• Title/Summary/Keyword: 측정판

Search Result 1,418, Processing Time 0.027 seconds

A Study on the Characteristics of the Acoustic Reflection of the Wedge Shaped Underwater Sound Absorptive Tile (쐐기형 수중음파 흡수타일의 음반사 특성 연구)

  • Kang, Sung-Oug;Hong, Woo-Young;Song, Yeong-Il;Lyu, Ki-Sang;Baek, Chil-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.45-50
    • /
    • 1997
  • Four different wedge angle absorptive tiles were designed and made, and the magnitudes of the reflected acoustic fields by the wedge shaped underwater sound absorptive tiles were measured. The minimum magnitude was found at the angle of 30$^{\circ}$ and the maximum of it was found at the wedge angle of 120$^{\circ}$ from measured the reflected acoustic fields at the front sides of the tiles. The fact that as wedge angle of the absorptive tile increases, the reflection coefficient is increasing is verified. The measured reflected acoustic fields were not dependent on the frequency in the range of 10kHz~30kHz used in this experiment for the same wedge angle tile. The measured reflected acoustic fields at the back sides of the tiles show that they are independent from both type of the absorptive tiles and the frequencies used in the experiments. The measured values and the computed values by the numerical model for the reflected acoustic fields of the wedge shaped absorptive tiles are fairly well comparable with one another.

  • PDF

Validity and Reliability of a Korean version of Leader Rapport Management (한국어판 리더 레포 관리 측정도구의 신뢰도와 타당도)

  • Han, Jeong-Won;Kim, Nam-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.129-136
    • /
    • 2016
  • This was a methodological study that verified the validity and reliability by translating and modifying the Korean Version of LRM (leader rapport management) tool. This study verified the content validity, construct validity, concurrent validity and convergent validity on 200 nurses working in general hospitals. The LRM tool was analyzed using a total of 3 factors (ego, autonomy, association) and 12 items. The reliability of this tool (Cronbach's ${\alpha}$) was 0.83 to 0.86. The tool showed a high level of reliability and validity. The difference from preceding studies showed that the LRM is a measurement tool that considers multi-dimensional aspects, and it can provide the basic material of report management methods in diverse aspects for clinical nurse managers.

Strain Analysis in the Skin and Core Layers of Cross-Ply Composite Laminates Using A-EFPI Optical Fiber Sensor (광섬유 A-EFPI 센서를 이용한 직교적층 복합재료의 표피층 및 내부층의 변형률 해석)

  • 우성충;박래영;최낙삼;권일범
    • Composites Research
    • /
    • v.17 no.5
    • /
    • pp.15-24
    • /
    • 2004
  • Longitudinal strains (${\varepsilon}_x$) of the core and skin layers in glass fiber reinforced plastic (GFRP) cross-ply composite laminates have been measured using the embedded optical fiber sensor of absolute extrinsic Fabry-Perot interferometer (A-EFPI). Transmission optical microscopy was used to investigate the damage behavior around the A-EFPI sensor. Foil-type strain gauges bonded on both the upper and lower surfaces were used for the measurement of the surface strains. It was shown that values of ${\varepsilon}_x$ in the interior of the skin layer and the core layer measured by embedded A-EFPI sensor were significantly higher than that of the specimen surface measured by strain gauges. The experimental results agreed well with those from finite element analysis on the basis of uniform stress model. Large strains in the core layer led to the occurrence of many transverse cracks which drastically reduced the strain at failure of optical fiber sensor embedded in the core layer.

2단 GM형 맥동관 냉동기 적용 크라이오 펌프 개발

  • Go, Jun-Seok;Park, Seong-Je;Go, Deuk-Yong;Kim, Hyo-Bong;Hong, Yong-Ju;Yeom, Han-Gil;Gang, Min-Jeong;Gang, Sang-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.85-85
    • /
    • 2011
  • 반도체 생산 공정은 청정 환경을 요구하며, 이를 위해서는 고진공 환경이 필수적인 요소이다. 반도체 생산 라인의 고진공 환경 조성을 위해서는 주로 복합 분자 펌프와 크라이오 펌프가 사용되고 있다. 본 연구에서는 기존의 상용 크라이오 펌프에 사용되던 GM 극저온 냉동기를 맥동관 냉동기로 대체하기 위한 연구를 수행하였다. 맥동관 냉동기는 저온부에 움직이는 부분이 없어 진동이 작고, 신뢰성이 높은 장점이 있어 이를 이용한 크라이오 펌프는 반도체 생산 공정의 공정 정밀도 향상에 기여할 수 있을 것으로 기대된다. 맥동관 냉동기는 크라이오 펌프에 사용하기 위하여 2단으로 구성되며, 저온부가 U자 형상으로 개발되었다. 상용화를 고려하여 로터리 밸브와 위상조절기구가 위치하는 상온부는 일체형으로 제작하였다. 제작된 맥동관 냉동기의 기초 냉각 성능 시험 결과 부하가 없는 조건에서 최저도달온도는 1단과 2단에서 각각 42.53 K과 8.68 K 이었으며, 부하 시험 결과 1단과 2단에서 각각 40 W at 82.97 K, 10 W at 20.51 K의 냉각 능력을 갖는 것으로 측정되었다. 개발된 맥동관 냉동기에 복사차폐막 및 1차, 2차 냉각판을 설치하여 크라이오 펌프를 구성하였고, 기체 질소에 대한 배기 속도 측정 시험을 수행하였다. 배기속도 측정 결과 배기속도는 2차 냉각판의 형상에 크게 영향을 받는 것이 확인되었으며, 약 650 L/의 배기속도를 갖는 것으로 측정되었다. 실험 결과를 바탕으로 크라이오 펌프로 작동시 맥동관 냉동기의 동작 특성 및 배기 속도 향상을 위한 방안을 논의하였다.

  • PDF

Development of Non-contact Image Measuring Technique for Evaluating Micro-relief (미세주름 측정을 위한 비접촉식 영상측정기술의 발전)

  • Kim, Nam-Soo;Kim, Yong-Min
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.253-257
    • /
    • 2005
  • Assurance of the objectivity and reproducibility is a major key point in wrinkle measurement used for evaluating the degree of skin aging. The measurement of relief is quickly converted to a non-contact method, of which tools or instruments do not come in contact with skin directly, to minimize the artificial effects which influence the shape or depth of the relief. Here, we showed how wrinkle measurement techniques have been changed briefly and compared PRIMOS and replica method in the point of view of measurement principle and features, the former is non-contact fringe projection tool and the latter is contact type of the method.

A Study of QMSA Characteristics According to the Gap Variance between Ground Plane and Radiation Patch (접지판과 방사 패치 사이의 간격 변화에 따른 QMSA의 특성 연구)

  • Ryu, Hyun;Park, Sung-Kyo;Park, Chong-Baek
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.11-16
    • /
    • 1999
  • In this paper, we designed and fabricated QMSA(Quarter-Wavelength Microstrip Antenna) for 850MHz band on the CGP-500 PTFE substrate(by CHUKOH company) with ε/sub r/=2.6, H=1.6mm(±0.08), where width of the radiation patch is .identical with that of the ground plane. A well matched feed point was obtained by experiments and this QMSA was fed by using prove feed method. The resonant frequencies and the return losses were mcasured by cutting the gap L₃ between the radiation patch and the ground plane, with a 5mm cutting length, step by step. As a result, we found that the measured return losses were decreased and the resonant frequencies were increased when the gap L₃ was shorter, especially under 10mm, unlike we had expected.

  • PDF

Balance plate system to monitor and analysis the center of pressure(COP) of the body (인체 압력중심 계측과 분석을 위한 평형판 시스템의 개발)

  • Cha, Eun-Jong;Song, Chun-Hee;Lee, Tae-Soo;Lee, Kyung-Moo;Kim, Nam-Kyun;Kim, Yeon-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.63-67
    • /
    • 1995
  • 신체 자세균형의 안정도를 반영하는 압력중심(COP)을 계측하기 위해 정삼각형 모양의 평형판 시스템을 설계, 제작하였고 그 유용성을 평가하였다. 재질로는 강도와 가공성이 뛰어난 듀랄루민을 사용하였고 압력중심(COP)의 위치를 계측하는 힘센 서로는 공업용 로드셀 3개를 사용하였다. COP신호를 검출하는 전자회로를 제작하여 실험한 결과 평형판의 COP 위치측정 오차는 2% 미만이었다. 시스템의 임상응용가능성을 평가하기 위하여 정상인 10명과 이학적 평가가 정상인 환자 4명을 대상으로 임상실험을 수행하였다. 자세안정도를 반영할 척도로써 COP신호의 표준편차($SD_x,\;SD_y,\;SD_r$)를 설정하여 자세가 불안정해짐에 따라, 그리고 시각의 영향이 배제됨에 따라 이 값들이 증가하는 것을 관찰하였다. 또한 환자의 경우에는 정상인과 현저한 차이를 보였다. 즉, 본 평형판시스템이 자세안정도를 정량적이고 예민하게 계측할 수 있음을 확인하였고 임상적 실용성을 검증하였다.

  • PDF

A Study of Effective Method to Update the Database for Road Traffic Facilities Using Digital Image Processing and Pattern Recognition (수치영상처리 및 패턴 인식에 의한 도로교통시설물 DB의 효율적 갱신방안 연구)

  • Choi, Joon-Seog;Kang, Joon-Mook
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.2
    • /
    • pp.31-37
    • /
    • 2012
  • Because of road construction and expansion, Update of the road traffic facilities DB is steadily increased each year, and, Increasing drivers and cars, safety signs for traffic safety are required management and additional installation continuously. To update Safety Sign database promptly, we have developed auto recognition function of safety sign, and analyzed coordinates accuracy. The purpose of this study was to propose methods to update about road traffic facilities efficiently. For this purpose, omni-directional camera was calibrated for acquisition of 3-dimensional coordinates, integrated GPS/IMU/DMI system and applied image processing. In this experiment, we proposed a effective method to update database of road traffic facilities for digital map.

