• Title/Summary/Keyword: 축소시편

Search Result 25, Processing Time 0.027 seconds

Analysis of airborne sound insulation performance by the experiment using small size specimen (축소시편 실험을 통한 공기전달음 차단성능 분석)

  • Kim, Hang;Park, Hyeon Ku;Goo, Hee Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2014
  • The residents' demand for the comfortable life is promoting development of wall and window which has high sound insulation performance. To develop wall system, various aspects should be considered on the environment, material, construction and structure. Especially focusing on the acoustical view, the economical solution is one of the most critical point. Recently the interest on the partition wall is being increased, because it is useful for the Rahmen type apartment which is considered as an alternative to reduce floor impact sound. This study examines simplified measurement method of airborne sound insulation applied small size specimen, in order to save money to be used for the standard specimen then to promote the development process. The results showed that the simplified method could be effective for the wall system the sound insulation performance upto Rw 50 dB, and for the judgement of rank order of sound insulation performance of the similar wall type while developing.

Electromigration Characteristics in AI-1%Si Thin Film Interconnections for Microelectronic Devices (극소전자 디바이스를 위한 AI-1%Si 박막배선에서의 Electromigration 특성)

  • 박영식;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.3
    • /
    • pp.327-333
    • /
    • 1995
  • 전자소자의 축소화에 따라 박막배선에서의 electromigration은 점차 극소전자 디바이스의 주요 결함원인으로 부각되고 있다. 본 실험에서는 현재 박막 배선 재료로 가장 널리 사용되고 있는 AI-1%Si 금속박막배선의 electromigration에 대한 온도 및 배선길이의 의존성에 관하여 연구하였다. PSG($8000AA$)/SiO2(1000$\AA$)/AI-1%Si(7000$\AA$)/SiO2(5000$\AA$)/p-Si(100)의 보호막처리되지 않은 시편 등을 standard photolithography 공정을 이용하여 각각 제작하였다. 선폭 3$\mu$m, 길이 100, 400, 800, $\1600mu$m등의 AI-1%Si 배막배선구조를 사용하였다. 가속화실험을 위해 인가된 d.c.전류밀도는 4.5X106A/$ extrm{cm}^2$이었고 실온에서 $100^{\circ}C$까지의 분위기 온도에서 electromigration test를 진행하였다. 박막배선의 길에에 따른 MTF(Mean-Time-to-Failure)는 임계길이 이상에서 포화되는 경향을 보이며 이는 보호막층의 유무에 관계없이 나타난다. 선폭 $3\mu$m인 AI-1%Si 박막배선에서 임계길이는, 보호막처리된 시편은 $800\mu$m, 보호막처리되지 않은 시편은 $400\mu$m 배선길이에서 나타난다. 이러한 포화의 경향은 낮은 온도에서 더욱 명확해지는 특성을 보인다. 각 시편에서 electromigration에 대한 활성화에너지도 MTF의 특성과 유사하게 임계길이 이상에서 포화되는 특성을 보인다.

  • PDF

Deployment test of shape memory polymer specimens for space antenna design (우주 안테나 설계용 형상기억 폴리머 시편의 전개 시험)

  • Goo, Nam Seo;Le, Van Luong;An, Yongsan;Yu, Woong-Ryeol;Hwang, Jin Ok;Park, Jongkyoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.12
    • /
    • pp.1007-1012
    • /
    • 2017
  • In this study, we performed the deployment test of shape memory polymer specimens for space antenna design. Poly(cyclootene) was cross-linked by dicumyl peroxide to make a PCO shape memory polymer. A miniature specimen with 120 mm diameter for a deployable antenna was fabricated with the PCO shape memory polymer. To investigate the deployment performance, the folded specimen as a temporary shape was heated by two heaters to the $15^{\circ}C$ higher temperature than the glass transition temperature of shape memory polymer. Firstly, the specimen was installed horizontally and tested. The deploying motion was captured by a digital camera and analyzed by a Tracker program. To reduce the effects of gravity, the specimen was installed vertically and tested again. The deployment performance of a shape memory polymer was investigated by comparing the results of horizontal and vertical installation tests.

