• Title/Summary/Keyword: 출력변동률

Search Result 26, Processing Time 0.031 seconds

A Study on Instantaneous Voltage Compensation of UPS using on Ultracapacitor (울트라커패시터를 이용한 UPS의 순시전압보상에 관한 연구)

  • Kim, Choon-Sam;Kim, Ji-Heon;Kim, Soo-Hong;Sung, Won-Ki
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.18-24
    • /
    • 2006
  • This paper proposed UPS system parallel connected in battery and ultracapacitor to compensate instantaneous voltage drop. Ultracapacitor parallel connected with battery compensate instantaneous voltage drop at failure and it's reduced the voltage regulation of output voltage. We are produced for fast instantaneous voltage drop compensation of ultracapacitor at UPS system and experiments are achieved. Experimental result was verified that the ultracapacitor indicated the fast compensation characteristics and regulation of the output voltage satisfied within 5[%] by using ultracapacitor.

A Temperature- and Supply-Insensitive 1Gb/s CMOS Open-Drain Output Driver for High-Bandwidth DRAMs (High-Bandwidth DRAM용 온도 및 전원 전압에 둔감한 1Gb/s CMOS Open-Drain 출력 구동 회로)

  • Kim, Young-Hee;Sohn, Young-Soo;Park, Hong-Jung;Wee, Jae-Kyung;Choi, Jin-Hyeok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.54-61
    • /
    • 2001
  • A fully on-chip open-drain CMOS output driver was designed for high bandwidth DRAMs, such that its output voltage swing was insensitive to the variations of temperature and supply voltage. An auto refresh signal was used to update the contents of the current control register, which determined the transistors to be turned-on among the six binary-weighted transistors of an output driver. Because the auto refresh signal is available in DRAM chips, the output driver of this work does not require any external signals to update the current control register. During the time interval while the update is in progress, a negative feedback loop is formed to maintain the low level output voltage ($V_OL$) to be equal to the reference voltage ($V_{OL.ref}$) which is generated by a low-voltage bandgap reference circuit. Test results showed the successful operation at the data rate up to 1Gb/s. The worst-case variations of $V_{OL.ref}$ and $V_OL$ of the proposed output driver were measured to be 2.5% and 7.5% respectively within a temperature range of $20^{\circ}C$ to $90^{\circ}C$ and a supply voltage range of 2.25V to 2.75V, while the worst-case variation of $V_OL$ of the conventional output driver was measured to be 24% at the same temperature and supply voltage ranges.

  • PDF

Development of High Voltage Power Supply for A-BNCT (A-BNCT(Boron Neutron Capture Therapy) 시스템 구동을 위한 고전압 전원장치개발)

  • Lee, kyunkyu;Park, S.S.;Choi, B.H.;Kim, D.S.;Kim, Y.W.;Kim, H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.638-641
    • /
    • 2018
  • 현재 선진국에서는 고출력 양성자 선형 가속기를 기반으로 한 의료용 암치료기인 BNCT(Boron Neutron Capture Therapy)에 대해 활발히 연구 중이며 다원시스도 2016년부터 A-BNCT 사업을 진행 중이다. A-BNCT에 적용된 양성자 선형 가속기의 RF(Radio Frequency)전원을 공급하기 위해 352 MHz, 1.5 MW의 고출력을 가지는 클라이스트론을 사용하였다. 클라이스트론의 출력인 RF의 크기와 위상을 안정적으로 제어하기 위해 90 kV, 30 A, 120 Hz, 1.7 ms의 구형파 출력을 가지는 고전압 전원장치를 적용하였다. 또한 고전압 전원장치의 출력전압 변동률을 0.5% 이내로 유지시키기 위해 전압보상회로를 적용하여 회로 시뮬레이션과 실부하 실험을 통해 펄스전원장치의 성능을 검증하였다.

  • PDF

Variable and Controllable Digital Power-supply Design (원격조종이 가능한 디지털 가변전원 구현)

  • Choi Sung-Yug;Hur Hwa-Ra
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.1
    • /
    • pp.21-26
    • /
    • 2006
  • In this paper, to improve the variable and remote controllable digital power-supply design. It is able to RS-232 communication for remote control. And it can also observe the correct power. Finally, it intend to high ratio design that compare input power with output power. There are especially useful solution in korea to be under the unstable voltage environment.

  • PDF

Development of Hybrid AVR for Alternator (교류 발전기용 하이브리드 자동 전압 조정기 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.182-188
    • /
    • 2015
  • An analog AVR has an advantage of short time constant, time to revert again from the abnormal state to a stable one depending on the voltage fluctuations of the load. But the Analog AVR has a disadvantage of large voltage variation according to the load fluctuation. Voltage regulation for digital AVR is very stable, but the time constant is very long compared to that of an analog AVR. Therefore, it indicates that the digital AVR shows unstable output performance in a very large load variations. In this paper, a mixed form of an analog AVR and a digital AVR is proposed. An implemented hybrid AVR has fast time constant and stable voltage regulation capability. Hybrid AVR voltage variations in the load is stable within 1[%] and the voltage stability is also improved. It also showed fast time constant to the level of the analog AVR. Thus hybrid AVR developed in this paper can be used as a power supply for a variety of uses in industry.

