• 제목/요약/키워드: 추적 가스

검색결과 130건 처리시간 0.026초

차량 추적을 위한 이동형 자동차 배출가스 측정시스템(MEL) 구축 (A Mobile Emission Laboratory for Car Chasing Experiment)

  • 이석환;김홍석;이승재;배귀남
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.109-116
    • /
    • 2011
  • To measure the traffic pollutants with high temporal and spatial resolution under real conditions a mobile emission laboratory (MEL) was designed and built in KIST with close-cooperation with KIMM and Yonsei university. The equipment of the mini-van provides gas phase measurements of CO, NOx, $CO_2$, THC (Total hydrocarbon) and number density & size distribution measurements of fine and ultra-fine particles by a fast mobility particle sizer (FMPS) and a condensation particle counter (CPC). The inlet sampling port above the bumper enables the chasing of different type of vehicles. This paper introduces the construction and technical details of the MEL and presents data from the car chasing experiment of diesel and CNG city bus. The dilution ratio was increased rapidly according to the chasing distance. Most particles from the diesel city bus were counted under 300 nm and the peak concentration of the particles was located between 40-60 nm. However, the most particles from the CNG city bus were nano particle counted under 50 nm.

방사성 추적자를 이용한 피스톤의 비정상 온도 특성에 관한 연구 -피스톤 링 갭 위치와 블로우 바이 가스의 영향- (The Investigations of the Characteristics of Unsteady Piston Temperature Using Radiotracers-The Effect of Piston Ring Gap Position and Blow By Gas)

  • 김중수;김승일;민병순;박승일;오대윤;정성희;진준하
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-9
    • /
    • 2000
  • To understand the thermal characteristics around the piston ring gap ring gap positions and piston temperatures are measured simultaneously. The locations of piston ring gap are measured by the radio-tracer method and piston temperature are measured by a K-type thermocouple and scissors type linkage system. From these experiments following facts are clarified. Piston temperatures fluctuate according to the piston ring rotation. And the temperature fluctuation is mainly affected by top ring gap position irrelevant to the second ring fop position. If the top ring gap position increases and the temperature of top ring groove shows maximum value when top rin gap position coincide with temperature measuring point. The maximum amplitude of temperature fluctuation which is proportional to the blow by gas rate is around 12-15$^{\circ}C$.

  • PDF

추적가스를 이용한 실간환기량 산정방법에 따른 불확실성 해석 (Uncertainty Analysis of Interzonal Airflow Rates by Tracer Gas Methods)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.529-534
    • /
    • 2008
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

  • PDF

건축공간에서 공기 감염균 확산을 해석하기 위한 추적가스 고찰과 농도에 따른 감염 위험성 예측 연구 (A Inquiry of Tracer Gas for Analysis of Dispersion and Prediction of Infection Possibility according to Airborne Viral Contaminants)

  • 임태섭;강승모;김병선
    • 한국실내디자인학회논문집
    • /
    • 제18권3호
    • /
    • pp.102-113
    • /
    • 2009
  • The SARS virus began to appear and spread in North America and Southeast Asia in the early 2000' s, infecting and harming many people. In the process of examining the causes for the virus, studies on the airborne SARS virus and the way it spread were carried out mainly in the medical field. In the field of architecture, studies were done on the diffusion of air pollutants in buildings using gases such as $CO_2$, $N_2O$, or $SF_6$, but research on virus diffusion was limited. There were also explanations of only the diffusion process without accurate information and discussion on virus characteristics. The aim of this study is to analyze the physical characteristics of airborne virus, consider the possibility of using coupled analysis model and tracer gas for analyzing virus diffusion in building space and, based on reports of how the infection spread in a hospital where SARS patients were discovered, analyze infection risk using tracer gas density and also diffusion patterns according to the location, shape, and volume of supply diffusers and exhaust grilles. This paper can provide standards and logical principles for evaluating various alternatives for making decisions on vertical or horizontal ward placement, air supply and exhaust installation and air volumes in medium or high story medical facilities.

