• Title/Summary/Keyword: 치과임플란트 소재

Search Result 22, Processing Time 0.029 seconds

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.

Problems of Metallic Dental Instruments for Dental Use (치과에서 사용되는 금속치과기구의 임상적용시 문제)

  • 최한철
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.15-15
    • /
    • 2003
  • 치과재료에 사용되는 금속재료는 주로 스테인리스강, 타이타늄, Ni-Ti, Co-Cr등과 같은 특수합금이 주로 사용되고 있다. 이들 재료는 치과 보철물과 교정재료 및 충전재료로 주로 사용되고 있으며 그 외 치과에서 사용되는 기기나 기구에도 많이 활용되고 있다. 특히 치과 보철물을 사용하여 치료를 원하는 환자가 최근에 급격히 증가하면서 임플란트 고정체와 나사 등을 이용한 치료법의 연구와 개발이 필요하게 되어 세계적으로 연구와 투자가 활발히 진행되고 있다. 그러나 재료의 설계나 합금의 설계 및 제품의 설계상의 문제로 인하여 생체조직과 결합하는데 많은 문제점이 임상적으로 발생되고 있다. 즉 임플란트 표면의 생체적합성부여, 고정체와의 결합시 파절이나 풀림현상, 골에 고정체로 사용하는 나사의 강도와 내마모성문제 등이 개선되어야 할 문제점으로 남아있다. 또한 총의치에 사용되는 자석 어태치먼트의erosion-corrosion문제, 교정선의 탄성 과 마모저항문제 등은 앞으로 계속적인 연구를 행하여야할 과제로 남아있다. 또한 국소의치에서 사용되는 frame은 정밀주조법을 통하여 제조하며 주조상의 결함 등으로 인한 클라스프의 파절 문제점이 발생되고 있다. 따라서 본 연구에서는 치과재료로 사용되는 임플란트 고정체, 나사, 교정용 선등의 문제점을 고찰하고, 지금까지 이루어진 연구를 중심으로 최적의 개선 조건을 찾고자하였다. 최근첨단소재 및 금속재료를 사용하여 치과재료 합금을 설계할 수 있는 연구가 활발히 진행된다면 수입에 의존하고 있는 고가의 치과재료를 값이 싼 고성능의 제품으로 대체할 수 있는 효과가 클 것으로 생각된다.>$\rho$$\sub$0/=1.8 %. As t$\sub$Co/ increases, a transition from the regime of co-existence of superparamagnetic and ferromagnetic behaviors to ferromagnetic behavior was observed. Tunneling barrier called "decay length for tunneling" for the films having the thickness of Co layer from 1.4 to 1.6 nm was measured to be ranged from 0.004 to 0.021 ${\AA}$$\^$-1/.문에 기업간 관계를 연구하는 측면에서는 탐험적 연구성격이 강하다. 더 나아가 본 산업의 주된 연구가 질적이고 기업내부만을 연구했던 것에 비교하면 시초적이라고 할 수 있다. 또한 관계마케팅, CRM 등의 이론적 배경이 되고 있는 신뢰와 결속의 중요성이 재확인하는 결과도 의의라고 할 수 있다. 그리고 신뢰는 양사 간의 상호관계에서 조성될 수 있는 특성을 가진 반면, 결속은 계약관계 초기단계에서 성문화하고 규정화 할 수 있는 변수의 성격이 강하다고 할 수가 있다. 본 연구는 복잡한 기업간 관계를 지나치게 협력적 측면에서만 규명했기 때문에 많은 측면을 간과할 가능성이 있다. 또한 방법론적으로 일방향의 시각만을 고려했고, 횡단적 조사를 통하고 국내의 한 서비스제공업체와 관련이 있는 컨텐츠 공급파트너

  • PDF

A Study on the Drilling Characteristics for Implant Procedure Drill (임플란트 시술용 드릴의 가공 성능 평가에 관한 연구)

  • Lee, Sang-Min;Chae, Seung-Su;Lee, Jae-Kun;Choi, Hwan;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.49-54
    • /
    • 2014
  • Skull Melted 3.2YSZ has good physical properties and does not undergo low temperature degradation. Due to these excellent physical and mechanical properties, Skull Melted 3.2YSZ has been studied for use in dental implants. In this study, a ø2.2mm Initial Twist Drill was made using Skull Melted 3.2YSZ; the drilling characteristics were compared with those of the traditional SUS420J drill. The experimental results indicate that the Skull Melted 3.2YSZ drill requires similar thrust forces and has a slightly higher temperature.

Structural equation modeling for association between patient satisfaction and quality of life after implant surgery (임플란트 만족도와 삶의 질 간의 관련성에 대한 구조방정식모델 분석)

  • Chung, Sun-Young;Cho, Jin-Hyun;Lee, Kyu-Bok;Choi, Youn-Hee;Song, Keun-Bae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.291-299
    • /
    • 2011
  • Purpose: This study was designed to measure patient satisfaction and oral health-related quality of life and to assess an association between patients' satisfaction and oral health-related quality of life after implant surgery by using structural equation modeling. Materials and methods: A total of 257 participants who visited 6 dental clinics located in Daegu city for the purpose of implant treatment participated in this study. Six months after completion of implant surgery, the patients' satisfaction and oral health-related quality of life were surveyed. The effect of factors associated with patients' satisfaction such as functions and aesthetics, maintenance and cost on oral health-related quality of life after implant surgery was analyzed using AMOS 4.0. Results: Oral health-related quality of life was improved in all dimensions of OHIP-14 after implant surgery. Functions and aesthetics as well as maintenance had a significant effect on oral health-related quality of life (P<.05), while cost was not a critical factor influencing oral health-related quality of life. Conclusion: High satisfaction with functional aspects and maintenance aspects significantly affected good quality of life. The result of this study supported the fact that education and management for patients after implant therapy were positively related to good quality of life based on a theoretical model.

Dental application of Polyaryletherketone for fixed dental prostheses (자연치와 임플란트 고정성보철에서 PAEK소재의 적용)

  • Lee, Du-Hyeong
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.152-158
    • /
    • 2018
  • Polyaryletherketone (PAEK) is recently introduced in dentistry. The polymer has superior mechanical and chemical properties compared to previous dental materials. PAEK has been explored for lots of applications for clinical dentistry. The prostheses can be made by the injection molding or milling techniques. Recent studies focus on improving the bioactivity of PAEK and expanding the application. The purpose of this article is to introduce the basic features, chemical structure and various clinical applications in fixed dental prostheses. Further research and clinical trials will be needed to confirm the usability of PAEK in the routine practice.

  • PDF

The Effect of Discrimination on Reutilization Intention in Dental Care Service (치과서비스에 대한 차별감이 재이용의사에 미치는 영향)

  • Choi, Kyu-young;Lee, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.111-119
    • /
    • 2017
  • The purpose of this study was to examine the effect of discrimination on thereutilization intentionfor dental services among patients who visited the dental clinic. The questionnaire was administered to 432 patients aged 20 years or older who visited Dental Clinic in J city, Chungcheongbuk-do. Day to March 31, 2015, and the following results were obtained. The important variables that affected the reutilization intention were quality of medics, kindness, hospital image, convenience, service value and discrimination of dental care service. These variables explained 78.2% of the aggregate. Thehigher the quality of service value, medics, environment facilities, convenience, kindness, and hospital image, the more significant was the relevance with reutilization intention. As well as high-educated respondents, ones with monthly household income amounted to 4 million won, group of white-collar job, people who visited for implant treatment and ones by introduction of acquaintances. Therefore the dental care service providers are required to take effortsto recognize the discrimination and to reduce it through good quality of dental care service.

Patients' Functional Satisfaction of Dental Implant Treatment (임플란트 시술에 대한 환자의 기능별 만족도)

  • Lee, Myeong-Ju;Han, Gyeong-Soon;Choi, Jun-Seon
    • Journal of dental hygiene science
    • /
    • v.8 no.2
    • /
    • pp.97-101
    • /
    • 2008
  • This study was aimed to provide basic data which are fairly useful to improve satisfaction level of patients by analyzing factors related to each functional satisfactions of dental implant treatment. The subjects of this study were 120 patients who received implant treatment and analyzed with t-test, one-way ANOVA and pearson's correlation. The results of this study were as follows. 1. Differences of each functional satisfaction according to general characteristics was not reveal statistically significant. 2. A group to got periodic scaling and tooth brushed four or more times a day showed the highest satisfaction of social and esthetic function(p < .05). 3. A group to implantation in premolar area showed the highest satisfaction of masticatory function and a group to implantation in incisor to be high in satisfaction of social and esthetic function, but the differences were not statistically significant 4. A group to got implant treatment at a dental hospital showed the highest satisfaction of both social and esthetic function, and at a general hospital were found lowest(p < .05). 5. Masticatory function, social function, esthetic function, and overall satisfaction were found to be in a positive correlations, and especially, the correlation coefficient between the overall satisfaction and social function was found to be highest(p < .01).

  • PDF

Stress Analysis and Fatigue Failure of Prefabricated and Customized Abutments of Dental Implants (치과 임플란트에서 기성 지대주와 맞춤형 지대주의 응력분석 및 피로파절에 관한 연구)

  • Kim, Hee-Eun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.209-223
    • /
    • 2013
  • This study was to evaluate the stress distributions of prefabricated, customized abutments and fixtures according to their material and shape by three-dimensional finite element analysis. And to investigate the fatigue life and fracture characteristics. Mandibular models were fabricated by reconstruction of the CT scan of patients with normal occlusion. A total of six finite element models were designed, a load of 100 N was applied on the buccal cusps vertically, and 30 degree obliquely. 10 specimens each were fabricated for the more clinically widely used 4 type abutments and were loaded according to ISO 14801. Differences in stress distribution patterns were not found according to the materials of the abutments and fixtures. But a slight difference in the stress level was detected. Customized abutment groups showed lower crown stress levels. One-piece zirconia implant showed the lowest bone stress levels. In the fatigue test, highest values were measured in group 7. Prefabricated abutments showed less variation of fatigue life (P<0.05). Use of customized abutments can improve the fracture resistance of restorations. Especially, use of customized zirconia abutments reinforced by titanium screw connecting parts is recommended.

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis (티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.