• Title/Summary/Keyword: 축척모형실험

Search Result 98, Processing Time 0.03 seconds

Behavior of the tunnel under the influence of a existing building during the adjacent ground excavation (근접굴착 시 기존건물의 영향을 받는 터널의 거동)

  • Lee, Jong-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.609-623
    • /
    • 2018
  • If the ground is excavated in a depth which is deeper than the adjacent existing tunnel, the behavior of the braced wall is known to be greatly affected by the presence of the tunnel. By the way it is expected to be also affected by the structure on the ground surface, There are not many examples of studies which are conducted on this subject. As a result, largel scale model tests and analysis were conducted, to measure the behavior of the tunnel under the building whose location on the ground surface was varied during the adjacent ground excavation. For this purpose, the location of a building load was varied in 0 m, 1D, 2D on ground surface. In this paper, the behaviors of braced wall and adjacent tunnel was studied. Model tests in 1 : 10 scale were performed in real construction sequences. The size of test pit was $2.0m(width){\times}6.0m(height){\times}4.0m(length)$ in dimension. As a result, it was found that the stability of the existing tunnel under the influence of the building load on the ground surface adjacent to the braced wall.

Behavior of the Ground under a Building due to Adjacent Ground Excavation (근접굴착시 건물 하부 지반의 거동)

  • Lee, Jong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.4
    • /
    • pp.49-55
    • /
    • 2018
  • A pre-load of bracing was imposed to prevent the horizontal displacement on the strut of the braced wall adjacent to the building during the ground excavation. For this purpose, large scale model tests were conducted, without and with pre-load on braced wall. Adjacent building load was also imposed in different locations, that were 0 m, 1D, 2D on ground surface. In this study, model tests in 1:10 scale were performed in real construction sequences, and adjacent building was 12 m in width and the size of model test pit was 2 m in width, 6 m in height, and 4 m in length. As a result, it was found that the stability of the existing building adjacent to the braced wall within Rankine's active zone could be greatly enhanced when the horizontal displacement of the braced wall was reduced by applying a pre-load. which was larger than the designated axial force on the strut of the braced wall.

A study of estimation for excess attenuation of Noise propagated on the ground (지표면상을 전파하는 소음의 초과감쇠 산정방법에 관한 연구)

  • Oh, J.E.;Kim, D.G.;Yim, T.K.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.20-25
    • /
    • 1988
  • This study is to explain the characteristic of excess attenuation on the ground through the outdoors experiment about noise propagation and the reduced model experiment of acoustic. The outdoors experiment on the attenuation of noise propagation was tried with the small engine that had large acoustic output, and then it was conformed that there was relationship between the excess attenuation calculated by measurement from distance attenuation and Log(D/(Hs+Hr)). As a result, it was found that the attenuation of noise propogation depended upon the direction of the wind and frequency and was regressed in a straight line. And the numerical values of excess attenuation on the ground could be calculated by regarding Log(D/(Hs+Hr)) as a parameter with an airing resistance $\sigma$. It was found that when the mean square error between the excess attenuation calculated by measurement and the value calculated by a fomula $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ about optional $\sigma$ was least, the optimal decision of u was made. As the characteristic of model is the model experiment on a reduced scale of 1 to 40, It was conformed that it corresponds enough with the measurement value with measuring the distance attenuation in the large anecoic chamber.

  • PDF

Study on Air Entrainment Occurred to Intake Facility of Circular Multi Stage Cylinder Gate (원형 다단 실린더 게이트 형식의 취수시설에서 발생하는 공기연행에 대한 연구)

