Characteristics of Heat Flux in a Compartment Fire - Reduced Scale Test (구획공간 화재의 열유속 특성 - 축소 실험)

  • Kim, Sung-Chan;Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.128-133
    • /
    • 2011
  • The present study performs a series of 40 % reduced scale of ISO-9705 fire test to investigate the characteristics of heat flux on the floor level in terms of fire characteristics and location in the compartment. The heat flux was measured with Schmidt-Boelter type heat flux gauge at two locations on the floor level of inside and doorway side of the compartment. Different types of fuel - methane, heptane, toluene, ethanol, polystyrene - were burned in this test series. The measured heat flux inside of the compartment was relatively higher than that of front side as the heat release rate of fire and upper layer temperature increased. The difference of measured heat flux at inside and doorway side increased for high sooty fire. The present study shows that the heat flux distribution at lower layer greatly depend on the thermal radiation from fire and upper layer, not only the upper layer temperature but also various fire characteristics such as composition of combustion gases, soot concentration, ventilation condition and so on.

Investigation for Fire Flow of the Deeply Underground Shin-Gum-Ho Subway Station (대심도 신금호역사의 화재 유동에 대한 고찰)

  • Jang, Yong-Jun;Park, Il-Soon;Kim, Jin-Ho;Jung, Woo-Sung;Kim, Hag-Beom;Lee, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.110-115
    • /
    • 2010
  • Recently the deeply underground tunnels have been increased along the subway railroads of urban area compared to the past subway railroads. The Shin-Gum-Ho subway station (the Fifth lines, the depth : 46m) which is the third among the deep subway stations in the Korea was chosen as the model of deeply underground stations, and attempted to do simulation of fire. This station consists of three entrance, the basement first floor (B1), the basement second floor (B2), the basement eighth floor or platform (B8) and escalators and stairs from B2 to B8. The total number of grid was about 9,000,000 to make simulation of fire and smoke from the platform to entrance in this research, and the grid system was divided into 19 blocks to increase the efficiency of this simulation. The FDS (Fire Dynamics Simulation) was chosen to make the simulation of fire, and the model of turbulent flow was LES (Large Eddy Simulation). Each block is processed in a CPU using parallel processing of MPI (Message Passing Interface). The resource of CPU for this simulation is a ten of Intel 3.0 GHz Dual CPU (20 CPU).

  • PDF

Experimental Study on the Slanted Portals for Reducing the Micro-pressure Waves in High-speed Train-tunnel System(I) (고속철도 터널에서 경사갱구 입구의 미기압파 저감성능에 관한 연구(I))

  • Kim, Dong-Hyeon;Shin, Min-Ho;Han, Myeong Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.2
    • /
    • pp.3-10
    • /
    • 2000
  • The compression wave produced when a high-speed train enters a tunnel propagates along the tunnel ahead of the train. The micro pressure wave related to the compression wave is a special physics phenomena created by high-speed train-tunnel interfaces. A among methods for the purpose of reducing the micro pressure wave is to delay the gradient of the compression wave by using aerodynamic structures. The objective of this paper is to determine the optimum slanted portal using the moving model rig. According to the results, the maximum value of micro pressure wave is reduced by 19.2% for the $45^{\circ}$ slanted portal installed at the entrance of the tunnel and reduced by 41.9% for the $45^{\circ}$ slanted portals at the entrance and exit of the tunnel. Also it is reduced by 34.6% for the $30^{\circ}$ slanted portals installed at the entrance and exit of the tunnel.

  • PDF

Methods of Ensuring Safety for Integrated Fire Protection Shutters at Elementary and Middle Schools (초등학교 및 중학교의 일체형 셔터 안전성 확보 방안)

  • Youn, Hae-Kwon
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.36-45
    • /
    • 2016
  • Integral fire shutters are installed indiscriminately, regardless of evacuation. There is always the risk of an accident because integral shutters are applied mainly to corridors, passages, and stairs of schools This study evaluated the problem of integral shutter's entrance, evacuation, construction management, and maintenance control through a fire shutter accident case, including present condition of fire shutter installed at school of Okgil, Bucheon and Dongtan, Hwaseong. The results suggest that emergency lighting or signs for passage be set up to check location of entrance easily and install obstruction sensors at fire shutter to reduce life damage. In addition, the number of efficiency tests of fire shutters should be increased by running a trial test monthly or weekly to maintain the performance of fire shutter. Schools need to install a fire shutter- applied sprinkler at the entire floor.

Evaluation of structural integrity of the HP vaporizer and pipes of LNG fuel gas supply system (LNG 연료 선박용 FGSS의 고압 기화기와 출입구 배관에 대한 구조 건전성 평가)

  • Kim, Chang-Soo;Yoon, Joo-Hwan;Lee, Chang-Joon;Ha, Man-Young;Cho, Jong-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.780-785
    • /
    • 2016
  • Heavy oil used as ship propulsion has a serious issue regarding exhaust emission of global warming. Recently, among large-scale merchant ships are using LNG as green ships so called ech-ships. In this study, an vaporizer and pipes under cryogenic and high pressure load were considered to evaluate structural integrity according to codes. Structural analysis of the vaporizer and pipes was performed using the commercial code, ANSYS. Integrity evaluation of the vaporizer based on von Mises stress was performed in accordance with allowable stress specified in ASME Boiler & Pressure Vesssel Section VIII Division 2. To assess structural integrity of the pipes, stress components were combined and compared with ASME B31.3. The calculated stresses for all load cases are lower than allowable stresses, therefore the structural integrity of equipments are verified.

