• Title/Summary/Keyword: 출력인수

Search Result 53, Processing Time 0.02 seconds

A Study on the system composition for output elevation of Photovoltaic system (태양광발전 시스템의 출력 향상을 위한 시스템 구성에 관한 연구)

  • Yoon, Jeong-Phil;Park, Se-Joon;Gang, Byong-Bok;Jo, Keong-Jae;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.231-234
    • /
    • 2002
  • This treatise composes 450 [W] small size PV systems as thing for output elevation of PV system, investigated kind of output loss parameter. And, referred clear day and cloudy day about loss among the much parameters. Also, examined about loss between storage battery from system output part. Experiment result, could know that loss between storage battery is big from output part, and could know that output by that get dirty of module surface is decreased.

  • PDF

A Study on Performance Characteristics of PEMFC with Thermal Variation (온도에 따른 고분자 전해질형 연료전지시스템의 출력 특성 연구)

  • Park, Se-Joon;Shin, Young-Sik;Jeong, Seong-Chan;Choi, Jeong-Sik;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.212-214
    • /
    • 2009
  • The polymer electrolyte membrane fuel cell(PEMFC) with the advantages of low-operating temperature, high current density, low cost and volume, fast start-up ability, and suitability for discontinuous operation becomes the most reasonable and attractive power system for transportation vehicle and micro-grid power plant in a household. 200W PEMFC(Polymer electrolyte membrane fuel cell) system applied to middle and small-scaled micro-grid power system was constructed by this study, then the electrical characteristics and diagnosis of the fuel cell were analyzed with thermal variation.

  • PDF

A study on the network monitoring system of a guard lamp apply photovoltaic system (태양광 보안등의 네트워크 모니터링 시스템에 관한 연구)

  • Jeong, Ju-Seob;Yoon, Jeong-Phil;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.340-342
    • /
    • 2005
  • 태양광 발전 시스템은 신재생에너지의 한 분야로서 이동형 전원부터 대용량 발전 시스템까지 다양한 분야에 적용되고 있다. 본 논문에서는 응용분야의 하나인 정원 보안등에 관한 것이다. 기존 정원 보안등은 전원으로 소형 전지를 내장하여 구동하는 방식과 일반 상용전원을 연결하여 구동하는 방식이 대표적이었다. 본 논문에서는 태양전지를 정원 보안등에 적용하여 내부 충전지를 충전 구동하는 방식을 택하였다. 반사갓의 구형과 신형, 외부요건 변화에 따른 출력의 특성을 비친 분석 모니터링 하였다.

  • PDF

A study on the characteristics driving of 10kW photovoltaic system (10kW 태양광 발전 시스템의 운전특성에 관한 연구)

  • Ha, Min-Ho;Yoon, Jeong-Phil;Jeong, Ju-Seob;Cha, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.314-316
    • /
    • 2005
  • 태양광 발전은 화석에너지의 대안으로서 청정에너지로서의 상징성을 발휘하며 시범사업 및 일반보급사업을 통하여 국내에 확대 보급되고 있다. 본 논문에서는 에너지관리공단의 지원을 받아 동신대학교 생물자원산업화지원센터에 설치된 10kW 태양광 발전시스템의 운전특성 연구에 관한 것으로서, RS-232 통신을 이용 설치된 센서의 출력 값을 PC로 모니터링하여 결과값을 분석하였다.

  • PDF

Development of Medical System using Time-varying Magnetic field (시변 펄스형 자기장 의료기기 시스템)

  • Kim, In-Soo S.;Hong, Jung-Hwang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.12
    • /
    • pp.2343-2351
    • /
    • 2007
  • In this paper, we describe the design and implementation of time-varying magnetic field stimulator. Novel design for power supply part to generate high repetitive magnetic field for very short time(less than $300{\mu}s$) was achieved. Using the novel designed power supply part and the circular type coil probe, we've achieved high magnetic field up to 1.2 Tesla in 20Hz repetition rate.

Natural question generation based on consistency between generated questions and answers (생성된 질의응답 간 일관성을 이용한 자연어 질의 생성)

  • Jaehong Lee;Hwiyeol Jo;Sookyo In;Sungju Kim;Kiyoon Moon;Taehong Min;Kyungduk Kim
    • Annual Conference on Human and Language Technology
    • /
    • 2022.10a
    • /
    • pp.109-114
    • /
    • 2022
  • 질의 생성 모델은 스마트 스피커, 챗봇, QA 시스템, 기계 독해 등 다양한 서비스에 사용되고 있다. 모델을 다양한 서비스에 잘 적용하기 위해서는 사용자들의 실제 질의 특성을 반영한 자연스러운 질의를 만드는 것이 중요하다. 본 논문에서는 사용자 질의 특성을 반영한 간결하고 자연스러운 질의 자동 생성 모델을 소개한다. 제안 모델은 topic 키워드를 통해 모델에게 생성 자유도를 주었으며, 키워드형 질의→자연어 질의→응답으로 연결되는 chain-of-thought 형태의 다중 출력 구조를 통해 인과관계를 고려한 결과를 만들도록 했다. 최종적으로 MRC 필터링과 일관성 필터링을 통해 고품질 질의를 선별했다. 베이스라인 모델과 비교해 제안 모델은 질의의 유효성을 크게 높일 수 있었다.

  • PDF

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.

Development of Total Body Irradiation Program (전신방사선조사 프로그램 개발)

  • Choi Byung Ock;Jang Ji Sun;Kang Young Nam;Choi Ihl Bohng;Shin Sung Kyun
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.130-137
    • /
    • 2005
  • In total body irradiation (T81) for leukemia, we have a two methode. One is a AP (anterior-posterior) method and the other is a Lateral methode. Our hospital used lateral methode. T81 must consider about body contour, because of homogeneous dose distribution. For compensation about irregular body contour, we use compensator. For T81 treatment, we must be considered, accurate manufacture of compensator and accurate calculation of dose. We developed the automatic program for T81. This program accomplished for compensator design and dose calculation for irregular body. This program was developed for uses to use in a windows environment using the IDL language. In this program, it use energy data for each energy: TMR, output factor, inverse square law, spoiler, field size factor. This program reduces the error to happen due to the manual. As a development of program, we could decrease the time of treatment plan and care the patient accurately.

  • PDF

웹에 기반한 선량교정 프로그램 개발

  • 신동오;서원섭;박성용;김성훈;지영훈;김근배;이창건;강진오;홍성언
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.66-66
    • /
    • 2003
  • 목적 : 선량측정의 정확성을 향상시키기 위하여 물 흡수선량 표준에 토대를 두고 있는 표준측정법, AAPM TG-51과 IAEA TRS-398, 이 발표되어 선량측정의 파라다임이 변화하고 있다. 본 연구에서는 이들 대표적인 표준측정법에 대하여 사용자 편의성을 고려하여 웹에 기반한 선량교정 프로그램을 개발하고자 한다. 대상 및 방법 : 미국의학물리학회 AAPM TG-51과 국제원자력기구 IAEA TRS-398 표준측정법에 선량교정 프로그램은 Microsoft IIS 6.0 웹서버와 .NET 플렛폼상에서 Visual Studio. NET 도구를 사용하여 개발하였다. 개발언어로는 C# 언어를 사용하였고 각 표준측정법에 대한 선량교정 작업서는 ASP. NET 페이지로 작성하였다. 웹페이지와 산량 교정 모듈을 분리하여서 개발 후 유지보수가 쉽게 설계하였다. 또한 기준점에서의 선량 계상에 사용하는 모든 물리적인 파라미터와 데이터는 데이터베이스에 저장하였다. 이로써 향후 수식체계의 변화 또는 물리적인 데이터의 변화로 인한 프로그램 수정이 최소화하도록 하였다. 결과 : 이들 표준측정법은 모두 물 흡수선량 교정인수에 토대를 두고 있으나 측정 조건 및 물리적인 자료 에 있어 약간의 차이를 보이고 있다. 그러므로 각 표준측정법간의 유사점 및 차이점을 비교 분석하기가 용이하였다. 그리고 개발된 프로그램을 이용하여 표준측정법에서 제시된 선량교정 작업서에 따라 선량 교정을 수행한 교정 결과 데이터를 XML 파일 형식으로 저장하여 이전의 측정 자료를 관리할 수 있게 하였다. 이 과거 측정 자료를 사용하여 출력 선량 교정의 변화 및 기타 중요한 물리적인 데이터 값의 변화를 분석할 수 있다. 결론 : 두 표준측정법에 대한 선량교정 프로그램은 사용자가 선호하는 표준측정법을 선택할 수 있고, 웹에 토대를 두고 있어 프로그램으로 전국 방사선종양학과의 방사선치료기기의 출력 및 물리적인 변화에 대한 자료를 비교 분석하기 용이하고 수작업으로 인해 발생할 수 있는 실수 및 오차를 줄일 수 있다. 또한 개발된 프로그램의 활용을 통하여 국내 실정에 적합한 물 흡수선량 표준에 기반한 표준측정법 개발에 토대를 마련하는데 있어 기여할 것으로 사료된다.

  • PDF

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF