• Title/Summary/Keyword: 치료권고안

Search Result 43, Processing Time 0.024 seconds

Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files (Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가)

  • Kim, Joo Seob;Ahn, Woo Sang;Lee, Woo Suk;Park, Sung Ho;Choi, Wonsik;Shin, Seong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.305-312
    • /
    • 2014
  • Purpose : The purpose of this study is to analyze the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC) and determine the appropriate period of quality assurance (QA). Materials and Methods : The quality assurance of the DMLC equipped with Millennium 120 leaves has been performed total 92 times from January 2012 to June 2014. The the accuracy of leaf position and isocenter coincidence for MLC were checked using the graph paper and Gafchromic EBT film, respectively. The stability of leaf speed was verified using a test file requiring the leaves to reach maximum leaf speed during the gantry rotation. At the end of every leaf speed QA, dynamic dynalog files created by MLC controller were analyzed using dynalog file viewer software. This file concludes the information about the planned versus actual position for all leaves and provides error RMS (root-mean square) for individual leaf deviations and error histogram for all leaf deviations. In this study, the data obtained from the leaf speed QA were used to screen the performance degradation of leaf speed and determine the need for motor replacement. Results : The leaf position accuracy and isocenteric coincidence of MLC was observed within a tolerance range recommanded from TG-142 reports. Total number of motor replacement were 56 motors over whole QA period. For all motors replaced from QA, gradually increased patterns of error RMS values were much more than suddenly increased patterns of error RMS values. Average error RMS values of gradually and suddenly increased patterns were 0.298 cm and 0.273 cm, respectively. However, The average error RMS values were within 0.35 cm recommended by the vendor, motors were replaced according to the criteria of no counts with misplacement > 1 cm. On average, motor replacement for gradually increased patterns of error RMS values 22 days. 28 motors were replaced regardless of the leaf speed QA. Conclusion : This study performed the periodic MLC QA for analyzing the mechanical and leaf speed accuracy of the dynamic multileaf collimator (DMLC). The leaf position accuracy and isocenteric coincidence showed whthin of MLC evaluation is observed within the tolerance value recommanded by TG-142 report. Based on the result obtained from leaf speed QA, we have concluded that QA protocol of leaf speed for DMLC was performed at least bimonthly in order to screen the performance of leaf speed. The periodic QA protocol can help to ensure for delivering accurate IMRT treatment to patients maintaining the performance of leaf speed.

The Korean Practice Parameter for the Treatment of Attention-Deficit Hyperactivity Disorder(I) - Introduction, Clinical Features and Course - (주의력결핍 과잉행동장애 한국형 치료 권고안(I) -서론, 임상 양상 및 경과-)

  • Ahn, Dong-Hyun;Kang, Hwa-Yeon;Kim, Bung-Nyun;Kim, Ji-Hoon;Shin, Dong-Won;Yang, Su-Jin;Yoo, Han-Ik;Yoo, Hee-Jeong;Cheon, Keun-Ah;Hong, Hyun-Ju
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2007
  • Based on the broad and in-depth literature review, the dedicated members of the committee for the development of Korean attention-deficit hyperactivity disorder (ADHD) practice parameter develop the Korean practice parameter for ADHD. Members of the Korean Academy of child and Adolescent Psychiatry (KACAP) had reviewed the drafts through off-line and on-line access to the drafts. Feedbacks from the members of KACAP were carefully integrated into the current practice parameter. This article presents the state of the art knowledge regarding the assessment and the management of ADHD. Recommendations in the end of the practice parameter may help clinician to make decisions in clinical practice, but are not likely to override the clinician's decision in natural settings. Future directions to complement the limitation of the current practice parameter is suggested.

  • PDF

A Systematic Review of Randomized Controlled Trials on Acupuncture for Shoulder Pain Based on Jadad Scale and revised STRICTA recommendations (견비통에 대한 침치료 임상연구의 체계적 문헌 고찰 - Jadad Scale 및 개정된 STRICTA 권고안을 중심으로 -)

  • Park, Tae-Hyun;Oh, Chang-Keun;Park, Yu-Lee;Yang, Seung-Bum;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.93-108
    • /
    • 2012
  • Objectives : This study aims to review randomized controlled trials on acupuncture for shoulder pain according to Jadad Scale and revised STRICTA. Methods : Seven electronic databases including PUBMED, SCOPUS, RISS were searched for randomized controlled trials (RCT) of acupuncture for shoulder pain. Results : 16 RCTs were included: 14 were published in English and 2 were published in Korean. According to Jadad scale, 15 RCTs had high quality. However, most of the studies could not meet the double blindness criteria. All RCTs meet 12.9 items on average in STRICTA. Conclusions : This systematic review shows four conclusions as follows. Traditional Chinese Medicine is often used in style of acupuncture. Spots of LI15, TE14, GB21 and LI11, stainless steel needle($0.3mm{\times}40mm$), 20 retention time, manual stimulation, $Deqi$, and 2 times a week treatment (total 12) are often used. Double-blinded clinical trials needs to be conducted. It is controversial to use minimal acupunctures on controlled groups of RCTs on acupuncture for shoulder pain. Description about practitioner's background needs clarifying.

Current Applications and Future Perspectives of Brain Tumor Imaging (뇌종양 영상의 현재와 미래)

  • Ji Eun Park;Ho Sung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.467-487
    • /
    • 2020
  • Anatomical imaging is the basis of the diagnosis and treatment response assessment of brain tumors. Among the existing imaging techniques currently available in clinical practice, diffusion-weighted imaging and perfusion imaging provide additional information. Recently, with the increasing importance of evaluation of the genomic variation and heterogeneity of tumors, clinical application of imaging techniques using radiomics and deep learning is expected. In this review, we will describe recommendations for magnetic resonance imaging protocols focusing on anatomical images that are still important in the clinical application of brain tumor imaging, and the basic principles of diffusion-weighted imaging and perfusion imaging among the advanced imaging techniques, as well as their pathophysiological background and clinical application. Finally, we will review the future perspectives of radiomics and deep learning applications in brain tumor imaging, which have been studied to a great extent due to the development of computer technology.

Comparison of Treatment Planning on Dosimetric Differences Between 192Ir Sources for High-Dose Rate Brachytherapy (고선량률 근접치료에서 이리듐-192 선원의 선량특성 차이에 관한 치료계획 비교)

  • Yang, Oh-Nam;Shin, Seong Soo;Ahn, Woo Sang;Kim, Dae-Yong;Kwon, Kyung-Tae;Lim, Cheong-Hwan;Lee, Sang Ho;Choi, Wonsik
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.163-170
    • /
    • 2016
  • To evaluate whether the difference in geometrical characteristics between high-dose-rate (HDR) $^{192}Ir$ sources would influence the dose distributions of intracavitary brachytherapy. Two types of microSelectron HDR $^{192}Ir$ sources (classic and new models) were selected in this study. Two-dimensional (2D) treatment plans for classic and new sources were generated by using PLATO treatment planning system. We compared the point A, point B, and bladder and rectum reference points based on ICRU 38 recommendation. The radial dose function of the new source agrees with that of the classic source except difference of up to 2.6% at the nearest radial distance. The differences of anisotropy functions agree within 2% for r=1, 3, and 5 cm and $20^{\circ}$ < ${\theta}$ < $165^{\circ}$. The largest discrepancies of anisotropy functions reached up to 27% for ${\theta}$ < $20^{\circ}$ at r=0.25 cm and were up to 13%, 10%, and 7% at r=1, 3, and 5 cm for ${\theta}$ > $170^{\circ}$, respectively. There were no significant differences in doses of point A, point B, and bladder point for the treatment plans between the new and classic sources. For the ICRU rectum point, the percent dose difference was on average 0.65% and up to 1.0%. The dose discrepancies between two treatment plans are mainly affected due to the geometrical difference of the source and the sealed capsule.

Training of Radiofrequency Ablation for Thyroid Nodules in Korea: Current and Future Perspective (국내의 갑상선 고주파 절제술에 대한 교육: 현황 및 미래 전망)

  • Hye Shin Ahn;So Lyung Jung;Jung Hwan Baek;Jin Yong Sung;Ji-hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1009-1016
    • /
    • 2023
  • Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules and recurrent thyroid cancers. In Korea, RFA for thyroid nodules was first performed in 2002, and a large population study was published in 2008. The Task Force Committee of the Korean Society of Thyroid Radiology (KSThR) developed its first recommendations for RFA in 2009, which were revised in 2012 and 2018. The KSThR guideline was the first guideline for RFA of thyroid nodules worldwide and has become a guideline for physicians to perform thyroid RFA in Korea and other countries around the world. These guidelines have contributed significantly to the establishment and widespread use of RFA worldwide. In addition, since 2015, the KSThR has conducted intensive hands-on courses depending on the level of the participants. In this article, the authors introduce the history of eduction for RFA conducted by the KSThR and describe the learning curve of RFA and current training programs in Korea, along with future directions for training programs.

A Study on Mechanical Errors in Cone Beam Computed Tomography(CBCT) System (콘빔 전산화단층촬영(CBCT) 시스템에서 기계적 오류에 관한 연구)

  • Lee, Yi-Seong;Yoo, Eun-Jeong;Kim, Seung-Keun;Choi, Kyoung-Sik;Lee, Jeong-Woo;Suh, Tae-Suk;Kim, Joeng-Koo
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • This study investigated the rate of setup variance by the rotating unbalance of gantry in image-guided radiation therapy. The equipments used linear accelerator(Elekta Synergy TM, UK) and a three-dimensional volume imaging mode(3D Volume View) in cone beam computed tomography(CBCT) system. 2D images obtained by rotating $360^{\circ}$and $180^{\circ}$ were reconstructed to 3D image. Catpan503 phantom and homogeneous phantom were used to measure the setup errors. Ball-bearing phantom was used to check the rotation axis of the CBCT. The volume image from CBCT using Catphan503 phantom and homogeneous phantom were analyzed and compared to images from conventional CT in the six dimensional view(X, Y, Z, Roll, Pitch, and Yaw). The variance ratio of setup error were difference in X 0.6 mm, Y 0.5 mm Z 0.5 mm when the gantry rotated $360^{\circ}$ in orthogonal coordinate. whereas rotated $180^{\circ}$, the error measured 0.9 mm, 0.2 mm, 0.3 mm in X, Y, Z respectively. In the rotating coordinates, the more increased the rotating unbalance, the more raised average ratio of setup errors. The resolution of CBCT images showed 2 level of difference in the table recommended. CBCT had a good agreement compared to each recommended values which is the mechanical safety, geometry accuracy and image quality. The rotating unbalance of gentry vary hardly in orthogonal coordinate. However, in rotating coordinate of gantry exceeded the ${\pm}1^{\circ}$ of recommended value. Therefore, when we do sophisticated radiation therapy six dimensional correction is needed.

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

The 1998, 1999 Patterns of Care Study for Breast Irradiation After Breast-Conserving Surgery in Korea (1998, 1999년도 우리나라에서 시행된 유방보존수술 후 방사선치료 현황 조사)

  • Suh Chang-Ok;Shin Hyun Soo;Cho Jae Ho;Park Won;Ahn Seung Do;Shin Kyung Hwan;Chung Eun Ji;Keum Ki Chang;Ha Sung Whan;Ahn Sung Ja;Kim Woo Cheol;Lee Myung Za;Ahn Ki Jung
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.192-199
    • /
    • 2004
  • Purpose: To determine the patterns on evaluation and treatment in the patient with early breast cancer treated with conservative surgery and radiotherapy and to improve the radiotherapy techiniques, nationwide survey was peformed. Materials and Methods: A web-based database system for korean Patterns of Care Study (PCS) for 6 common cancers was developed. Two hundreds sixty-one randomly selected records of eligible patients treated between 1998$\~$1999 from 15 hospitals were reviewed. Results: The patients ages ranged from 24 to 85 years(median 45 years). Infiltrating ductal carcinoma was most common histologic type (88.9$\%$) followed by medullary carcinoma (4.2$\%$) and infiltrating lobular carcinoma (1.5$\%$). Pathologic T stage by AJCC was T1 in 59.7$\%$ of the casses, T2 in 29.5$\%$ of the cases, Tis in 8.8$\%$ of the cases. Axillary lymph node dissection was peformed I\in 91.2$\%$ of the cases and 69.7$\%$ were node negative. AJCC stage was 0 in 8.8$\%$ of the cases, stage I in 44.9$\%$ of the cases, stage IIa in 33.3$\%$ of the cases, and stage IIb in 8.4$\%$ of the cases. Estrogen and progesteron receptors were evaluated in 71.6$\%$, and 70.9$\%$ of the patients, respectively. Surgical methods of breast-conserving surgery was excision/lumpectomy in 37.2$\%$, wide excision in 11.5$\%$, quadrantectomy in 23$\%$ and partial mastectomy in 27.5$\%$ of the cases. A pathologically confirmed negative margin was obtained in 90.8$\%$ of the cases. Pathological margin was involved with tumor in 10 patients and margin was close (less than 2 mm) in 10 patients. All the patients except one recieved more than 90$\%$ of the planned radiotherapy dose. Radiotherapy volume was breast only In 88$\%$ of the cases, breast+supraclavicular fossa (SCL) in 5$\%$ of the cases, and breast+ SCL+ posterior axillary boost in 4.2%$\%$of the cases. Only one patient received isolated internal mammary lymph node irradiation. Used radiation beam was Co-60 in 8 cases, 4 MV X-ray in 115 cases, 6 MV X-ray in 125 cases, and 10 MV X-ray in 11 cases. The radiation dose to the whole breast was 45$\~$59.4 Gy (median 50.4) and boost dose was 8$\~$20 Gy (median 10 Gy). The total radiation dose delivered was 50.4$\~$70.4 Gy (median 60.4 Gy). Conclusion: There was no major deviation from current standard in the patterns of evaluation and treatment for the patients with early breast cancer treated with breast conservation method. Some varieties were identified in boost irradiation dose. Separate analysis for the datails of radiotherapy planning will be followed and the outcome of treatment is needed to evaluate the process.

The Korean Practice Parameter for the Treatment of Attention - Deficit Hyperactivity Disorder(II) - Diagnosis and Assessment - (주의력결핍 과잉행동장애 한국형 치료 권고안(II) - 진단 및 평가 -)

  • Cheon, Keun-Ah;Kim, Ji-Hoon;Kang, Hwa-Yeon;Kim, Bung-Nyun;Shin, Dong-Won;Ahn, Dong-Hyun;Yang, Su-Jin;Yoo, Han-Ik;Yoo, Hee-Jeong;Hong, Hyun-Ju
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 2007
  • Probably the three most important components to a comprehensive evaluation of patients with attention-deficit hyperactivity disorder (ADHD) are the clinical interview, the medical examination, and the completion and scoring or behavior rating scales. Teachers and other school personnel are often the first to recognize that a child or adolescent might have ADHD, and often play an important role in the help-seeking/referral process. A diagnostic evaluation for ADHD should include questions about ADHD symptoms, other problems including alcohol and drug use, family history of ADHD, prior evaluation and treatment for ADHD. Screening interview or rating scales as well as interviews should be used. When it is feasible, clinicians may wish to supplement these components of the evaluation with objective assessments of the ADHD symptoms, such as psychological tests. These tests are not essential to reaching a diagnosis, however, or to treatment planning, but they may yield further information about the presence and severity of cognitive impairments that could be associated with some cases of ADHD. Screening for intellectual ability and academic achievement skills is also important in determining the presence of comorbid developmental delay or loaming disabilities. The number and type of symptoms required for a diagnosis of ADHD vary depending on the specific subtype. To receive a diagnosis of ADHD, the person must be experiencing significant distress or impairment in daily functioning, and must not meet criteria for other mental disorders which might better account for the observed symptoms such as mental retardation, autism or other pervasive developmental disorders, mood disorders, anxiety disorders. This report aims to suggest a practice guideline of assessment and diagnosis for children and adolescents with ADHD in Korea.

  • PDF