• Title/Summary/Keyword: 측정오차

Search Result 4,685, Processing Time 0.036 seconds

Leukocyte count and hypertension in the health screening data of some rural and urban residents (일부 농촌과 도시의 건강선별조사 자료로 본 백혈구수와 고혈압과의 관계)

  • Lee, Choong-Won;Yoon, Nung-Ki;Lee, Sung-Kwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.363-372
    • /
    • 1991
  • We used the health screening data of some rural and urban residents to examine the cross-sectional association between leukocyte count and hypertension. The 206 male and 203 female rural residents were selected by multi-stage cluster sampling method in Kyungsan-Kun area of Kyungbuk province in 1985 and 600 urban residents were selected by the same sampling method as the rural residents in Daegu city of the same province in 1986 compatible with age-sex distribution of Daegu city of 1985 census, but of whom 384 actually responded. The rest of 600 were replaced by age and sex with those who were members of the medical insurance plan visiting the health management department of the university hospital to get the biannual preventive medical checkups. Excluded in the analysis were those having hypertensive history, diseases and extreme outlying values of the screening tests, leaving 373 rural and 571 urban residents. Leukocyte count was measured with ELT-8 Laser shadow method and the unit $cells/mm^3$, Blood pressures were determined with an aneroid sphygmomanometer with pre-standardized method and hypertensives were defined as those showing systolic blood pressure more than 140mmHg and/or diastolic blood pressure more than 90mmHg. Total residents pooled (N=944) showed a significant difference between hypertensives and normotensives ($6965.93{\pm}1997.01\;vs\;6490.61{\pm}1941.32,\;P=0.00$) and in rural residents was noted the similar significant difference (P=0.03). None of significant differences were noted in any stratum stratified by residency and sex. Compared to the lowest quintile of WBC, 2/5 quintile showed odds ratio 0.99 (95% Confidence interval, Ci 0.62-1.59), 3/5 quintile 1.41 (95% CI 0.90-2.21), 4/5 quintile 1.76 (95% CI. 1.14-2.72), and highest quintile 1.80 (1.15-2.82) in the total residents. Likelihood ratio test for linear trend for it indicated a significant trend ($X^2_{trend}=5.53,\;df=1,\;P<0.05$). There were no other significant odds ratios compared to the lowest quintile of WBC in strata stratified by residency and sex. The odds ratios in total residents which had showed significant odds ratios became nonsignificant and of reduced magnitude after controlling age, frequency of smoking and drinking with multiple logistic. regression. In each stratum, it changed magnitudes of odds ratios slightly and unstably. None of the trend tests showed any significant trend. These results suggest that the Friedman et al's finding of association between leukocyte count and hypertension may be due to an statistical type I error resulting from the data dredging in an exploratory study, in which more than 800 variables were screened as possible predictors of hypertension.

  • PDF

Nutrient Composition of Benthic Diatom Cultured on Plate at Four Areas in Spring (봄철 해역별 파판배양 부착규조류의 영양성분)

  • 김해영;허성범
    • Proceedings of the Korean Aquaculture Society Conference
    • /
    • 2003.10a
    • /
    • pp.143-144
    • /
    • 2003
  • 봄철 해역에 따른 부착미세조류의 영양성분 변화를 알아보기 위하여 본 실험을 수행하였다. 실험은 울진, 부안, 완도, 부산 지역에서 봄철인 2~4월 동안 실시되었으며 실험간의 오차를 줄이기 위해 실험 시작일의 차이는 최대 10일 이내로 하였다. 배양을 위한 실험해역의 기초 조사로 배양지역 연안해수의 수온, 염분, pH, 총질소, 총인, Chlorophyll-a의 측정을 하였고 각 지역의 부착미세조류를 수확하여 영양분석을 하였다. 실험에 사용된 파판은 전복 종묘생산에 이용되는 규조배양용 파판과 틀을 이용하였고 실험기간은 총 8주 동안 실시하였다. 2주마다 파판을 수거한 뒤 부착된 미세조류를 부드러운 솔로 분리하여 원심 분리한 후 지방산과 아미노산의 측정을 하였다. 또 각 시료의 일정량을 Sedwick-rafter counting chamber를 이용하여 검경ㆍ계수한 후 이를 단위면적당 개체수(cells/$\textrm{cm}^2$)로 환산하여 biomass를 구하였다. 봄철 지역간의 수온의 범위는 13.9~16.6$^{\circ}C$를 보였으며 울진이 가장 높고 부안지역이 가장 낮았다. 염분은 부안지역의 염분이 평균 2$\textperthousand$ 이상 낮았으며 그 외의 지역은 큰 차이가 없었다. pH는 7.77~8.21의 범위를 보이고 있었으며 질산염 농토는 부산이 0.265mg/$\ell$로 최대값을 보였고 울진이 0.032mg/$\ell$로 제일 낮았다. 인산염 농도는 완도지역이 0.018mg/$\ell$로 최대치를 보였고 부안은 검출되지 않았다. Chlorophyll-a의 농도는 울진지역이 0.66mg/$\ell$으로 제일 낮았으며 부산이 2.69mg/$\ell$, 부안지역이 2.27mg/$\ell$ 로 높은 값을 보였다. 봄철 지역에 따른 부착미세조류의 아미노산 분석결과는 울진이 실험지역 중 제일 높은 총 아미노산과 필수아미노산의 함량을 나타냈으며 각 지역별로 울진은 4주에 20.3%, 부안은 8주째 8.1%, 완도는 8주째 4.7%, 부산은 6주째 10.4%로 서로다른 시기에 높은 아미노산의 함량을 나타냈다. 실험지역 부착미세조류의 지방산 결과를 보면 전 실험기간동안 지방산 중 대부분은 $C_{18}$이하의 포화 또는 불포화 지방산이 주를 이루고 있었으며 palmitic acid( $C_{16:0}$)와 palmitoleic acid( $C_{16:0}$)의 양이 전체 지방산 함량중 37.47~75.94%로 대부분을 차지하고 있었다. 그리고 n-3HUFA(high unsaturated fat쇼 acids)인 EPA는 부안지역이 2주째 20.85%로 전체 지역중 함량이 제일 높았고, 울진은 실험기간중 6주가 14.76%로 제일 높은 함량을 보였다. 완도는 6주에만 10.97%의 함량을 보였으며 부산지역의 시료에서는 EPA의 검출이 없었다. 봄철 각지역에 설치된 파판에서의 부착미세조류 출현량을 보면 2주째의 부착미세조류량은 부안이 8.3$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 높았고 부산이 0.6$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 낮았다. 울진의 경우 0.7$\times$$10^3$ cells/$\textrm{cm}^2$로 부산과 비슷하게 낮은 출현량을 보였고 완도는 2.4$\times$$10^3$ cells/$\textrm{cm}^2$였다. 4주째의 출현량은 울진지역이 471.1$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 높았으며 부안, 완도, 부산 순으로 출현량이 낮았고 특히 부산은 1.2$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 낮았다. 6주째의 출현량은 울진 지역이 368.6$\times$$10^3$ cells/$\textrm{cm}^2$로 가장 높았으며 부안 89.8$\times$$10^3$ cells/$\textrm{cm}^2$, 완도 25.1$\times$$10^3$ cells/$\textrm{cm}^2$, 부산 5.9$\times$$10^3$ cells/$\textrm{cm}^2$ 순이었다. 8주째의 경우에도 울진, 부안, 완도, 부산이 각각 255.8$\times$$10^3$ cells/$\textrm{cm}^2$, 157.8$\times$$10^3$ cells/$\textrm{cm}^2$, 44.3$\times$$10^3$ cells/$\textrm{cm}^2$, 1.1$\times$$10^3$ cells/$\textrm{cm}^2$로 4주, 6주의 경우와 같은 경향을 보였다.보였다.

