• 제목/요약/키워드: 축소시편

검색결과 25건 처리시간 0.034초

축소시편 실험을 통한 공기전달음 차단성능 분석 (Analysis of airborne sound insulation performance by the experiment using small size specimen)

  • 김항;박현구;구희모;김선우
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

극소전자 디바이스를 위한 AI-1%Si 박막배선에서의 Electromigration 특성 (Electromigration Characteristics in AI-1%Si Thin Film Interconnections for Microelectronic Devices)

  • 박영식;김진영
    • 한국진공학회지
    • /
    • 제4권3호
    • /
    • pp.327-333
    • /
    • 1995
  • 전자소자의 축소화에 따라 박막배선에서의 electromigration은 점차 극소전자 디바이스의 주요 결함원인으로 부각되고 있다. 본 실험에서는 현재 박막 배선 재료로 가장 널리 사용되고 있는 AI-1%Si 금속박막배선의 electromigration에 대한 온도 및 배선길이의 의존성에 관하여 연구하였다. PSG($8000AA$)/SiO2(1000$\AA$)/AI-1%Si(7000$\AA$)/SiO2(5000$\AA$)/p-Si(100)의 보호막처리되지 않은 시편 등을 standard photolithography 공정을 이용하여 각각 제작하였다. 선폭 3$\mu$m, 길이 100, 400, 800, $\1600mu$m등의 AI-1%Si 배막배선구조를 사용하였다. 가속화실험을 위해 인가된 d.c.전류밀도는 4.5X106A/$ extrm{cm}^2$이었고 실온에서 $100^{\circ}C$까지의 분위기 온도에서 electromigration test를 진행하였다. 박막배선의 길에에 따른 MTF(Mean-Time-to-Failure)는 임계길이 이상에서 포화되는 경향을 보이며 이는 보호막층의 유무에 관계없이 나타난다. 선폭 $3\mu$m인 AI-1%Si 박막배선에서 임계길이는, 보호막처리된 시편은 $800\mu$m, 보호막처리되지 않은 시편은 $400\mu$m 배선길이에서 나타난다. 이러한 포화의 경향은 낮은 온도에서 더욱 명확해지는 특성을 보인다. 각 시편에서 electromigration에 대한 활성화에너지도 MTF의 특성과 유사하게 임계길이 이상에서 포화되는 특성을 보인다.

  • PDF

우주 안테나 설계용 형상기억 폴리머 시편의 전개 시험 (Deployment test of shape memory polymer specimens for space antenna design)

  • 구남서;레반르엉;안용산;유웅열;황진옥;박종규
    • 한국항공우주학회지
    • /
    • 제45권12호
    • /
    • pp.1007-1012
    • /
    • 2017
  • 본 연구에서는 우주 안테나 설계용 형상기억 폴리머 시편의 전개 시험을 수행하였다. Poly(cyclooctene)을 dicumyl peroxide를 이용하여 가교시켜 PCO 형상기억 폴리머를 제조하고, 이를 이용하여 지름이 120 mm인 전개형 안테나의 축소 모델을 제작하였다. 전개 성능 시험을 위하여 원형 형태의 형상기억 폴리머 시편을 반으로 접어 임시 형상을 만든 후 두 개의 히터로 형상기억 폴리머의 유리 전이 온도보다 $15^{\circ}C$ 높은 온도로 시편을 가열하였다. 먼저 시편을 수평 설치하여 전개 실험을 수행하였다. 시편의 전개 영상을 디지털 카메라를 사용하여 촬영한 후 트래커 프로그램을 이용하여 분석하였다. 중력의 효과를 최소화하기 위하여 수직 설치하여 다시 실험을 수행하였다. 두 실험의 결과를 비교하여 형상기억 폴리머 시편의 전개 성능을 고찰하였다.

축소시편을 이용한 Bottom ash 경량콘크리트패널의 차음성능평가 (An acoustic evaluation of bottom-ash light-weigh concrete panel using small-scale Panel)

  • 정진연;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.951-955
    • /
    • 2007
  • Recently, drywall's demand is increasing by interest about spread of remodeling house and separated wall structure. This research evaluated panel's SRI and found out panel properties using material of small size. Conclusion of this research is as following. First, we confirmed the effectiveness of small-scale material. Measuring results appeared equally about 400 ${\sim}$ 500 Hz that is fc frequency. Second,, it is no big difference in SRI that use CRC or magnesium board that is used for protection of panel surface. Third, it is compared SRI by used junction to make wall that become disjointing assembly. By the result, sealed wall secures resemblant SRI performance almost with normal wall. Therefore, using joint materials and sealing junction became wall that is detached with high SRI.

  • PDF

극소전자 디바이스를 위한 Al-1%Si 박막배선에서의 electromigration 특성 (Electromigration Characteristics in Al-1%Si hin Film Interconnections for Microelectronic Devices)

  • 박영식;김진영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1995년도 제9회 학술발표회 논문개요집
    • /
    • pp.48-49
    • /
    • 1995
  • 전자소자의 축소화에 따라 electromigration은 점차 반도체 디바이스의 주요 결함 원 인으로 부각되고 있다. 본 실험은 현재 배선 재료로 널리 사용되고 있는 Al-1%Si 금속박막 배선의 electromigration에 대한 온도 및 배선길이 의존성에 관하여 연구하였다. ppLCC(pplastic Leaded Chipp Carrier) ppackage된 ppSG(8000$\AA$)/SiO2(1000$\AA$)/Al-1%Si(7000 $\AA$)/SiO2(5000$\AA$)/pp-typpe Si(100)의 보호막처리된 시편과 Al-1%Si/SiO2(5000$\AA$)/pp-typpe Si(100)의 보호막처리되지 않은 시편등을 standard pphotolithograpphy 공정을 이용하여 각각 제작하였다. 선폭 3$mu extrm{m}$, 길이 100, 400, 800, 1600$\mu\textrm{m}$의 등의 Al-1%Si 박막배선구조를 사용하 였다. 가속화실험을 위해 인가된 D.C 전류밀도는 4.5$\times$106A/cm2이었고 실온에서 10$0^{\circ}C$까지 의 분위기 온도에서 electromigration를 실행하였다. 박막배선길이에 따른 MTF(Mean Time-to-Failure)는 임계길이 이상에서 포화되는 경향을 보이며 임계길이는 Al-1%Si 박막 배선에서 분위기온도에 따라 길이 400$\mu\textrm{m}$과 800$\mu\textrm{m}$범위에서 나타났다. 각 시편에서 electromigration에 대한 활성화에너지도 MTF의 특성과 유사하게 임계길이 이상에서 포화 되는 특성을 타나내었다.

  • PDF

입도조정된 조립재료의 탄성계수에 대한 연구 (Study on Young's Modulus of Coarse Granular Materials with Grain Size Distribution Adjustment)

  • 이성진;이일화;이수형;이진욱
    • 한국지반공학회논문집
    • /
    • 제29권7호
    • /
    • pp.47-55
    • /
    • 2013
  • 조립재료의 요소시험에서 장비에 허용되는 조립재료의 입자크기가 실제 현장에서 사용되는 입자크기에 비해 작은 경우가 종종 발생하기 때문에, 이러한 경우에는 시험에 사용되는 재료의 최대입경을 시험장치의 가용 크기까지 축소시켜 시험을 수행하게 된다. 본 연구에서는 이처럼 최대입경 크기를 축소시켜 입도를 조정했을 때, 저변형률에서의 탄성계수에 미치는 영향을 평가하기 위해 대형반복삼축압축시험을 수행하였다. 본 연구 대상재료의 시험 결과, 입도 조정된 시편들은 원입도 시편의 탄성계수를 과소평가하는 경향이 있었으며, 그 차이는 저변형률에서 더 크게 발생되었다.

다기능성 구조전지용 탄소섬유직물의 전해질 코팅이 기계적 성능에 미치는 효과 (The Effect of Electrolyte-coating on the Mechanical Performance of Carbon Fabric for Multifunctional Structural Batteries)

  • 박현욱;박미영;김천곤;김수현
    • Composites Research
    • /
    • 제28권5호
    • /
    • pp.285-290
    • /
    • 2015
  • 구조전지에서 멀티스케일로 일어나는 다중물리현상은 기계적 물성을 테스트하는 것을 어렵게 한다. 본 연구에서는 구조전지 셀에 적합한 기계적 물성 테스트 방법을 이용하여 탄소섬유직물의 전해질 코팅이 기계적 성능에 미치는 효과를 알아보았다. 이를 위해 ASTM의 표준 시편 규격을 참고하여 2가지 종류의 시편을 제작하였다. 기계적 물성 실험은 탄소섬유직물에 전해질을 도포하여 전해질 코팅을 수행하고 이를 다시 에폭시에 경화를 시켜 시편을 만들고 만능 인장시험기를 이용하여 인장실험을 진행하였다. 실험결과, 탄소섬유직물에 전해질의 코팅이 기계적물성에는 큰 영향을 주지 않음을 확인할 수 있었다. 또한 실험에 이용한 축소된 규격의 시편이 타당함을 확인할 수 있었다.