• Title/Summary/Keyword: 치아모형

Search Result 219, Processing Time 0.03 seconds

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

A STUDY ON THE RELATIONS OF VARIOUS PARTS OF THE PALATE FOR PRIMARY AND PERMANENT DENTITION (유치열과 영구치열의 구개 각부의 관계에 관한 연구)

  • Lee, Yong-Hoon;Yang, Yeon-Mi;Lee, Yong-Hee;Kim, Sang-Hoon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.569-578
    • /
    • 2004
  • The purpose of this study was to clarify the palatal arch length, width and height in the primary and permanent dentition. Samples were consisted of normal occlusions both in the primary dentition(50 males and 50 females) and in the permanent dentition(50 males and 50 females). With their upper plaster casts were used and through 3-dimensional laser scanning(3D Scanner, DS4060, LDI, U.S.A.), cloud data, polygonization, section curve and loft surface, fit and horizontal plane were based to measure the palatal arch length, width and height(Surfacer 10.0, Imageware, U.S.A.). T-tests were applied for the statistical analyze of the data. The results were as follows : 1. In the measurement values, the values of the male were higher than those of the female except primary anterior palatal height. There were not only statistically significant differences in anterior palatal width(p<0.05) and posterior palatal width(p<0.01) in primary dentition but palatal width(p<0.05), anterior palatal length(p<0.01), middle and posterior palatal length(p<0.05) in permanent dentition between male and female. 2. In the indices of palate, there were statistically significant differences in height-length index(p<0.05) and width-length index(p<0.01) between male and female in primary dentition. In permanent dentition, there was statistically difference between male and female. 3. In the measurement values, posterior palatal width was increased most greatly. Posterior palatal height, anterior palatal width and anterior palatal length were followed by descending order. On the other hand, anterior palatal height and posterior palatal length were decreased. 4. In the indices of palate, the height-length index, the width-length index and posterior height-width index were increased, but the others were decreased.

  • PDF

An evaluation of the adequacy of pont's index (Pont 지수의 임상적 적합성에 대한 평가)

  • Kim, Seong-Hun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.115-126
    • /
    • 2000
  • Dental arch expansion is one of the method used to solve the dental crowding problem by non-extraction. Many formulae using tooth size have been suggested to predict ideal inter-premolar and inter-molar width. The purpose of this study was to evaluate the adequacy of some upper dental arch width prediction methods, namely Pont's method, Schmuth's method and Cha's method. The sample consisted of the casts of 119 Korean young adults who had no muscular abnormality, no skeletal discrepancy, and Angle's Class I molar relationships. Measurements were obtained directly from plaster casts; they Included mesiodistal crown diameters of the four maxillary incisors, as well as maxillary inter-first-premolar and inter-first-molar arch widths as specified by Pont. The correlation coefficients between the sum of incisors(SI) and upper dental arch width were calculated. The differences between predicted width and actual width were classified as overestimated, properestimated, and underestimated. The data obtained from each group were analyzed for statistical differences. The results were as follows : 1. Upper dental arch width indices were calculated from SI in normal occlusion (81.96 : premolar index, 62.55 : molar index). 2. Low correlations between SI and arch width were noted in normal occlusion (0.50 in the inter-premolar width, 0.39 in the inter-molar width). 3. Pont's formula and Schmuth's formula tended to overestimate the inter-premolar width. A more even distribution of estimates was noted in Cha's fomula. 4. Cases within $\pm$1 mm range of observed inter-premolar width were $45\%$ in the Cha's formula, $40\%$ in the Pont's formula, and $39\%$ in the Schmuth's formula. 5. All formulae had a tendency to underestimate the inter-molar width, but Cha's formula had better predictability than others. 6. Cases within $\pm$1 mm range of observed inter-molar width were $40\%$ in the Cha's formula, $29\%$ in the Pont's formula, and $13\%$ of Schmuth's formula. The data presented in this study does not support the clinical usefulness of ideal arch width prediction methods using the mesiodistal width of maxillary incisors.

  • PDF

An Epidemiologic study on the Orthodontic Patients Who Visited Department of Orthodontics, Chosun University Dental Hospital Last 10 Years(1990${\sim}$1999) (최근 10년간 조선대학교 부속치과병원 교정과에 내원한 부정교합 환자에 관한 역학적 연구(1990${\sim}$1999))

  • Yoon, Young-Jooh;Kim, Kwang-Won;Hwang, Mee-Sun
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.283-300
    • /
    • 2001
  • With socioeconomic development and change of esthetic recognition, the demand for orthodontic treatment and number of orthodontic patients has been increasing so rapidly. And frequency of malocclusion was changed. So this study was done in an attempt to provide an epidemiologic study so that we can accomodate their orthodontic needs adequately and to obtain the reliable quantitative information regarding the characteristics of orthodontic patients. Distribution and trends were examined in 3,070 malocclusion patients who had been examined and diagnosed at Department of Orthodontics, Dental Hospital, Chosun University over 10 year-period from 1990 to 1999. The results were as follows : 1. The number of patients per year was increasing trend and higher visiting rate in female(56.5%) than in male(43.5%). 2. Age distribution had shown 7${\sim}$ 12 year-old group being the largest(37.9%) and each percentage of 13${\sim}$18, 19${\sim}$24, above-19, 0${\sim}$6 year${\sim}$old group was 32.0%, 19.6%, 7.1%, 3.4%. 3. Hellman dental age IVa which is completion of the permanent dentition showed the highest percentage in male and female. 4. Geographic distribution showed a majority of patients in Kwang Ju(71.0%). Group within the distance 10km from Chosun Dental Hospital was 56.3% and group within 20km was 14.7%. 5. Anterior cross bite showed the highest percentage in chief complaints and percentage of Mn. prognathism and protrusion of Mx. teeth was 12.6%, 12.2%. 6. Distribution in the types of malocclusion according to the Angle's classification had shown; 38.9% for Class I, 20.7% for Class II division 1, 2.0% for Class III division 2, 38.4% for Class III. 7. In the dental vertical dysplasia according to the Angle's classification, deep bite was the most frequent in Class II div.1 and div. 2(24.3%, 56.7%) and open bite in Class III(21.4%). 8. In the skeletal sagittal dysplasia, 39.3% of skeletal Class II was due to the undergrowth of the mandible and 46.3% of skeletal Class III was due to the overgrowth of the mandible. 9. Distribution in orthodontic treatment acceding to the extraction and nonextraction had shown 66.9% for nonextraction case, 33.1% for extraction case, and four first bicuspids have been extracted in the highest percentage(38.6%). 10. Patients who had orthognathic surgery comprised 7.9%, with an increasing trend.

  • PDF

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

A cephalometric investigation on the craniofacial configurations of Class ll division 1 and 2 in Korean (한국인 II급 1류 및 2류 부정교합자 두개안면형태의 차에 대한 측모두부방사선계측학적 연구)

  • Kang, Jong-Won;Lee, Young-Jun;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.32 no.3 s.92
    • /
    • pp.195-207
    • /
    • 2002
  • Numerous studies have revealed the similarities and discrepancies in two divisions of class II malocclusion, since these malocclusion groups have been postulated to be disparate criterion, much as classified under one diagnostic umbrella. This study was undertaken to describe the craniofacial configurations of class II division 1 and 2, and consequently to discriminate the morphologic differences between the two malocclusion groups in Korean sample. Lateral headfilms of 34 class H division 1 and 29 division 2 were employed, while those of 142 adults of normal occlusion served as a control. The landmarks were digitized and 26 variables were statistically analyzed for one way ANOVA. 1. There manifested no statistically significant difference in maxillary position anteroposteriorly. Normal occlusion group exhibited most anteriorly positioned mandible, whereas class II division 1 showed the most retroposition. Class II division 1 disclosed clockwise rotation tendency of mandible, which resulted in position of the chin Posteriorly. 2. Class II division 1 showed greater in SN to MP, SN to PP significantly than other groups. 3. Class II division 2 showed smaller genial angle and larger mandibular body length than other groups. 4. Class II division 1 revealed greater anterior lower face height than other groups, whereas division 2 dictated significantly greater posterior face height. 5. Class II division 2 expressed the most retroclined lower incisor, while division 1 manifested the most proclination. The largest interincisal angle resided in Class II division 2 group. There were no significant differences in upper molar position anteroposteriorly.

THE CLINICAL APPLICATION OF BUCCAL ACRYLIC APPLIANCES (Buccal acrylic appliance의 임상적 적용)

  • Noh, Hong-Seok;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.315-321
    • /
    • 2007
  • Removable appliance has many utilities in pediatric dentistry in the fields of space maintainance or occlusal guidance. In contrast to maxilla, many problems have occurred with mandible in using removable appliance such as deteriorated retention, inconvenience and patient's unwillingness to wear. It is probably due to adapting several retentive clasps at buccal side of the tooth, where there is actually little or no undercut especially in young children having the erupting teeth Moreover, acrylic base plate of conventional removable appliance is located at lingual parts, which leads to the conflict with alveolar crest undercut and sublingual soft tissues. Moreover, young children frequently do not follow the dentist's direction to elevate tongue properly during the impression taking process. Throughout this study, the position of clasps and acrylic baseplate was changed opposite to the traditional Hawley acrylic appliance in order to make a buccal acrylic appliance with buccal base plate and lingual clasp into primary dentition and early mixed dentition. This study was performed for the purpose of evaluating the buccal acrylic appliance in regards of patient compliance, retention and efficiency compared with traditional lingual acrylic appliance along with its merits and demerits. Buccal and lingual acrylic appliance were applied to 5 cases respectively which required space maintaining and tooth movement, and drew a comparison in relevance to patients' compliance, combination with the tongue's function and clinical effectiveness. According to this study, in every case buccal appliance was proved superior to lingual appliance in terms of retention and patients' compliance. Moreover, buccal appliance has shown to be similar to lingual appliance with respect to clinical effectiveness. Throughout this study, it was thought that, if removable appliance is to be applied to mandible, several drawbacks related to conventional lingual appliance shall be resolved. Conclusively, the buccal acrylic appliance is thought to be a good alternative in designing a mandibular appliance in young children and recommended to clinical applications.

  • PDF

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures (하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포)

  • Sung, Chai-Ryun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.375-390
    • /
    • 2009
  • Statement of problem: Implant supported overdenture is accepted widely as a way to restore edentulous ridge providing better retention and support of dentures. Various types of attachment for overdenture have been developed. Purpose: The purpose of this study was to investigate the influence of attachment type in implant overdentures on the biomechanical stress distribution in the surrounding bone, prosthesis and interface between implant and bone. Material and methods: Finite element analysis method was used. Average CT image of mandibular body(Digital $Korea^{(R)}$, KISTI, Korea) was used to produce a mandibular model. Overdentures were placed instead of mandibular teeth and 2mm of mucosa was inserted between the overdenture and mandible. Two implants($USII^{(R)}$, Osstem, Korea) were placed at both cuspid area and 4 types of overdenture were fabricated ; ball and socket, Locator, magnet and bar type. Load was applied on the from second premolar to second molar tooth area. 6 times of finite element analyses were performed according to the direction of the force $90^{\circ}$, $45^{\circ}$, $0^{\circ}$ and unilateral or bilateral force applied. The stress at interface between implants and bone, and prosthesis and the bone around implants ware compared using von Mises stress. The results were explained with color coded graphs based on the equivalent stress to distinguish the force distribution pattern and the site of maximum stress concentration. Results: Unilateral loading showed that connection area between implant fixture and bar generated maximum stress in bar type overdentures. Bar type produced 100 Mpa which means the most among 4 types of attachments. Bilateral loading, however, showed that bar type was more stable than other implants(magnet, ball and socket). 26 Mpa of bar type was about a half of other types on overdenture under $90^{\circ}$ bilateral loading. Conclusions: In any directions of stress, bar type was proved to be the most vulnerable type in both implants and overdentures. Interface stress did not show any significant difference in stress distribution pattern.