• Title/Summary/Keyword: 측과

Search Result 5,062, Processing Time 0.043 seconds

A STUDY ON PROFILE CHANGE OF SKELETAL CLASS III MALOCCLUSION PATIENTS AFTER WEARING PROTRACTION HEAD GEAR (골격성 제III급 부정교합 환자에서 상악골 전방견인장치 사용후 측모 변화에 대한 연구)

  • Lim, Joong-Ki;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.375-401
    • /
    • 1995
  • Cause of skeletal Class III malocclusion in growing patients can be classified into maxillary deficiency, mandibular overgrowth, and combination of the two. Use of Protraction Head Gear(P.H.G.) has been recommended for treatment of growing Class III malocclusion patients, for it results in forward & downward movement of maxilla and backward & downward rotation of mandible. Numerous animal experiments were performed and clinical study data have been reported ; nevertheless, studies on soft tissue profile change and comparison of treatment effects among the patients who had undergone treatment are considered to be somewhat insufficient. The author selected 93 patients, who had been diagnosed as skeletal Class III malocclusion with maxillary deficiency and then treated with P.H.G. ; the sample group was divided according to sex, treatment beginning age, palatal suture opening(intraoral appliance), and facial growth pattern. For each group, changing patterns of hard and soft tissue profile observed, and comparision with 20 normal group(Angle's Class I) patients of statistical significance in amount of growth and treatment of hard and soft tissue was done. The following results were obtained. 1. Skeletal, dental, and soft tissue measurements indicated that more growth changes was induced in the sample group that used P.H.G. compared to the growth amount of normal group. 2. No statistical significance was observed in the amounts of maxillary forward movement and mandibular backward & downward rotation depending on treatment beginning age in both sex group. 3. R.P.E. showed more significant maxillary forward movement and less protrusion of upper incisor than La-Li. 4. There was no statistical significance in the amount of maxillary forward movement depending on facial growth pattern. On the other hand, measurements indicating mandibular downward & backward rotation indicated greater change in counterclockwise growth pattern group than the clockwise. 5. Changes in upper and lower lip thicknesses showed a close relationship with positional changes in underlying bone tissue and upper and lower teeth, and upper lip height and nasolabial angle increased and mentolabial angle decreased.

  • PDF

Change in tooth length and angulation on panoramic radiographs taken at different labiolingual and buccolingual inclinations (치아의 순(협)설 경사도 변화에 따라 파노라마 방사선 사진에 나타난 치아 길이 및 각도 변화)

  • Choi, Gab-Lim;Lim, Sung-Hoon;Kim, Jae-Duck;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.114-124
    • /
    • 2007
  • Objective: The purpose of this study was to examine how the mesio-distal angulation and the length of each tooth changes on panoramic radiograph at different bucco-lingual inclinations. Methods: After constructing an acrylic model based on the mean arch of 30 adults with normal occlusion, the wire was placed in the center of the teeth on the acrylic model. First, the wire was implanted in normal angulation and inclination and a panoramic radiograph taken. After changing the inclination from $I-5^{\circ}\;to\;I+15^{\circ}\;by\;5^{\circ}$, a panoramic radiograph was taken again and the mesio-distal angle and wire length on the panoramic radiograph were assessed. Results: When the wire was implanted at the normal angulation and inclination, the length measured in the panoramic radiograph was magnified $111{\sim}117%$ from the original length in the anterior region and $121{\sim}125%$ in the posterior region. Only the central and lateral incisors showed significant length differences when the inclination was changed from $l-15^{\circ}\;to\;I+15^{\circ}$ at fixed angulation. When the inclination was changed from $l-15^{\circ}\;to\;I+15^{\circ}$, the angulation of most teeth on panoramic radiograph appeared to be more disto-angulated than in reality, and the lateral incisor and canine showed the largest difference. Only $l-15^{\circ}\;to\;I+15^{\circ}$ groups of premolars and $I+15^{\circ}$ group of molars showed more mesio-angulation than in reality. As the labio(bucco)lingual inclination of all teeth were decreased, tooth angulation in the panoramic radiograph appeared to be more disto-angulated. Conclusion: The labio-liugual inclination of teeth should be considered because it affects panoramic image of teeth, such as length of incisors and angulation of other teeth.

