• Title/Summary/Keyword: 측정허용기준

Search Result 302, Processing Time 0.025 seconds

Change of Ammonia Consumption with Gas Turbine Output in DeNOx System for a 580 MW Combined Cycle Power Plant (580 MW급 복합발전소 탈질설비에서 가스터빈 출력에 따른 암모니아 소모량 변화)

  • Jang, Yong-Woo;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.15 no.3
    • /
    • pp.23-28
    • /
    • 2019
  • In this study, ammonia consumption by gas turbine output was adjusted to find out the amount of ammonia consumption that complies with the enhanced Air Quality Preservation Act and internal regulation emission standards in SCR type DeNOx System for a 580 MW Sejong Combined Cycle Power Plant. For measurements, the gas turbine output was varied to 50, 99, 149, 198 MW and ammonia consumption was adjusted with the combustion gas and ammonia supply conditions fixed at each stage. When the emission limit were change from 10 ppm to 8 ppm, ammonia consumption was increased from 78, 93, 105, 133 kg/h to 89, 113, 132, 176 kg/h. The increase rate of ammonia consumption was 14, 22, 26, 32% per output category compared to the 10 ppm emission limit, which was shown to increase as output increased.

Comparative Analysis of Treatment Planning System and Dose Distribution of Gamma knife PerfexionTM using EBT-3 Film (EBT-3 필름을 사용한 감마나이프 퍼펙션TM의 치료 계획 시스템 및 선량 분포 비교 분석)

  • Jin, Seongjin;Kim, eongjin;Seo, Weonseop;Hur, Beongik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.509-515
    • /
    • 2017
  • The purpose of this study is to measure the 3 dimensional dose distribution of Gamma knife $Perfection^{TM}$, make a comparative analysis of the result and establish the measurement method for the procedures using EBT3 film. The dose distributions of the Gamma knife $Perfection^{TM}$ installed in two hospitals were evaluated in accuracy and precision. For accuracy, the difference between the mechanical center axis and the dose center axis was assessed on a 4 mm collimator. The allowed difference in accuracy is within 0.3 mm and it was measured as 0.098 mm, 0.195 mm for A hospital and 0.229 mm, and 0.223 mm for B hospital. For precision the difference between the FWHM(Full Width at Half Maximum) of Gamma Plan and measurement in the 4, 8, and 16 mm collimators was calculated. The allowed difference in precision is less than ${\pm}1mm$. The value of the hospital A was -0.283 ~ 0.583 mm, and the hospital B was -0.857 ~ 0.810 mm. When analyzing the dose distributions using the image-j program, it is necessary to establish a clearer reference point of the measurement point, and it is considered that the comparison of the dose distribution should be performed in actual treatment irradiation dose with a high dose usable film.

Evaluation of the Seismic Stability of Fill Dam by Shaking Table Tests (진동대 시험을 통한 Fill Dam의 내진 안정성 평가)

  • Yoon, Won-Sub;Chae, Young-Su;Park, Myeon-Gu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.4
    • /
    • pp.81-92
    • /
    • 2011
  • In order to understand evaluation of the seismic stability of a fill dam, we made chambers of 1:100, 1:70, and 1:50 (the ratio of the miniature), considering the law of similarity based on drawings of three representative cross sections. And we measured an increase in acceleration, excess pore water pressure, and vertical/horizontal displacement after applying Hachinohe wave (long period), Ofunato wave (short period), and artificial wave, complying with the domestic standards, in order to evaluate the stability and interaction between the ground, the structure, and fluids based on the measurements. As a result, we could observe that displacement of the target cross section was relatively small compared to the allowed level of 30 cm, ensuring proper stability for an earthquake. Regarding the acceleration measurements, the increase rate was 20% for Hachinohe wave and Ofunato wave but 30% for the artificial wave. With respect to the excess pore water pressure, it was lower than 1 (which is the permissible ratio for liquefaction) ensuring proper stability as well.

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

The Measurement System for Small Microphone's Electro Acoustic Characteristics (소형 마이크로폰의 전기적인 음향 특성 측정 시스템)

  • Park, Byoung-Uk;Kim, Hack-Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.259-266
    • /
    • 2007
  • The parameters of electric acoustic characteristic used as standards to evaluate the performance of a small microphone are composed of sensitivity, harmonic distortion, frequency response, directivity and others. Such characteristic parameters should be designed differently depending on a purpose, so it is important to verify whether a small microphone was made appropriately for the purpose after measuring the acoustic characteristics. Therefore, a system that can measure the acoustic characteristic parameters of a small microphone using DSP, not only simultaneously but also in real-time, was implemented in this paper. To verify the implemented system, four kinds of microphones were measured and the results were compared with the data values of the acoustic characteristics of each microphone. There were a little discrepancy between them because the conditions when measuring the characteristics were not identical. But it was verified that the errors are within the error tolerance and it proved that the system can be used in place of the conventional equipment used in measuring the acoustic characteristics of small microphones.

  • PDF

Improvement of Direct Measurement of Bottom Shear Stress Using Shear Plate (전단평판을 이용한 바닥전단응력의 직접 측정 방법의 개선)

  • Jung, Dong Gyu;Kim, Young Do;Park, Yong Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.70-70
    • /
    • 2016
  • 하천시설물 설계, 시공 및 관리에 있어서 바닥전단응력은 매우 중요하다. 예를 들어, 호안 등 시설물의 허용 소류력을 계산하거나, 하천의 유사량을 예측하는 데 있어서 바닥전단응력이 기준으로 쓰인다. 정상 등류의 경우, 수로 내 수체에 작용하는 중력과 수로 바닥 및 측면에 작용하는 마찰력의 평형을 고려함으로써 바닥전단응력을 산정할 수 있다. 본 연구에서는 식생을 제외한 아크릴수로에서의 전단판의 움직임을 이용한 바닥전단응력 측정장치를 설계, 교정 및 검증을 실시하였다. 이 전단판은 수체와 바닥면에서 발생하는 마찰력에 의해 변위가 발생하고 이 변위를 바닥전단 응력으로 산정하였다. 직접 측정한 바닥전단응력은 기존에 연구된 두 가지 방법과 비교하여 검증하였다. 비교 검증을 위한 실험은 폭 0.3 m, 길이 10 m인 고속수로에서 Froude수 1이상, Reynolds수 20000이상의 사류이면서 난류인 상태로 실험을 진행하였으며 유속은 PIV을 이용하여 측정하였다. 비교 검증을 위한 첫 번째방법은 Reach-avrage공식을 기초로 manning의 평균 유속 공식을 이용한 바닥전단응력을 산정하는 방법으로 일반적으로 간단한 경험식을 이용하여 바닥 전단응력을 산정하는 방법이다, 두 번째는 Reynolds stress를 산정하는 방법으로 PIV를 통해 흐름방향의 연직프로파일의 유속을 측정 한 후 레이놀즈 분해법에 의해 산정된 난류 강도를 측정하여 Reynolds stress를 산정한 후 Shear stress를 산정하는 방법을 사용하였다. 마지막으로 본 연구에서 가로 0.14 m, 세로 0.14 m의 전단판으로 구성된 바닥전단응력 측정장치를 개발하여 실험을 진행하면서 앞에서 언급한 두가지 방법을 측정하는 동시에 장치를 이용하여 바닥전단응력을 직접측정하여 총 3가지 바닥전단응력을 비교하였다.

