• Title/Summary/Keyword: 측정 정밀도 향상

Search Result 464, Processing Time 0.029 seconds

A Study on Improvement of Location Accuracy and Indoor location estimation system to minimize installation costs (실내 위치 추정 시스템의 설치비용 최소화와 위치 정확도 개선에 대한 연구)

  • Yeom, Jin-Young;Kang, Dong-Jo;Park, Hyun-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.5
    • /
    • pp.1083-1094
    • /
    • 2012
  • Commercialized location estimation System with high accuracy is widely used for various services. However, if the systems aren't completely installed in an indoor, location estimation accuracy tend to be very poor. In this paper, indoor location estimation algorithm to improve the accuracy of object location, by correcting the location information obtained from a system that does not fully install, is proposed. In this paper, UWB-based Ubisense system that provides high position accuracy in an indoor environment was utilized. In conclusion, this paper was able to improve the positioning accuracy, by correcting that information about the location of the measured object in position estimation system.

Development of a Signal Conditioner to Improve the Measurement Reliability of a Microseismic Monitoring System (미소진동 모니터링 시스템의 측정 신뢰도 향상을 위한 시그널 컨디셔너 개발)

  • Cheon, Dae-Sung;Han, Cheol-Min;Lee, Jang Baek
    • Tunnel and Underground Space
    • /
    • v.30 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Microseismic monitoring is utilized for the performance verification and safety management of the structure by detecting fine levels of damage. In order to construct a highly reliable microseismic monitoring system, the role of signal conditioner is critical. The signal conditioner helps with accurate data collection and precision control of the device, and performs additional functions such as signal conversion, linearization, and amplification. In this technical report, noise reduction signal conditioner suitable for mining sites was developed and reviewed for the purpose of implementing more precise monitoring by supplementing the previously developed microseismic monitoring system.

Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique (마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상)

  • Kim Dong-Iel;Kee Chang-Doo;Huh Yong-Hak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.54-63
    • /
    • 2006
  • Enhancement methods of sensitivity to in-plane strain measurement by micro-ESPI(Electronic Speckle Pattern Interferometry) technique were proposed using TiN and Au thin films. Micro-tensile strain over the micro-tensile specimens, prepared in micro-scale by those films, was measured by micro-tensile loading system and micro-ESPI system developed in this study. The subsequent measurement of in-plane tensile strain in the micro-sized specimens was introduced using the micro-ESPI technique, and the micro-tensile stress-strain curves for these films were determined. To enhance the sensitivity to measurement of in-plane tensile strain, algorithms of the phase estimation by using curve fitting of inter-fringe and the discrete Fourier Transform with object-induced dynamic phase shifting were developed. Using these two algorithms, the micro-tensile strain-stress curves were generated. It is shown that the algorithms for enhancement of the sensitivity suggested in this study make the sensitivity to measurement of the in-plane tensile strain increase.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

Design of MRI Spectrometer Using 1 Giga-FLOPS DSP (1-GFLOPS DSP를 이용한 자기공명영상 스펙트로미터 설계)

  • 김휴정;고광혁;이상철;정민영;장경섭;이동훈;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • Purpose : In order to overcome limitations in the existing conventional spectrometer, a new spectrometer with advanced functionalities is designed and implemented. Materials and Methods : We designed a spectrometer using the TMS320C6701 DSP capable of 1 giga floating point operations per second (GFLOPS). The spectrometer can generate continuously varying complicate gradient waveforms by real-time calculation, and select image plane interactively. The designed spectrometer is composed of two parts: one is DSP-based digital control part, and the other is analog part generating gradient and RF waveforms, and performing demodulation of the received RF signal. Each recover board can measure 4 channel FID signals simultaneously for parallel imaging, and provides fast reconstruction using the high speed DSP. Results : The developed spectrometer was installed on a 1.5 Tesla whole body MRI system, and performance was tested by various methods. The accurate phase control required in digital modulation and demodulation was tested, and multi-channel acquisition was examined with phase-array coil imaging. Superior image quality is obtained by the developed spectrometer compared to existing commercial spectrometer especially in the fast spin echo images. Conclusion : Interactive control of the selection planes and real-time generation of gradient waveforms are important functions required for advanced imaging such as spiral scan cardiac imaging. Multi-channel acquisition is also highly demanding for parallel imaging. In this paper a spectrometer having such functionalities is designed and developed using the TMS320C6701 DSP having 1 GFLOPS computational power. Accurate phase control was achieved by the digital modulation and demodulation techniques. Superior image qualities are obtained by the developed spectrometer for various imaging techniques including FSE, GE, and angiography compared to those obtained by the existing commercial spectrometer.