Research on Safety Design of Residence Based on CPTED Strategy -focused on Gamcheon cultural village in Busan, Korea as an example- (CPTED 전략에 근거한 주거지역의 안전디자인에 관한 연구 -한국 부산 감천문화마을 사례를 중심으로-)

  • Zhang, Ning;Cho, Joung-Hyung
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.93-104
    • /
    • 2021
  • In the process of the sustainable development of the world economy, the change and construction of urban living environment has always been the focus of people's attention. Therefore, the purpose of this study is to find out the potential safety hazards in residential areas, and put forward feasible improvement plans under the framework of CPTED theory.One is to collect the necessary literature. Secondly, according to the field investigation and questionnaire survey, sorting out the existing security risks. Finally, this paper puts forward the corresponding improvement and suggestion to this research. The conclusion is as follows: First, based on the six principles of CPTED theory, problems existing in Gamcheon Cultural Village, which is subject to research, were investigated. Second, six of the most serious safety issues (safety handle, landscaping, entrance control, signs, empty space, monitoring) were objectively analyzed, and designs were presented in terms of increasing safety stairs, installing automatic entrances, open access view, unifying signs, and building leisure areas.

Study on the Real-time COVID-19 Confirmed Case Web Monitoring System (실시간 코로나19 확진자 웹 모니터링 시스템에 대한 연구)

  • You, Youngkyon;Jo, Seonguk;Ko, Dongbeom;Park, Jeongmin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.171-179
    • /
    • 2022
  • This paper introduces a monitoring and tracking system for corona19 confirmed patients based on the collected data by installing a device that can manage the access list at the entrance to each building on the campus. The existing QR-based electronic access list can't measure the temperature of the person entering the building and it is inconvenient that members have to scan their QR codes with a smartphone. In addition, when the state manages information about confirmed patients and contacts on campus, it is not easy for members to quickly share and track information. These could lead to cases where a person is in close contact with an infected person developing another patient. Therefore, this paper introduces a device using face recognition library and a temperature sensor installed at the entrance of each building on the campus, enabling the administrator to monitor the access status and quickly track members of each building in real-time.

A Study on the Spatial Composition of the emergency medical center (응급의료센터의 공간구성에 관한 건축계획적 연구)

  • Choi, Sung-Bong;Kim, Kwang-Moon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.5 no.8
    • /
    • pp.63-70
    • /
    • 1999
  • The patient characters in medical emergency facilities is in emergent situation and very wide medical area. So, the spatial composition of this facilities should be more efficient than general medical ones. For this reason, patient who visit medical emergency center should be triaged by each property of patient. And then the clinical space is to be composed in response to flow of each patient group that triaged. Therefore this study aims to find method of the spatial composition and architectural details of medical emergency center.

  • PDF

A Study on the Development of New Address Management System for Jecheon-si area (제천시 새주소 관리시스템 개발에 관한 연구)

  • Yeon, Sang-Ho;Kim, Jang-Su
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.227-236
    • /
    • 2001
  • 본 연구는 제천시 새주소 부여사업에서 추진된 새주소 부여를 위한 수치지도상의 건물 및 도로의 데이터베이스와 주 출입구 조사 및 입력, 도로구간 설정, 도로명 제정 및 입력, 건물번호부여 등의 작업과정을 통하여 도시공간정보의 체계적인 관리와 활용을 위한 새주소 관리 시스템 개발에 대한 것이다. 본 연구를 통하여 지방 중소도시의 새주소 관리시스템 개발과 구축은 클라이언트 서버 기반의 GIS 기능을 충분히 활용하여 관리시스템을 설계하고, 관리시스템의 데이터베이스를 객체지향 형으로 구축에 의한 WEB-GIS로 구현하여 새 주소의 안내 및 생활지리정보서비스의 다양할 기능을 추가할 수 있도록 개발하였다. 그 결과로 제천시의 새주소 관리시스템은 기존의 GIS DBMS의 접근방식을 개선하여 다양한 새 주소의 도로와 연계된 건물의 위치정보를 신속하게 이용할 수 있는 그 효용가치를 크게 높일 수 있었다.

  • PDF

Embedded System Internet Remote Controller (임베디드 시스템 인터넷 원격제어 장치)

  • Park, Jae-Sam
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.9
    • /
    • pp.883-890
    • /
    • 2004
  • In this paper, new structures of embedded internet remote control systems, which can control electo-mechanical systems, are developed. For this, remote interface system structure using embedded system are developed first, then the way of internet remote control and the PC program for the control are discussed. The developed syste in this paper can be applied to home automations such as to control entrance doors, lights, consumer electronics and other industrial applications. To show the example illustrations, in this paper, the deyeloped system has been applied to multiple motor control systems. The results show that the developed system can directly be applicable into the real industrial field.

  • PDF