• Title/Summary/Keyword: 치아 언더컷

Search Result 6, Processing Time 0.025 seconds

Modified resin-bonded fixed partial dentures utilizing tooth undercuts: a clinical case study (서로 다른 삽입로를 이용한 최소 삭제 접착성 고정성 보철물의 임상 연구)

  • Doh, Re-Mee;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.106-113
    • /
    • 2011
  • The object of this clinical study was to evaluate the short-term outcome of modified resin-bonded fixed partial dentures which utilizes the original tooth undercuts and different path of insertion of components. Materials and methods: 71 units of modified RBFPDs that were used in 21 patients at the Department of Prosthodontics, College of Dentistry, Yonsei University were evaluated. The follow-up period was up to 25 months, the mean being 7 months. Survival rate, mobility, percussion, probing depth, bleeding on probing, plaque index was recorded and radiographs were taken to monitor alveolar bone loss. Results & Conclusion: Within the limits of this short term retrospective study, it was concluded that: 1. No mechanical failure such as debonding or fracture of the framework was found during the follow-up period. 2. The periodontal apparatus was stable and no clinical change was observed after prosthetic treatment. 3. No significant marginal bone loss was found in the radiographic evaluation.

Effect of interproximal undercut on the dimensional accuracy of impression (치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향)

  • Lee, Ju-Ri;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Purpose: This study evaluated the effect of loss of interproximal papilla, creating an undercut, on the accuracy of impression materials. Materials and methods: Two addition type silicone impression materials ($Extrude^{(R)}$ Speed Wash, $Imprint^{TM}$ II Quick Step Light Body) and one alginate impression material (Cavex Impressional) were used to make impressions of a maxillary master model simulating clinical conditions with or without interproximal papilla. Stone was poured in the impressions and working casts were fabricated. A total of 6 groups with 6 working casts in each group were scanned using 3-dimensional optical scanner. The accuracy of the impressions was assessed by measuring the dimensional changes (${\Delta}I$ (%)) of 6 distances on working casts compared to a master model with a 3-dimensional digitizing and inspection software. The data were analyzed by two-way ANOVA (P<.05). Results: Three of 6 distances showed statistically significant differences among the impression materials. Only 1 of 6 distances in alginate impression showed a statistically significant difference between casts with and without interproximal papilla (P=.047). Conclusion: The presence of undercut due to loss of interproximal papilla did not significantly influence the dimensional accuracy of addition type silicone and alginate impression materials.

INFLUENCE OF INDIVIDUAL TOOTH TRAY ON THE TEETH WITH UNDERCUT IN IMPRESSION TAKING (언더컷이 있는 치아에서 개별 치아 트레이가 인상채득에 미치는 영향)

  • Seo Kowang-Won;Shin Sang-Wan;Lee Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Problem : The several studies were reported to the effects of individual tooth tray with the parallel tooth, but not reported to the effect of individual tooth tray with severe undercut in impression making. Purpose : The purpose of this study is to examine the effect of individual tooth tray; 1) the accuracy of impression in terms of distance. 2) reproducibility of pocket. Material and methods : In this study, a metal model with 3 teeth including tooth prepared 30-degree undercut and gingival crevice of the depth 5mm, width 0.4mm was cast. Impressions of the metal model were taken in 5 times used 4 kinds of impression materials with individual tooth tray and another impression taking were made with conventional method without individual tooth, used same materials, procedure. The stone models were made. Distances between abutments were measured with a Micromeasurescoup-mm. Result : The following results were obtained ; 1. In the comparisonof inter-abutment distance between parallel tooth without individual tooth tray, 4elastomeric materials have not significant difference to the metal model(p>0.05). 2. In the comparisonof inter-abutment distance with undercut tooth without individual tooth tray, 4elastomeric materials have a significant difference to the metal model(p<0.05), especially polyether's dimensional change is large. 3. If individual tooth tray was used to take impression in abutment teeth with severe undercut, more stable results was achieved easily than conventional method. (p>0.05). 4. It is not true that the pressure of impression material with individual tooth tray increased to gingival sulcus. Conclusion : By the results, I knew the fact that individual tooth tray was useful impression method on the teeth with severe undercut for the dimensional stability. Also, I could not confirm the fact that individual tooth tray would increase the penetrating pressure into cervice.

Fabrication of palatal lift prosthesis using thermoplastic resin for a patient with velopharyngeal insufficiency (구개인두부전증 환자에서 열가소성레진을 이용해 연구개거상장치를 제작한 증례)

  • Jung, Hyun Jung;Kim, Jee Hwan;Lee, Sang-Hwy;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.286-290
    • /
    • 2016
  • Recently, flexible removable prosthesis with thermoplastic resin clasp has increasingly become popular. In comparison with conventionally used acrylic resin, thermoplastic resin has lower flexural strength and elastic modulus. Thus, flexible removable prosthesis has low risk of fracture, so denture base can be made thin and light, increasing patient comfort. Also, it can passively sit at tooth undercut during rest, so abutment teeth need minimum or no preparation. In this case report, a 44 year old female patient with mild velopharyngeal insufficiency was treated with a palatal lift prosthesis made of polyester thermoplastic resin. Since the patient had no missing tooth and desired conservative treatment, the flexible removable prosthesis provided relatively satisfactory results.

Restoration of partial removable dental prosthesis after fabricating of surveyed crowns utilizing electronic surveying: a case report (전자 서베잉을 이용한 서베이드 크라운 제작 후 국소의치 수복: 증례보고)

  • Min, Byungkwee;Jun, Daejeon;Yang, Hongso;Park, Sangwon;Lim, Hyunpil;Yun, Kwidug;Park, Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.135-142
    • /
    • 2017
  • Adoption of CAD/CAM milling in dentistry has allowed production of more analytic and precise prosthesis. Such precision enables definite path of insertion and undercut to be provided in removable partial denture especially when designing a surveyed crown on an abutment tooth. This case is about the production of surveyed crown with proper path of insertion utilizing CAD/CAM electronic surveying method on a patient with edentulous maxilla. Resulting removable partial denture fit well and showed acceptable stability and retention with no clinical problem.

Full Mouth Rehabilitation with a Overlay Denture (피개의치를 이용한 지적장애인의 완전구강회복)

  • Ko, Kyung-Ho;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.385-395
    • /
    • 2012
  • This clinical report presents the case using overlay dentures to treat a patient with cleft lip and palate and malocclusion. This patient requires vigorous treatment such as orthodontic treatment and combined orthodontic/oral surgery procedures. Overlay denture can be used as an alternative treatment option. Intraoral and radiographic examinations were done. The vertical dimension of occlusion was evaluated for proper prosthetic procedures and the surveying in the diagnostic cast was done. Considering the tissue and teeth undercut, the alterations of teeth shape were done. Final preparation and impression was performed. After the evaluation of vertical dimension and occlusion with wax-denture, the dentures were polymerized. Clinical remounting and occlusal adjustment were done on the articulator. Overlay dentures were delivered and the patient was recalled for relining. The overlay dentures satisfied patient's esthetic and functional requirements and provided a stable occlusion. Overlay dentures in this case were a reversible and relatively inexpensive treatment for this patient, however the potential possibilities of caries and periodontal disease as a result of poor oral hygiene should be prevented with periodic recall.