Effects of Oral Parafunction on the Stiffness and Elasticity in the Muscles of the Mastication and Facial Expression (구강악습관이 저작근 및 안면표정근의 경직도 및 탄성도에 미치는 영향)

  • Kim, Seung-Ki;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.1
    • /
    • pp.85-95
    • /
    • 2008
  • The purpose of this study was to evaluate the effects of oral habits on the muscles of mastication and facial expression by means of two parameters: muscle stiffness and elasticity. 10 healthy, fully-dentate male subjects in their twenties were selected for this study; all had normal Class I occlusal relationships. Muscle stiffness and elasticity were measured with a tactile sensor(Venustron, Axiom Co., JAPAN) while subjects were asked to relax and perform various parafunctional activities such unilateral clenching(biting the bite force recorder with a force of 50kg on each subject's preferred side), jaw thrusting and lip bracing. The following muscles were examined: temporalis anterior(Ta), masseter(Mm), frontalis(Fr), inferior orbicularis oculi(OOci), zygomaticus major(Zm), superior and inferior orbularis oris(OOrs and OOri) and mentalis(Mn). Paired t-test, Correlation Coefficients, ANOVA and Multiple Comparison t-tests were used for statistical analysis. Unilateral clenching was highly correlated with bilateral stiffness and elasticity of all the muscles tested. Mm was affected by all three oral habits; Ta was affected by unilateral clenching(p<0.05); Zm was affected by unilateral clenching and OOrs, OOri and Mn were most affected by lip bracing(p<0.05). This study indicates that not only the masticatory muscles but also the muscles of facial expression, mainly circumoral muscles, can be significantly influenced by parafunctional activities such as unilateral clenching and lip bracing.

In vitro study of microleakage of endodontically treated teeth restored with different adhesive systems and fiber-reinforced posts (다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 미세누출에 관한 연구)

  • Park, Joon-Ho;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.74-81
    • /
    • 2014
  • Purpose: While studies have examined microleakage in endodontically treated teeth restored with posts, microleakage among post and adhesive systems remains a concern. This study compared the sealing properties of 3 adhesively luted post systems. Materials and methods: Thirty-six endodontically treated permanent maxillary central incisors were divided into 3 groups: Zirconia-glass fiber, Quartz-glass fiber, Polyethylene fiber posts. Post space was prepared and each post was adhesively luted with 3 systems. The specimens were separately immersed in freshly prepared 2% methylene blue solution for 1 week. The cleaned specimens were then embedded in autopolymerizing acrylic resin. The root portion of tooth were horizontally sectioned into three pieces (apical, middle, and coronal portions). An occlusal view of each section was digitally photographed with a stereomicroscope. The methylene blue-infiltrated surface for each specimen was measured. Dye penetration was estimated as the ratio of the methylene blue-infiltrated surface to the total dentin surface. Results: No significant differences were found among post types. The variables of middle section and 3-stage adhesive produced significant differences in microleakage between the following post pairs: zirconia-glass fiber versus quartz-glass fiber, zirconia-glass fiber versus polyethylene fiber, and quartz-glass fiber versus polyethylene fiber (P<.05). There were significant differences between the apical and coronal sections of each post type, and between apical versus middle sections of quarze-glass fiber and polyethylene fiber posts (P<.05). Conclusion: No significant differences were found among post types. The 3-stage adhesive produced significant differences in microleakage between the following post pairs.

A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER (3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구)

  • Lee, Jong-Beom;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.643-652
    • /
    • 2006
  • The purpose of this study was to elucidate the size and morphologic characteristics of maxillary primary first molars in Korean children using three-dimensional laser scanner and compare three-dimensional image with preformed stainless steel crown. Scanned three-dimensional images of dental cast taken from 132 children(male 62, female 70) by three-dimensional laser scanner(Breuckmann opto-Top HE100, INUS, Korea) were used. Mesiodistal diameter, buccolingual diameter, occlusogingival height and crown shape of each image were calculated by Rapidform 2004 program(INUS, Korea). The values were statistically compared by independent samples t-test with 95% of significant level. The results were as follows : 1. No significant difference in crown size was found between left and right maxillay primary first molar(p>0.05). 2, Significant difference in mesiodistal diameter, buccolingual diameter, buccal occlusogingival height was found between male and female (p<0.05), and crown size of male was bigger than that of female. 3. Average image of maxillay primary first molar was shaped three-dimensionally and measured. In comparison with 3M stainless steel crown, this image was similar with No.4 or No.5 SS crown in male, No.4 in female. In comparison with ILSUNG SS crown, this image was similar with No.5 in male, No.4 in female. 4 Mesiolingual line angle area, distolingual line angle area and buccogingival ridge were more obvious in average image than 3M stainless steel crown. ILSUNG SS crown was more square and had longer mesiodistal diameter than average 3D image.

