• Title/Summary/Keyword: 치과 심미

Search Result 1,137, Processing Time 0.023 seconds

MITIGATION OF MAXILLARY ANTERIOR TEETH PROTRUSION WITH CEREBRAL PALSY USING REMOVABLE APPLIANCE : A CASE REPORT (뇌성마비환자에서 가철성장치를 이용한 상악 전치부 돌출 완화 : 증례보고)

  • Min, Boram;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.9 no.2
    • /
    • pp.122-126
    • /
    • 2013
  • Cerebral palsy is one of the primary handicapping conditions of childhood. The prevalence of malocclusions in patients with cerebral palsy is approximately twice than in general population. Even though these high rates of malocclusions, most clinicians may feel uncomfortable about treating such problems to reduce inclination of anterior teeth because to reduce of protrusion makes to decrease risk of trauma. This is the case report about mitigation of maxillary anterior teeth protrusion in patient with cerebral palsy. A 14 year old boy who had cerebral palsy visited our dental hospital. He had severe protrusive maxillary anterior teeth and narrow arch form. He was experienced at using Castillo morales appliance in early childhood. He had mild mental retardation and was able to learn simple skills. He and his parents had willing to improve his dental problems. A gentle impression taking on maxilla was done. Removable appliance was made including median screw and labial bow. We provide a period of adaption for 3 weeks. After of anterior teeth through activation of labial bow was done once a month by dentist. The treatment carried out for 10 months and we could observe reduced labial inclination of maxillary right central incisor and more wide arch form. Hawley type retainer was set at maxilla for retention. In conclusion, accompanying careful case selection and treatment, patient with cerebral palsy can be treated and should not be ignored their orthodontic needs.

A Study on Color Differences Between Composite Resins and Shade Guides (복합레진과 shade guide의 색차에 관한 연구)

  • Kim, Hee-Sun;Um, Chung-Moon;Kahng, Myong-Whai
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.107-120
    • /
    • 1996
  • 복합레진은 조작이 용이하고 강도가 우수하며 중합시간이 짧고 법랑질과 상아질에 접착이 가능하며 연마성이 뛰어나고 자연스러운 색상을 나타내므로 심미적 수복에 가장 일반적으로 선택되는 재료의 하나이다. 대부분의 복합레진 kit에는 shade guide가 포함되어 있어 이를 기준으로 중합된 후의 복합레진 색조를 예상하여 선택하게 된다. 그러나 이러한 shade guide들은 대개 복합레진이 아닌 plastic으로 제조된 것으로 중합된 복합레진의 실제 색조와는 차이가 생기게 되며 결국 shade guide 자체의 문제점으로 인해 이상적인 색조선택이 어려워진다. 이에 본 연구에서는 국내에 시판되고 있는 5종의 복합레진 제품을 선정하여 분광 광도계를 이용해서 shade guide와 중합된 복합레진 사이의 색조차이를 측정, 비교 연구하였다. 직경 16mm. 두께 1.6mm의 plastic mold에 5종의 광중합형 복합레진(Z100, Prisma TPH, Tetric, Silux Plus, Herculite XR)을 충전하고 응축기에 넣어 압축한 후 제조사의 지시에 따라 광중합기로 중합시킨 후 mold에서 시편을 제거하여 보관했다가 젖은 sandpaper 상에서 순차적으로 연마하였다. shade guide는 step부분을 갈아내어 복합레진 시편과 동일한 두께로 만든후 연마하였다. 분광광도계에 shade guide를 넣고 CIE illuminant D65 하에서 spectral reflectance를 측정하고 해당 색조의 복합레진 시편도 통일한 방법으로 측정하고 $L^*$, $a^*$, $b^*$값과 ${\Delta}E^*$값을 얻은후 분석하여 다음과 같은 결과를 얻었다. 1. Z100의 D3, A3, B2 shade와 Prisma TPH의 B2 shade를 제외한 모든 시편에서 shade guide와 복합레진간에 육안으로 인지할 수 있는 색차(${\Delta}E^*$ > 1.0)가 관찰되었다. 2. 평균적으로 Z100이 가장 적은 색차를 나타내었고 Prisma TPH, Tetric, Silux Plus, Herculite XR 순으로 색차가 증가하였다. 3. Prisma TPH의 A2 shade. Tetric의 W shade. Silux Plus의 YB, U shade, Herculite XR의 L, LY shade는 ${\Delta}E^*$값이 3.3 이상으로 나타났다. 4. Z100, Prisma TPH, Tetric, Silux Plus에서는 복합레진보다 shade guide가 더 높은 $L^*$값을 보이는 경향이 나타났으며, Herculite XR에서만 복합레진이 더 높은 $L^*$값을 나타냈다. 5. 모든 시편에서 $b^*$ 값은 (+)로 관찰되었고, Z100, Prisma TPH, Tetric, Silux Plus의 shade guide는 복합레진에 비해 높은 $b^*$값을 보였다. 6. 모든 시편에서 $a^*$값은 (-)로 관찰되었고. Herculite XR 및 Silux Plus에서는 복합레진이 shade guide 에 비 해 낮은 $a^*$값을 나타냈다.

  • PDF

Influence of Low Temperature Degradation on Bond Strength of Yttria-Stabilized Tetragonal Zirconia Polycrystal Core to Veneering Ceramic (저온열화현상이 지르코니아 코어와 전장도재의 전단결합강도에 미치는 영향)

  • Kim, Ki-Baek;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.14 no.1
    • /
    • pp.29-34
    • /
    • 2014
  • The purpose of this study was to evaluate the influence of low temperature degradation (LTD) on the bonding strength of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP). The push-shear bond test method was used to investigate the core-veneer bonding strength of industrially manufactured Y-TZP core ceramic and manufacturer recommended veneering ceramic. Four groups from ceramic-zirconia specimens (n=28; n=7 per group) were assigned into four experimental aging conditions, namely storage in an autoclave at $134^{\circ}C$ for 0, 3, 5, 10 hours. Bonding strength was obtained using a universal testing machine with crosshead speed 0.5 mm/min. Data were statistically analyzed using one-way ANOVA and Tukey's test (${\alpha}=0.05$). In bonding strength test, the group which was treated with LTD showed lower bonding strength than no treated group. The ceramic-zirconia bonding strength was affected by LTD (p<0.05). Digital microscope examination of the fracture surface showed mixed failures with adhesive and cohesive types in LTD with treated Y-TZP groups.

365 nm LED laser treatment on beagle for gingival whitening without gum dermabrasion (잇몸 박피술 없는 치은 미백을 위한 비글에서 365 nm LED 레이저 치료)

  • Lee, Sung-Ho;Kim, Ryun Kyung;Seo, Na-Ri;Lim, Ho-Kyung;Byun, Soo-Hwan;Lim, Young-Joon;Kim, Soung-Min;Lee, Jong-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.117-122
    • /
    • 2016
  • Purpose: Gingival whitening is one of dental treatment purposes which is close to treating aesthetic disorders. Initial gingival whitening treatment was done by dermabrasion using a high power Diode Laser. However, this treatment method cannot be free from any infection or pain after the treatment. Therefore, we have decided to progress gingival whitening treatment using a low power LED laser. Materials and Methods: The laser was irradiated on pork meat then the safety of output power, temperature change and skin denaturalization was measured. Bison 365 nm LED laser was irradiated on oral mucosal pigment of a 15 - 20 kg beagle for 15 min for 1 - 2 weeks, one or two times each. Any pigment loss was checked through Hematoxyline-Eosin staining. Results: The melanin pigments at the area of 365 nm LED Laser irradiation were decreased. Conclusion: The 365 nm LED Laser proposed in this study is considered to compensate the bleaching effect achieved by either using Diode laser or surgical methods.

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

Applying the New Technology for Making Pontic Ridge Lap in Posterior Bridge Restoration (대체 신기법을 적용한 구치부 교의치 pontic ridge lap 제작방법)

  • Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.308-316
    • /
    • 2013
  • The purpose of this study is to investigate the production method of posterior bridges pontic ridge lap type which prevents the infection in bridge pontic base and is able to cleanse itself, in the process of producing final prothesis that maintains healthy mucous membrane of oral cavity and interproximal papilla, minimizing diastema, is aesthetic and has no effect on pronunciation. New technology is applied to make optimal pontic base which prevent inflammation and clean itself and its products were clinically evaluated in 10 places of dental clinics in busan and gyeongnam. The making of posterior 3 unit bridge pontic base, it was presented as the new technology of forming ridge lab type and to carry out clinical validation, existing conventional method and the new technology were compared. Pontic base made with the existing conventional method cause infection and other periodontal disease by 96% but the pontic base made with the new technology cause infection and other periodontal disease by 3%. Remains of food cause infection and other periodontal disease 100% by the existing conventional method and 91% by the new technology, showing a distinct difference. However, after a gargle, the new technology had low 13%. Additionally, the pontic base made with the existing conventional method showed 71% of chance, the new technology method showed 8% of chance in terms of self-cleansing.