실간환기량 측정을 위한 추적가스 실험방법론에 관한 연구 (A Study on Tracer Gas Methodology to Measure Interzonal Airflow Rates)

  • 한화택;조석효
    • 설비공학논문집
    • /
    • 제21권11호
    • /
    • pp.606-612
    • /
    • 2009
  • Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Tracer gas techniques are widely used to measure ventilation rates, ventilation effectiveness, and interzonal air movements. Depending on the number of gases used, they are divided into single and multi tracer gas methods. This paper deals with the comparison of the tracer gas methods in measuring air exchange rate between rooms. Experiments have been conducted in a simple two-room model with known airflow rates. In multi-gas procedure, the concentration decays of two tracer gases, i.e SF6 and R134a are measured after simultaneous injections in each room. The single tracer gas method is also applied by injecting SF6 gas with a time lag between two rooms. The data reduction procedures are developed to obtain the interzonal airflow rate using the matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, and smoothing. Uncertainty for each airflow rate is investigated depending on the parameters based on the setting values.

실간환기량 측정을 위한 멀티추적가스법의 검증실험 (An Experiment on Verification of Multi-Gas Tracer Technique for Air Exchange Rate Between Rooms)

  • 한화택;조석효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.99-104
    • /
    • 2007
  • Tracer gas technique is widely used to measure the ventilation rates and/or ventilation effectiveness of building spaces. However, the conventional method using a single tracer gas can measure only outdoor air change rates in a single zone. This paper deals with the multi-gas tracer technique to measure air exchange rates between rooms. Interzonal air movements are important to characterize overall ventilation performance of complicated multi-zone buildings. Experiments are conducted in a simple two-room model with known airflow rates using tracer gases of SF6 and R134a. The concentration decays of two tracer gases are measured after simultaneous injections in each room. The governing equations are derived from the continuity and the mass balance of each room. The data reduction procedure are developed to obtain the inter-room airflow rates using the governing matrix inversion, and various data manipulation methods are tested, such as data shift, interpolation, smoothing, and etc, to improve the estimate and interpretation of the results.

  • PDF

센서네트워크 데이터를 이용하여 독성물질 누출속도를 예측하기 위한 신경망 기반의 역추적방법 연구 (A Neural Network-Based Tracking Method for the Estimation of Hazardous Gas Release Rate Using Sensor Network Data)

  • 소원;신동일;이창준;한종훈;윤인섭
    • 한국가스학회지
    • /
    • 제12권2호
    • /
    • pp.38-41
    • /
    • 2008
  • 본 연구에서는 독성가스 중 가장 널리 이용되는 염소와 암모니아 가스 누출에 대한 누출속도 추정 방법을 제안하고자 한다. 우선, 독성 가스 누출이 자주 발생하는 위험 지역 주변에 펜스 형태의 광센서 네트워크를 설치한다. 센서가 규정 농도 이상의 위험물질을 감지하게 되면, 자동적으로 물질을 분석하고 그 물질의 농도정보를 얻게 된다. 기존의 역추적 모델들은 3개 이상의 센서 정보로부터 결과물을 요구하기 때문에, 하나의 센서정보로 누출속도를 구해야 하는 이 시스템에는 적합하지 않다. 이 연구에서 제안한 신경망을 기반으로 한 역추적 알고리즘과 농도정보 및 기상정보를 이용하여 누출원에서 누출속도를 구하게 된다. 관련 위험물 저장 설비의 공정정보, 물질정보, 기상정보 그리고 센서로부터 얻은 농도데이터 등 14개의 입력 데이터를 넣어 출력값인 누출속도를 구하게 된다. 이는 독성가스 저장시설 주변에 사는 주민들에게 위험시설에 대한 신뢰감을 향상시키며, 독성 가스 누출시 주변 지역 주민들에게 긴급상황을 신속히 전달할 수 있는 비상대응의 일환으로 활용 할 수 있을 것이다.