  • PDF

Thermal Properties of Granite from the Central Part of Korea (한국 중부 지역의 화강암 열물성)

  • Kim, Jongchan;Lee, Youngmin;Koo, Min-Ho
    • Economic and Environmental Geology
    • /
    • v.47 no.4
    • /
    • pp.441-453
    • /
    • 2014
  • Thermal and physical properties were measured on 206 Jurassic granite samples obtained from three boreholes in the central part of Korea. Thermal conductivity(${\lambda}$), thermal diffusivity(${\alpha}$), and specific heat(Cp) were measured in a laboratory; the average values are ${\lambda}$=2.813 W/mK, ${\alpha}=1.296mm^2/sec$, and Cp=0.816 J/gK, respectively. In addition, porosity(${\phi}$), and dry and saturated density(${\rho}$) were measured in the laboratory; the average values are ${\phi}$=0.01, ${\rho}(dry)=2.662g/cm^3$ and ${\rho}(saturated)=2.67g/cm^3$, respectively. Thermal diffusivity of 10 granite samples were measured with increasing temperature from $25^{\circ}C$ to $200^{\circ}C$. In this study, we found that thermal diffusivity at $200^{\circ}C$ is about 30% lower than thermal diffusivity at $25^{\circ}C$. In correlation analysis, thermal conductivity increases with increasing thermal diffusivity. However, thermal conductivity does not show good correlation with porosity and density. Consequently, we know that thermal conductivity of granite would be more influenced by mineral composition than by porosity. We also derived ${\rho}=-2.393{\times}{\phi}+2.705$ from density and porosity data. XRD and XRF analysis were performed to investigate effects of mineral and chemical composition on thermal conductivity. From those results, we found that thermal conductivity increases with increasing quartz and $SiO_2$, and decreases with increasing albite and $Al_2O_3$. Regression analysis using those mineral and chemical composition were carried out ; we found $K=0.0294V_{Quartz}+1.93$ for quartz, $K=0.237W_{SiO_2}-14.09$ for $SiO_2$, and $K=0.053W_{SiO_2}-0.476W_{Al_2O_3}+6.52$ for $SiO_2$ and $Al_2O_3$. Specific gravities were measured on 10 granite samples in the laboratory. The measured specific gravity depends on chemical compositions of granite. Therefore, specific gravity can be estimated by the felsic-mafic index(F) that is calculated from chemical composition. The estimated specific gravity ranges from 2.643 to 2.658. The average relative error between measured and estimated specific gravities is 0.677%.

A Development of Traffic Queue Length Measuring Algorithm Using ILD(Inductive Loop Detector) Based on COSMOS (실시간 신호제어시스템의 대기길이 추정 알고리즘 개발)

  • seong ki-ju;Lee choul-ki;Jeong Jun-ha;Lee young-in;Park dae-hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.85-96
    • /
    • 2004
  • The study begin with a basic concept, if the occupancy length of vehicle detector is directly proportional to the delay of vehicle. That is, it analogize vehicle's delay of a occupancy time. The results of a study was far superior in the estimation of a queue length. It is a very good points the operator is not necessary to optimize s1, s2, Thdoc. Thdoc(critical congestion degree) replaced 0.7 with 0.2 - 0.3. But, if vehicles have been experience in delay was not occupy vehicle detector, the study is in existence some problems. In conclusion, it is necessary that stretch queue detector or install paired queue detector. Also I want to be made steady progress a following study relation to this study, because it is required traffic signal control on congestion.

  • PDF

Determination of Electron Beam Output Factors of Individual Applicator for ML-15MDX Linear Accelerator (선형가속기 ML-15MDX의 각 Applicator에 대한 전자선 출력선량 계수 결정)

  • Park, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.87-99
    • /
    • 1994
  • Purpose : The determination of electron beam output factor was investigated from individual applicator for various energy of ML-15MDX linear accelerator. The output factor of electron beam was extended from square to rectangular field in individual applicator size through with a least-square fit to a polynomial expression. Materials : In this experiments. the measurement of output was obtained from 2${\times}$cm$^2$ to 20${\times}$20cm$^2$ of field size in different applicator size for 4 to 15 MaV electron beam energy. The output factor was defined as the ratio of maximum dose output on the central axis of the field of individual applicator size to that of a given field size. Applicator factors were derived from comparing with the output dose of reference field size 10${\times}$10cm$^2$. The thickness of block was specially designed as 10mm in thickness of Lipowitz metal for field shaping in all electron energy. Two types of output curves are included as output factors versus side of square fields and that of variable side length for X and Y in one-dimensional to compare the expected values to that of experiments. Results : Expected output factors of rectangular which was derived from that of square fields in individual applicator size from 2${\times}$2cm$^2$ to 20${\times}$20cm$^2$ in different electron energy was very closed to that of experimental measurements within 2% uncertainty. However 1D method showed a 3% discrepancy in small rectangular field for low energy electron beam. Conclusion : Emperical non-linear polynomial regressions of square root and 1D method were performed to determin the output factor in various field size and electron energy. The expected output of electron beam of square root method for square field and 1D method for rectangular field were very closed to that of measurement in all selected electron beam energy.

