• Title/Summary/Keyword: 치과 임플란트 보철물

Search Result 316, Processing Time 0.025 seconds

Retrospective study on survival, success rate and complication of implant-supported fixed prosthesis according to the materials in the posterior area (구치부 임플란트 지지 고정성 보철물의 재료에 따른 생존율, 성공률 및 합병증에 대한 후향적 연구)

  • Chae, Hyun-Seok;Wang, Yuan-Kun;Lee, Jung-Jin;Song, Kwang-Yeob;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.342-349
    • /
    • 2019
  • Purpose: The purpose of this study was to retrospectively investigate the survival and success rate of implant-supported fixed prosthesis according to the materials in the posterior area. Other purposes were to observe the complications and evaluate the factors affecting failure. Materials and methods: Patients who had been restored implant prosthesis in the posterior area by the same prosthodontist in the department of prosthodontics, dental hospital, Chonbuk National University, in the period from January 2011 to June 2018 were selected for the study. The patient's sex, age, material, location, type of prosthesis and complications were examined using medical records. The KaplanMeier method was used to analyze the survival and success rate. The Log-rank test was conducted to compare the differences between the groups. Cox proportional hazards model was used to assess the association between potential risk factors and success rate. Results: A total of 364 implants were observed in 245 patients, with an average follow-up of 17.1 months. A total of 5 implant prostheses failed and were removed, and the 3 and 5 year cumulative survival rate of all implant prostheses were 97.5 and 91.0, respectively. The 3 and 5 year cumulative success rate of all implant prostheses were 61.1% and 32.9%, respectively. Material, sex, age, location and type of prosthesis did not affect success rate (P>.05). Complications occurred in the order of proximal contact loss (53 cases), retention loss (17 cases), peri-implant mucositis (12 cases), infraocclusion (4 cases) and so on. Conclusion: Considering a high cumulative survival rate of implant-supported fixed prostheses, regardless of the materials, implant restored in posterior area can be considered as a reliable treatment to tooth replacement. However, regular inspections and, if necessary, repairs and adjustments are very important because of the frequent occurrence of complications.

Restoration of bilateral distal extension removable partial denture using a fixed implant prosthesis in unilateral partial edentulous patient: A case report (하악 편측 소수치 잔존 환자에서 임플란트 고정성 보철물을 사용하여 양측성 후방 연장 국소의치로 수복: 증례보고)

  • Kee, Wonjin;Park, Jae-Ho;Lim, Hyun-Pil;Yun, Kwi-Dug;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.176-181
    • /
    • 2019
  • Traditional removable partial denture is a successful treatment for partial edentulous patients. When the abutment is formed with unilateral minority teeth, satisfaction with the use of removable partial denture may be lowered due to patient's discomfort and damage of the abutment. Recently, it has been reported that the unilateral posterior extension partial denture is used as a bilateral posterior extension partial denture using implant fixed prostheses as abutments. In this case, by using implant surveyed crown prostheses, bilateral posterior extension partial denture is fabricated in site that is predicted to have a poor prognosis. This resulted in improved support, maintenance, and stabilization of the removable partial denture, which were economically beneficial to patient and satisfied with use.

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report (방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례)

  • Choi, Eun-Joo;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.218-224
    • /
    • 2017
  • The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

Study on the Correlation between Dental Implant Patients' Oral Hygiene Behaviors and Satisfaction (치과 임플란트 환자의 구강위생 관리행태와 만족도의 관련성 조사)