  • PDF

화학물질 저장시설의 사고대응 및 훈련을 위한 로봇기반 누출감지 및 추적시스템 (Mobile Robot-based Leak Detection and Tracking System for Advanced Response and Training to Hazardous Materials Incidents)

  • 박명남;김창완;김태옥;신동일
    • 한국가스학회지
    • /
    • 제23권2호
    • /
    • pp.17-27
    • /
    • 2019
  • 화학물질의 사용 증대와 더불어 위험물 및 독성가스 누출 사고가 빈번하게 일어나고 있다. 그 중에서도 위험물 저장설비 사고는 누출이 감지되었을 때 대응하기 위한 초동 조치가 가장 중요하지만, 전적으로 조업자에 의한 경험에 비중이 크기 때문에, 잘못된 판단으로 인한 더 큰 물적, 인적 피해가 발생할 가능성이 높다. 본 연구는 기존 고정식 감지기를 통한 알람 발생 후 수동적인 대응을 취하는 현 접근 방식에서 벗어나, 오픈소스기술을 적용하여 쉽게 제작이 가능한 로봇 플랫폼에서 작동하는 이동식 센서를 활용한 능동적인 누출원 추적 시스템을 설계하였다. 아울러 프로토타입 시스템의 검증을 통해 누출 초기의 정확한 현장 상황파악 및 조기대응을 바탕으로 사고의 확산 및 피해 최소화의 기틀을 마련하고자 하였다.

센서 네트워크에서 연속적인 개체 추적을 위한 동적 직사각형 영역 기반 협동 메커니즘 (Dynamic Rectangle Zone-based Collaboration Mechanism for Continuous Object Tracking in Wireless Sensor Networks)

  • 박보미;이의신;김태희;박호성;이정철;김상하
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제15권8호
    • /
    • pp.591-595
    • /
    • 2009
  • 센서 네트워크에서 개체 검출과 추적에 관한 기존 라우팅 프로토콜들은 사람, 동물, 차량 등과 같은 하나 또는 그 이상의 단일(individual) 개체들에 대한 검출과 추적을 하기 위한 방법에만 관심을 가질 뿐, 독가스, 생화학물질 등과 같은 연속적인 개체들을 검출하고 추적하는 프로토콜들은 많지 않다. 이러한 연속적인 개체들은 어느 지역에 계속적으로 분산되어 있고, 광범위한 지역을 차지한다는 점에서 단일 개체들과 차이가 있다. 따라서 많은 센서 노드들에 의해 검출되고 센싱되는 데이터들은 중복적이고 서로 깊이 관련되어 있다. 그러므로 지역적으로 센싱 데이터를 수집하고 통합하여 데이터를 보고하기 위한 효율적인 방안이 필요하다. 본 논문에서 우리는 연속적인 개체들을 검출, 추적하고 모니터링(monitoring)하기 위한 동적인 직사각형 영역에 기반한 연속적인 개체 추적 방안을 제안한다. 제안된 방안은 하나의 연속된 개체가 차지한 지역이 포함된 동적인 직사각형 영역을 구성하고, 영역에서 하나의 대표 노드가 연속된 개체를 검출하는 센서 노드들로부터 센싱 데이터를 수집하고 통합한다.

화재로 인한 HCN 가스에 노출된 마우스의 병리학적 관찰 및 단세포 전기영동법을 사용한 DNA 변성 추적에 관한 연구 (A Study on DNA Degeneration by Comet Assay & Pathological Observation for Mouse Which were Exposed HCN Gases from Fire)

  • 조남욱;오은하;황성규
    • 한국가스학회지
    • /
    • 제16권6호
    • /
    • pp.7-16
    • /
    • 2012
  • 화재시 당면할 수 있는 위험성의 여러 인자 가운데 연소 독성 영향은 피난 및 최종 생존에 중요한 영향을 미치고 있다. 화재 독성에 지금까지 대한 대부분의 연구는 치사 측면에 국한되어 왔다. 이에 본 연구에서는 대표적인 질식성 가스인 HCN을 대상으로 가스유해성시험방법(KS F 2271)을 통하여 실험동물(흰쥐)에 직접 독성가스를 흡입시킨 후 평균행동정지시간을 측정하고, 이들 실험동물군의 내부 장기 변화, 혈액학 분석 및 단세포전기영동분석을 통해 연소 독성가스가 생체에 미치는 영향을 정량적으로 분석하고자 하였으며, 기존 가스유해성시험에서 확인할 수 없었던 접근(병리검사, 혈액검사, 혈액생화학검사, 단세포전기영동분석)을 통해 연소 독성학 분야의 생물학적 위험도를 측정하고자 하였다.