  • PDF

Dosimetric Characteristics of Edge $Detector^{TM}$ in Small Beam Dosimetry (소조사면 선량 계측을 위한 엣지검출기의 특성 분석)

  • Chang, Kyung-Hwan;Lee, Bo-Ram;Kim, You-Hyun;Choi, Kyoung-Sik;Lee, Jung-Seok;Park, Byung-Moon;Bae, Yong-Ki;Hong, Se-Mie;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.191-198
    • /
    • 2009
  • In this study, we evaluated an edge detector for small-beam dosimetry. We measured the dose linearity, dose rate dependence, output factor, beam profiles, and percentage depth dose using an edge detector (Model 1118 Edge) for 6-MV photon beams at different field sizes and depths. The obtained values were compared with those obtained using a standard volume ionization chamber (CC13) and photon diode detector (PFD). The dose linearity results for the three detectors showed good agreement within 1%. The edge detector had the best linearity of ${\pm}0.08%$. The edge detector and PFD showed little dose rate dependency throughout the range of 100~600 MU/min, while CC13 showed a significant discrepancy of approximately -5% at 100 MU/min. The output factors of the three detectors showed good agreement within 1% for the tested field sizes. However, the output factor of CC13 compared to the other two detectors had a maximum difference of 21% for small field sizes (${\sim}4{\times}4\;cm^2$). When analyzing the 20~80% penumbra, the penumbra measured using CC13 was approximately two times wider than that using the edge detector for all field sizes. The width measured using PFD was approximately 30% wider for all field sizes. Compared to the edge detector, the 10~90% penumbras measured using the CC13 and PFD were approximately 55% and 19% wider, respectively. The full width at half maximum (FWHM) of the edge detector was close to the real field size, while the other two detectors measured values that were 8~10% greater for all field sizes. Percentage depth doses measured by the three detectors corresponded to each other for small beams. Based on the results, we consider the edge detector as an appropriate small-beam detector, while CC13 and PFD can lead to some errors when used for small beam fields under $4{\times}4\;cm^2$.

  • PDF

A Comprehensive Computer Program for Monitor Unit Calculation and Beam Data Management: Independent Verification of Radiation Treatment Planning Systems (방사선치료계획시스템의 독립적 검증을 위한 선량 계산 및 빔데이터 관리 프로그램)

  • Kim, Hee-Jung;Park, Yang-Kyun;Park, Jong-Min;Choi, Chang-Heon;Kim, Jung-In;Lee, Sang-Won;Oh, Heon-Jin;Lim, Chun-Il;Kim, Il-Han;Ye, Sung-Joon
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.231-240
    • /
    • 2008
  • We developed a user-friendly program to independently verify monitor units (MUs) calculated by radiation treatment planning systems (RTPS), as well as to manage beam database in clinic. The off-axis factor, beam hardening effect, inhomogeneity correction, and the different depth correction were incorporated into the program algorithm to improve the accuracy in calculated MUs. A beam database in the program was supposed to use measured data from routine quality assurance (QA) processes for timely update. To enhance user's convenience, a graphic user interface (GUI) was developed by using Visual Basic for Application. In order to evaluate the accuracy of the program for various treatment conditions, the MU comparisons were made for 213 cases of phantom and for 108 cases of 17 patients treated by 3D conformal radiation therapy. The MUs calculated by the program and calculated by the RTPS showed a fair agreement within ${\pm}3%$ for the phantom and ${\pm}5%$ for the patient, except for the cases of extreme inhomogeneity. By using Visual Basic for Application and Microsoft Excel worksheet interface, the program can automatically generate beam data book for clinical reference and the comparison template for the beam data management. The program developed in this study can be used to verify the accuracy of RTPS for various treatment conditions and thus can be used as a tool of routine RTPS QA, as well as independent MU checks. In addition, its beam database management interface can update beam data periodically and thus can be used to monitor multiple beam databases efficiently.

