• Title/Summary/Keyword: 치과 보철물 디자인

Search Result 45, Processing Time 0.026 seconds

Effect of machining precision of single ceramic restorations on the marginal and internal fit (단일 도재 수복물의 가공 정밀도가 변연 및 내면 적합도에 미치는 영향)

  • Son, Keunbada;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the machining precision and the marginal and internal fit of single restorations fabricated with three types of lithium disilicate ceramic blocks and to evaluate the correlation. Materials and methods: Single restorations were designed using a CAD software program. The crown designed model file was extracted from the CAD software program. Three types of lithium disilicate blocks (Rosetta; HASS, IPS e.max CAD; Ivoclar vivadent, VITA Suprinity; VITA) were milled using a milling machine. For the fabrication of the crown scanned model file, the intaglio surface of the restoration was digitized using a contact scanner. Then, using the three-dimensional inspection software (Geomagic control X; 3D Systems), the process of the overlap of the crown designed model and the scanned model and 3-dimensional analysis was conducted. In addition, the marginal and internal fit of the crowns was evaluated by a silicone replication method. The difference among three types of single ceramic crown was analyzed using a Kruskal-Wallis H test, and Spearman correlation analysis was performed to analyze the correlation between machining precision and fitness (α=.05). Results: There was a significant difference in the machining precision and the marginal and internal fit according to the type of ceramic block (P<.001). In addition, the machining precision and the marginal and internal fit were positively correlated (P<.001). Conclusion: The marginal fit of crowns fabricated according to the types of ceramic blocks was within the clinically acceptable range (< 120 ㎛), so it can be regarded as appropriate machining precision applicable to all clinical as aspects in terms of the marginal fit.

3D printed surveyed restoration and metal framework in removable dentures: A case report (3D 프린팅 된 서베이드 금관과 금속 프레임워크를 이용한 양악 가철성 의치 수복 증례)

  • Song Yi Park;Sang-Won Park;Chan Park;Woohyung Jang;Kwi-Dug Yun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.153-159
    • /
    • 2023
  • Computer-aided design-computer-aided manufacturing technology has been widely used in the manufacture of fixed prostheses including implants, but in the case of removable dentures, the analog method is still being used due to the errors such as a lack of fusion and over-fusion in selective laser meting process. With the recent development of CAD software, virtual surveying and framework design are made possible, and the designed file can be manufactured by milling or 3D printing. It replace the analog method of waxing and denture curing process and also can reduce the production time and cost. Therefore, this case is reported because good clinical results were obtained by digitally surveying on CAD software to produce a surveyed metal restoration and framework on maxillary and mandibular removable dentures.

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.

Implant assisted removable partial denture with implant surveyed crown: A 20-month follow-up case report (단일 임플란트 서베이드 크라운을 이용한 하악 임플란트 융합 국소의치: 20 개월 경과 관찰 증례 보고)

  • Roh, Kyoung-Woo;Jeon, Young-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.323-329
    • /
    • 2018
  • Traditional options for posterior edentulous treatment include removable partial dentures and implant fixed prostheses. Recently, the concept of implant assisted removable partial denture, in which two treatments are fused, has been introduced in consideration of systemic health and patient's needs, costs, residual alveolar bone status and so on. Implant assisted removable partial denture has the advantage of increasing the retention and stability of the denture and improving its esthetics in cases of large bone defects or biomechanical disadvantages. In addition, it is possible to strategically place the implants in a site where the alveolar bone is relatively sufficient, thereby overcome the limit of the conventional removable partial denture design as well as reducing the burden on a wide range of implant surgery. Cost reduction is also expected. In this case, the patient was treated by placing the implant in both premolar sites of the mandible and fabricating the distal extension removable partial denture with the implant fixed prosthesis as an abutment. After delivering the definitive prosthesis, the patient showed satisfaction with the masticatory function and esthetics. and has been regularly followed-up for more than one year. The following 20-months follow-up case report describes the design of an implant-assisted-removable partial denture (IARPD) in which two cementretained implant crowns used to provide support and stability.

