• 제목/요약/키워드: 치과용임플란트

검색결과 210건 처리시간 0.024초

치과용 임플란트 주위 열손 결손에 대한 차폐막의 유도조직재생에 관한 연구 (Guided tissue regeneration using barrier membranes on the dehiscence defects adjacent to the dental implants)

  • 이동호;최상묵
    • Journal of Periodontal and Implant Science
    • /
    • 제25권2호
    • /
    • pp.301-320
    • /
    • 1995
  • The purpose of this study was to evaluate a new biodegradable membrane - atelocollagen as a guided tissue regeneration barrier on the dehiscence defects adjacent to the dental implants. 3 beagle dogs were selected for this study and all the mandibular premolars($P_1,P_2,P_3&P_4$) were extracted. Twelve weeks after the extraction, the edentulous ridges were formed to be placed the titanium plasma-sprayed IMZ implants. Four implant osteotomies were performed on each side of the mandible. The osteotomies were placed facially in the edentulous ridges to approximate an actual dehiscence defect as closely as possible, The standardized dehiscence defects were created 3 mm in width and 4 mm in height by osteotomy. A total 24 implants were placed. e-PTFE, ateloco11agen and $Collatape^{(R)}$ were placed to cover the defects and the one defect served as a control, not covered any membrane. By random selection, three dogs were sacrificed at 2 weeks, 4weeks and 8 weeks after fixation with 3% glutaraldehyde. A week before sacrificing, 8-week dog was infused intravenously with oxy-tetracycline 30mg/kg. The left mandibular blocks were used for full decalcified histologic preparation and the right mandibular blocks were selected for undeca1cified preparation, At 2 weeks, the regenerated bone of e-PTFE and atelocollagen groups appeared to be more dense than other groups and the percentage of bone defect fill was highest for e-PTFE and follwed by ateloco1lagen group. However, the $Collatape^{(R)}$ and control groups showed a little new bone formation. $Collatape^{(R)}$ was almost degraded within 2 weeks. At 4 weeks, the regenerated new bone were much greater and denser than at 2 weeks for e-PTFE and ateloco11agen group. Although a part of atelocollagen bagan to be degraded at the margin and surrounded by foreign body giant cells related to foreign body reaction, it was generally intact and the regenerated new bone was shown much more than at 2 weeks. The amount of new bone in $Collatape^{(R)}$ and control groups at 4 weeks were similar to that of 2 weeks group. At 8 weeks, the regenerated bone was matured and observed along the implant fixture. Direct new bone formation and calcium deposits beneath the e-PTFE were observed. No further bone growth was seen in the $Collatape^{(R)}$ and control groups. In reflected fluoromicrcocopic observation, the osteogenic activity was pronounced between e-PTFE membrane and the old bone. High osteogenic activity was also observed in atelocol1agen group. This study suggested that the ateloco11agen as well as e-PTFE could be used for guided tissue regeneration on dehiscence defects adjacent to the dental implants. But the $Collatape^{(R)}$ was completely resorbed within 2 weeks and was not a suitable membrane for guided bone regeneration.

  • PDF

치과용 임플란트 적용을 위한 항균력을 가진 티타늄 표면의 평가 (An Evaluation of Antibacterial Titanium Surface For Dental Implant)

