• Title/Summary/Keyword: 측정(measurement)

Search Result 20,200, Processing Time 0.041 seconds

On the measurement of characteristics of antennas for indoor digital TV (실내 디지털 TV용 안테나 특성 측정에 관하여)

  • Park, Jin-Taek;Lee, Jong-Ig;Yeo, Junho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2345-2350
    • /
    • 2014
  • In this paper, measurement methods for the characteristics of antennas for indoor digital TV (DTV), having 75-ohm port impedance, are introduced. Reference impedance of typical radio frequency (or microwave) systems and measurement equipments is 50 ohm. However, the reference impedance of antennas for indoor DTV is 75 ohm, and the characteristics of the antennas cannot be measured directly using the measurement equipments. Measurement methods, using test equipments with reference impedance of 50 ohm, for the characteristics(impedance, radiation patterns, and gain) of antennas designed to fit for 75 ohm port are introduced.

A Study on the Shape Measurement of Glass in the Back Light Unit(BLU) (BLU의 Glass 형상 측정 연구)

  • Oh, Choonsuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.211-218
    • /
    • 2019
  • All display devices require more wider, higher resolution and precision owing to advanced display technology. As the display pannels become wider, BLU also become wider and brighter. The upper glass of the BLU must achieve the constant of its shape and thickness and have uniform brightness. These deformity cause the display quality to make less. Thus high performance of the BLU shape's height and thickness measurement is inevitable. The high speed and precision measurement system will be proposed. To minimize the measurement error we can achieve the desirous results by 2 dividing intervals with different moving velocity on measuring.

A Study on the Reasonable Measurement Point of Root Collar Diameter of Landscape Trees in Korea (한국 조경수목 근원직경 측정의 합리적 위치 설정에 대한 연구)

  • Han, Yong-Hee;Kim, Hwa-Jeong;Kim, Do-Gyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.59-70
    • /
    • 2021
  • This study was to investigate the measurement point of root collar diameter of landscape trees in Korea. It may contribute to avoiding disputes caused by the difference in measurement criteria of root collar diameter of landscape trees between tree growers and constructors. The difference between landscape trees' root collar diameter measurement point was 3.59cm from 6cm underground to the surface and 1.35cm from 0cm to 6cm above ground. The source root collar diameter measurement point difference was larger in the basement than in the ground. The standard deviation of the root collar diameter of the landscape tree was 0.64 from 6cm underground to the surface, and the difference in standard deviation from 0cm to 6cm above ground was 0.16. The difference by measurement point of the root collar diameter was larger in the basement than in the ground. It has been proposed to set the reasonable measurement point of the landscaping tree root collar diameter at the inflection point where the standard deviation of the tree trunk diameter is the smallest in line with the size change of the standard for each root collar diameter measurement point. By tree species, Cornus officinalis Siebold & Zucc. 18cm above the ground, Chionanthus retusus Lindl. & Paxton. 12cm above the ground, Zelkova serrata (Thunb.) Makino. 12cm above the ground, Celtis sinensis Pers. 12cm above the ground, Styrax japonicus Siebold & Zucc. 10 cm above the ground, Cornus officinalis Siebold & Zucc. 10cm above the ground, Acer palmatum Thunb. ex Murray. 6cm above the ground, Ilex rotunda Thunb. 6cm above the ground, Quercus myrsmaefolia Blume. 4cm above the ground, Lagerstroemia indica L. 2cm above the ground The above heights were shown as reasonable measurement points. The difference by landscape tree root collar diameter measurement site showed that the standard deviation was small throughout the tree species, and the reasonable average measurement point with a stable slope of the deviation was 12cm or more on average. It can be said that the reasonable measurement point of the root collar diameter of a landscape tree is set at an average of 12cm above the ground. However, recognizing 30cm, which is a familiar ruler(尺) in traditional practices, is quick, It was recommended to measure at the height of 30cm from the surface for a reasonable measurement point of the root collar diameter of a landscape tree, for the uniformity of measurement standards.

Measurement Uncertainty for Calibration of EMI Dipole Antenna from 30 MHz to 1 GHz (30 MHz에서 1 GHz 대역 EMI 측정용 다이폴안테나 교정의 측정 불확도)

  • Park, Jung-Kuy;Jeong, Dong-Chan;Cho, Jin-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.166-176
    • /
    • 2007
  • Measurement uncertainty assessment is very important in measurement and calibration. RRL provides antenna calibration services for EMI test. Reliability of EMI test depends on accurate antenna calibration. Antenna calibration results have to be accompanied with measurement uncertainty for its better reliability. In the late of 2005, CISPR issued the CISPR/A/644/C which describes the antenna calibration and measurement uncertainty. In this paper, on the basis of CISPR/A/644/C, we provide the measurement uncertainty values for dipole antenna calibration at the Calibration Test Site(CALTS) of Icheon. The antenna calibration method is 3-antenna height-scanning-averaging method, which measures the free-space antenna factor. We also considered all uncertainty sources that can affect measurement results during calibration.