  • PDF

THE EFFECT OF ETCHING TIME ON THE PATTERN OF ACID ETCHING ON THE ENAMEL OF PRIMARY TEETH (산부식 시간에 따른 유전치 법랑질의 부식 유형에 관한 연구)

  • Choi, Su-Mi;Choi, Young-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.437-445
    • /
    • 2008
  • The presence of a "prismless" layer on the enamel surface particularly on deciduous teeth has been reported by a number of workers. This structure, which appears to lack the normal prism delineations, could interfere with tag formation and hence, reduce bonding to such surfaces. The purpose of this study was to investigate the relationship of etching times on the effect of acid etching on primary enamel with respect to the quality of etching patterns. Labial surfaces of 32 extracted or exfoliated caries-free primary anterior teeth were used. 35% phosphoric acid gel was used only cervical regions of labial surfaces for each etching time group, 15, 30, 45 and 60 seconds. The surfaces were then washed with water for 20 seconds and dried with air spray for 20 seconds. 1. The Type 3 is 75% when the 15 seconds acid etching time was used. 2. The Type 1 is 38% and Type 2 is 75% when the 30 and 45 seconds acid etching time was used. 3. The Type 1 is 25% and Type 2 is 75% when the 60 seconds acid etching time was used. 4. An etching time of 60 seconds produced a constant and regular etching pattern. 5. There is a significant difference between the groups with respect to the patterns of etch achieved(p<0.05). 6. We confirmed that the acid induced patterns(type 1, 2) became more pronounced when the application time increased(p<0.05). $45{\sim}60$ seconds was the optimal time for etching on the primary enamel.

  • PDF

Determination of Adsorption Isotherms of Hydrogen at an Ir Electrode Interface Using the Phase-Shift Method and Correlation Constants (Ir 전극 계면에서 위상이동 방법 및 상관계수를 이용한 수소의 흡착동온식 결정)

  • Jeon, Sang-K.
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.132-140
    • /
    • 2007
  • The phase-shift method and correlation constants for studying a linear relationship between the behavior ($-{\varphi}\;vs.\;E$) of the phase shift ($0^{\circ}{\leq}-{\varphi}{\leq}90^{\circ}$) for the optimum intermediate frequency and that (${\theta}\;vs.\;E$) of the fractional surface coverage ($1{\geq}\theta{\geq}0$) have been proposed and verified to determine the Langmuir, Frumkin, and Temkin adsorption isotherms (${\theta}\;vs.\;E$) at noble metal/aqueous electrolyte interfaces. At an Ir/0.1 M KOH aqueous electrolyte interface, the Langmuir and Temkin adsorption isotherms (${\theta}\;vs.\;E$), equilibrium constants ($K=3.3{\times}10^{-4}\;mol^{-1}$ for the Langmuir and $K=3.3{\times}10^{-3}{\exp}(-4.6{\theta})\;mol^{-1}$ for the Temkin adsorption isotherm), interaction parameter (g = 4.6 for the Temkin adsorption isotherm), and standard free energies (${\Delta}G_{ads}^0=19.9kJ\;mol^{-1}\;for\;K=3.3{\times}10^{-4}\;mol^{-1}$ and $16.5<{\Delta}G_{\theta}^0<23.3\;kJ\;mol^{-1}\;for\;K=3.3{\times}10^{-3}{\exp}(-4.6{\theta})\;mol^{-1}\;and\;0.2<\theta<0.8$) of H for the cathodic $H_2$ evolution reaction are determined using the phase-shift method and correlation constants. The inhomogeneous and lateral interaction effects on the adsorption of H are negligible. At the intermediate values of ${\theta},\;i.e,\;0.2<{\theta}<0.8$, the Temkin adsorption isotherm (${\theta}\;vs.\;E$) correlating with the Langmuir or the Frumkin adsorption isotherm (${\theta}\;vs.\;E$), and vice versa, is readily determined using the correlation constants. The phase-shift method and correlation constants are accurate and reliable techniques to determine the adsorption isotherms (${\theta}\;vs.\;E$) and related electrode kinetic and thermodynamic parameters(K, g, ${\Delta}G_{ads}^0, {\Delta}G_{\theta}^0$).

The Application of B-Type Natriuretic Peptide Level of the Dyspneic Patients : Differentiation Between Cor Pulmonale and Left Ventricular Dysfunction (호흡곤란을 주소로 내원한 환자에서 혈청 B-type Natriuretic Peptide 검사의 유용성 : 폐성심과 좌심부전의 감별에 대하여)

