therefore, it is necessary to improve the environment into an eco-friendly urban public facility that breathes the urban environment space inside the building with plants. To this end, we want to show that the urban environment can be improved through vertical gardens. And through this, we want to contribute to the popularization of vertical gardens. (Research Methodology) we will analyze the problems of the current public environment in the city and look at the supplementation around vertical gardens. (Result) A study of the public environment in the city found problems such as gloomy environment, poor use of space, dim color, and poor air quality, and wanted to create a vertical garden to provide a pleasant shelter. These vertical gardens have influenced urban public places with improved aesthetics, increased social value, insulation and soundproofing effects of buildings, reduced urban heat island effects, and increased urban green appearance. (Conclusion)This study uses vertical gardens in public spaces to design public spaces that are more comfortable and share mental and physical health together.

Patent Analysis on Fuel Cell By-Product Utilization Technology for Operating Expenditure Reduction of Hydrogen Residential Buildings (수소에너지 주거건물의 운영비용 감축을 위한 연료전지 발전 부산물 활용기술에 관한 특허분석)

  • Ji, SangHoon;Kim, WeonJae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.488-493
    • /
    • 2020
  • The demand for hydrogen, which is considered an environmentally friendly energy source, is increasing, and at the same time, the fuel cell market is increasing continuously. This study aimed to establish a strategy for securing intellectual property rights on fuel cell by-product utilization technology for operating expenditure reduction of hydrogen-powered residential buildings. In this patent analysis, this study investigated Korean, American, Japanese, and European patents filed/published/registered by October 2019 and established a technical classification system and classification criteria through expert discussion. To reduce the operating expenditure of hydrogen-powered residential buildings, intellectual property rights will be improved using systems and methodologies involving cathode-side purified air, product water, and oxygen-depleted air captured with the dead-end mode operation of polymer electrolyte fuel cells.

A Study on the Calculation Method for Flexural Strength of One-way Hollow Slabs (일방향 중공슬래브의 휨강도 산정방법에 관한 연구)

  • Kim, Hyun-Su;Lim, Jun-Ho;Kang, Joo-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.6
    • /
    • pp.541-548
    • /
    • 2012
  • The hollow slab has advantages that its self-weight does not greatly increase notwithstanding the increase of its thickness and its flexural performance does not significantly degrade in comparison with general reinforced concrete slab. However, the utilization of the hollow slab is currently being underestimated in spite of structural system that enables economic design of building and construction of eco-friendly structure. the significant reasons for this situation is that the method of structural analysis and design for hollow slab is not generalized. In this study, to consider practical compressive zone of hollow slab, the equation for its flexural strength is proposed by the volume of compressive stress block according to neutral axis location in hollow section assumed. Existing estimation method of flexural strength of hollow slab considering only compressive zone above hollow part is evaluated as the most conservative method and the method estimating flexural strength by two alternative cross-section of hollow slab is evaluated as more practical method.

A Study on the Proposal of Building Technologies for Reducing $CO_2$ Emission of Buildings(Focused on the Multi-Family Residential Buildings) (건물의 $CO_2$ 배출 저감 건축기술요소 제안에 관한 연구(공동주택을 중심으로))

  • Lee, Jong-Sik;Kang, Hae-Jin;Park, Jin-Chul;Rhee, Eon-Ku
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.91-96
    • /
    • 2009
  • First, the base model of multi-family residential buildings are selected, and then the $CO_2$ reduction building technologies that are applicable for multi-family residential buildings are induced by analyzing the examples and then an optimal plan for when the $CO_2$ reduction building technologies can be integrated and applied to the base model was formulated. In the results of converting the energy consumption and reduction amount from the building technologies into $CO_2$ emissions to analyze the distribution ratio compared to the entire $CO_2$ emissions; the heat recovery ventilator is 0.5%, the photovoltaic system is $1.9%{\sim}5.9%$, the solar hot water heating system is $6.3%{\sim}13.1%$ and the ge thermal heat-pump system is 39.0% when both heating and hot water heating are applied. An optimally integrated application method for the building technologies is in charge of heating and hot water heating through the geothermal source heat pump system and in charge of the electricity load through the photovoltaic system(45.2%).

  • PDF

Assessment of Evaluation by Hybrid Waterproof-Roof Barrier Layer for Green System on Artificial Ground (인공지반 녹화시스템 활용을 위한 일체형 방수·방근 시트의 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • The demands about eco friendly space are increased as buildings are denser in downtown, and green system on the roof and the artificial ground are widely being applied. The construction of green system applies a waterproof layer, a root barrier and a protection concrete layer. Assembly of these many layers leads to a long construction term, and cause many defects. This study is to evaluate one layer-hybrid sheet which gets waterproof and root barrier performance simultaneously, which is developed to use in the new green system. As results, the performances of physical properties, durability, waterproof and root barrier not only exceeded quality standards but also showed excellent durability. In addition, mock-up test would be proceed to certify long term performance.