• Title/Summary/Keyword: 치아 구조

Search Result 226, Processing Time 0.026 seconds

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.

A comparative study on head posture and craniofacial morphology between koreans and scandinavian caucasians (한국인과 스칸디나비아계 백인의 두부자세와 두개안면구조의 형태에 관한 비교연구)

  • Oh, Yong-Duck;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.707-720
    • /
    • 1999
  • The purpose of this study was to evaluate racial differences In head posture and the influence of head posture to the craniofacial morphology. The sample group of this study was made up of 51 Korean males and 120 Scandinavian Caucasian males. From the comparison of the cranio-cervical angle and the variables of craniofacial morphology between them, the following results were obtained. 1. The cranio-cervical angle (NSL/OPT) was on average 9.28 degrees larger In Koreans. 2. The length of the anterior cranial base (N-S) was on average 4.66mm shorter in Koreans. 3. The length of the maxillary base (sp-pm and ss-pm) were on average 2.75mm and 4.65mm shorter in Koreans respectively, the anterior maxillary height (n-sp) was on average 2.60mm longer, the posterior dimension (s-pm) was found to be 2.06mm longer in Koreans, and the maxillary inclination (NSL/NL) was identical in both samples. 4. The mandibular body length (pg-tgo) and ramus height (ar-tgo) were identical in the two groups, but the genial angle (ML/RL) was 3.22 degrees smaller and the mandibular plane inclination (NSL/ML) was 2.44 degrees larger in Koreans 5. The maxillary prognathism (s-n-sp and s-n-ss) and the mandibular prognathism (s-n-sm) were identical in both samples. 6. The sagittal jaw relationship (ss-n-pg) was 1.44 degrees larger in the Korean sample, but the vortical jaw relationship (NL/ML) was not significantly different. 7. The anterior facial height (n-gn) was 5.57mm longer in the Korean sample. 8. The mandibular alveolar prognathism (CL/ML) was 5.71 degrees greater and the interincisal angle (ILs/ILi) was 3.08 degrees more acute in Koreans. Taken together these results, craniofacial morphology can be influenced by the head posture defined by cranio-cervical angulation.

  • PDF

Effects of chromium chloride addition on coloration and mechanical properties of 3Y-TZP (크롬염화물 첨가에 따른 지르코니아 색상 및 물리적 성질 변화에 관한 연구)

  • Oh, Gye-Jeong;Seo, Yoon-Jeong;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Lee, Kyung-Ku;Lim, Tae-Kwan;Lee, Doh-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.120-127
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of chromium chloride addition on coloration, mechanical property and microstructure of 3Y-TZP. Materials and methods: Chromium chloride was weighed as 0.06, 0.12, and 0.25 wt% and each measured amount was dissolved in alcohol. $ZrO_2$ powder was mixed with each of the individual slurry to prepare chromium doped zirconia specimen. The color, physical properties and microstructure were observed after the zirconia specimen were sintered at $1450^{\circ}C$. In order to evaluate the color, spectrophotometer was used to analyze the value of $L^*$, $C^*$, $a^*$ and $b^*$, after placing the specimen on a white plate, and measured according to the International Commission on Illumination (CIE) standard, Illuminant D65 and SCE system. The density was measured in the Archimedes method, while microstructures were evaluated by using the scanning electron microscopy (SEM) and XRD. Fracture toughness was calculated Vickers indentation method and indentation size was measured by using the optical microscope. The data were analyzed with 1-way ANOVA test (${\alpha}$ = 0.05). The Tukey multiple comparison test was used for post hocanalysis. Results: 1. Chromium chloride rendered zirconia a brownish color. While chromium chloride content was increased, the color of zirconia was changed from brownish to brownish-red. 2. Chromium chloride content was increased; density of the specimen was decreased. 3. More chromium chloride in the ratio showed increase size of grains. 4. But the addition of chromium chloride did not affect the crystal phase of zirconia, and all specimens showed tetragonal phase. 5. The chromium chloride in zirconia did not showed statistically significant difference in fracture toughness, but addition of 0.25 wt% showed a statistically significant difference (P<.05). Conclusion: Based on the above results, this study suggests that chromium chlorides can make colored zirconia while adding in a liquid form. The new colored zirconia showed a slight difference in color to that of the natural tooth, nevertheless this material can be used as an all ceramic core material.

