• Title/Summary/Keyword: 치과교정학회

Search Result 2,942, Processing Time 0.025 seconds

Correlation between menton deviation and dental compensation in facial asymmetry using cone-beam CT (Cone-beam CT를 이용한 안면비대칭자에서 이부편위에 따른 치성보상의 양상분석)

  • Park, Soo-Byung;Park, Jeong-Heuy;Jung, Yun-Hoa;Jo, Bong-Hye;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.300-309
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the correlation between menton deviation and dental compensation in facial asymmetry. Methods: Tooth axis and distance of first molar and canine to the reference plane were investigated by cone-beam computerized tomography. The subjects consisted of 50 patients with asymmetric mandibles (male 21, female 29, mean age 24.3 years). Control groups were also assessed (male 11, female 9, mean age 25.6 years). Nine measurements (5 linear measurements and 4 angular measurements) were measured in order to evaluate the correlation between menton deviation and the linear and angular difference of first molar and canine in the deviated and none-deviated sides using the defined MPR images. The differences between deviated and non-deviated side, according to menton deviation, were statistically analyzed using stepwise multiple regression analysis. Results: From the result, Menton deviation was negatively correlated with mandibular first molar's angular measurement (${\Delta\angle}LM6$-Mn plane (dev.-ndev.)) and positively with maxillary fist molar's angular measurement (${\Delta\angle}UM6$-FH plane (dev.-ndev.)) (p < 0.01). Two angular measurements (${\Delta\angle}LM6$-Mn plane (dev.-ndev.), ${\Delta\angle}UM6$-FH plane (dev.-ndev.)) explained the variability in menton deviation with a significant $r^2$ value of 0.589. Conclusions: This study suggests that the tooth axis of upper and lower first molars leans towards the deviated side of Menton when there is mandibular asymmetry with Menton deviation.

Comparison of mandibular anterior alveolar bone thickness in different facial skeletal types (성인에서의 수평적, 수직적 안면 골격 형태에 따른 하악 전치부 치조골 두께의 비교)

  • Kim, Yoon-Soo;Cha, Jung-Yul;Yu, Hyung-Seog;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.40 no.5
    • /
    • pp.314-324
    • /
    • 2010
  • Objective: The purpose of this study was to determine differences of mandibular anterior alveolar bone thickness and symphysial cross sectional area in 9 different horizontal and vertical facial types. Methods: By using the initial cephalometric radiographs of 270 adult patients (male 135, female 135), the authors measured the buccolingual thickness of anterior alveolar bone on the basis of the root axis and symphysial cross sectional distance. Results: The high angle group showed significantly thinner buccolingual alveolar bone width except for the CEJ area and lingual alveolar bone width ($p$ < 0.05). The low angle group and Class I, II average group showed similar or significantly thicker alveolar bone width than the Class I average group ($p$ < 0.05). The Class III average group showed significantly thinner buccolingual and lingual alveolar bone width than Class I and II average groups ($p$ < 0.05). The Class III high angle group showed minimal alveolar bone width in all facial skeletal types. No significant difference was found in the symphysial cross sectional area of the different vertical facial skeletal types ($p$ > 0.05). Conclusions: The results of this study found that Class III high angle patients have thinner mandibular anterior alveolar bone thickness; therefore, more attention will be needed to determine the incisor position during orthodontic treatment for this group of patients.

Analysis of masseter muscle in facial asymmetry before and after orthognathic surgery using 3-dimensional computed tomography (3차원 전산화 단층 사진을 이용한 안면비대칭 환자의 악교정 수술 전, 후 교근 분석)

  • Seo, Seung-Ah;Baik, Hyoung-Seon;Hwang, Chung-Ju;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.18-27
    • /
    • 2009
  • Objective: The purpose of this study was to understand the differences in masseter muscle(MM) between the shifted and non-shifted sides in facial asymmetry patients, and the changes shown by MM after mandibular surgery. Methods: Pre- and post-operative CT scans were performed on 12 Class III patients with facial asymmetry who were treated by intraoral vertical ramus osteotomy and 10 subjects with normal occlusion. Using the V-works 4.0 program(Cybermed, Seoul, Korea), 3-dimensional images of the mandible, and MM were reconstructed, and evaluated. Results: In the asymmetry group, the MM angle between the shifted and non-shifted sides was only significantly different(p<0.05). Compared with normal occlusion, the asymmetry group showed a significantly smaller volume and maximum cross-sectional area in both sides of MM(p<0.05). After mandibular surgery, the angle of MM(p<0.01) and differences in angle between the shifted and non-shifted sides of MM(p<0.05) were significantly decreased. The thickness in the maximum cross-sectional area was significantly increased(p<0.01). After surgery, MM in facial asymmetry patients was similarly changed to those in the normal occlusion group except for widths. Conclusions: MM in facial asymmetry was definitely different from those in normal occlusion. However, this study suggests that MM changed symmetrically in conjunction with the mandible after proper mandibular surgery.

THE EXPRESSION OF NITRIC OXIDE SYNTHETASE IN THE EXPERIMENTAL TOOTH MOVEMENT IN RATS (백서의 실험적 치아이동시 Nitric Oxide Synthetase의 발현 양상)

  • Park, Dong-Kwon;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.107-120
    • /
    • 2001
  • Nitric oxide(NO) has been reported to be one of the mediators relating to bone remodelling. Nitric oxide is synthesized from L-arguinine by nitric oxide synthetase(NOS), which is largely divided Into two groups. One group which is composed of $NOS_1\;and\;NOS_3$, is dependent of calcium or calmodulin. The other consisted of $NOS_2$, which is independent of calcium or calmodulin. NOS is thought to be a possible intermediate affecting in the course of tooth movement. This study was designed to evaluate the expression of nitrous oxide synthetase(NOS) in periodontal tissue during the experimental movement of rat incisors, by LSAB(labelled streptavidine biotin) immunohistochemical staining for $NOS_2\;and\;NOS_3$. Twenty seven Sprague-Dawley rats were divided into a control group(3 rats), and 6 experimental groups(24 rats), to which 75g of force was applied, with helical springs across the maxillary incisors. Rats of experimental groups were sacrificed at 12 hours, 1, 4, 7, 14 and 28 days after force application, respectively. After that, the tissues of the control group and experimental groups were studied immunohistochemically. The results were as follows: 1. In control group, the expression of $NOS_3$ was rare in gingiva, dentin, periodontal ligament and alveolar bone, and was mild in the capillaries of pulp and intermaxillary suture. And the expression of $NOS_2$ showed similar pattern to that of $NOS_3$. 2. There were no differences in the expression of $NOS_2\;or\;NOS_3$ in dentin, gingiva, cementum, cementoblast and odontoblast, between control and experimental groups, regardless of the duration of the force application. 3. The expression of $NOS_3$ began to increase at 4 days and showed to the highest degree at 7 days after force application, in the apical region of pressure side of periodontal ligament in experimental groups. 4. The expression of $NOS_3$ in alveolar bone was rare until 7 days, after which it increased to mild degree at 14 days through 28 days in experimental group. But there was no difference between pressure and tension side of periodontal ligament. 5. The expression of $NOS_2$ in periodontal ligament was mild from 7 days after force application, regardless of the side of periodontium, which was generally more evident than that of $NOS_3$. 6. The expression of $NOS_2$ in alveolar bone increased to mild degree at 14 days after force application, and it was evident in osteoblasts, osteoclasts and osteocytes. And the expression of $NOS_2$ was little more stronger in the tension side than that of pressure side of alveolar bone.

  • PDF

STUDY ON THE GROWTH OF THE MANDIBLE USING WIDE OPEN LATERAL CEPHALOGRAM (Wide open lateral cephalogram을 이용한 하악골 성장에 관한 연구)

  • Moon, Sung-Uk;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.39-50
    • /
    • 2001
  • In proceeding with orthodontic treatment, the prediction for the shape, growth rate and growth direction of mandible plays a major role to set up the treatment plan and determine its period and prognosis. Various approaches being made so far have shown that the linear and angular measurement using lateral cephalograms are relatively accurate to estimate them. This study was purposed to find the shape of mandible more clearly by preventing the overlap of the Condyle head area which appears in lateral cephalogram, and to estimate its growth rate by comparing the growth quantity and ratio via lateral area measurement. This experimental was performed against 40 patients total, of which Class I of 14, Class II of 9 and Class III of 17 consist. Wide open lateral cephalograms of 40 patients were taken over average period of 4 Year 3 Months, then the linear and angular measurements were carried out with 11 itemized lists. Autocad Rl4 application program was utilized to draw their appearance, measure and compare their lateral area. As a result of study, conclusions were made as follows; 1. Mandibular body length (gonion-menton) tended to increase in order of CIII, CI and CII, and Mandibular body length of CIII group had a tendency to grow twice faster than that of CII group. 2. In lateral items such as Go-Me, A-Cd, B-Cp, E-F and G-H, CIII showed a significant increase on the year-average quantity and rate of the growth, and especially apparent difference was observed in CIII group rather than CII group. 3. For the 4 Year 3 Months period, the year-average growth quantity of lateral area of the mandible was $1.0cm^2$ for Class I, $0.8cm^2$ for Class II and $1.4cm^2$ for Class III, which corresponds to $11.9\%,\;11.8\%\;and\;20.3\%$ of growth ratio respectively. Thus, growth ratio almost 2 times more than other groups was observed in group CIII while growth ratio between group CI and CII has little difference. 4. Considering the results as above, it can be proposed that the difference in size of the mandible between groups is caused by the difference in the growth rate and growth quantity of the mandible, which generated in the middle of growth, rather than the difference in size of congenital Jaw-bone.

  • PDF

Shear bond strength of ceramic and resin brackets used with visible light-cured adhesives (도재 및 레진 브라켓에 대한 광중합 접착제의 전단 접착 강도)

  • Hwang, Yu-Sun;Row, Joon;Hwaang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.233-244
    • /
    • 1996
  • The purpose of this study was to compare the shear bond strength obtained from ceramic and plastic brackets bonded with various light-cured adhesives and to evaluate their debonded failure sites. Plastic brackets, Transcend 6000, Signature and Starflre TMB brackets were bonded with Orthobond, Light Bond and Transbond on one hundred forty extracted human premolar teeth as manufacturer's descriptions. After thermocycling the brackets were debonded with an Instron universal testing machine and the debonded bracket base surfaces were inspected under stereoscope to evaluate the failure sites. Also the shear bond strength and failure patterns with different curing time and with two different source of light were compared. The results were as follows. 1. There were no statistically significant differences among the mean shear bond strength of Orthobond, Light Bond and Transbond in a same bracket group except Plastic bracket group(p<0.05). 2. The mean shear bond strength of each adhesive with different bracket groups showed statistically significant differences. Stafire TMB showed the highest shear bond strenght among the brackets in this study, but there was no statistically singnificant difference with Transcend 6000 while there was statistically significant difference with Signature.(p<0.05) 3. The various bonding failure patterns were occurred among different bracket groups but most of failure sites were bracket base -adhesive interfaces. 4. There were no statistically significant differences in shear bond strength between the groups with curing time of 10 second and 20 second, and between the groups with two different sources of light as long as sufficient light intensity(above $400mWcm^2$) were provided(p<0.05). According to the result, it should be considered in clinical use of ceramic bracket with light-cured adhesives that the shear strengths of ceramic brackets were influenced by the retention from of bracket base as well as the composition of bracket and there was no difference in the shear bond strenght among various light-cured adhesives used in this study.

  • PDF

A Cephalometric study on tooth movement pattern of maxillary 6 anteriors with double keyhole loops (Double keyhole loop에 의한 상악 6전치의 후방견인시 치아이동양상에 관한 측모두부방사선계측학적 연구)

  • Kim, Hyun-Kyung;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.9-18
    • /
    • 2002
  • The present study hypothesized that the double keyhole looped archwire plays a positive role for the sake of translatory movement and/or controlled tipping of upper 6 anteriors, and secures anchorage control as well. The purposes of the study were to evaluate the changes in lateral cephalograms during orthodontic treatment with DKHLs and to compare the skeletal & dental changes before- & after-treatment. The materials of this study were lateral cephalograms of 20 adult patients with upper dentoalveolar protrusion both in class I and in class II Division1 malocclusion. Lateral cephalograms were taken before and after orthodontic treatment with upper 1st bicuspid extraction and DKHLs. The results were obtained as follows : 1. There were no statistically significant differences in skeletal measurement except SNB and PTFH between before- & after-treatment. The major changes were in dentoalveolar region. 2. After treatment, there were statistically significant decrease in dental measurement except interincisal angle. 3. Both upper & lower lip protrusion was decreased. 4. There were statistically differences in upper anterior crown horizontal & root vertical dimension(7.08 ${\pm}$ 2.14 mm, 2.38 ${\pm}$ 1.15 mm, p<0.01). 5. There were statistically differences in upper posterior dental(both crown & root) horizontal dimension(2.48 ${\pm}$ 0.99 mm, 2.05 ${\pm}$ 0.91 mm, p<0.01).

In vitro cytotoxicity of self-etching primers (자가 산부식 프라이머의 세포독성에 관한 실험적 연구)

  • Rhee, Chang-Hoon;Kim, In-Ryeon;Kim, Gyoo-Cheon;Kim, Seong-Sik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.422-433
    • /
    • 2006
  • Objective: Several ions and components are released from self-etching primers in the oral cavity. This may cause injury to the periodontal tissues throughout orthodontic treatment. The purpose of this study was to assess the cytotoxicity of self-etching primers to HGF-1, HaCaT, and RHEK cells. Method: Transbond XT Primer (3M Unitek, Monrovia, CA, USA), and self-etching primers, Clearfil SE Bond (Kuraray, Osaka, Japan), Transbond Plus SEP (3M Unitek, Monrovia, CA, USA), and Adper Prompt L-Pop (3M Unitek, Monrovia, CA, USA), were evaluated by MTT assay, and cellular changes were also observed. Results: In all cells after 72 hours with all primers, severe morphological changes such as atrophy and necrosis were observed. In the MTT assay using HGF-1, Clearfil SE Bond, Transbond XT Primer, Transbond Plus SEP, and Adper Prompt L-Pop were lined up in order of ascending cytotoxicity When using HaCaT, Clearfil SE Bond, Adper Prompt L-Pop, Transbond Plus SEP, and Transbond XT Primer were lined up in order of ascending cytotoxicity. When using RHEK, Clearfil SE Bond, Transbond XT Primer, Adper Prompt L-Pop, and Transbond Plus SEP were lined up in order of ascending cytotoxicity. Conclusion: The result of this study shows that care is needed because self-etching primers show cytotoxic properties similar to conventional primers.

Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images (CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석)

  • Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Objective: The result of finite element analysis depends on material properties, structural expression, density of element, and boundar or loading conditions. To represent proper elastic behavior, a finite element model was made using Hounsfield unit (HU) values in CT images. Methods: A 13 year 6 month old male was used as the subject. A 3 dimensional visualizing program, Mimics, was used to build a 3D object from the DICOM file which was acquired from the CT images. Model 1 was established by giving 24 material properties according to HU. Model 2 was constructed by the conventional method which provides 2 material properties. Protraction force of 500g was applied at a 45 degree downward angle from Frankfort horizontal (FH) plane. Results: Model 1 showed a more flexible response on the first premolar region which had more forward and downward movement of the maxillary anterior segment. Maxilla was bent on the sagittal plane and frontal plane. Model 2 revealed less movement in all directions. It moved downward on the anterior part and upward on the posterior part, which is clockwise rotation of the maxilla. Conclusion: These results signify that different outcomes of finite element analysis can occur according to the given material properties and it is recommended to use HU values for more accurate results.

The comparative study of three-dimensional cephalograms to actual models and conventional lateral cephalograms in linear and angular measurements (3차원 두부방사선규격사진의 정확성에 관한 연구 -실제 계측 및 측모 두부방사선 규격사진 계측과의 비교-)

  • BAE, Gi-Sun;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.129-140
    • /
    • 1997
  • Conventional cephalometrics have inherent errors because their evaluation is performed in two-dimension for threedimensional object. To compensate these errors, three-dimensional cephalograms - derivation of three-dimensional data from conventional lateral and postero-anterior cephalograms - were developed. In this study, the accuracy and precision of three dimensional cephalograms were determined by means of 10 linear and 12 angular measurements on 36 acrylic skull models and by the comparison of conventional lateral cephalograms. The results were as follows 1. Mean difference between three-dimensional cephalograms and actual models in linear measurements was $0.94{\pm}0.62mm$ and mean rate of magnification of three-dimensional cephalograms was $100.31{\pm}0.91%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in linear measurements(${\alpha}=0.1$). 2. Mean difference between conventional lateral cephalograms and actual models in linear measurements was $6.44{\pm}1.48mm$ and mean rate of magnification of lateral cephalograms was $106.99{\pm}1.45%$. There were statistically significant differences between lateral cephalograms and actual models in linear measurements(P<0.005). 3. Mean difference between three-dimensional cephalograms and actual models in angular measurements was $1.22{\pm}0.82^{\circ}$ and mean rate of magnification of three-dimensional cephalograms was $105.71{\pm}12.07%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in angular measurements(${\alpha}=0.1$). 4. Mean difference between conventional lateral cephalograms and actual models in angular measurements was $1.70{\pm}0.94^{\circ}$ and mean rate of magnification of lateral cephalograms was $106.35{\pm}15.70%$. There were no statistically significant differences between lateral cephalograms and actual models in angular measurements(${\alpha}=0.1$). There were similarity between three-dimensional and lateral cephalograms in angular measurements.

  • PDF