  • 강민경;문승균;김경남
    • 치위생과학회지
    • /
    • 제11권5호
    • /
    • pp.405-410
    • /
    • 2011
  • 본 연구의 목적은 표면 거칠기를 증가시키기 위하여 알루미나와 하이드록시아파타이트를 이용하여 각각 블라스팅 처리한 뒤 염화나트륨을 전해액 내에 섞어 양극산화 방법을 이용하여 염소가 함유된 표면을 만들고 항균력을 평가하는데 있다. 그리고 표면 특성과 항균력을 평가하여 다음과 같은 결과를 얻었다. 1. SEM 표면 관찰에서는 블라스팅 처리 후 양극산화한 결과 실험군 2와 3에서 연마처리한 실험군 1에 비해 거친 요철구조를 관찰할 수 있었다. 2. EDS 조성분석 결과 실험군 2에서는 칼슘, 인, 염소 성분과 더불어 알루미늄이 관찰된 반면, 실험군 3에서는 칼슘, 인과 염소 성분만을 관찰할 수 있었다. 3. 표면 거칠기 분석 결과 평균 표면 거칠기의 값이 실험군 2, 실험군 3, 실험군 1순으로 작았으며, 실험군 2와 3 간에는 유의한 차이가 없었다(p>0.05). 4. 항균력 평가 결과 실험군 2가 가장 적은 세균수를 보여 우수한 항균력을 보였으나 이는 실험군 3과 유의한 차이가 없었다(p>0.05). 알루미나와 하이드록시아파타이트를 이용하여 각각 블라스팅 처리한 뒤 염화나트륨을 전해액 내에 섞어 양극산화 방법을 이용하여 염소가 함유된 표면을 만들 수 있었으며, 그 결과 연마처리한 시편에 비해 높은 표면 거칠기와 우수한 항균력을 보였다. 그러나 그 재료의 효과와 안정성을 입증하기 위해서는 추가적인 in vitro와 in vivo 실험이 수행되어야겠다.

임플란트 주위염 치료시 치아회분말과 치과용 연석고의 혼합 매식의 골재생 효과 (A BIOLOGIC STUDY ON TOOTHASH - PLASTER OF PARIS MIXTURE WITH ABSORBABLE COLLAGEN MEMBRANE IN THE TREATMENT OF PERI-IMPLANT DEFECTS)

  • 최희연;김학균;김수관;문성용;김상렬;박광범;김용민;임성철;김은석;이정훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권2호
    • /
    • pp.142-149
    • /
    • 2008
  • The purpose of this study was to evaluate histomorphometrically a toothash - plaster of Paris mixture associated with collagen membrane ($Bio-Gide^{(R)}$), regarding new bone formation in the peri-implantitis defects in dogs. Three mandibular molars were removed from 1-year-old mongrel dogs. After 2 months of healing, 2 titanium implants with sandblasted with large grit and acid etched (SLA) surface were installed in each side of the mandible. Experimental peri-implantitis was induced with ligatures after successful osseointegration. Ligatures were removed after identification of bone defect beneath the level of 5th thread of fixture on radiographic image. The mucoperiosteal flaps were elevated and the contaminated fixtures were treated with chlorhexidine and saline. The bone defects were assigned to one of the following treatments: no guided bone regeneration (GBR) procedure (group 1), GBR with Bio-$Oss^{(R)}$ and Bio-$Gide^{(R)}$ (group 2), or GBR with toothash - plaster of Paris mixture (TPM) and Bio-$Gide^{(R)}$ (group 3). The dogs were sacrificed after 8 or 16 months. The mean percentages of new bone formation within the limits of the 5 most coronal threads were $17.83{\pm}10.69$ (8 weeks) and $20.13{\pm}13.65$ (16 weeks) in group 1, $34.25{\pm}13.32$ (8 weeks) and $36.33{\pm}14.21$ (16 weeks) in group 2, and $46.33{\pm}18.39$ (8 weeks) and $48.00{\pm}17.78$ (16 weeks) in group 3, respectively. The present study confirmed statistically considerable new bone formation within the threads in group 3 compared with group 1 at 8 and 16 weeks (P<0.05). Although, data analysis did not reveal significant differences between group 2 and 3, the latter showed better results during the period of 8 or 16 weeks. Our findings support the effectiveness of TPM as a GBR material in the treatment of peri-implantitis bone defect.

신경병증 통증 모델에서 Carbenoxolone과 P2x receptor 길항제의 효과 (Effects of Carbenoxolone and P2X recepter antagonist combined therapy on oral neuropathic pain in rat)

  • 구인영;문선정;가경환;박민경
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.123-128
    • /
    • 2016
  • 본 연구는 안면부 신경병증 통증 모델에서 간극결합을 분리하는 Carbenoxolone(CBX)과 P2X 수용체의 길항제(iso-PPADS)의 진통작용을 확인하고자 수행되었다. 실험동물은 Sprague-Dawley계 수컷 흰쥐(240~280g)를 사용하였으며, 안면부 신경병증 통증을 유발하기 위해 흰쥐의 하악 왼쪽 두 번째 어금니를 발거하고, 아랫 이틀신경의 손상을 유도하기 위해 소형 치과용 임플란트를 식립하였다. CBX를 복강으로 하루 2번 투여 했을 때, 25ug/kg에서 유의한 진통반응이 나타났다(p<0.05). iso-PPADS 역시 복강으로 하루 2번 투여 했을 때, 25ug/kg에서 유의한 진통반응이 나타났다(p<0.05). 두 약물의 각각의 효과가 나타나지 않은 저 농도에서 함께 투여하였을 때, CBX 1ug/kg, iso-PPADS 2.5ug/kg를 투여 시 유의한 진통 효과가 나타났다(p<0.05). 저 농도의 CBX를 이용한 간극결합의 차단과 저 농도의 P2X 수용체의 길항제를 함께 투여 시 구강 안면신경병증통증기전에서 통증을 억제하는 효과를 확인할 수 있었다. 이러한 결과를 통하여 CBX를 이용한 간극결합의 차단과 P2X 수용체의 길항제의 투여가 안면부 통증조절에 중요한 역할을 담당할 것으로 사료된다.

백서에 식립한 치과용 임플란트의 골유착에 흡연이 미치는 영향 (INFLUENCE OF CIGARETTE SMOKE INHALATION ON DENTAL IMPLANT OSSEOINTEGRATION IN THE RAT)

  • 김세호;김성민;김지혁;박영욱;박찬진;정기명;이석근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권4호
    • /
    • pp.291-299
    • /
    • 2005
  • Objectives : It is well known that cigarette smoking is harzardous to the osseointegration of dental implant, due to the impaired wound healing accompanied by reduced alveolar bone density. The aim of this study is to evaluate the influence of cigarette smoke on the implant osseointegration by the time factor consideration. Materials and methods : Twenty-four male Spraque-Dawley rats (8 weeks, weighting 200 to 250g) were used in this study. In the experimental group, 13 rats were exposed to cigarette smoke, 8 minutes per day during 6 weeks, and 12 rats in the control group were not exposed at any time. RBM (Resorbed blasting media) surfaced implant (diameter 3.3mm, length 5.0mm, AVANA Co., Korea) was placed in the right femur of each rat. Each implant with surrounding bone was prepared with microtome (cutting band 0.2mm$^{(R)}$, EXAKT Co., Germany) after 1 day, 2, 4, 8 and 12 weeks and stained with toluidine blue (1%). Another clinical investigation of each implant was also done at each evaluation time. Results : Clinical investigation around implant fixture showed that there were no significant differences between the control and experimental group. Microscopic observation around implant fixture showed that there were significant differences between the control and experimental group at the initial stage after implant fixture installation. Experimental group showed a decreased bone to implant contact within 4 weeks compared to control group, but showed similar characteristics after 4 weeks. Conclusion : Smoking inhalation effect on the dental implant showed the impaired wound healing by vasoconstriction and decreased intramedullary blood flow at initial stage of osseointegration. This experimental results can be clinically useful to the implant surgery of smoking patients.

상악동 중격;임플란트 수술 계획시 파노라마와 치과용 전산화 단충촬영 분석 (Maxillary sinus septum;panoramic radiographic and dental computed tomographic analyses in the planning of implant surgery)