  • PDF

Analysis and Evaluation of Solar Radiation Resources and Reliability Enhancement on Insolation Data in Korea (한반도 태양에너지 자원의 분석.평가 및 데이터 신뢰성 향상 연구)

  • Jo, Dok-Ki;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.479-491
    • /
    • 2005
  • 지구환경문제와 에너지 수급관계를 감안할 때, 청정 및 대체에너지 연구개발은 불가피하며, 그 중에서도 태양에너지는 대표적인 대안의 하나로 인식된다. 따라서 태양에너지의 적극적인 활용에 필요한 기초자료의 마련은 필수적이다. 태양에너지의 이용 및 관련 절약 기술에 필요한 태양에너지 자원(기상)에 대한 기술자료는 최소한 30년간의 측정 자료를 필요로 한다. 이들 자료에는 시간별 수평면전 일사량, 법선면 직달일사량 및 수평면 산란일사량은 물론 시간별 평균치로 운량, 기온, 습도 등이 포함된다. 이들 자료로부터 자료의 분포, 평균 및 최고, 최저값 등과 같은 기초자료들을 선별하여 관련 시스템 설계에서 요구하는 기준을 충족하여야 하는 것이다. 그러나 우리나라의 경우, 태양에너지 자원에 대한 정밀한 측정은 1982년 이후 수평면 전일사량, 1990년 이후에서나 법선면 직달일사량에 대하여 본격적으로 이루어진 실정으로, 자료의 표준화 및 신뢰성 확보에는 여전히 상당한 시간과 노력이 요구되는 실정이다. 지속적인 측정과 더불어 요구되는 것으로 측정자료의 가공기술을 들 수 있다. 즉, 측정자료의 품질평가 및 관리 기술, 미측정 또는 불량자료의 복원 기술 및 측정 지역외 자료의 추정을 위한 보간기술 등이다. 이와 같은 기초자료 및 기술에 관한 연구개발은 보다 구체적인 적용에 앞서 필수적으로 이루어져야 할 과제이다.

  • PDF

A Study on the Efficiency Improvement of a 3D Shape Measuring Apparatus With High Speed (고속 3차원 형상 측정 장치의 효율성 향상에 관한 연구)

  • 박승규;이일근;이영훈
    • Journal of the Korea Society of Computer and Information
    • /
    • v.6 no.4
    • /
    • pp.104-109
    • /
    • 2001
  • In this paper, we designed a 3D shape measuring system with high speed and high measurement resolution using line-shaped sine stripes of a LCD projector We proposed an effective method to improve measurement efficiency for a 3D shape measuring system by finding the deficient shape information areas and recovering the shape information efficiently. We experimentally confirmed the improvement of measurement efficiency. Deficient shape information areas can be inevitably existed in a acquired image caused by the camera view angle and surface shapes of an object. The measurement efficiency is turned out to be improved by extracting these shadow areas and recovering the shape information efficiently using both a variable rated normalization and a variable sized phase recovering windows.

  • PDF

A Study on the Performance Improvement of a 3-D Shape Measuring System Using Adaptive Pattern Clustering of Line-Shaped Laser Light (선형레이저빔의 적응적 패턴 분할을 이용한 3차원 표면형상 측정 장치의 성능 향상에 관한 연구)

  • Park, Seung-Gyu;Baek, Seong-Hun;Kim, Dae-Gyu;Jang, Won-Seok;Lee, Il-Geun;Kim, Cheol-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.10
    • /
    • pp.119-124
    • /
    • 2000
  • One of the main problems in 3D shape measuring systems that use the triangulation of line-shaped laser light is precise center line detection of line-shaped laser stripe. The intensity of a line-shaped laser light stripe on the CCD image varies following to the reflection angles, colors and shapes of objects. In this paper, a new center line detection algorithm to compensate the local intensity variation on a line-shaped laser light stripe is proposed. The 3-D surface shape measuring system using the proposed center line detection algorithm can measure 3-D surface shape with enhanced measurement resolution by using the dynamic shape reconstruction with adaptive pattern clustering of the line-shaped laser light. This proposed 3-D shape measuring system can be easily applied to practical situations of measuring 3-D surface by virtue of high speed measurement and compact hardware compositions.

  • PDF

A Four-point Bending Probe Station for Semiconductor Sensor Piezoresistance Measurement (반도체센서 압저항 측정을 위한 4점 굽힘 프로브 스테이션)

  • Jeon, Ji Won;Kwon, Sung-Chan;Park, Woo-Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.35-39
    • /
    • 2013
  • A four point bending apparatus has been developed to measure semiconductor sensor piezoresistance inside a four inch probe station. The apparatus has a footprint of $60{\times}83mm^2$ and can apply $10{\mu}m$ displacements using a vertical micrometer stage. We used finite element analysis to predict and improve the accuracy of the instrument. Finally strain gauge attached on a silicon test piece was used to experimentally verify the setup.

Vibration Evaluation and Accuracy Improvement for a Digital Pile Rebounding and Penetration Monitoring System (DPRMS) (디지털 항타관리기(DPRMS)의 진동영향 평가 및 측정 정밀도 향상 방안에 관한 연구)

  • Hong, Jung-Taek;Lee, Kye-Young;Lee, Sang-Hun;Han, Song-Soo;Chung, Jin-Tai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.514-520
    • /
    • 2006
  • In this study, the performance of a digital pile rebounding and penetration monitoring system (DPRMS) is evaluated and the measurement precision of the DPRMS is improved. The DPRMS is a high speed line-scanning camera system to measure the rebound and penetration of a pile in a construction work. A main problem in the DPRMS is a measurement error, which is caused by a shock or vibration due to a hammer impact. The measurement error is investigated by analyzing vibration signals of the DPRMS during the impact. Moreover, the frequency response functions of the DPRMS are also analyzed. As a result, it is found that the tripod height has an influence on the DPRMS performance and a shorter tripod is better. One more founding in this study is that the DPRMS should be placed with a appropriate distance from a pile for improving the measurement precision.