• 제목/요약/키워드: 축정렬

검색결과 28건 처리시간 0.032초

Straingage법에 의한 정적 상태에서의 회전체 축정렬 방법 개선 (Improvement of Rotor Axes Arrangement under the Static State by using Straingage Method)

  • 김경석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.117-122
    • /
    • 1998
  • The misalignment state causes some problems in operating. These problems such as vibration, noise, make the reduce wear, as well as, a stress concentration on the coupling which is the very weakness point at the morter. In order to align the shaft, the dialgage method has used as a means of solution until now. The method using a dialgage require a great deal of labour and money due to making by hand, the accurate alignment is not up to the expectation. For aligning the shaft, all the rotor must come to accord. Also, the dialgage method cannot be compared with straingage measurement method, from the viewpoint, which can gage in short time.

  • PDF

축정렬 불량시 베어링 특성 변화에 따른 발전소 증기 터빈의 동특성 연구 (Study of Dynamic Characteristics of Angular Misalignment of High-pressure Turbine in 1000MW Nuclear Power Plant)

  • 손석만;이준신;유기완;이선기;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.664-669
    • /
    • 2000
  • Angular misalignment is one of the important causes for shaft vibration of turbine-generator in 1000MW nuclear power plant. It may cause the plant unexpected shutdown and subsequent accident. The change of dynamic characteristics in journal bearing and rotor due to angular misalignment in high pressure turbine is analyzed. The stiffness/damping coefficients of journal bearing increase as angular misalignment. Subsequently the natural frequency of HP turbine is changed. It was found that the natural frequency may locate near 2 times operating frequency in case of severe misalignment.

  • PDF

스트레인게이지를 이용한 회전체의 축정렬 연구 (A Study on Shaft Alignment of the Rotating Machinery by using Strain Gages)

  • 나상수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.63-68
    • /
    • 1999
  • Because misaligned shafts have caused noise, vibration, bearing failures, and stress concentration of coupling part, which decrease the efficiency and life of a shaft system, the proper alignment of shaft system should be monitored continuously in dynamic condition. To solve these problems under dynamic condition, a telemetry system is this study is used to find the condition of the least bending moment, which is known by analyzing the structure and stress induced by misalignment is investigated. The moment derived from two shaft strain at the nearby coupling is measured. The bending strain is measured 5 times for average in static state as well as dynamic state with 100~700 rpm.

  • PDF

발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 간헐적 고진동 현상 규명 (Examination of the Intermittent High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant)

  • 양승헌;박철현;김재실;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.190-195
    • /
    • 2002
  • The intermittent high vibration has been occurred one or two times a day for a 500MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the intermittent high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

  • PDF

벽걸이 에어컨의 팬 진동 저감에 관한 연구 (A Study on Vibration Reduction of fan in wall-mounted air conditioner)

  • 정진태;김민성;임종혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.245-246
    • /
    • 2014
  • 에어컨의 실내기에서 발생하는 소음은 주로 회전하는 팬의 진동에 의하여 발생하게 된다. 이는 구조기인 소음으로 낮은 주파수특성을 갖고, 흡음이나 차음의 소음저감방법으로는 해결하기 어려운 특성을 가지고 있다. 본 연구에서는 벽걸이형 에어컨 원심팬에 발생하는 진동(sway motion)의 원인을 진동실험과 동역학 시뮬레이션을 통하여 규명하였다. 실험적인 측면으로는 시스템분석과 시그널분석을 통하여 원심팬 구성품의 물성치 및 동특성을 확보하였고, 해석적인측면으로는 실험으로 확보된 원심팬의 동특성을 바탕으로 동역학 시뮬레이션 모델을 수립하였다. 실험 및 동역학 시뮬레이션을 바탕으로 원심팬 진동의 원인을 규명하였고, 원심팬 진동의 원인은 원심팬과 모터축사이의 축정렬 불량임을 확인하였다. 이를 해결하고 진동을 저감하기위한 장치를 고안하고 실험을 통하여 진동저감효과를 확인하였다.

