Development of Classification Model on SAC Refrigerant Charge Level Using Clustering-based Steady-state Identification (군집화 기반 정상상태 식별을 활용한 시스템 에어컨의 냉매 충전량 분류 모델 개발)

  • Jae-Hee, Kim;Yoojeong, Noh;Jong-Hwan, Jeung;Bong-Soo, Choi;Seok-Hoon, Jang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.6
    • /
    • pp.357-365
    • /
    • 2022
  • Refrigerant mischarging is one of the most frequently occurring failure modes in air conditioners, and both undercharging and overcharging degrade cooling performance. Therefore, it is important to accurately determine the amount of charged refrigerant. In this study, a support vector machine (SVM) model was developed to multi-classify the refrigerant mischarge through steady-state identification via fuzzy clustering techniques. For steady-state identification, a fuzzy clustering algorithm was applied to the air conditioner operation data using the difference between moving averages. The identification results using the proposed method were compared with those using existing steady-state determination techniques studied through the inversed Fisher's discriminant ratio (IFDR). Subsequently, the main features were selected using minimum redundancy maximum relevance (mRMR) considering the correlation among candidate features, and an SVM multi-classification model was devised using the derived features. The proposed method achieves satisfactory accuracy and robustness from test data collected in the new domain.

A Study on the Operation Improvement of Door Fan Test (Door Fan Test 운영개선에 관한 연구)

  • Kong, Il-Chean;Kim, Hak-Kyung;Choi, Du-Chan;Kim, In-Tae
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.275-277
    • /
    • 2016
  • 본 논문에서는 Door Fan Test 수행 사례를 중심으로 사전 준비에 필요한 사항에 대해 분석하였다. 분석 결과 관통부 주위 개구부, 벽체 틈새 개구부 등 방화구역의 누설부위를 통해 약제가 누출되는 문제가 있었다. 원인으로는 전기배선 공사로 인해 내화충전된 부분을 제거하고 공사 후 다시 충전하지 않는 경우, 벽과 천장사이의 틈을 내화 실란트 등으로 마감을 하지 않은 경우가 대부분이었다. 이와 같이 누설부위가 많은 경우 테스트의 결과 불합격이 나오게 되며, 이러한 문제점을 개선하기 위해 사전현장조사를 통해 방호구역의 누설부위를 조사하고 보완조치를 진행한 후 테스트를 수행하는 절차가 필요하였다. 한편, 테스트 운영에 관한 사항으로는 해당 실(room)을 위한 충분한 유량 미확보, 장애물로 인한 와류형성, 차압측정구의 설치문제 등이 있었다. 이를 개선하기 위해서 공기를 유입하는 실은 외부로부터 충분한 공기유입이 있어야하며, 팬 앞의 장애물을 제거하거나 팬의 설치 위치를 조정하는 것이 필요하며, 공기의 유동이 가장 적은 곳에 측정구를 설치하는 등의 조치가 필요하다.

  • PDF

Step-wise Growth of Dendrimer over Mesoporous SBA-15 Synthesized Using Ricehusk Ash as Silica Source (쌀겨회재에서 추출된 실리카를 이용한 메조포러스실리카 SBA-15의 계단식 Dendrimer의 합성)

  • Lee, Ji-Yun;Lee, Hwa-Yung;Bhagiyalakshmi, Margandan;Jang, Hyun-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.91-94
    • /
    • 2009
  • 쌀겨회재에서 추출한 실리카원을 이용하여 메조포러스실리카 SBA-15를 합성하였으며, 이산화탄소에 대한 높은 선택성을 나타내는 아민기를 우수한 구조성을 지닌 메조포러스실리카에 그라프팅하였다. 아민기가 그라프팅된 메조포러스실리카에 높은 흡착능을 도출하기 위해서 dendrimer/SBA-15를 반응조건에 따라 합성하였다. 이와 같이 합성된 고체흡수제는 X-선 회절분석, 질소 흡,탈착 곡선, 분광분석 (FT-IR)등의 특성 분석을 수행하였고, 열중량반응기 및 충전층 반응기에서 이산화탄소 흡수실험을 수행하였다.

  • PDF

Applicability of Solidified Soil as a Filling Materials of Bored Pile (매입말뚝 충전재로서 고화토의 적용성)

  • Kim, Khi-Woong;Chai, Jong-Gil;Han, Byung-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.3
    • /
    • pp.37-42
    • /
    • 2012
  • The cement paste is mostly used as the filling materials of bored pile in Korea. The use of filling material based on cement paste is inefficient at field construction because it needs a lot of the charging mass. In addition, it has environmental problem according to the large amount of cement use because its strength is also larger than criterion. The excavated soil with stabilizer can be used as the filling materials when the bored pile is constructed. Therefore, this paper describes field application of solidified soil for economical efficiency and environment-friendly. The injection capacity of solidified soil is compared with cement paste's based on unconfined compressive strength test and field load test, and the appropriate of test results is evaluated by design criterion. The evaluation result shows that the capacity of excavated soil with stabilizer is similar to cement paste and the solidified soil is able to apply as filling materials of bored pile because it is satisfied with design criterion.

Non-linear Analysis of Full Scaled CFT Column to H-Beam Connections with T-Stiffeners (T 스티프너를 이용한 CFT기둥-H 형강보 실대형 접합부의 비선형 해석)

  • Lee, Seung Woo;Kim, Young Joo;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.835-843
    • /
    • 2002
  • The goal of this paper is to understand the stress-transfer mechanism of concrete-filled tubular column to H-beam connection with external T stiffener through the elasto-plastic finite element method and to offer basic data for the design of T stiffener. For the accuracy, analysis results are compared with experimental results. It makes use of several stress and strain indices to understand the stress-transfer mechanism of connection. An alternative plan that decreases the stress concentration of beam flange to horizontal stiffener connection is proposed through the elasto-plastic finite element method.

A study on the new high efficiency rectifier system (고효율 신형 정류시스템에 대한 고찰)

  • Kim, Gue-Hong;Jeong, Jae-Hoon;Cho, Man-Hyun;Ahn, Che-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3172-3174
    • /
    • 1999
  • 교환기나 전송장치 등 각종 통신설비에 전원을 공급하기 위해서 정류기, 축전지 및 발전기 등의 전원설비가 사용되고 있다. 이들 중에서도 정류기는 통신설비에 직류전원을 공급하기 때문에 다른 전원설비 보 다도 신뢰성 및 안정성이 확보된 장치로 인식되어 왔다. 그러나 현재 사내전화국에 설치 운용중인 정류기는 교환 기별로 종류가 다양하여 유지보수에 어려움이 내재하고 있을 뿐만 아니라 통신망의 광대역화, 대용량화에 대처가 곤란하며 정류기를 전력실 또는 통신실에 집중해서 설치 운용하는 집중공급방식으로는 축전지의 만충전이 곤란하다. 또한 현재의 이러한 급전방식은 통신장치의 광대역화, 고도화 등 통신망의 급격한 발전과 함께 다음과 같은 문제점이 대두되고 있다. 첫째, 전력실에서 총괄하여 교류전력을 직류48V로 변환해서 급전하기 때문에 급전전류가 크게되고, 또한 전력실에서 통신실까지의 급전손실이 크다 둘째, 통신설비의 증감에 따른 전원설비의 증감이 어렵기 때문에 설비 가동율이 나쁘다 셋째, 전원설비의 고장에 의한 전화국 전체설비에 심각한 영향을 미칠수 있다 이러한 문제점을 해소하기 위하여 집중 및 분산급전방식으로 운용이 가능하며, 또한 모든 전원설비를 감시/제어하는 전원 집중관리 시스템과의 인터페이스 등이 가능한 정류시스템을 1997년부터 개발하였다. 본고에서는 신형 정류기와 기존의 정류기와의 성능 및 특성에 대해 비교하였고, 특히 경제성측면과 설치상련에 대해 비교분석 하였다. 또한 집중급전방식과 분산급전방식의 특성에 대해서도 서술하였다.

  • PDF

Development of an Igniter for Pyrostarters (파이로스타터용 점화기 개발)

  • Park, Ho-Jun;Hong, Moon-Geun;Kwon, Mi-Ra;Lee, Soo-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.149-152
    • /
    • 2009
  • A pyrostarter is a sort of gas generator, which supplies the energy to drive turbines by the combustion gas of a solid propellant charged internally. The igniter of the pyrostarter should guarantee the ignition reliability expecially for the solid propellant with a low fame temperature. For the development of the igniter, several closed bomb testes have been performed to decide several design parameters to get a sufficient chamber pressure build-up for the ignition. Moreover, as a result of the firing testes with pyrostarters, the ignition reliability have been verified and the amount of igniter propellants has been reviewed.

  • PDF

Analysis of Harmonic Effects due to Charging of Electric vehicles (전기자동차 충전에 의한 고조파 영향 분석)

  • Kim, Ji-Hun;Sim, Hyeong-Wook;Ju, Seong-Chul;Lee, Jae-Won;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.79-80
    • /
    • 2011
  • 전기자동차 급속 충전기는 AC/DC 컨버터와 DC/DC 컨버터와 같은 전력변환장치, 차량과 충전기를 연결하는 충전인터페이스, 전력 공급설비, 차량과 충전기 상호 커뮤니케이션을 위한 통신망 등으로 구성된다. 따라서 전기자동차 급속 충전기의 전력변환장치로부터 전력계통으로 역류, 전력품질 및 전력기기 등에 악영향을 미치는 고조파가 발생되기 때문에 이에 대한 적절한 대책이 필요하다. 본 논문에서는 전기자동차 연계에 따른 전력 계통에서의 고조파 영향을 분석하기 위해 ATPDraw/MODESLS를 이용하여 급속 충전기의 전력변환장치인 AC/DC 컨버터와 DC/DC 컨버터를 모델링 하였고, 이를 한전 실 배전계통에 연계하여 차수별 고조파 및 THD(Total Harmonic Distortion)를 분석하였다.

  • PDF

Development of On Board Charger for NEV's Integrated Power Converter (NEV용 통합형 전력변환장치의 탑재형 충전기 개발)

  • Kim, G.M.;Kim, T.K.;Kang, C.H.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.1-2
    • /
    • 2012
  • 도심형 전기자동차의 주요 전력변환장치인 모터구동제어기와 전장전력공급용 DC/DC 컨버터, 고전압배터리 충전기 등을 일체형으로 개발함으로써 하우징의 간소화, 방열부 및 커넥터의 불필요한 요소를 저감할 수 있어 원가절감과 연비개선 등의 효과를 얻을 수 있다. 본 논문에서는 통합형 전력변환장치 중에서 고전압배터리의 충전시간을 단축시키도록 고성능, 고효율 탑재형 충전기를 설계하고 이를 제작하여 실 충전시험으로 성능을 확인하고자 한다.