• Title/Summary/Keyword: 치료 초음파

Search Result 713, Processing Time 0.036 seconds

Assessment of the Severity of Degenerative Aortic Stenosis: Three Case Reports (퇴행성 대동맥판 협착증의 중증도 평가: 증례보고 3례)

  • Kim, Sung-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.270-275
    • /
    • 2019
  • The incidence of degenerative valve disease also increasing with the increasing life expectancy of the elderly population. Rheumatic valve disease is decreasing gradually and the incidence of calcified degenerative aortic stenosis (AS) is growing. Echocardiography is a very important tool for evaluating the prognosis and treatment method as well as the time of operation and diagnosis of heart valve disease. When evaluating valvular heart disease, 2-dimensional echocardiography, which observes all heart valves in detail, should take precedence. Understanding the clinical findings of degenerative valve disease and performing precise echocardiography are extremely important. In addition, an assessment of the severity of aortic stenosis is necessary to determine the surgical indications. An assessment of the severity by echocardiography was explained with three cases of degenerative aortic stenosis. To perform echocardiography accurately, it is necessary to understand degenerative valve disease and its clinical findings accurately.

Effects of skin temperature change, cold pain and muscle activity by Cold Air Application type on the induced delayed onset muscle soreness (지연성 근육통 유발 후 냉기 적용 방법이 피부온도의 변화, 냉각 통과 근육 기능에 미치는 효과)

  • Choi, Yoorim;Jung, Bongjae;Hwang, Byeongjun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study was to after induced delayed onset muscle soreness, the purpose of this study is to present the effective way on skin temperature changes and cold pain for 14 subjects during to applied with only Cold-jet stream and Cold-jet stream with infra red. 14 healthy men and women who delayed onset muscle soreness eccentric contractions induced by exercise and then the biceps alone was applied to the Cold-jet stream. We measured the time that skin temperature fall from room temperature to $10^{\circ}C$(first period), the time rewarmed from $10^{\circ}C$ to $20^{\circ}C$(second period), the time fall again to $10^{\circ}C$(third period) and the time rewarmed again to $20^{\circ}C$(fourth period). Cold-jet stream with infrared combination therapy was performed with the same method. Results of this study were 1st and 2nd experimental cooling experiments in the to fall to $10^{\circ}C$ Cold-jet stream with infrared combination therapy than in the Cold-jet stream was longer(p<.05). At second period, It took longer in Cold-jet stream with infrared rewarmed than Cold-jet stream to rewarm skin(p<.05). Cold-jet stream with infrared combination therapy than Cold-jet stream had less incidence of cold pain(p<.05). Thickness of biceps brachii were found significant difference related measurment each group was consistent. In this study, Cold-jet stream with infrared combination therapy more effective than Cold-jet stream in reduced cold pain and lowering skin temperature. This work was supported by education capacity building project fund of Taegu Science University, 2012.

A comparison of bladder volume by sonogram and CBCT for Pelvic region cancer (골반부 암 치료 시 초음파검사를 통한 방광체적과 CBCT영상 방광체적의 비교)

  • Son, Seong Ho;Park, Ha Ryung;Baek, Jung Jin;Son, Jong Ki;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.7-12
    • /
    • 2019
  • Purpose: During the pelvic radiation therapy, it is performed with controlling bladder volume because the range of irradiation is changed depending on the bladder volume. Therefore in this study, we evaluate the accuracy of BVI by tracing the change of bladder volume using ultrasonic pulse diagnosis equipment(BVI 6100, Medical supply Co. LTD) Material and Methods: From January 2017 to September 2018, 19 patients who received pelvic radiation therapy at Pusan National University Hospital were included. To treat the patient, we compared that the bladder volume obtained from the BVI and the bladder volume obtained from the CBCT image then we evaluated for significance. Results: There was a significant correlation of r=0.773, BVI and CBCT in the whole volume section. However, based on the bladder volume in the RTP Image the p value was shown to be 0 at 125~175cc and lower than 0.05 at 175~275cc, And more than 0.05 at 275~375cc. Conclusions: In this study, the patient whose bladder volume is above than 275cc, there is a significance of bladder volume between BVI and CBCT image. However, we could make a decision to be undermined the reliability of BVI measurement in the case of the patient with emptied his urine. Therefore, it is possible to acquire a significant value for 175~275cc patients to use the correction value of BVI and the appropriate tolerance of volume.

Fabrication of the ultrasonic circular array transducer (원형 배열 초음파 트랜스듀서의 개발)

  • Kim Hee-won;Roh Yongrae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.353-356
    • /
    • 2002
  • 심근 경색 및 뇌졸중 등 혈관과 관련된 질환들의 진단 및 치료의 목적으로 미세 크기의 원형 배열 초음파 트랜스듀서가 사용되고 있다. 원형 배열 초음파 트랜스듀서는 종래의 선형 배열 트랜스듀서에 비해 반경 방향의 입체적 진단을 가능케 하고 높은 감도 및 해상도를 구현할 수 있는 장점을 가진다. 본 연구에서는 이러한 원형 배열 초음파 트랜스듀서의 개발을 위하여, 유한요소법 및 이론적인 해석으로 트랜스 eb서의 방사특성을 분석함으로써 무지향성을 이루기 위한 트랜스듀서 내 진동자의 최적 규격을 설정하였다. 나아가 해석 결과에 따라 직경이 약 10mm정도가 되는 알루미나 $Al_2O_3$ 튜브에 32개의 진동자가 원형으로 배열된 트랜스 듀서 시작품의 제작 및 방사특성 측정 실험을 수행함으로써 설계 결과의 타당성을 검증하였다.

  • PDF

Phonophoretic Transdermal Drug Delivery of Triamcinolone acetonide gel (트리암시놀론 겔의 음파영동 경피약물흡수)

  • Kim Tae-Youl;Kim Gye Yeop
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.219-233
    • /
    • 2002
  • 스테로이드성 소염진통제인 트리암시놀론 겔의 피부투과도를 향상시키기 위하여 초음파를 조사하여 약물의 투과도에 미치는 영향을 비교하였다. 트리암시놀론을 함유한 수용성 겔을 제조하여 물리화학적 시험을 실시하였으며 carbopol을 기제로한 겔이 우수한 제제학적 특성을 보였다. 초음파 조사가 약물의 투과도에 미치는 영향을 알아보기 위하여 hairless mouse의 적출 피부에 대한 in vitro 흡수 실험을 실시하였다. 트리암시놀론 겔 음파영동군이 트리암시놀론겔 단독 처치군에 비하여 투과도가 유의적으로 향상되었다. 특히 주파수가 1MHz인 지속초음파를 고 강도로 적용시 피부투과도의 향상이 더욱 두드러졌다. 따라서 트리암시놀론 겔 도포 후 초음파를 이용한 음파영동 경피흡수가 단독의 겔 처치보다 피부투과에 유용할 것으로 사료된다.

  • PDF

Development of communcation signal interference removal module between High-Intensity Focused Ultrasound Devices using CAN communication (CAN 통신을 이용한 고강도 집속 초음파 디바이스간의 통신 신호 간섭 제거 모듈 개발)

  • Park, Jong-Cheol;Lee, Jin-Wook;Kim, Min-Sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.463-465
    • /
    • 2022
  • The high-intensity focused ultrasound device intermittently operates abnormally due to communication signal interference between the devices during use due to the high frequency radiated during the skin treatment procedure. Communication interference between multi-frequency ultrasound devices can be reduced through CAN communication controller and transceiver design, firmware S/W program and CAN communication module development.

  • PDF

Popliteal Arterial Compression Caused by Osteochondroma: Usefulness of Doppler Ultrasonography (골연골종에 의한 슬와동맥 압박: 도플러 초음파의 유용성)

  • Jeong, Woong-Kyo;Kim, Ho-Joong;Lee, Soon-Hyuck
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.2
    • /
    • pp.69-73
    • /
    • 2010
  • Osteochondroma arising around the knee joint may sometimes be associated with vascular complication. Angiography is widely used to demonstrate the vascular complication, but it is invasive. Recently MR angiography is recommended as a non-invasive alternative, but it is very costly. We report a twenty-year-old man with popliteal arterial compression caused by osteochondroma who was diagnosed and assessed the surgical result by Doppler ultrasonography. And we also provide the usefulness of Doppler ultrasonography.

  • PDF

A Study on the Implementation of Ultrasonic Guidance Algorithm for Improving Safety of Ultrasonic Varicose Vein Treatment (초음파 하지정맥류 치료의 안전성 개선을 위한 초음파 유도 알고리즘 구현에 관한 연구)

  • Kim, Seong-Cheol;Kim, Ju-Young;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.435-441
    • /
    • 2018
  • In this study, we performed to design an image guiding algorithm to improve the efficiency and safety of treatment of varicose vein by focused ultrasound. The algorithm was suggested by different guiding images according to the location of varicose veins. In the case of deep-seated varicose veins, the target area was marked on the surface of the blood vessel in the obtained cross-sectional blood vessel ultrasound image. In the case of the superficial varicose vein, A guiding system based on image segmentation algorithm of the vascular region was suggested and designed two different algorithms according to varicose veins progression degree. as a results, the algorithm based on ultrasound image show a small error with $830{\mu}m$ at maximum. However, the algorithm based on charge coupled device image has a maximum error of 8.3 mm in some data. Therefore, it is expected that additional study is needed for superficial varicose vein image guiding algorithm, and it is expected that the accuracy of blood vessel tracking should be evaluated by constructing simple system.

Combined Effects of Ionizing Radiation and Ultrasound on Malformation in ICR Mice at Organogenesis stage

  • Gu, Yeun-Hwa;Hasegawa, Takeo;Mori, Takehiko;Yamamoto, Youichi;Kusama, Tomoko
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 1999
  • Pregnant ICR mice were treated with 137Cs gamma-ray / ultrasound on day 8 of gestation. In combined treatments, pregnant mice were treated with both 1.5 Gy of radiation and $1.0W/cm^2$ ultrasound at time intervals of -1, 0, 1, 3 and 6 hours. The mortalities and external malformations were investigated on day 18 of gestation. The threshold dose of mortality induced by radiation on day 8 of gestation was between 0.5 and 1.0 Gy, and that which was induced by ultrasound was between 1.0 and $1.5W/cm^2$. The mortalities in the late-stage of gestation induced by combined treatment with radiation and ultrasound increased synergistically. The threshold dose of exencephaly and anophthalmia induced by radiation were between 0.5 and 1.0 Gy and between 1.0 and 1.5 Gy, respectively. Those of exencephaly and anophthalmia induced by ultrasound were between 1.0 and $1.5W/cm^2$ and more than $1.5W/cm^2$, respectively. In combined treatments, the incidence of exencephaly and anophthalmia were found to increase synergistically. In the mice treated with both agents at a time interval of one hour, the incidence of exencephaly and anophthalmia reached maximum levels.

  • PDF

Endovenous 980-nm Diode Laser Treatment of Incompetent Great Saphenous Vein (정맥 내 980-nm 다이오드 레이저를 이용한 대복재정맥 역류의 치료)

  • Kim, Kun-Il;Jo, Tae-Jun;Lee, Jae-Woong;Hong, Ki-Woo;Lee, Won-Yong
    • Journal of Chest Surgery
    • /
    • v.40 no.2 s.271
    • /
    • pp.97-102
    • /
    • 2007
  • Background: Endovenous laser treatment has recently been introduced as a less invasive technique, with many good results reported, A 980-nm diode laser was used on the great saphenous vein (GSV) occlusions in patients with varicose veins, due to GSV reflux, and the therapeutic effects analyzed. Material and Method: Between September 2003 and February 2006, 238 patients (332 cases) with GSV reflux underwent endovenous laser treatment with a 980-nm diode laser. Operative procedures were simultaneous endovenous laser treatment and ambulatory phlebectomy. The preoperative clinical findings, postoperative complications and postoperative duplex US follow up results at 1 and 3 months were reviewed. Result: Postoperative complications were ecchymosis in almost cases, paresthesia 68 cases (20.5%) and skin burn in 3 cases (0.9%). Follow up duplex US revealed 26 and 10 cases at 1 and 3 months of GSV reflux or partial recanalization, with therapeutic success rates of 91.3 and 87.9%, respectively. Conclusion: The treatment of GSV occlusion with an endovenous laser is less invasive than traditional GSV stripping, but relatively high recanalization was experienced, possibly due to inadequate laser power, laser fiber pullback speed or an extremely dilated GSV. However, continuous attempts will be required to reduce the recanalization after the procedure, with accurate follow up using duplex US.