An acoustic evaluation of bottom-ash light-weigh concrete panel using small-scale Panel (축소시편을 이용한 Bottom ash 경량콘크리트패널의 차음성능평가)

  • Chung, J.Y.;Im, J.B.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.951-955
    • /
    • 2007
  • Recently, drywall's demand is increasing by interest about spread of remodeling house and separated wall structure. This research evaluated panel's SRI and found out panel properties using material of small size. Conclusion of this research is as following. First, we confirmed the effectiveness of small-scale material. Measuring results appeared equally about 400 ${\sim}$ 500 Hz that is fc frequency. Second,, it is no big difference in SRI that use CRC or magnesium board that is used for protection of panel surface. Third, it is compared SRI by used junction to make wall that become disjointing assembly. By the result, sealed wall secures resemblant SRI performance almost with normal wall. Therefore, using joint materials and sealing junction became wall that is detached with high SRI.

  • PDF

Electromigration Characteristics in Al-1%Si hin Film Interconnections for Microelectronic Devices (극소전자 디바이스를 위한 Al-1%Si 박막배선에서의 electromigration 특성)

  • 박영식;김진영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1995.06a
    • /
    • pp.48-49
    • /
    • 1995
  • 전자소자의 축소화에 따라 electromigration은 점차 반도체 디바이스의 주요 결함 원 인으로 부각되고 있다. 본 실험은 현재 배선 재료로 널리 사용되고 있는 Al-1%Si 금속박막 배선의 electromigration에 대한 온도 및 배선길이 의존성에 관하여 연구하였다. ppLCC(pplastic Leaded Chipp Carrier) ppackage된 ppSG(8000$\AA$)/SiO2(1000$\AA$)/Al-1%Si(7000 $\AA$)/SiO2(5000$\AA$)/pp-typpe Si(100)의 보호막처리된 시편과 Al-1%Si/SiO2(5000$\AA$)/pp-typpe Si(100)의 보호막처리되지 않은 시편등을 standard pphotolithograpphy 공정을 이용하여 각각 제작하였다. 선폭 3$mu extrm{m}$, 길이 100, 400, 800, 1600$\mu\textrm{m}$의 등의 Al-1%Si 박막배선구조를 사용하 였다. 가속화실험을 위해 인가된 D.C 전류밀도는 4.5$\times$106A/cm2이었고 실온에서 10$0^{\circ}C$까지 의 분위기 온도에서 electromigration를 실행하였다. 박막배선길이에 따른 MTF(Mean Time-to-Failure)는 임계길이 이상에서 포화되는 경향을 보이며 임계길이는 Al-1%Si 박막 배선에서 분위기온도에 따라 길이 400$\mu\textrm{m}$과 800$\mu\textrm{m}$범위에서 나타났다. 각 시편에서 electromigration에 대한 활성화에너지도 MTF의 특성과 유사하게 임계길이 이상에서 포화 되는 특성을 타나내었다.

  • PDF

Study on Young's Modulus of Coarse Granular Materials with Grain Size Distribution Adjustment (입도조정된 조립재료의 탄성계수에 대한 연구)

  • Lee, Sung-Jin;Lee, Il-Wha;Lee, Su-Hyung;Lee, Jin-Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.7
    • /
    • pp.47-55
    • /
    • 2013
  • In the element test for coarse granular materials, the grain size distributions of the materials are often adjusted, in case the grain size of coarse material in the field is larger than the available maximum grain size of the laboratory test equipment. In this study, we carried out the large cyclic triaxial test to evaluate the effect of the grain size distribution adjustment on Young's modulus in small to intermediate strain level. The test results showed that the coarse granular materials with the adjusted grain size distribution underestimated Young's modulus of the original materials. The difference of Young's modulus was larger in small strain level than in intermediate strain level.

The Effect of Electrolyte-coating on the Mechanical Performance of Carbon Fabric for Multifunctional Structural Batteries (다기능성 구조전지용 탄소섬유직물의 전해질 코팅이 기계적 성능에 미치는 효과)

  • Park, Hyun-Wook;Park, Mi-Young;Kim, Chun-Gon;Kim, Soo-Hyun
    • Composites Research
    • /
    • v.28 no.5
    • /
    • pp.285-290
    • /
    • 2015
  • Multiscale multiphysics in structural batteries make mechanical property testing difficult. In this research, the effect of electrolyte-coating on the mechanical performance of carbon fabric was studied using a suitable mechanical test method for structural batteries. For this experiment, two types of specimens were determined their dimension according to ASTM. One type of specimen was smaller than the standard dimension. The specimens were coated by spreading the electrolyte material on carbon fabric, hardened using epoxy, and tested for tensile properties using universal testing machine. As a result, it was found that the mechanical properties of carbon fabric were not influenced by electrolyte coating. In addition, the small-scale specimen used in this experiment was determined to be sufficiently reliable.