  • PDF

발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 주기적 고진동 현상 규명 (Examination of the Periodic High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant)

  • 양승헌;박철현;김재실;하현천
    • 한국소음진동공학회논문집
    • /
    • 제12권11호
    • /
    • pp.897-903
    • /
    • 2002
  • The periodic high vibration has been occurred one or two times a day for a 500 MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the periodic high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of Severe Vibration Problen of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제5권4호
    • /
    • pp.26-31
    • /
    • 2002
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbing the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often made troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-balanced representatively and/or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly in which the impeller is installed in the shaft. After clearing the trouble, the high vibration is relieved and the pump is operated smoothly. In this paper, the trouble solution shooting method of secondary cooling pump is described including the reason of high vibration

발전설비의 터빈 축정렬 (II) : 자동화를 위한 전산 프로그램 개발 (Turbine Alignment (II): Computer Program Development)

  • 황철호;김정태;전오성;이현;이병준
    • 소음진동
    • /
    • 제4권1호
    • /
    • pp.33-42
    • /
    • 1994
  • When a vibration is generated due to the misalignment, the reduction of the vibration level is not attainable unless a correct shaft alignment is conducted. In a turbine system, an alignment procedure requires quite a lot amount of expense and time. To reduce this effort, an algorithm of the turbine alignment is developed to be used in the computer program. The program consists of five parts : input, calculation, display of the results, file management, and printer output. In the input part, users must provide the data on the turbine number, the reference value of the alignment, and the number of the feet of the generator. In calculation, the moving distance of the bearing and the necessary amount of the shims are calculated. In the display and the output parts, the calculated results are displayed and calculated. In the display and the output parts, the calculated results are displayed and printed. Then, by using the file management, results and procedures conducted are saved in the floppy diskette or in the hard disk. The developed program can be run in IBM PC compatible with more than 640 KB of main memory with the operating system of MS-DOS v 3.3 or higher. It is developed for novice users with no experience or specialty in this field. The program is not only useful in the power plant application, but also helpful for recording of the alignment procedures.

  • PDF

인공수로에서의 수평 배열 헬리컬수차 현장시험 사례와 문제점 (Installation of Pilot Plant and Troubleshootings of Horizontally Linked Helical Turbines with Unconfined Free Flow Condition in Artificial Channel)

  • 강금석;김지영;이광수;명철수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.626-629
    • /
    • 2007
  • 국내외에 아직 개발 실적이 없는 발전소의 해수방류수를 이용한 조류식발전시스템의 개발을 위하여, 현재 하동화력발전소 해수방수로를 대상으로 헬리컬 수차를 이용한 조류식발전 시험설비를 제작 완료하고, 성능 시험이 진행 중이며, 본 연구에서는 성능 시험 과정에서 나타난 제반 문제점을 제시하고 그에 대한 원인 및 대책을 분석해 보았다. 본 시험설비는 인공수로에서 수평 배열 헬리컬수차로서 기계장치의 안정성 및 수차의 효율을 평가하고자 하였다. 조류식 시험장치는 배수로의 빠른 유속으로 인하여 시공이 매우 어려웠으며, 인공수로임에도 불구하고 유지관리를 위한 적정 구조 선정이 곤란한 상황이었다. 또한, 헬리컬 수차는 서로 직렬연결되어 운전할 수 있는 장점이 있으나, 본 연구와 같이 다수의 수차가 연결될 경우, 보다 높은 축정렬 정확성, 커플링, 베어링 정밀도 등이 요구되어 효율 감소의 원인이 됨을 확인하였다. 본 장치는 시험용으로서 정밀한 베어링 및 수밀구조, 증속장치를 채택하지 않았으나, 상업용에서는 이를 개선할 필요성이 있다고 판단된다. 또한, 수차의 설치와 유지관리 조건 향상, 수차 통과부의 유황 개선, 수차의 효율 향상을 위하여 조류식 수차에도 유도수로와 casing, draft tube와 같은 Confined flow 구조를 일부 채택할 필요성이 있다고 판단된다.

  • PDF

하나로 2차 냉각펌프의 고진동 해소방안 (The Solution of High Vibration of the Secondary Cooling Pump in HANARO)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.197-202
    • /
    • 2001
  • The heat produced by the fission in the fuel of HANARO, 30 MW of research reactor, was transferred from the primary cooling water to the secondary cooling water through heat exchangers. The secondary cooling water absorbed the heat was circulated by secondary cooling pumps and cooled through 33 MW of cooling tower. Each capacity of the three secondary cooling pumps was fifty percent ($50\%$) of full load. The two pumps were normally operated and the other pump was standby. One of the secondary cooling pumps has often get troubles by high vibration. To release these troubles the pump shaft has been re-aligned, the pump bearing has been replaced with new one, the shaft sleeve has been replaced with new one, the shaft and the impeller have been re-weight balanced representatively or the vibration of motor has been tested by disconnecting the shaft of pump. But the high vibration of pump cannot be cleared. We find out the weight balance trouble of the assembly that the impeller is installed in the shaft. After clearing the trouble, the high vibration is released and the pump is operated with smooth. In this paper the trouble solution of secondary cooling pump is described including the reason of high vibration.

  • PDF