  • 소현자;정동근;권진희;유소현;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.147-154
    • /
    • 2006
  • Surgical intervention in the posterior maxillary region requires detailed knowledge of maxillary sinus anatomy and the possible anatomical variations. This study evaluated the incidence, location of maxillary sinus septa by using radiographic (panoramic radiography and computed tomography) findings and comparison of panoramic radography with CT in antral anatomical variation. This study was based on data from 70 sinuses in partial dentate maxilla. The sample consisted of 61 patients(25 women and 36 men, with ages ranging between 19 and 77 years and a mean age of $49.4{\pm}11.3$ years) who were being treatment-planned to receive implant-supported restorations. First, the panoramic images were examined for the presence of antral septa by radiologist and examiner who don't know about CT findings. And incidence of antral septa was evaluated using an axial plane of CT image. The incidence of septa was compared between panoramic radiography and CT. The accuracy of the incidence was compared between radiologists and dentists. A total of 20 septa were found in 70 sinuses on CT image and the prevalence of one or more septa per sinus was found to be 28.6%. The assumed incidence of septa on panoramic radiography was $27.6%{\pm}2.2%$ in radiologist and $31.9%{\pm}5.8%$ in dentists. Erroneous diagnosis rate was 11.42% in radiologist and 15.96% in dentists. 40% of antral septa were located in the anterior(premolar) region, 30% of septa were located in the middle(first molar) and posterior(second molar) region separately. Prior to implant placement, it seems appropriate to consider panoramic radiography as a standard radiographic examination and periapical radiographs may be used to complete the findings in regions not sharply depicted in the panoramic radiograph. And cross-sectional imaging should be used in sites with severe bone loss and close proximity of the maxillary sinus.

선택적 레이저 용융 그리고 전통적인 주조 기술에 의해 제조된 Co-Cr 합금에 대한 전장용 세라믹의 전단 결합 강도 비교 (Comparison of Shear Bond Strength of Veneer Ceramics to Co-Cr Alloys Produced by Selective Laser Melting and Casting Technique)

  • 홍민호
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.434-439
    • /
    • 2020
  • 최근, 치과 산업에서 레이저를 열원으로 합금을 제조하는 선택적 레이저 용융법(Selective laser melting, SLM)이 소개되고 있다. 하지만 SLM으로 제작된 금속-세라믹 수복물에 대한 연구가 부족한 실정이다. 따라서 본 연구의 목적은 SLM 그리고 CAST(casting)에 의해 제조된 Co-Cr 합금의 금속-세라믹(metal-ceramic) 결합 강도(bond strength)를 평가하는 것이다. SLM 그리고 CAST 방법을 사용하여 Co-Cr 시편을 제조하고 세라믹을 소결하여 시료를 제작하였다. 연구의 실험은 표본 준비 및 분석을 통해 2020년 1월부터 6월까지 수행되었다. 금속-세라믹 결합 강도는 만능 시험기에 의해 측정되었다. 부착 세라믹의 면적분(The area fraction of adherence ceramic, AFAC)은 SEM/EDS로 시편의 Si 함량을 측정하였다. 금속-세라믹 결합 강도 및 AFAC 결과는 t-test를 사용하여 분석하였다(α = .05). SLM 그리고 CAST Co-Cr 합금 사이의 결합 강도에 대해서는 유의한 차이가 발견되지 않았다(P>.05). SLM은 CAST 그룹보다 많은 세라믹 부착성(ceramic adherence)을 나타냈다(P<.001). 세라믹과 합금의 결합 강도는 제조 방법엥 영향을 받지 않았다. 그러나 SLM은 더 우수한 세라믹 부착성을 보였다. 이는 향후 임플란트 상부 보철물 제작에도 SLM으로 제작한 합금이 사용 가능한 것을 시사한다. CAST 방식의 단점을 극복하고 시간과 비용을 절약할 수 있을 것으로 기대된다.

티타늄에 대한 레진과 도재의 결합 강도에 관한 연구 (The study on the shear bond strength of resin and porcelain to Titanium)

  • 박지만;김영순;전슬기;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.46-52
    • /
    • 2009
  • 연구목적: 최근 임플란트 상부보철물의 주재료로서 티타늄의 수요가 증가하고 있고, 급속도로 발전하고 있는 CAD/CAM (computer - aided design/computer-aided manufacturing) 기술이 접목되어 티타늄을 절삭하여 제작하는 방법이 주목을 받고 있으며 치과 임상에서 점점 그 영역이 넓어지고 있다. 다만, 하나의 티타늄괴를 절삭하여 만드는 방법의 특성상 기계적 유지력을 얻을 수 있는 비드 등을 형성할 수 없고, 통상적인 재료인 금 합금이나 도재용 합금 주조체에 비해 도재와의 결합력도 떨어지는 것이 보완해야 할 점으로 지적되고 있다. 이에 본 연구는 절삭형 티타늄을 이용한 보철물 제작에 많이 사용되고 있는 열중합 의치상 레진, 간접 복합 레진, 도재와 Grade II 순수 티타늄 사이의 결합 강도를 비교 평가해 보고자 하였다. 연구 재료 및 방법: 지름 9 mm, 높이 10 mm의 Grade II 순수 티타늄 원통형 시편 37개를 3군으로 나누어 각각 직경 7 mm, 높이 1 mm의 열중합 의치상 레진 (Lucitone 199, DENTSPLY Trubyte, York, USA), 간접 복합 레진 (Sinfony, 3M ESPE, Seefeld, Germany), 도재 (Triceram, Dentaurum, Ispringen, Germany)와 결합시켰다. 시편은 $5-55^{\circ}C$에서 1000회 열순환 처리 후, 범용 시험기 (Instron, Universal Testing Machine, Model 4465, USA)를 이용하여 1 mm/min의 속도로 하중을 가하여 전단결합강도를 측정하였다. 파절된 단면의 양상을 관찰하고 각 군별 파절양상을 조사하였다. 측정값은 one-way ANOVA와 Scheffe's multiple range test (${\alpha}=0.05$)로 분석하였다. 결과: 열중합 의치상 레진인 Lucitone 199 ($17.82{\pm}5.13\;MPa$)의 결합 강도가 가장 높았으며, 도재인 Triceram ($12.97{\pm}2.11\;MPa$), 복합레진인 Sinfony ($6.00{\pm}1.31\;MPa$) 순으로 감소하였다. Lucitone 199와 Sinfony 군의 파절 양상은 대부분이 부착성 파절인 데에 반해 Triceram 군에서는 복합성 파절이 많았다. 결론: CAD/CAM을 이용한 절삭형 티타늄 구조물 상방에 전장용 심미 재료로는 열중합형 의치상 레진이 가장 강한 결합 강도를 보인다. 기존의 주조체의 유지구 등에서 얻는 강도에 비해 약하고, 부착성 파절이 많은 점 등은 향후 이들 재료와 티타늄간의 결합력을 높이기 위한 보다 많은 연구가 이루어져야 할 것을 시사한다.

브레이징 온도 변화에 따른 $ZrO_2$와 Ti-6Al-4V의 접합 특성 (Brazing characteristics of $ZrO_2$ and Ti-6Al-4V brazed joints with increasing temperature)