Full mouth prosthetic rehabilitation based on systemic analysis, diagnosis and treatment plan: a case report (체계적 분석, 진단, 치료 계획을 통한 전악 보철 재건 증례)

  • Kwon, Sooyeon;Paek, Janghyun;Pae, Ahran;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.332-338
    • /
    • 2013
  • Data collection including checking the problem list and analyzing the etiology cannot be overemphasized in full mouth rehabilitation cases. It is well reported that favorable prognosis of prosthodontic treatment depends on accurate diagnosis. Seventy seven year old female patient presented with chief complaints of chewing pain on maxillary and mandibular left premolars and unesthetic existing prosthesis. Clinical evaluation, radiographic examination and cast analysis were performed to gather comprehensive data and problem lists. Treatment planning was based on collected data and related articles. Abutment evaluation, prognosis depending on various types of prosthesis, and maintenance were considered as well. Occlusal vertical dimension was increased to solve esthetic dissatisfaction and insufficient interocclusal space. Patient adaptation was verified with provisional restorations followed by diagnostic wax up. Function, esthetics and occlusal stability were verified during 8 week follow-up period. Prosthodontic reconstruction based on systemic analysis, diagnosis, and treatment plan led to satisfactory result after delivery of definitive prosthesis.

Retreatment of fractured implant overdenture due to long-term maintenance failure (장기간의 유지관리 실패로 인해 파절된 임플란트 피개의치 재수복 증례)

  • Kim, Minjee;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.235-242
    • /
    • 2018
  • Periodontal and prosthodontic maintenance of implant overdenture is a very important factor for the long term success of the prosthesis and implants. Failure of maintenance can lead to prosthetic failure due to peri-implant bone loss and fracture and wear of the prosthesis or components. In this case, the existing gold milled bars were reconstructed with cobalt chrome milled bar in a manner that does not interfere with the external shape for the retreatment of fractured implant overdenture by maintenance failure. Two implants of mandible were selected strategically and the CM LOC attachments were connected to the two implants, and implant overdentures were fabricated. As a result, prosthesis with a functional and esthetic design that facilitates good hygiene management of the patient was delivered, which is advantageous for long term maintenance, and regular check-ups were scheduled for proper maintenance.

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.

Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc (단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교)

  • Song, Jun-Beom;Lee, Jonghyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • Purpose. The purpose of present study was to evaluate the effect of changing structural stability of wax disc on the fit of prosthesis when the milling proceeded in order. Materials and methods. Prepared maxillary left first molar was used to fabricate a Ni-Cr alloy reference model. This was scanned to design crown and then wax pattern was milled, invested and cast to fabricate prosthesis. The wax patterns located in a row centrally within a single wax disc were set into a total of five groups ranging from WM1 group that was first milled to WM5 group that was last milled and the number of each group was set as 10. Silicone replica technique was used to measure the marginal gap, axial internal gap, line angle internal gap, occlusal internal gap. Data was evaluated with one-way ANOVA with significance level set at α = .05 and then Tukey HSD test was conducted for post analysis. Results. Marginal gap measured in each group, it was 40.41 ± 2.15 ㎛ in WM1 group, 40.44 ± 2.23 ㎛ in WM2 group, 39.96 ± 2.25 ㎛ in WM3 group, 39.96 ± 2.48 ㎛ in WM4 group, and 40.57 ± 2.53 ㎛ in WM5 group. No significant difference was found between groups. The significant difference between the groups was also not found in the axial internal gap, line angle internal gap, and occlusal internal gap. Conclusion. Internal and marginal fit of single crown to the sequential order of milling processing in the single machinable wax disc did not seem to be affected by the sequence.

Implant assisted removable partial denture using bilateral single implant-supported surveyed crown: a case report (양측성 단일 임플란트 지지 서베이드 크라운을 이용한 하악 임플 란트 보조 국소의치 수복 증례)

  • Seojune Choi;Hong Seok Moon;Jaeyoung Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Implant assisted removable partial denture (IARPD) has been practiced in various forms for a long time, and among them, implant surveyed crown RPD is gaining predictability as well as being considered as a treatment option for patients with anatomical and financial disadvantages. The position of implant could be divided as posterior placement or anterior placement according to the purpose of the treatment and should be planned in consider to the alveolar ridge of patient, anticipated prognosis of remaining teeth, and opposing dentition. This case report describes a treatment for mandibular Kennedy class I partial edentulous patient with two implant-supported surveyed crown and implant assisted removable partial denture. Given the difficulty of posterior placement in this patient and the prognosis of the residual teeth, the plan was to place two implants in close proximity to the residual teeth, which were placed in the planned position, angle, and depth using guided surgery. The process of fabricating the fixed prosthesis was carried out in parallel with the maxillary edentulous tooth arrangement process to increase predictability, and when fabricating the localized tooth, the implant was designed in a form that allows the patient to perform functional movements by preventing excessive loading as the last supporting tooth, and was fabricated through a secondary impression process. Each treatment procedure was proceeded as planned, with aesthetically and functionally satisfactory results for both patient and operator.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.