  • PDF

A Study in EMC Environment Measuring of Marine Ship (선박의 EMC 환경 측정에 관한 연구)

  • Kim, Dong-Seek;Cho, Hyung-Rae;Min, Kyeong-Sik
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.141-146
    • /
    • 2005
  • Recently, the accidents on the sea have arisen due to the increase of the nautical traffic and the digitization of equipments for marine. Therefore, IMO(International Maritime Organization) have provided the recommendation of EMI and EMS for radio communication and equipments of marine from SOLAS cobvention at July 1st 2002. In this paper, we measured EMC environment on the HANBADA, which is Korea Maritime University training ship, for basic EMC environment of a ship. The measuring point was Bridge and Engine Control Room of the ship, we measured the test point that was set at random. Measured Band is from 30 MHz to 2 GHz, polarization measurement is processed both vertical and horizontal polarizaion. We analysed the results in consideration of permissible criteria.

  • PDF

Accuracy Analysis of Single Frequency Receiver for Baseline Range (기선장에 대한 일주파 수신기의 정확도 분석)

  • 박운용;신상철;안상준;홍정수
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.103-107
    • /
    • 2003
  • 현재 관측점간의 3차원 상대위치를 구하고 기준점의 측지학적 좌표ㆍ표고를 결정하는 작업을 수행하는 GPS(Global Positioning System) 측량은 신호가 전파인 관계로 대기권의 전파지연 오차를 포함하게 되며, 전리층 지연은 주파수에 반비례하는 특성이 있으므로 지역의 대소에 구분 없이 이주파수 수신기(dual-frequency GPS receiver)를 사용하여 정확하게 지연시간을 측정하고 그로 인한 측위정밀도의 정확성을 확보하고 있다. 본 연구는 비교적 낮은 가격인 일주파 수신기를 사용하여 기선거리별로 삼각점을 선점한 후 동일 시간에 관측을 실시하고 취득한 데이터 값을 추출한 후 기선거리에 따른 허용오차를 분석하고, 그 활용성 및 경제성과 일주파 수신기의 기선에 대한 사용 가능성을 분석하였다. 그 결과, 100km이내의 지역에서는 일주파 수신기 만으로도 충분히 만족스러운 결과를 얻을 수 있었다.

  • PDF

The Comparison of Acceptance Criteria and Flaw Size Measurement between ASME and RCC-M Code in Ultrasonic Examination (초음파검사시 ASME와 RCC-M CODE에 따른 결함 크기측정 및 허용기준 비교평가)

  • Kim, B.C.;Lim, H.T.;Lee, J.P.;Joo, Y.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.8 no.1
    • /
    • pp.6-11
    • /
    • 1988
  • The comparison and analysis of flaw detectability, flaw sizing methods and allowable criteria in accordance with the applicable codes, ASME and RCC-M Code, in ultrasonic examination of pressure vessel in nuclear power plants were studied. Accordding to the codes, calibration blocks were made. The artificial flaws such as disc and band types in test specimens were machined. They were detected and evaluated with etch code requirements and measured values were compared with the actual flaws.

  • PDF

Control Techniques Micro-Vibration for Sensitive Mechanical Equipment (정밀기기의 미진동 제어기술)

  • 이홍기;이규섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.175-181
    • /
    • 1991
  • 정밀장비의 진동환경을 평가, 제어하기 위해서는 우선적으로 미진동 환경을 측정할 수 있는 장비와 기술이 필요하며, 방진 system 구성시 국내에서는 방진소재의 개발이 요구되고 있다. 그리고 진동에 민감한 정밀장비들을 사용 하는 반도체 및 정밀공장에서는 진동허용 기준을 나타내는 data sheet가 필 요하고 사용자측에서도 장비의 진동 test성적서를 장비구매시 제작사에 요구 할 필요성이 있다. TEM(투과형 전자현미경)의 경우 음압에 의한 가진문제도 대두되고 있으며 정밀장비가 최대의 성능을 발휘하기 위해서는 이러한 문제 를 검토해야 한다. 만일 국내에서 진동에 민감한 정밀장비를 제작시 장비의 진동 특성을 평가할 수 있는 실험장치와 기술이 필요하다.

  • PDF