Fabrication and driving experiment of 2.4mm size mirror for optical pick-up head (광기록 장치의 픽업헤드용 2.4mm 크기의 미러의 제작과 구동실험)

  • Park, Keun-Woo;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2266-2268
    • /
    • 2000
  • 본 논문에서는 스캐닝 미러의 일종으로, 광저장 장치의 픽업헤드용으로 미세회전을 하면서 레이저 빔을 편향시키는 용도로 사용되는 미러를 제작하고 구동실험을 하였다. 제작된 미러의 크기는 $2400{\times}2400{\times}64{\mu}m^3$이고, 빔 스프링은 $500{\times}9.6{\times}64{\mu}m^3$이다. 니켈 전해 도금으로 29${\mu}m$ 높이의 구동 전극을 제작하였고(세가지 모델: 공기통로가 없는 전극, 공기통로와 간격이 각각 200${\mu}m$인 전극, 공기통로와 간격이 각각 100${\mu}m$인 전극), 미러판과 전극을 조립하여(미러판과 전극 사이의 간격은 각각 29${\mu}m$, 26${\mu}m$, 26${\mu}m$) 구동실험을 하였다. 공진 주파수의 계산간은 576Hz, 측정값은 3개의 미러에서 모두 568Hz이었다. 전극과 미러판의 간격이 최대 접근거리 18${\mu}m$가 되도록 미세 회전을 시켰을 때, 공기통로가 없는 전극에서는 공진 주파수가 524Hz, 공기통로가 200${\mu}m$인 전극에서는 544Hz로 각각 감쇠되었고, 공기통로가 100${\mu}m$인 전극에서는 그대로 568Hz이었다.

  • PDF

가스장 이온원 시스템에서 마이크로 채널 플레이트의 잡음 제거 방법

  • Han, Cheol-Su;Park, In-Yong;Jo, Bok-Rae;Park, Chang-Jun;An, Sang-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.422.2-422.2
    • /
    • 2014
  • 가스장 이온원(GFIS: Gas Field Ionization Source)은 전자현미경보다 분해능이 향상된 이온현미경의 광원으로 사용하기 위하여 연구되고 있고, 큰 각전류 밀도, 작은 크기의 가상 이온원 그리고 좁은 에너지 퍼짐을 특징으로 한다. 여러 가지 장점을 가지고 있는 GFIS을 개발하기 위해서는 GFIS에서 발생된 이온빔의 형상을 관찰 것이 매우 중요하며, 이러한 관찰을 위한 시스템에는 주로 마이크로 채널 플레이트 (MCP: Micro Channel Plate)가 사용된다. MCP는 채널내부에 입사한 입자의 에너지에 의해서 생성된 이차전자를 수 천 배에서 수 백 만 배 이상 증폭시켜 형광판에 조사하고 발광시키는 방법으로 작은 신호를 영상으로 관찰 할 수 있도록 한다. MCP의 큰 증폭비는 작은 크기의 신호를 큰 신호로 증폭하여 관찰하는데 용이하여, GFIS 방법으로 생성된 이온빔(이온빔 전류 값은 pA 수준)을 관찰하기에 적합하다. 그러나 MCP를 이용하여도 증폭된 이온빔의 세기가 매우 작기때문에 생성된 이온빔 형상을 정확하게 관찰하기 위해서는 MCP의 형광판을 촬영하는 카메라 노출시간을 길게하여 데이터 수집 시간을 늘려야 하는 문제가 있다. 본 발표에서는 이온빔 형상 관찰에 소요되는 시간을 단축하기 위하여 MCP의 잡음이 GFIS의 이온빔 이미지 관찰에 미치는 영향을 분석하고 이를 제거 방법을 소개한다. 본 연구에서는 GFIS 방출 이온빔의 이미지에 포함된 MCP 잡음 특성을 장(전계)이온현미경 (Field Ion Microscope)실험을 통하여 분석하였고, 디지털 이미지 처리 방법을 이용하여 방출 이온빔 이미지에서 MCP 잡음을 제거하여 방출 이온빔 이미지만 추출할 수 있었다. 본 연구에서 제안한 방법을 GFIS 방출 이온빔 관찰시스템에 적용함으로써 기존 방법에 비해 노출시간을 단축하여 방출 이온빔을 관찰 할 수 있었으며, 노이즈 제거 효과로 향상된 이온빔 형상을 얻을 수 있었다. 본 연구결과의 관찰시간 단축과 향상된 이온빔 형상 획득은 이온현미경 개발에 필수적인 단원자 이온빔을 보다 효율적으로 개발할 수 있으며 디지털 이미지 처리로 GFIS 이온빔 생성을 자동화하는데 응용할 수 있다. 더불어 기존방법에 비해 이미지 획득을 위한 MCP의 노출시간을 단축할 수 있으므로 실험장비 수명 단축 방지 및 관리에 큰 장점이 있다.

  • PDF