• Title/Summary/Keyword: 측정값

Search Result 14,436, Processing Time 0.042 seconds

Contrast Sensitivity as a Function of Spatial Frequency for 12 Year Old Child-Eye (눈의 공간주파수와 대비 민감도 함수(CSF) 특성에 대한 연구)

  • Kim, Yong Geun;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.63-68
    • /
    • 1999
  • It was made of a chart by new method to be measured the contrast sensitivity for a spatial frequency, and the mean luminance of a lattice frequency was made to three forms of 25, 50, 75% and let it to be ready a CS value from 0 to $10^3$. As a result of measuring of the CS value for a spatial frequency on a target of 12 year old students, CS value decreased of according to down the average luminance value and also the peak position shift to low spatial frequency. The low visioned person decreased the CS value in side of high frequency or in space of total frequency. By the lattice adaptation, a measured CS value was decreased in circumstance regions of adapted space frequency.

  • PDF

도핑하지 않은 다이아몬드 박막의 전기전도 경로와 기구

  • 이범주;안병태;백영준
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.60-60
    • /
    • 1999
  • 단결정 다이아몬드의 열전도도는 약 22W/cm.K로 열전도도가 가장 큰 물질로 알려져 있으며, 비저항은 10$\Omega$.cm 이상의 높은 값을 갖는다. 대부분 열전도도가 큰 것으로 알려진 물질들은 Cu, Ag 등과 같이 전자의 흐름에 의하여 열이 전도되기 때문에 큰 전기전도도를 함께 갖는 것일 일반적이다, 그러나, 다이아몬드는 빠른 phonon의 이동에 의하여 열전도가 이루어지므로 전기적으로 절연 특성을 갖으면서도 큰 열전도가 가능하다. 단결정 다이아몬드는 고방열 절연체로서 이상적인 물질 특성을 보여준다. 전기절연성을 갖는 열전도층으로 다이아몬드를 이용하기 위해서는 저가로 제조가 용이한 화학기상증착법을 이용하여야 한다. 화학기상증착법으로 제조된 다결정 다이아몬드 박막의 열전도도는 약 21W/cm.K로 여전히 매우 높은 값을 갖는 것으로 알려져 있지만, 비저항 값은 인위적으로 도핑을 전혀 하지 않은 상태에서도 106$\Omega$.cm 정도의 낮은 값을 갖는다. 전혀 도핑을 하지 않았음에도 전도성을 갖는 특이한 특성을 다결정 다이아몬드가 보여 주고 있으므로 이에 대한 연구는 주로 전기 전도성을 갖는 특이한 특성을 다결정 다이아몬드가 보여주고 있으므로 이에 대한 연구는 주로 전기전도성의 원인을 규명하는데 집중되고 있다. 아직 명확한 전도 기구는 제안되고 있지 못하지만 전도성의 원인은 수소와 관련이 있고 전도는 표면을 통하여 이루어진다는 것이다. 산(acid)을 이용하여 다결정 다이아몬드 박막을 세척하면 전기 전도성이 사라지고 높은 저항값을 갖는 박막을 얻게 되는데 박막을 세척하는 공정은 박막의 표면만을 변호시키므로 표면에 있던 전기전도층이 용액 처리를 통하여 제거되므로 전도성이 사라진다고 생각하는 것이다. 그러나, 본 연구에서는 두께가 두꺼울수록 저항값이 증가하는 것이 관찰되었고 기존의 측정방식인 수평적인 저항 측정법에 대하여 수직적 방향으로 저항을 측정하면 저항값이 1/2 정도 작게 측정되었다. 다결정 다이아몬드에서 표면을 통하여 전류가 흐른다면 박막의 두께에 따른 변화가 나타나지 않아야 하고 수직적인 전류 측정법이 오히려 더 큰 저항을 보여주어야 한다. 기존의 표면 전도 모델로는 설명되지 못하는 현상들이 관찰되었고 정확한 전기 전도 경로를 확인하기 위하여 전해 도금법으로 금속들이 석출되는 모습을 관찰하였다. 이 방법을 통하여 다결정 다이아몬드에서 전류는 결정입계를 통하여 전도됨을 알 수 있었다. 온도에 따른 다결정 다이아몬드의 전기전도도 변화를 관찰하였고 이로부터 활성화 에너지 값을 구할 수 있었다. 다결정 다이아몬드의 전도도는 온도에 따라서 0.049eV와 0.979eV의 두 개의 활성화 에너지를 갖는 구간으로 나뉘어졌다. 이로부터 다결정 다이아몬드에는 활성화 에너지 값이 다른 두 종류의 defect level이 형성되는 것으로 추정할 수 있고 이 낮은 defect level에 의하여 전도성을 갖는 것으로 생각된다.

  • PDF

The Usefulness Assessment of Verifying Daily Output by Using CHECKMATE$^{TM}$ (CHECKMATE$^{TM}$를 이용한 일일 출력 검증의 유용성 평가)

  • Cho, Han-Sang;Nam, Sang-Soo;Park, Hae-Jin;Kim, Mi-Hwa;Park, An-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Purpose: In this study, we tried to check the usefulness of two Linear Accelerators, Clinac IX and 21EX (Varian, Palo Alto, CA), which are equipped in Ajou Medical Center. From 2008 to 2010, we evaluated the error range of Absolute Dose based on the daily output, which was measured by CHECKMATE$^{TM}$ (Sun Nuclear, Melbourne, FL). Materials and Methods: For Daily Q.A, photon beams of two linear accelerators, 21EX and IX (6 MV and 10 MV, respectively) were measured daily by using CHECKMATE$^{TM}$ just before the treatment began, while the absolute dose was measured biweekly by using water phantom. We analyzed the data of measured values from the daily Q.A and the absolute dose from 2008 to 2010 for 21EX, and from 2009 to 2010 for IX. We utilized Excel 2007 (Microsoft, USA) to evaluate Average, Standard deviation and Confidence level of the data. Furthermore, in order to check the measured values of CHECKMATE$^{TM}$ and the significance of absolute dose, each error value was compared and analyzed. Results: During the observation period, the output of two equipment's absolute dose increased in process of time and in both 6 MV and 10 MV, there was a similar increasing trend. In addition, the error rate of the measured value of CHECKMATE$^{TM}$ and the value of absolute dose were under 0.34, which means that there is a similarity relationship between the two measured values. After checking that the measured value of CHECKMATE$^{TM}$ increased, We measured the absolute dose to adjust that. When the error range was close to 2~3%, the number of changing the output was four for 21EX and three for IX. Conclusion: As a result of measuring and analyzing the daily output changes for two years by using CHECKMATE$^{TM}$, we could find that there is a significance between the output which we should obey during Q.A, and the measured value of absolute dose within the error tolerance of 2~3%. Thus, the use of CHECKMATE$^{TM}$ can be positively considered for more efficient and reliable daily output verification of linear accelerator. It can also be a good standard for other medical centers to understand the trends of linear accelerator and to refer to for the correction of each output.

  • PDF

A study on the measurement conditions for measuring the toughness of bread (식빵의 굳기 측정을 위한 측정 조건에 관한 연구)

  • Shin, Sun-Hwa;Choi, Won-Seok
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.247-250
    • /
    • 2022
  • The maximum cutting force (MCF) was measured and analyzed under various conditions using a Miller/Hoseney toughness rig to measure the toughness of bread due to aging. In the bread crust, the MCF increased significantly as the cross-head speed increased, and different type of significant difference between the samples were observed under some measurement conditions (p<0.05). Within the bread, the MCF increased significantly as the cross-head speed increased at the same penetration ratio, and the significant differences between the samples did not change even if the cross-head speed changed regardless of the penetration ratio. In conclusion, when using this method to measure the toughness of bread (apart from the crust), the MCF varied with the changing measurement conditions; however, the significant difference between the samples did not change. Thus, MCF can be considered a useful and reliable parameter when measuring the difference between the samples.

Computer Vision-Based Measurement Method for Wire Harness Defect Classification

  • Yun Jung Hong;Geon Lee;Jiyoung Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2024
  • In this paper, we propose a method for accurately and rapidly detecting defects in wire harnesses by utilizing computer vision to calculate six crucial measurement values: the length of crimped terminals, the dimensions (width) of terminal ends, and the width of crimped sections (wire and core portions). We employ Harris corner detection to locate object positions from two types of data. Additionally, we generate reference points for extracting measurement values by utilizing features specific to each measurement area and exploiting the contrast in shading between the background and objects, thus reflecting the slope of each sample. Subsequently, we introduce a method using the Euclidean distance and correction coefficients to predict values, allowing for the prediction of measurements regardless of changes in the wire's position. We achieve high accuracy for each measurement type, 99.1%, 98.7%, 92.6%, 92.5%, 99.9%, and 99.7%, achieving outstanding overall average accuracy of 97% across all measurements. This inspection method not only addresses the limitations of conventional visual inspections but also yields excellent results with a small amount of data. Moreover, relying solely on image processing, it is expected to be more cost-effective and applicable with less data compared to deep learning methods.

Effect of Die Attach Process Variation on LED Device Thermal Resistance Property (Die attach 공정조건에 따른 LED 소자의 열 저항 특성 변화)

  • Song, Hye-Jeong;Cho, Hyun-Min;Lee, Seung-Ik;Lee, Cheol-Kyun;Shin, Mu-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.390-391
    • /
    • 2007
  • LED Packaging 과정 중 Die bond 재료로 Silver epoxy를 사용하여 Packaging 한 후 T3Ster 장비로 열 저항 값(Rth)을 측정하였다. Silver epoxy 의 접착 두께를 조절하여 열 저항 값을 측정하였고, 열전도도 값이 다른 Silver epoxy를 사용하여 열 저항 값을 측정하였다. Silver epoxy 접착 두께가 충분하여 Chip 전면에 고루 분포되었을 경우 그렇지 않은 경우보다 평균 4.8K/W 낮은 13.23K/W의 열 저항 값을 나타내었고, 열전도도가 높은 Silver epoxy 일수록 열전도도가 낮은 재료보다 평균 4.1K/W 낮은 12K/W의 열 저항 값을 나타내었다.

  • PDF

Evaluation of Dosimetric Leaf Gap (DLG) at Different Depths for Dynamic IMRT (동적 세기조절방사선치료에서 깊이에 따른 DLG변화 분석)

  • Chang, Kyung Hwan;Kwak, Jungwon;Cho, Byungchul;Jeong, Chiyoung;Bae, Jae Beom;Yoon, Sang Min;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.153-159
    • /
    • 2015
  • This study is to evaluate thedosiemtric leaf gap (DLG) at different depths for dynamic intensity-modulated radiation therapy (IMRT) in order to evaluate the absolute dose and dose distribution according to the different positions of tumors and compare the measured and planned the multileaf collimator (MLC) transmission factor (T.F.) and DLG values. We used the 6 MV and 15 MV photon beam from linear accelerator with a Millenium 120 MLC system. After the import the DICOM RT files, we measured the absolute dose at different depths (2 cm, 5 cm, 10 cm, and 15 cm) to calculate the MLC T. F. and DLG. For 6 MV photon beam, the measured both MLC T. F. and DLG were increased with the increase the measured depths. When applying to treatment planning systemas fixed transmission factor with its value measured under the reference condition at depth of 5 cm, although the difference fixed and varied transmission factor is not significant, the dosiemtric effect could be presented according to the depth that the tumor is placed. Therefore, we are planning to investigate the treatment planning system whichthe T. F. and DLG factor according to at the different depths can be applied in the patient-specific treatment plan.

An Analysis of Power Dissipation of Value Prediction in Superscalar Processors (슈퍼스칼라 프로세서에서의 값 예측의 전력 소모 측정 및 분석)

  • 이명근;이상정
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10c
    • /
    • pp.688-690
    • /
    • 2002
  • 고성능 슈퍼스칼라 프로세서에서는 명령어 수준 병렬성(Instruction Level Parallelism, ILP)의 장애인 명령어간의 종속 관계 중 데이터 종속관계를 극복하기 위해 값 예측기를 이용하여 모험적으로 명령어들을 실행한다. 값 예측 시에 필요한 테이블 참조와 값 예측 실패 시 실행되는 잘못된 명령어의 실행은 프로세서의 부가적인 전력 소모를 요구한다. 본 논문에서는 값 예측기와 Cai-Lim의 전력모델을 슈퍼스칼라 프로세서 사이클 수준 시뮬레이터인 SimpleScalar 3.0 툴셋에 삽입하여 전력 소모량을 측정하고 분석한다.

  • PDF

The dynamic measured vibration and shock acceleration of an electrical equipments for transported by road vehicles (차량수송에 의한 전기기기의 진동과 충격가속도 실측)

  • Kim, Myoung-Seok;Oh, Joon-Sick;Han, Gyu-Hwan;Park, Joong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.93-94
    • /
    • 2007
  • 운송 중에 발생되는 진동, 충격이 전기기기에 미치는 영향을 검증하기 위해 측정자료를 바탕으로 실험실에서 보리 실험한 수 있는 실험기준을 설정할 필요가 있다. 이를 위해 측정절차를 수립하고 발생요인에 따른 실측자료를 확보하기 위해 진동과 충격을 측정하는 시스템을 개발하였다. 측정결과 운송 도로면의 요철조건, 운송차종(중량), 운송속도에 따라 측정값에 차이가 있었다. 세부적으로 콘크리트 도로, 고속 주행일 때, 파워스펙트럼밀도(PSD) 값이 큰 것으로 분석되었고, 충격가속도는 소형 트럭이 가장 큰 값으로 분석되었다. 또한 측정자료를 바탕으로 랜덤진동시험기준을 제시하였다.

  • PDF

Theoretical Calibration of the Composition of Multicomponent Thin Film Obtained by Wavelength Dispersive Spectroscopy (WDS로 측정한 다성분계 박막 조성의 이론적인 보정)

  • Byeon, Gyeong-Mun;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.7 no.7
    • /
    • pp.597-603
    • /
    • 1997
  • 파장분산 분광분석기(Wavelength Dispersive Spectroscopy, WDS)는 다른 분석 방법에 비해 분해능이 좋고 측정 시간이 적게 걸리며, 또한 비용면에서 경제적이고 정량값이 실제값과 다르게 측정될 수 있다. 즉, 다성분계 박막에 있엇 X-선 발생 깊이가 작은 원소의 경우 X-선 발생 깊이가 큰 원소에 비해 조성값이 과장되어 측정된다. PZT박막의 경우에도 WDS로 측정한 조성은 박막의 두께에 따른 정확한 보정이 필요하다. 본 연구에서는 WDS를 이용하여 PZT박막의 조성을 측정할 때, 얇은 박막의 경우에도 조성을 정확하게 알아낼 수 있도록 박막의 두께에 따른 조성의 보정법을 제시하였다. 또한, 박막의 두께를 직접 측정하는 과정없이 WDS분석 결과로 얻는 각 원소들의 [ZAF]k 의 합으로부터 박막의 두께를 이론적으로 구하였으며, 이를 실험값과 비교하였다.

  • PDF