  • 기세호;박상윤;허영구;정재필;김원중
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.169-175
    • /
    • 2012
  • 연구 목적: 온도 변화에 따른 $ZrO_2$와 Ti-6Al-4V의 접합 특성에 대해 알아보기 위하여 새로운 브레이징 합금을 제조하고, 브레이징 온도가 접합 특성에 미치는 영향에 대하여 조사하고자 하였다. 연구 재료 및 방법: 본 연구에서 사용된 시편으로는 실험용 $ZrO_2$ 모재(ZirBlank-PS, Acucera, Inc., Gyeonggi-do, Korea)는 소결 전의 블록형태($65mm{\times}36mm{\times}12mm(t)$)이며, 이를 잘라 사포(#2400)로 표면연마 후 소결하였다. 소결된 $ZrO_2$ 시편의 크기는 $3mm{\times}3mm{\times}3mm(t)$이다. Ti-6Al-4V 모재(Ti 6Al 4V ELI CG Bar, TMS, Washington, USA)는 직경 $10mm{\times}5mm(t)$를 사용하였다. 소결된 $ZrO_2$와 Ti-6Al-4V의 접합을 위하여 브레이징 합금을 제조하였다. 시편을 3군으로 나누어 A군은 $700^{\circ}C$에서, B군은 $750^{\circ}C$에서, C군은 $800^{\circ}C$에서 각각 브레이징 하였다. 브레이징 부의 두께와 결함율의 측정은 각 군당 하나의 시편으로 각 시편 당 5회씩 반복 측정하여 평균값을 취하였다. 결과: 브레이징 합금을 사용하여 진공 브레이징을 수행한 결과 $ZrO_2$ 와 Ti-6Al-4V 는 $700^{\circ}C-800^{\circ}C$에서 양호한 접합을 보였다. 브레이징 후 브레이징 온도 변화에 따른 브레이징 부의 두께 및 결함율의 변화는 SEM을 사용하여 측정하였다. 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가함에 따라 CuTi 금속간 화합물 층 및 Ti-Sn-Cu-Ag계 화합물 층의 두께는 각각 $4.5{\mu}m$에서 $10.3{\mu}m$로, $3.1{\mu}m$에서 $5.0{\mu}m$로 증가되었다. 또한 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가함에 따라 브레이징 접합계면의 결함율은 $ZrO_2$ 및 Ti-6Al-4V 계면에서 각각 25%에서 16.3%, 5%에서 1.5%로 감소되었다. 결론: 브레이징 온도가 $700^{\circ}C$에서 $800^{\circ}C$로 증가됨에 따라, 브레이징 접합계면의 결함율은 $ZrO_2$ 및 Ti-6Al-4V 계면에서 모두 감소되었다. 이는 결함부에서 $ZrO_2$와 활성원소인 Ti과의 반응이 충분히 일어나지 않아서 브레이징 합금이 $ZrO_2$에 웨팅되지 않은 것이 원인이라고 사료된다.

전기 방사 공정의 제조 변수를 이용한 TiO2 나노섬유의 직경 제어 (The control of TiO2 nanofiber diameters using fabrication variables in electrospinning method)

  • 윤한솔;김보성;김완태;나경한;이정우;양완희;박동철;최원열
    • 한국결정성장학회지
    • /
    • 제31권1호
    • /
    • pp.8-15
    • /
    • 2021
  • TiO2는 물리적, 화학적 안정성이 높고, 신체에 무해하여 태양전지, 치과용 임플란트 및 광촉매 같은 다양한 분야에서 사용되어 왔다. 비표면적이 큰 TiO2 나노섬유는 생체 친화성 제품에서 좋은 반응성과 공기 및 수질 정화시 우수한 광촉매 특성을 보여주었다. TiO2 나노섬유를 제조하기 위해 전기방사법을 사용하였으며, 제조 변수에 따른 직경 변화를 관찰하기 위해 precursor 성분 변수와 공정 변수로 구분하여 미세구조 변화를 분석하였다. Precursor 성분 변수로는 PVP(Polyvinylpyrrolidone) 및 TTIP(Titanium(IV) isopropoxide)의 농도를 선택하였고, 공정 변수로는 주입 속도와 인가 전압을 선택하였다. TiO2 나노섬유의 미세구조와 결정구조는 FE-SEM(Field emission scanning electron microscope)와 XRD(X-ray diffraction)을 이용하여 분석하였다. 450℃에서 3시간 열처리 공정을 통해, 평균 직경 약 0.27 ㎛에서 1.31 ㎛를 갖는 asspun TiO2 나노섬유가 0.22 ㎛에서부터 0.78 ㎛의 평균 직경을 갖는 anatase 상의 TiO2 나노섬유로 상전이 됨을 확인할 수 있었다. 평균 직경 0.22 ㎛의 anatase TiO2 나노섬유는 비 표면적 증대에 의한 광촉매 특성 향상을 기대할 수 있다. 또한 TiO2 나노섬유의 직경 변화를 위해서는 주입 속도 및 인가 전압과 같은 공정 변수보다는 PVP 농도 및 TTIP 농도와 같은 precursor 성분 변수를 제어하는 것이 더욱 효과적이었다.