The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester (MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템)

  • Ra-Yun Boo;Jung-Hun Choi;Myung-Eui Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.203-208
    • /
    • 2023
  • In this study, we propose a method to improve the precision of contact resistance measurement circuits using constant current method and voltage drop method, and implement a dashboard that monitors the measured data of contact resistance measurement systems through MQTT broker server. The contact resistance measurement system measures the resistance value and transmits the measured value to the MQTT broker server using wireless communications. This developed dashboard uses Node-RED and Node-RED-Dashboard to receive the resistance values of up to four contact resistance measurement systems and show them to user's monitor screen. Users can manage multiple measurement data using a single dashboard and easily interface with other devices through the MQTT broker server. Through the experimental results from real data measurements, the relative standard deviation about precision is improved to average 40.37% and maximum 64.73% respectively.

Photo Sensor Based Measurement and Noise Reduction of Dynamic Weights (광 센서에 기반한 동하중의 측정 및 잡음 감소)

  • Shin, Dae-Jung;Na, Seung-You;Kim, Jin-Young
    • The KIPS Transactions:PartC
    • /
    • v.12C no.4 s.100
    • /
    • pp.519-524
    • /
    • 2005
  • Due to various types of errors added to dynamic weight measurement data, proper methods to reduce measurement errors are required to produce reliable weights. It is very difficult to reduce the measurement error due to excessive oscillation of the system. To cope with parasitic types of errors in real systems, information provided by the photo sensors are utilized and combined in such a way to reduce the measurement errors of load cells. In addition to four channels of load cells from a model trailer, photo sensors are used to obtain the information to compensate the error induced from vertical movement of the vehicle due to the variation of ground level. A model trailer system is run to verify the effectiveness of the proposed method to reduce noise of dynamic weight measurements.

Range Alignment Measurement for Satellite Antenna by Using Theodolite System (데오드라이트 시스템을 이용한 위성 안테나 레인지 얼라인먼트 측정)

  • Park, Hong-Cheol;Son, Yeong-Seon;Yun, Yong-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.134-141
    • /
    • 2004
  • The three-dimensional precision measurement technology for industrial product of middle and/or large scale has been developed. Theodolite measurement system which is one of the technology is widely used in aerospace industry. This paper describes a range alignment method of parabolic antenna to RF probe in the near field range by using the theodolite system, The range alignments of the Ku-band and Ka-band antennas have been accomplished within the requirements, ${\pm}1mm\;and\;{\pm}0.05^{\circ}$.

A Designing Method of Network Quality Assurance Test Bed Design under Next-generation Network Environment (NGN(Next Generation Network)의 네트워크 품질 보증을 위한 테스트베드 모델 설계)

  • Chung, Ji Moon
    • Journal of Digital Contents Society
    • /
    • v.13 no.4
    • /
    • pp.625-629
    • /
    • 2012
  • This paper is presented to prepare NGN quality assurance management process under the quality system test methodology. The process should be drawn for NGN quality measurement framework of multimedia traffic. NGN test bed management process model are QoS measurement metrics, measurement interval meter above, and measuring tools, measuring equipment, measurement methods and measurement results from a series of processes for the analysis and methodology. This model, NGN quality assurance activities should be utilized in the future. Quality target level only when themselves constantly measured and managed, does not guarantee the communication quality of service. It is sensitive to the importance of NGN network technology paradigm for research on quality management in the NGN.

Calibration Techniques for Low-Level Current Measurement in the Characteristic Analysis System for Semiconductor Devices (저전류 측정을 위한 반도체 소자 특성 분석 시스템에서의 보상 기법)

  • Choi, In-Kyu;Park, Jong-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2002
  • In this paper, we proposed calibration techniques to improve measurement accuracy in the characteristic analysis system for semiconductor devices. Systematic errors can be reduced using proposed calibration techniques. Also, error current reduction procedures including leakage current and offset current are proposed to measure low-level current in pA level. Calibration parameters are calculated and stored by microprocessor using least-square fitting with measured sample data. During measurement time microprocessor corrects measured data using stored calibration parameters. Experimental results show that current measurement error above nA level is less than 0.02%. And they also show that current measurement in pA level can be performed with about 0.2% accuracy.

W-Band Permittivity Measurements Using a Free-Space Material Measurement Technique (자유공간 물질상수 측정법을 이용한 W-Band 유전율 측정)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Cho, Chihyun;Kim, Dae-Chan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.3
    • /
    • pp.253-258
    • /
    • 2013
  • In this paper, a free-space material measurement technique is discussed in W-band(75~110 GHz). For the accurate measurement of S-parameters of an MUT(Material Under Test) in free space, a W-band quasi-optical free-space material measurement system, less affected by the measurement environments, is discussed, and GRL(Gated Reflect Line) method for calibrating the measurement system is described. Proposed technique is verified for 'Air' and measurement results for arystal plates of thickness 1.1 mm, 2 mm, 2.75 mm and 5 mm are also shown.