Predicting The Direction of The Daily KOSPI Movement Using Neural Networks For ETF Trades (신경회로망을 이용한 일별 KOSPI 이동 방향 예측에 의한 ETF 매매)

  • Hwang, Heesoo
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.1-6
    • /
    • 2019
  • Neural networks have been used to predict the direction of stock index movement from past data. The conventional research that predicts the upward or downward movement of the stock index predicts a rise or fall even with small changes in the index. It is highly likely that losses will occur when trading ETFs by use of the prediction. In this paper, a neural network model that predicts the movement direction of the daily KOrea composite Stock Price Index (KOSPI) to reduce ETF trading losses and earn more than a certain amount per trading is presented. The proposed model has outputs that represent rising (change rate in index ${\geq}{\alpha}$), falling (change rate ${\leq}-{\alpha}$) and neutral ($-{\alpha}$ change rate < ${\alpha}$). If the forecast is rising, buy the Leveraged Exchange Traded Fund (ETF); if it is falling, buy the inverse ETF. The hit ratio (HR) of PNN1 implemented in this paper is 0.720 and 0.616 in the learning and the evaluation respectively. ETF trading yields a yield of 8.386 to 16.324 %. The proposed models show the better ETF trading success rate and yield than the neural network models predicting KOSPI.

Power stabilization of a slab CO2 laser by using the Opto-Hertzian effect (Opto-Hertzian 효과를 이용한 고주파 여기식 슬랩 CO2 레이저의 출력 안정화)

  • 최종운;우삼용;김규식;이영우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.337-342
    • /
    • 2004
  • Laser optical power stabilization of a radio frequency excited $CO_2$ slab laser using the opto-Hertzian effect generated from the laser itself is achieved on the peak of the Doppler broadened gain curve. The opto-Hertzian signal was generated by a modulation of the optical flux circulating inside the laser cavity from a variation in the cavity length caused by the vibrations of the PZT. The opto-Hertzian signal is directly coupled from a RE discharge chamber via a loop antenna into a detector and applied to a lock-in stabilizer as an reference signal. The power stability of an RF excited slab laser is estimated to be better then 0.2%.

A Study on the Determining ESS Capacity for Stabilizing Power Output of Haeng-won Wind Farm in Jeju (제주 행원 풍력발전단지의 출력 안정화를 위한 에너지저장시스템 용량산정에 관한 연구)

  • Kang, Myeong-Seok;Jin, Kyung-Min;Kim, Eel-Hwan;Oh, Sung-Bo;Lee, Jeong-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • This paper presents the characteristics of power generation output at Haeng-won wind farm and how to determine the optimized ESS capacity for power stabilizing. Depend on the fluctuation rate of wind power output variation, wind farm capacity and site, power stabilization will be impacted. Therefore, we need to determine proper ESS capacity. Using the actual data of Haeng-won wind farm from 2009. 3 to 2010.2., capacity of ESS was determined by moving average value. To verify the proposed algorithm, simulations are carried out with PSCAD/EMTDC program. As a result, optimal ESS capacity of Haeng-won wind farm in Jeju is estimated about 1.63 MWh.

High Power Density Bidirectional DC-DC Converter for LDC of Fuel Cell Vehicles (연료전지 자동차용 LDC를 위한 고전력 밑도 양방향 DC-DC 컨버터)

  • Kim, Hyung-Joon;Choi, Se-Wan;Kang, Ho-Sung;Choi, Seo-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.548-552
    • /
    • 2007
  • 본 논문에서는 연료전지자동차의 저전압 배터리 충${\cdot}$방전을 위한 3상 양방향 DC-DC 컨버터를 제안한다. 제안한 3상 컨버터는 기존의 단상 컨버터에 비해 인터리빙 효과의 증대로 인한 입${\cdot}$출력 필터 사이즈 감소와 변압기의 이용률 증가로 인한 VA정격의 감소가 가능하며, 기존의 위상제어 방식의 3상 컨버터와 달리 입${\cdot}$출력전압이나 부하변동에 따른 무효 전류의 중가 문제가 없다. 또한 MOSFET 스위치를 사용하여 고전압 측에서는 비대칭 소프트 스위칭을 성취할 수 있고, 저전압 측에서는 동기정류 방식을 적용하여 도통손실을 감소시킬 수 있어 효율과 전력밀도를 더욱 향상 시킬 수 있다. 본 논문에서는 제안하는 3상 양방향 DC-DC 컨버터의 동작원리와 기존방식과의 비교분석을 수행하였으며 시뮬레이션을 통해 검증하였다.

  • PDF

A Study on the Utility Interactive Photovoltaic System using a Chopper and a PWM Inverter (쵸퍼와 PWM 전압형 인버터를 이용한 계통연계형 태양광발전시스템에 관한 연구)

  • 유택빈;성낙규;이승환;김성남;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.131-137
    • /
    • 1998
  • The solar cells should be operated at the maximum power point because its output characteristics are greatly fluctuated on the variation of insolation, temperature and load. Photovoltaic system needs an inverter which can interface the dc output power of solar cell with the residential ac load. The inverter has to supply a sinusoidal current and voltage to the load and the utility line with a high power factor. This paper proposes an utility interactive photovoltaic system designed with a step-up chopper and a PWM voltage source inverter. The step-up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power points of solar cell without any influence on the variation of insolation and temperature. The voltage source inverter operates in a manner that its output voltage is in phase with the utility voltage. The inverter supplies an ac power with high factor and low level of harmonics to the load and the utility power system.