Ultrastructural Changes on the Cuticular Surface, Excretory and Digestive Organs of Anisakis simplex Larvae Chronologically Recovered from Experimental Cats (실험감염 고양이로부터 경시적으로 회수한 고래회충 유충의 표피, 배설기 및 소화기의 미세구조 변화)

  • Sohn, Woon-Mok
    • Applied Microscopy
    • /
    • v.29 no.2
    • /
    • pp.211-221
    • /
    • 1999
  • The ultrastructural changes of cuticular surface, excretory and digestive organs of Anisakis simplex larvae chronologically recovered from experimental cats were observed with a SEM and TEM. The larva recovered from an experimental cat at 3 days post-infection (PI) retained the cuticular surface with regular transverse striations and a longitudinal groove on the lateral side of body. This finding suggests that the molting of the 3rd stage larva of A. simplex to 4th one occurred from the 3rd day after infection in cats. The excretory organ (renette cell) consisted of a large cell with numerous ductules ramified from the main duct, mitochondria and secretory granules in cytoplasm. Secretory granules in the renette cell of larvae recovered at 24 hours PI were round whereas those of control and larvae recovered at 6 hours PI were amorphous. Muscular esophagus and ventriculus also retained many secretory granules in the cytoplasm. The secretory granules in these organs of larvae recovered at $6\sim24$ hours PI were electron-dense and widely distributed whereas those of control worm were packed in a pocket and retained various electron densities. In the cytoplasm of intestinal epithelial cells, numerous fine glycogen particles and mitochondria were distributed. The chronological changes of secretory granules in renette cell, muscular esophagus and ventriculus seem to be related with the worm penetration into host tissue.

  • PDF

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Implant restoration considering maintenance for a patient with excessive crown height space (과도한 치관높이 공간을 가진 환자에서 유지관리를 고려한 임플란트 수복증례)

  • Ma, Juri;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • Complications increases when crown height space is excessive and one should be careful of choosing type of fixed prosthesis in case crown height space is over 12 mm. In this condition, tooth seems to be longer, therefore, it is needed to use gingival shade in aesthetically important area for fixed prosthesis. In this case, fixed prosthesis which has inappropriate maintenance and hygiene could hold food, plaque, calculus, thus increase incidence of inflammation and infection. Moreover, it could lead to chronic inflammation and infection and in that case surgical improvement could be necessary. In present case report, gingival inflammation and swelling developed around prosthesis after having made it considering articulation and aesthetic view in patient who had excessive crown height space. Finding out that design of prosthesis is a factor to make it hard to maintain oral hygiene, a temporary prosthesis which has enough interproximal space and proper emergence profile was fabricated. After two months of observation, significant abnormal symptoms are not found and oral reconstruction is performed using fixed prosthesis with zircornia infrastructure and porcelain build-up based on convenient self hygiene design. Through serial treatment, inappropriate soft tissue response is not observed and satisfactory result in functional aspect comes out.

The study on success rate of single implant replacing the mandibular first and second molars (하악 제1, 2대구치 단일 임플란트의 생존율에 관한 연구)

  • Jung, Taek-Gyun;Paeng, Joon-Young;Cho, Jin-Hyun;Lee, Sang-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.252-260
    • /
    • 2013
  • Purpose: After the introduction of concept of osteointegration, dental implantology have been successful procedure in the dental field. Recently, it has shown successful results when used to restore single tooth missing. Considering the difference in bone quality of the mandible and maxilla, and the increased occlusal force in the posterior region, the success rates in each region may be different. In this study, success rates of single implants placed in the mandibular first and second molar areas were analyzed. Materials and methods: The subjects were patients (284 patients, 308 implants) who had been operated with single implant installation from 2002 to 2009 in seven dental clinics in Daegu city. One hundred sixty eight implants were placed in the mandibular 1st molar and 140 implants were placed in the mandibular 2nd molar. They were analyzed according to implant site, age, sex, length and diameter. Results: The survival rates of single implant of this study were 97.6% in the mandibular 1st molar and 92.9% in the mandibular 2nd molar. In the mandibular 1st molar, 4 implants were failed. In the mandibular, 2nd molar, 10 implants were failed. Conclusion: The restoration of the mandibular 1st molar using single implant was found to be clinically acceptable treatment and showed higher survival rate than mandibular 2nd molar single implant. Single implant in mandibular 2nd molar needs careful consideration of poor bone quality, risk of overloading and anatomical structure of the mandible.

Implant-supported maxillary full-arch fixed prosthesis opposing mandibular natural dentition: A clinical report (하악 자연치열에 대합되는 상악 임플란트 전악 수복 증례)

  • Kim, In-Ju;Park, Jong-Hee;Park, Ju-Mi;Song, Kwang-Yeob;Ahn, Seung-Geun;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.51-57
    • /
    • 2015
  • When an implant-supported maxillary full-arch fixed prosthesis is planned for patients with the horizontal and vertical bone resorption induced by periodontal disease, it is necessary to consider the masticatory function, esthetics and phonetics when placing implants. For this reason, thorough clinical and radiological diagnosis is necessary. Extensive bone and soft tissue grafting may be required as well. Since there is no clear guideline for proper number of implants, segment or splinting of substructure and method of retaining prosthesis, these should be considered during diagnostic process. This clinical report describes a patient who has experienced several tooth extractions and periodontal treatment due to severe periodontitis on maxilla and mandible. With bone and soft tissue graft before dental implant placement, the patient have satisfactory result in esthetic and functional aspect with the implant-supported maxillary full-arch fixed prosthesis opposing mandibular natural dentition.

The implant overdenture on the edentulous mandible using CAD/CAM system: A case report (CAD/CAM system을 이용한 하악 임플란트 피개의치 수복증례)

  • Lee, Si-Eun;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.66-73
    • /
    • 2015
  • Alveolar bone loss and deformation can be a risk factor in removable prosthetic restoration treatment for partially or fully edentulous patients. The use of implants to solve this problem could improve the support, retention and stability of removable restoration. Attachments used in implant overdenture are versatile. The attachment should be selected according to the patients' conditions. Milled bar has been chosen when readymade bar could not be used because of the narrow distance between implants or firm stability and support of supra-structure were needed. Milled bar design is able to provide cross arch stabilization and comfortability to patients. However, it needs skilled laboratory procedures. Recently, the fabrication of milled bar has become simple and its suitability has been improved through the development of CAD/CAM system. In a 67-year-old female Alzheimer's disease patient with 8 implant fixtures on the fully edentulous site of mandible, implant overdenture with using milled bar and magnet attachment was planned. As rapid treatment was required, CAD/CAM system was used to make a simple laboratory procedure instead of a traditional fabrication process. With this system, implant overdenture with milled bar can be fabricated esthetically and functionally.

Development of Organic Paste Porcelain for Fixed Prostheses (유기조성물을 이용한 페이스트형 일반도재 시스템)

  • Han, Jung-Suk;Lee, Myung-Hyun;Kim, Dae-Hyun;Chung, Hun-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.109-120
    • /
    • 2004
  • INTRODUCTION: The build-up method has been used for application of porcelain powder on the metal framework to make final tooth shape conventionally. This method takes time and need skill to mimic final shade and shape of porcelain fused to metal crown. The purpose of this study was to develop standard shape and shade laminating porcelain forms to reduce build-up time. METHODS: To make tooth form porcelain paste, several liquid organic compounds were added to conventional feldspathic porcelain. The amount of additives and rheologic property were tested to find out best composition. Comparison of mixing methods to reduced porosity, proper heating schedule, and measurement of shrinkage amount and residual organic materials were performed to set-up standard procedures. Finally, biaxial flexural strength and color of preformed laminated paste porcelain were compared with those of porcelain which fabricated by the conventional build-up method. RESULTS: There was no significant difference in physical properties and color stability between two fabrication methods after various testing methods. Conclusion: This new build-up method can be applied to fabricate the PFM crown and bridge without any loss of strength and optical properties.