  • Park, Hong-Hoon;Kim, Sehyun;Choi, Jeongeun;Kim, Kang-Ho;Cheon, Seok-Cheol;Lee, Jihyun;Lee, Yong-Gu;Kim, In-Jae;Cha, Dong-Hoon;Hong, Sang-Bum;Lee, Ji-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.320-329
    • /
    • 2003
  • Background : The serum B-type natriuretic peptide (BNP) is released from the ventricles as a response to volume or pressure overload of the ventricles. A few studies have reported that the BNP measurements are useful in differentiating between heart failure and pulmonary causes in patients who visited the emergency department with dyspnea as the chief complaint. It is difficult to differentiate a right heart failure from a left heart failure in the emergency room. However, there is no report on the application of a BNP assay to differentiate in right heart failure from left heart failure. In this study, the BNP levels were measured from dyspneic patients in the emergency department to determine whether or not the BNP level would be useful in differentiating the cause of the dyspnea from right ventricular failure and left ventricular failure. Method : 89 patients who visited emergency department of the Bundang Cha Hospital with dyspnea from June 2002 to March 2003 were selected. The 29 patients from the outpatient clinics and inpatients were randomly selected as the control. Results : The BNP levels of patients in the left heart failure group were significantly different from that of the patients in the right heart failure group ($682{\pm}314$ pg/mL vs. $149{\pm}94$ pg/mL, p=0.000). When the BNP cut-off level was designated as 219 pg/mL using the receiver operating characteristic curve, the sensitivity was 94.3%, and specificity was 92.9%. In addition, the positive predictive value was 97% and the negative predictive value was 86.7% in differentiating right heart failure from left heart failure. Conclusion : Measurements of the serum BNP levels is an accurate and rapid method that can aid in distinguishing between right heart failure and left heart failure.

Functional Outcomes of Internal Pelvectomy without Reconstruction for Periacetabular Maligmant Tumors (비구주변 골반골 악성 골종양에서 재건술을 시행하지 않은 내골반골 절제술의 기능적 결과)

  • Chung, Yang-Guk;Kang, Yong-Koo;Lee, Seung-Koo;Bahk, Won-Jong;Lee, An-Hi;Park, Jung-Mi;Lee, Kyo-Sun;Lee, Hyung-Ju
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.60-66
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the functional outcomes of periacetabular malignant bone tumors treated by internal pelvectomy without reconstruction. Materials and methods: Between January 1996 and December 2005, eight patients with primary malignant or metastatic periacetabular bone tumors were treated by internal pelvectomy without reconstruction. There were 6 men and 2 women. Mean age was 42 years old. There were 3 osteosarcomas, 3 chondrosarcomas and 2 metastatic carcinomas. The type of pelvic resections were 6 type I+II+III, 1 type I+II and 1 type II+II resection. The functional outcomes were evaluated with ISOLS revised criteria. The follow up period ranged from 6 to 84 months. Results: At last follow up, 5 patients showed CDF, 2 patients, AWD and the remained 1, DOD. The mean functional score for pain, functional activity, emotional acceptance, use of external support, walking ability and gait were 4.9, 2.9, 2.9, 1.5, 2.3 and 2.5 respectively. The total functional score ranged from 37% to 70%(average: 56%). There were three temporary nerve palsies. Conclusion: The internal pelvectomy without reconstruction for selective difficult periacetabular malignant tumors could be a viable option with fewer complications and fair functional outcomes.

  • PDF

Dispersion Effect Based on Irradiation Dose and Position of QRD Microwave in Sealed Chamber (밀폐된 챔버의 QRD 마이크로파 조사용량과 위치에 따른 분산효과)

  • Kim, Jin Hyun;Han, Chung Su;Lee, Keun Woo;Lim, Kyoung Ho;Lee, Jae Hyun;Kim, Kyung Min;Ha, Yu Shin
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • This study analyzed the efficiency and uniformity by measuring the temperature change depending on the position in the chamber with the use of QRD (quadratic residue diffusor) microwave capable of inducing even sterilization by changing wavelength phase difference and enhancing the effect on low power. The results are summarized as follows: When irradiating 7 kW of QRD microwave, the highest efficiency was obtained at 35 cm height and in the center of the chamber. When irradiating 5 kW of QRD microwave, high efficiency was obtained on the sides of the chamber. When irradiating 3 kW of QRD microwave to Magnetrons 1, 2 and 3, the temperature uniformity according to the position of the bars was similar in the position of Bar 1 and 2. When irradiating 3 kW of QRD microwave to Magnetrons 3, 4 and 5, the temperature increased by approximately 10 to 20% in Bar 3. When irradiating 5, 7 and 9 kW of magnetron, the average temperature during the irradiation time increased in a similar form independently of the position of the bars. On the other hand, the efficiency of the chamber's proper internal volume was not necessarily proportional to the irradiation dose. When irradiating 3 kW of magnetron for 60 120 and 180 seconds, the temperature increased by approximately 5 to 10 at the edge of the chamber according to the irradiation position of magnetron. The temperature distribution for each position in the horizontal plane was relatively uniform, and the temperature had a tendency to slightly increase at the edge. When irradiating 5, 7 and 9 kW of magnetron, the temperature relatively evenly increased independently of the position of the bars. It was thought necessary to increase the irradiation dose by approximately 10 to 20% by considering the difference in temperature rise according to the position of magnetron.