Microhardness and microleakage of composite resin according to the change of curing light intensity (다양한 중합광도에 따른 복합레진의 미세 경도와 변연 누출도)

  • Soo-man Park;Dong-Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.363-371
    • /
    • 2001
  • 심미성 수복재 중합시 사용되는 광원은 다양한 요인들에 의해 선택되어지고 있지만 이러한 요인들은 앞으로도 논란의 여지를 많이 남겨두고 있다. 또한 현재 사용되고 있는 중합법들이 제각기 독특한 장점들을 갖고 있기 때문에 최적의 중합법 결정이 필요한 시점이다. 이에 본 연구에서는 중합광의 강도(50, 100, 200, 300, 400, 600mW/$\textrm{cm}^2$)와 중합시간(10, 20, 40초)을 다양하게 변화시켰을 때 복합레진의 미세경도와 미세누출도가 어떠한 양태를 보이는지를 관찰하고자 하였다. 본 실험에서는 A3 색상의 혼합형 복합레진인 국산 DenFil과 미세입자형 복합레진인 Esthet X를 사용하였다. 중합 1일 후 복합레진의 Vickers 경도는 다이아몬드형 압흔 길이를 측정하여 평가하였으며 미세누출도는 1% methylene blue용액을 이용한 방법과 주사전자 현미경을 이용한 수복물과 치질간의 최대 이개도 평가법의 두 가지 방법으로 측정하였다. 본 연구의 결과는 다음과 같다; 1. 미세경도는 시편 상면이 하면에 비해 단단한 양태를 보였으며 상, 하면에 관계없이 혼합형 복합레진인 국산 DenFil이 미세입자형 복합레진인 Esthetx에 비해 높은 경도치를 보였다. 2. 모든 미세 경도 실험에서 너무 낮은 광도(50mW/$\textrm{cm}^2$, 100mW/$\textrm{cm}^2$)로 중합한 군에서는 대조군에 비해 유의하게 낮은 미세 경도를 보였다(p<0.05). 3. 상면의 경우, DenFil은 중합시간과 관계없이 200mW/$\textrm{cm}^2$ 이상의 광도에서 대조군(600mW/$\textrm{cm}^2$ 광도로 40초간 중합)과 유의차 없는 미세경도치를 보였으나, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 4. 하면의 경우 DenFil은 300mW/$\textrm{cm}^2$ 이상의 광도로, Esthet X는 200mW/$\textrm{cm}^2$ 이상의 광도로 각기 40초 동안 중합한 군에서만 대조군과 유의차 없는 미세경도치를 보였다. 5. 법랑질 변연부에서는 색소 침투가 전혀 없었으나 상아질 변연부에서는 정도의 차이는 있었지만 모든 시편에서 색소 침투를 보였다. 6. 통계적 유의차는 없었지만 저광도에서 우수한 미세누출도를 보였으며 색소 침투법과 최대 이개도 평가법간에는 상관성이 매우 낮았다 (p=0.801).

  • PDF

The Esthetic Impact of Extraction and Nonextraction Treatments on Korean People (발치, 비발치를 동반한 교정치료 전후의 안모의 변화에 관한 인지도)

  • Lee, Se-Hyeong;Chung, Dong-Hwa;Cha, Kyung-Suk;Lee, Jin-Woo;Lee, Sang-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • The concept of extraction in orthodontic treatment has been changed many times. Even today, criteria of extraction or nonextraction is still changing. In this study, changes depending on the evaluator's perception of treatment outcomes were compared in both extraction and nonextraction cases. In this study, premolar extracted 59 patients and nonextracted 60 patients, totally 119 patients who finished orthodontic treatment in Dankook University Dental Hospital orthodontic clinic were enrolled. Evaluation sections made up of specialists and laypersons assessed soft tissue traced from lateral cephalometric radiographs with visual analogue scale before and after the treatment. And the results were statistically analyzed. Thus, the conclusions drawn are as follows: 1. Average score is 5.76 in extraction, which is larger than 5.28 of nonextraction case. Improvement of facial profile was more favorably accepted in extraction case. 2. 5.875 in the group of specialists were higher evaluation than 5.165 in the group of layperson. 3. Specialists gave significantly higher ratings in the extraction than nonextraction. 4. A higher rating in extraction case of the layperson group has no significant difference with nonextraction case. 5. Nonextraction patients were given higher ratings from specialist group. 6. A higher rating of specialist group in extraction case has no significant difference with layperson group.

A STUDY ON THE BOND OF AESTHETIC RESTORATIVE MATERIALS TO FLUORIDE TREATED ROOT DENTIN (불소처리된 치근상아질에 대한 심미수복재의 결합에 관한 연구)

  • Tak, Heung-Soo;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Choi, Ki-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.197-212
    • /
    • 1998
  • The purpose of this study was to evaluate the effects of fluoride application on the aspect of shear bond strength of three aesthetic restorative materials to dentin. One light-cured composite resin(Palfique Esterite) and two light-cured glass ionomer cements(Fuji II LC and Compoglass)were used in this study. 120 permanent molars were used for this study. The teeth were extracted due to the origin of periodontal disease. The crowns of all teeth were removed, and the remaining roots were embedded in epoxy resin. The mesial or distal surfaces of roots were ground flat to expose dentin and polished on wet 320-, 400-, and 600 grit SIC papers for a total of 120 prepared flat root dentin surfaces. The prepared samples were divided into six groups. Group 1, 3, and 5 were control groups and group 2, 4, and 6 were experimental groups. Sixty samples for experimental groups were treated with 2% NaF solution for 5 minutes. Group 1 and 2 were bonded with Plafique Esterite, group 3 and 4 were bonded with Fuji II LC, and group 5 and 6 were bonded with Compoglass. After 24 hours water storage at $37{\pm}1^{\circ}C$, all samples were subjected to a shear to fracture with Instron universal testing machine(No.4467) at 1.0 mm/min displacement rate. Dentin surfaces treated with each conditioners before bonding and interfacial layers between dentin and aesthetic restorative materials were observed under Scanning Electron Microscope(Hitachi S-2300) at 20Kvp. The data were evaluated statistically at the 95% confidence level with ANOVA test. The result were as follows; 1. Among the control groups, group 1 showed strongest bond strength and group 3 showed weakest. 2. Among the experimental groups, group 2 showed strongest bond strength and group 6 showed weakest. 3. Statistical analysis of the data showed that pretreatment of dentin with 2% NaF solution significantly decreased the bond strength of three aesthetic restorative materials to dentin(P<0.05). 4. SEM findings of fluoride treated dentin surfaces (2, 4, 6 group) demonstrated dentin surfaces covered with fluoridated reaction products. 5. Except group 4 and 6, resin tags were formed in all groups.

  • PDF

A STUDY ON THE BONDING OF ESTHETIC RESTORATIVE MATERIALS TO BLEACHED BOVINE ENAMEL (치아표백후의 법랑질에 대한 심미성 수복재의 결합강도 변화에 관한 연구)

  • Rew, Kyung-Hee;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.183-196
    • /
    • 1998
  • The purpose of this study was to determine the effect of bleaching technique on the shear bond strength of esthetic restorative materials to bovine enamel. The bleaching agent was used 35% $H_2O_2$(Hi-Lite, Shofu, U.S.A.). Experimental groups were divided into two divisions as group A and B. Experimental A groups for the effect of number of bleaching were as follows ; Group Al : no bleaching Group A2 : bleaching 1 time ( for 5 minutes ) Group A3 : bleaching 3 times ( each for 5 minutes ) Group A4 : bleaching 6 times ( each for 5 minutes ) Group A5 : bleaching 9 times ( each for 5 minutes ) Experimental B groups for the effect of storage period in artificial saliva were as follows ; Group B1 : not stored in artificial saliva after bleaching Group B2 : stored in artificial saliva for 1 day after bleaching Group B3 : stored in artificial saliva for 1 week after bleaching Group B4 : stored in artificial saliva for 2 weeks after bleaching Group B5 : stored in artificial saliva for 4 weeks after bleaching Composite resin and glass ionomer cement were bonded to all specimens, and the shear bond strength between enamel and r~storative material were measured in Instron Universal Testing Machine(Instron, 4467, U.S.A,), Additionally, the bleached enamel specimens were examed after etching with 37.4% $H_3PO_4$ for 1 min under SEM(S-2300, Hitachi Co., Japan) to observe the effect of bleaching procedure on enamel surface morphology. The result were as follows ; 1. In SEM findings, bleached bovine enamel was found to be superficially rough. 2. In bleached bovine enamel, the effect of acid etching was reduced with the increase of number of bleaching. 3. The mean shear bond strength of composite resin and glass ionomer cement to bleached enamel surface tended to be lower than those to non-bleached enamel surface. 4. With the increase of number of bleaching, the shear bond strength of composite resin and glass ionomer cement to bleached enamel were progressively decreased. 5. Increasing the, storage period in artificial saliva after bleaching, the shear bond strength of composite resin and glass ionomer cement to bleached enamel were progressively increased. 6. The mean shear bond strength of glass ionomer cement to bleached bovine enamel tended to be clearly lower than that of composite resin.

  • PDF