  • Moon, Seon-Jeong;Kim, Eun-Hee;Park, Hong-Ryurn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.576-584
    • /
    • 2015
  • This research studiedthe correlation between dental implant patients' oral hygiene behaviors and satisfaction. By doing so, this study seeks to provide the basic data for the development of diagonal and educational programs to improve implant prosthesis maintenance and satisfaction. The data was collected from January 7 to June 30, 2014, analyzed by SAS (ver 9.2) and for this research, 6 dental hospitals and clinics in Daegu, Busan and Jinju, South Korea were examined for their implant patients receiving treatment. As a result, a total of 266 sets of data were investigated herein to reach the following findings: 1. The survey on status of dental implant prosthesis use and maintenance knowledge found 1.41 on average out of the total score of 3. 2. In the survey on implant prosthesis maintenance after putting in, the dental scaling cycle was found to be 'none' (63.2%). 3. In the survey on implant use status and satisfaction with their implant prosthesis, the masticatory function (p=0.001) were found to be significantly higher in the group using such oral-hygiene goods. 4. In the correlation analysis among one's knowledge on dental implant maintenance, discomfort and satisfaction, it was found that the more they used oral-hygiene supplementary goods (${\beta}=0.095$), the more they had knowledge on implant maintenance (${\beta}=0.069$) and the more they experienced oral health education (${\beta}=0.032$), the higher their satisfaction levels were. It is deemed that, for enhanced satisfaction of dental implant patients, their maintenance behaviors need to be further improved through oral health educational programs.

Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up (완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰)

  • Shin, Mi-sun;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.312-320
    • /
    • 2019
  • One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction cases. Computer assisted planning systems and associated surgical templates have established a predictable, esthetic, functional technique for placing and restoring implants. Especially, a philosophy of restoratively driven implant placement has been generally adopted. Recently, a variety of commercial dental fields have released their scanning and fabricating protocols and methods for restorations. This process is still being investigated and developed for the most precise and predictable outcome. This case report describes a female patient who wanted dental implants in fully edentulous areas. Restoratively driven implant placements were performed with surgical guide and the patient was fully satisfied with the clinical results, and at 5-year post restorative follow-up assessment, both implant and prosthesis were proved clinical success.

Implant-assisted removable partial denture using digital guide surgery in partially edentulous mandible: A case report (하악 부분 무치악 환자에서 디지털 가이드 수술을 이용한 임플란트 융합 가철성 국소의치 수복 증례)

  • Kim, Taehoon;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeonjong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.88-96
    • /
    • 2021
  • Fixed implant prostheses or removable partial dentures are common treatment for partially dentulous patients. Recently, an implant-assisted removable partial denture (IARPD) has been introduced and is widely used. In the case of removable partial dentures using implant attachment and surveyed fixed prostheses, the consideration about parallelism of insertion path between implants and surveyed fixed prostheses is an important factor for success of IARPDs. In this case, she complained of discomfort while using the mandibular removable partial denture. Thus, an IARPD using implant surveyed fixed prostheses was fabricated. Thereafter, more implants were placed by a digital guide surgery to have the same insertion path as the existing surveyed fixed prostheses. Locator attachments were installed to the left and right premolar implants, and the left molar was able to obtain support of the removable partial denture with healing abutment. The clinical results were satisfactory on the aspect of aesthetic and masticatory function.

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

Clinical study on the food impaction between implant prostheses and adjacent teeth (임플란트 보철물과 인접치 사이의 식편압입에 관한 임상적 연구)

  • Shin, Dong-Wook;Lee, Jin-Han;Kim, Se-Yeon;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the food impaction between implant prostheses and adjacent natural teeth. Materials and methods: For this study, 51 patients with food impaction were selected and investigated mobility, tightness of contact area, gingival index, plaque index, attachment loss, alveolar bone level, proximal caries, marginal ridge distance and occlusal relationships. Results: Food impaction was found in the upper teeth (60.7%) more than the lower teeth (39.2%). Food impaction was occurred on mesial side of implant prostheses (86.2%) more than distal side (13.7%). Food impaction was mostly found in loose or open contact area (94.2%). Food impaction was frequent on stepped relationship between implant and adjacent teeth. Conclusion: Treatment plan should include proper adjacent and antagonistic occlusal plane and occlusal surface, to prevent food impaction, and the plan should include less adjacent tooth mobility with proper tightness between implant prostheses and adjacent teeth.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.