  • Jang, Yong;Oh, Jun Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.150-150
    • /
    • 2020
  • 본 연구에서는 수리모형실험을 통하여 원형 다단 실린더 게이트 형식의 취수시설에서 발생하는 공기연행을 분석하였다. 수리모형실험의 원형은 경상북도 청도군에 위치한 운문댐의 "운문댐 안전성 강화사업"에서 계획되고 있는 신설취수탑을 기준으로 상사법칙은 Froude상사법칙을 적용하고 1/20의 모형 축척을 가지는 취수탑의 국부모형에 하류단 수위를 고려하기 위해 유량조절시설을 설치하여 실험을 실시하였다. 실험조건은 크게 두 가지로 구분하였으며, 수면으로부터 유입구 상단부까지의 거리 ∆h1(m)과 유입부 저수지 저류 수위와 하류단 유량조절시설간의 수위차인 ∆h2(m)이며, ∆h1에 대한 조건은 0.01m~0.06m로 0.01m 간격으로 6가지, ∆h2에 대한 조건은 0.10m~1.70m로 0.20m간격으로 9가지로 이를 조합하여 총 54개 CASE에 대해 진행하였다. 실험결과 공기연행 발생 시 그에 따른 영향을 평가하기 위해 발생 정도에 따라 미발생(Not Occur), 간헐적(Intermittent), 빈번한(Frequent), 지속적(Continuation), 공기 폭발(Air Explosion)로 분류하였으며, 각 공기연행 발생 시 취수유량의 감소율 및 영향을 분석한 결과 간헐적 공기연행 발생 시 최대 약 3.75%의 취수유량 감소, 빈번한 공기연행 발생 시 취수유량은 전체적으로 10%, 최대 약 13.19% 감소하였으며, 지속적 공기연행 발생 시 발생 이후 ∆h2증가에 의한 취수유량의 증가가 거의 이루어지지 않으며, 최대 56.25%의 취수유량이 감소, 공기 폭발 발생 시 취수유량의 영향은 지속적 발생과 비슷하나 관내 공기 포집 후 유입구로 방출 시 관에 강한 충격을 주어 안정성에도 큰 영향을 미칠 것으로 판단되어, 이에 안정성 및 취수유량 감소율을 고려하여 빈번, 지속, 공기 폭발 발생 영역에서의 취수는 적합하지 않으며, 공기연행 미발생 및 간헐적 발생 영역에서의 취수 시 목표 취수유량이 1.00~4.00(㎥/s)일 때 ∆h1= 0.40m 이상, 4.00~9.30(㎥/s) 일 때 ∆h1= 0.60m 이상, 9.30~9.53(㎥/s) 일 때 ∆h1=0.80m 이상, 9.53~9.65(㎥/s) 일 때 ∆h1= 1.00m 이상에서 취수유량 감소율 3.75% 이내로 취수유량의 확보가 가능하다. 이러한 결과는 원형 다단 실린더 게이트 형식의 취수시설에 대해 취수 시 수면와류에 의한 Air Core와 그에 따른 공기연행의 발생 조건과 영향을 수리모형실험을 통해 확인함으로써 실제 운용 시 보다 안정적이고 효율적인 운용에 대한 자료로 활용될 수 있을 것으로 판단되며, 추가로 수치해석을 통한 비교 및 공기연행과 관내 공기포집 정도에 대한 연구를 통해 보다 정확한 자료제시가 가능할 것으로 판단된다.

  • PDF

A Study on the Pile Behaviour Adjacent to Tunnel Using Photo Imaging Process and Numerical Analysis (Photo Imaging Process 기법 및 수치해석을 이용한 터널주변 파일기초거동에 대한 연구)

  • Lee Yong-Joo
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.9
    • /
    • pp.87-102
    • /
    • 2005
  • In the congested urban areas, tunnelling close to existing structures or services often occurs due to the lack of surface space so that tunnelling-induced ground movements may cause a serious damage to the adjacent structures. This study focused on the two dimensional laboratory model pile-soil-tunnelling interaction tests using a close range photogrammetric technique. Testing equipments and procedures were Introduced, particularly features of aluminium rods regarded as the frictional granular material. The experimental result showed that the photo imaging process by the VMS and EngVis programs proved to be a useful tool in measuring the pile tip movements during the tunnelling. Consequently, the normalised pile tip movement data for the influence zones can be generated by the laboratory model tests using the Photogrammetric technique. This study presents influence zones associated with the normalized pile tip settlements due to tunnelling in the cohesionless material. The influence zones were Identified by both a laboratory model test and a numerical analysis. The normalized pile tip movements from the model test were in good agreement with the numerical analysis result. The influence zones proposed in this study could be used to decide the reasonable location of tunnel construction in the planning stage. However, the scale of model pile and model tunnel sizes must be carefully adjusted as real ones for practical application considering the ground conditions at a given site.

Study on the Methods for 2D Numerical Modeling of the Bridge Pier (교각의 차원 수치모의하는 방법에 2차원 관한 연구)

  • Kim, Tae-Beom;Choi, Byung-Woong;Kang, Hyeong-Sik;Choi, Sung-Uk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1737-1741
    • /
    • 2008
  • 하천 개수나 치수를 위한 기초 연구의 일환으로 수치모형을 이용한 검증 및 예측 과정이 요구되어 왔고, 고전적인 수치모의 방법으로 결과 산출이 용이한 1차원 모형을 적용시켜 왔다. 1차원 모형의 경우 모의영역을 쉽게 넓힐 수 있고, 입력 자료가 간단하다는 장점이 있지만, 수직적이고 수평적인 흐름특성 변화 및 난류 구조를 보이는 3차원적인 자연하천 흐름을 종방향의 1차원적인 모의 결과를 이용하여 평가한다는 점에서 비현실적이다. 하천을 가로질러 교각이나 보와 같은 구조물이 위치하고 있거나, 좌우 비대칭적인 형상의 수로를 모의할 경우 흐름특성의 공간적인 분포는 단순한 단면 평균적인 개념으로는 설명되기 힘들다. 최근에야 비로소 수공학 관련 실무자들에 의해서 최소한 2차원 수치모형을 기본적인 평가법으로 도입해야 한다는 분위기가 감지되고 있으며, 일반적으로 한강과 같은 대하천을 모의할 경우, 대다수의 실무자들과 연구자들이 축척을 문제 삼아 수로 내부에 위치한 교각을 생략하여 2차원 모의를 수행하기도 한다. 따라서 본 연구에서는 수로 내부에 위치한 교각을 2차원 모의하는 방법에 대한 비교 평가를 수행하고자 한다. 동일한 격자를 이용하여 교각을 고려하지 않았을 경우와 교각 형상을 모의 영역에서 삭제하여 경계처리를 하였을 경우, 마지막으로 교각이 위치하고 있는 영역에 항력을 적용하였을 경우에 대해서 비교 평가한다. 이를 위하여 2차원 천수방정식을 흐름방정식으로 하는 유한요소모형을 구축하였으며, 모형의 검증을 위해 교각이 수로에 위치할 경우에 대한 실내 실험 자료와 비교한다. 또한 검증된 모형을 이용하여 교각이 포함된 한강의 일부 구간을 선정하여, 교각 모의 방법에 대한 비교 평가를 수행한다. 본 연구에서 구축된 자료 및 제시된 수치모형은 하천복원, 치수관리 측면에서 매우 유용하게 사용될 것으로 기대된다.

  • PDF

Plane Experiments for Estimating Performance of the Sluice of Tidal Power Plant (조력발전용 수문 성능평가를 위한 평면 수리모형실험)

  • Oh, Sang-Ho;Lee, Kwang-Soo;Jang, Se-Chul;Lee, Dal-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.6
    • /
    • pp.474-481
    • /
    • 2011
  • The discharge coefficient and spatial velocity distribution were clarified by carrying out a physical experiment to assess the performance of sluice for tidal power generation. The physical experiment was performed by manufacturing 10 sluce models whose scale is 1/70 of the prototype and installing it in the planar open channel, which has apron sections in front of and behind the sluice models. In particular, it was attempted to reasonably determine the locations and method of measuring water levels that may affect estimation of the discharge coefficient. Based on the experimental results for various conditions of discharges and tidal levels, the discharge coefficient of the sluice in the experiment was estimated as 1.3 to 1.4. Meanwhile, it was found that velocities were 2~3% faster at the sluices near the central region whereas 4~5% slower at the sluices on both sides, in comparison to the average value of the mean velocities of the ten sluices.

Analysis on the Insertion Loss of a Noise Barrier by the Boundary Element Method (경계요소법을 이용한 방음벽의 삽입손실 해석)

  • 이우섭;정성수;황철호
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.423-429
    • /
    • 2000
  • This paper investigates the use of boundary element method(BEM) to analyze the insertion loss of a noise barrier. To begin with the validity of the BEm for the analysis of noise barrier insertion loss in checked by both Lam's theoretical method and the measurements in the anechoic chamber for the scale-down models. Through simulation it is shown that using 2D BEM model is sufficient to the analysis for the barrier with large ratio of length to height. By using 2D BEM model the insertion loses are predicted for the real noise barriers in several cases which are the case that they are built parallel on both roadsides the one that there are multiple sound sources and the one that there is a gap between a concrete structure and a barrier plate.

  • PDF

Noise reduction of noise barrier with noise reducer for high speed train by using scale down model test (축척모형 실험에 의한 고속전철 방음벽용 소음저감 장치)

  • 정성수;전병수;나희승;김준엽;양신추
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.647-652
    • /
    • 2001
  • A noise reduction of noise barrier for high speed train was measured by using scale down model test. A selected types of noise barriers were simple vertical barrier, interference type barrier with plate, interference type barrier with cylindrical pipes. On experiment, in order to make similar present test lane condition, reduced train model and multiple noise sources were considered. As a result. interference type noise barrier with cylindrical pipes is most effective than other barriers. A present height of noise barrier which is established in a test lane is not high enough for reducing patograph noise.

  • PDF

An Experimental Study on the Behavior of Capping Material by Sea Waves (파랑에 의한 피복재의 거동에 관한 실험적 연구)

  • Kong, Jinyoung;Kim, Youngtak;Kang, Jaemo;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.7
    • /
    • pp.51-58
    • /
    • 2014
  • In-situ capping is a method to stabilize contaminated sediments by isolation. Few researches on the in-situ capping have been performed, although the engineering approach is still required to prevent the release of contaminants. In this study, hydraulic model test were conducted by using a wave generator to observe the change of cap thickness which is important factor in design of capping. Sands with particle size between 0.075 to 2 mm as capping materials were used to observe the change of capping thickness by waves. The experimental results show that the surface of capping materials is similar to wave form. The more wave height increases, the more erosion of capping materials increases.