  • PDF

A Rapid Analysis of 226Ra in Raw Materials and By-Products Using Gamma-ray Spectrometry (감마분광분석을 이용한 원료물질 및 공정부산물 중 226Ra 신속분석방법)

  • Lim, Chung-Sup;Chung, Kun-Ho;Kim, Chang-Jong;Ji, Young-Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.35-44
    • /
    • 2017
  • A gamma-ray peak of $^{226}Ra$ (186.2 keV) overlaps with one of $^{235}U$ (185.7 keV) in a gamma-ray spectrometry system. Though reference peaks of $^{235}U$ can be used to correct the peak interference of $^{235}U$ in the analysis of $^{226}Ra$, this requires a complicated calculation process and a high limit of quantitation. On the other hand, evaluating $^{226}Ra$ using the correction constant in the overlapped peak can make a rapid measurement of $^{226}Ra$ without the complicated calculation process as well as overcome the disadvantage in the indirect measurement of $^{214}Bi$, which means the confinement of $^{222}Rn$ gas in a sample container and a time period to recover the secular equilibrium. About 93 samples with 6 species for raw-materials and by-products were prepared to evaluate the activity of $^{226}Ra$ using the correction constant. The results were compared with the activity of $^{214}Bi$, which means the indirect measurement of $^{226}Ra$, to validate the method of the direct measurement of $^{226}Ra$ using the correction constant. The difference between the direct and indirect measurement of $^{226}Ra$ was generally below about ${\pm}20%$. However, in the case of the phospho gypsum, a large error of about 50% was found in the comparison results, which indicates the disequilibrium between $^{238}U$ and $^{226}Ra$ in the materials. Application results of the contribution ratio of $^{226}Ra$ were below about ${\pm}10%$. The direct measurement of $^{226}Ra$ using the correction constant can be an effective method for its rapid measurement of raw materials and by-products because the activity of $^{226}Ra$ can be produced with a simple calculation without the consideration of the integrity of a sample container and the time period to recover the secular equilibrium.

The Study on the Confidence Building for Evaluation Methods of a Fracture System and Its Hydraulic Conductivity (단열체계 및 수리전도도의 해석신뢰도 향상을 위한 평가방법 연구)

  • Cho Sung-Il;Kim Chun-Soo;Bae Dae-Seok;Kim Kyung-Su;Song Moo-Young
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.213-227
    • /
    • 2005
  • This study aims to assess the problems with investigation method and to suggest the complementary solutions by comparing the predicted data from surface investigation with the outcome data from underground cavern. In the study area, one(NE-1) of 6 fracture zones predicted during the surface investigation was only confirmed in underground caverns. Therefore, it is necessary to improve the confidence level for prediction. In this study, the fracture classification criteria was quantitatively suggested on the basis of the BHTV images of NE-1 fracture zone. The major orientation of background fractures in rock mass was changed at the depth of the storage cavern, the length and intensity were decreased. These characteristics result in the deviation of predieted predicted fracture properties and generate the investigation bias depending on the bore hole directions and investigated scales. The evaluation of hydraulic connectivity in the surface investigation stage needs to be analyze by the groundwater pressures and hydrochemical properties from the monitoring bore hole(s) equipped with a double completion or multi-packer system during the test bore hole is pumping or injecting. The hydraulic conductivities in geometric mean measured in the underground caverns are 2-3 times lower than those from the surface and furthermore the horizontal hydraulic conductivity in geometric mean is six times lower than the vertical one. To improve confidence level of the hydraulic conductivity, the orientation of test hole should be considered during the analysis of the hydraulic conductivity and the methodology of hydro-testing and interpretation should be based on the characteristics of rock mass and investigation purposes.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF