• Title/Summary/Keyword: 최종압력하중

Search Result 29, Processing Time 0.034 seconds

Buckling of Filament Wound Thick Composite Cylinders under External Hydrostatic Pressure (외부 수압을 받는 필라멘트 와인딩 후판 복합재 원통의 좌굴 연구)

  • Moon, Chul-Jin;Hur, Seong-Hwa;Ahn, Jung-Hee;Kweon, Jin-Hwe;Choi, Jin-Ho;Cho, Jong-Rae;Cho, Sang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.147-155
    • /
    • 2009
  • The buckling and failure of filament wound thick composite cylinders under external hydrostatic pressure were investigated by the finite element analysis and test. ACOS, MSC.NASTRAN, and MSC.MARC were used for finite element analysis. T700 carbon-epoxy filament wound composite cylinders were fabricated to have winding angles of $[\pm30/90]_{FW}$, $[\pm45/90]_{FW}$, $[\pm60]_{FW}$, $[\pm60/90]_{FW}$, and tested to verify the finite element analysis. Among the softwares, ACOS predicted buckling load the best with about 1.7~14.3% deviation from test. Analysis and test shows cylinders do not recover the initial buckling pressure after buckling and directly lead to final failure.

Analysis of Filling and Stresses in the Hot Forging Process Depending on Flange Die Shapes (열간단조 플랜지 금형의 형상에 따른 충전 및 응력해석)

  • Kim, Jun-Hyoung;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.4
    • /
    • pp.423-430
    • /
    • 2010
  • Hot closed-forging process and the die used for forming an automotive flange were analyzed from the viewpoints of heat transfer, grain-flow lines, and stresses to obtain a forged product without defects such as surface cracks, laps, cold shots, and partial filling. The forging process including up-set, pre-forging, final forging and pressing forces was investigated using finite element analysis. The influence of the preform die and the ratio of the heights of the upper die to lower die on the forging process and die were investigated and a die shape ($10^{\circ}$ for the preform die, and 1.5:1 ratio for the final die) suitable to achieve successful forging was determined on the basis of a parametric study. All parametric design requirements such as strength, full filling, and a load limit of 13,000 KN were satisfied for this newly developed flange die. New dies and flanges were fabricated and investigated. Defects such as partial filling and surface cracks were not observed.

Prediction of the Damage Zone Induced by Rock Blasting Using a Radial Crack Model (방사균열 모델을 적용한 암반 발파에 의한 손상 영역 예측)

  • Sim, Young-Jong;Cho, Gye-Chun;Kim, Hong-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.11
    • /
    • pp.55-64
    • /
    • 2006
  • It is very Important to predict the damage zone of a rock mass induced by blasting for the excavation of an underground cavity such as a tunnel, as the damage zones incur mechanical and hydraulic instability of the rock mass potentially. Complicated blasting processes that can hinder the proper characterization of the damage zone can be effectively represented by two loading mechanisms. The first mechanism is the dynamic impulsive load-generating stress waves that radiate outwards immediately after detonation. This load creates a crushed annulus along with cracks around the blasthole. The second is the gas pressure that remains for an extended time after detonation. As the gas pressure reopens some arrested cracks and extends these, it contributes to the final structure of the damage zone induced by the blasting. This paper presents a simple method to evaluate the damage zone induced by gas pressure during rock blasting. The damage zone is characterized by analyzing crack propagations from the blasthole. To do this, a model of a blasthole with a number of radial cracks that are equal in length in a homogeneous infinite elastic plane is considered. In this model, crack propagation is simulated through the use of only two conditions: a crack propagation criterion and the mass conservation of the gas. The results show that the stress intensity factor of a crack decreases as the crack propagates from the blasthole, which determines the crack length. In addition, it was found that the blasthole pressure continues to decrease during crack propagation.

Effect of Construction Joint on Leakage Resistance of Gas in Reinforced Concrete Pressure Vessels (철근콘크리트 압력용기에서 시공이음이 가스의 누설저항에 미치는 영향)

  • Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • In the nuclear power plant, the steel or polymer liner plates are adopted to prohibit the inner concrete surface from contacting with gas or liquid materials. If there is an accident, the plate may be damaged, and, in this case, concrete shall have the final responsibility to safety requirements. In this paper, an experimental research was carried out to investigate the effects of construction joint and wet and loading conditions on the permeability of concrete. The test results showed that, under a construction joint in the wet condition, leakage of gas pressure has been started from $1kg/cm^2$. However, when there are no construction joints, it is initiated from $2kg/cm^2$. In addition, under the air dried and unloading condition, regardless of with or without the presence of the construction joint, since the gas passage that exist in concrete is constant, leakage has a constant tendency to increase. Finally, under the loading condition, as described in Reference 1, since leakage is inversely proportional to the thickness of the wall, and, considering the wall thickness of the actual plant, it is found that there will not be no problem in the sealing of the gas.

Development of Ankle Power Assistive Robot using Pneumatic Muscle (공압근육을 사용한 발목근력보조로봇의 개발)

  • Kim, Chang-Soon;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.771-782
    • /
    • 2017
  • This paper describes the development of a wearable robot to assist ankle power for the elderly. Previously developed wearable robots have generally used motors and gears to assist muscle power during walking. However, the combination of motor and reduction gear is heavy and has limitations on the simultaneous control of stiffness and torque due to the friction of the gear reducer unlike human muscles. Therefore, in this study, Mckibben pneumatic muscle, which is lighter, safer, and more powerful than an electric motor with gear, was used to assist ankle joint. Antagonistic actuation using a pair of pneumatic muscles assisted the power of the soleus muscles and tibialis anterior muscles used for the pitching motion of the ankle joint, and the model parameters of the antagonistic actuator were experimentally derived using a muscle test platform. To recognize the wearer's walking intention, foot load and ankle torque were calculated by measuring the pressure and the center of pressure of the foot using force and linear displacement sensors, and the stiffness and the torque of the pneumatic muscle joint were then controlled by the calculated ankle torque and foot load. Finally, the performance of the developed ankle power assistive robot was experimentally verified by measuring EMG signals during walking experiments on a treadmill.

Study on Analysis for the Slope Monitoring Performance at the Whangryeong Mountain Site (황령산 사면 계측관리 분석에 관한 연구)

  • La Won Jin;Choi Jung Chan;Kim Kyung Soo;Cho Yong Chan
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.429-442
    • /
    • 2004
  • Landslide of the Whanpyeong Mountain which was occurred at Busan Metropolitan City in 1999 belongs to the category of plane failure. Automatic monitoring system to measure horizontal displacement, pore pressure change and load change has operating from reconstruction stage for evaluating rock slope stability (August, 2000$\~$Feburuary, 2002). As a result of the analysis on the monitoring performance data, it is suggested that infiltrated rain water from pound surface discharges rapidly through cut-slope because pressure head of water decreases rapidly after rainfall while rise of pore pressure is proportional to the amount of rain water. As a result of data analyses for inclinometers and load cells, it seems that slope is stablized be cause ground deformation is rarely detected. The areas especially similar to the study site where landslide is induced by heavy rain fall, change of pore pressure is rapidly analyzed using automatic monitoring system. Therefore, it is considered that automatic monitoring system is very effect for slope stability analysis on important cut-slopes.

[ $C^{\ast}$ ]-integral Based Life Assessment of High Temperature Pipes ($C^{\ast}$-적분에 기초한 고온배관 수명평가)

  • Lee Hyungyil
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.25-33
    • /
    • 2000
  • In recent years, the subject of remaining life assessment has drawn considerable attention in power plants, where various structural components typically operate at high temperature and pressure. Thus a life prediction methodology accounting for high temperature creep fracture is increasingly needed for the components. Critical defects in such structures are generally found in the form of semi-elliptical surface crack, and the analysis of which is consequently an important problem in engineering fracture mechanics. On this background, we first develop an auto mesh generation program for detailed 3-D finite element analyses of axial and circumferential semi-elliptical surface cracks in a piping system. A high temperature creep fracture parameter $C^{\ast}$-integral is obtained from the finite element analyses of generated 3-D models. Post crack growth module is further appended here to calculate the amount of crack growth. Finally the remaining lives of surface cracked pipes for various analytical parameters are assessed using the developed life assessment program.

  • PDF

Analysis of dynamic downpull force on the underflow type floating gate with its shape (부력식 수문의 형상에 따른 동적 하향력 분석)

  • Lee, Ji Haeng;Choi, Jong Geun;Choi, Heung Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.42-42
    • /
    • 2019
  • 유량조절을 위한 자동수문은 설정된 관리수위 이하에서는 수문이 개방되지 않으며, 유량이 증가하여 관리수위 이상이 되면 수문이 개방되어 방류를 시작하여 일정 수위를 유지하는 것을 의미한다. 자동수문의 운영 중 수문의 거동과 자동 개폐 시점을 예측하는 것은 정밀한 수문 설계를 위해 매우 중요하다. 수문 하단으로 흐름이 발생하면 수문 선단을 포함한 주변에서의 압력 차이로 인한 동수압 하중이 발생하고 진동을 유발, 수문 개방을 억제하는 하향력 등의 효과로 수문 운영에 큰 영향을 미친다. 본 연구에서는 부력식 수문의 모형실험을 통하여 정수압 상태의 부력 이론에 의한 수문 개방률과 측정에 의한 수문 개방률을 비교하였으며, 이론과 측정 수문 개방고의 차이를 하향력에 의한 효과임을 확인하였다. 부력식 수문의 하향력을 검토하기 위해 기존 이론식을 이용한 결과, 이론식은 부력식 수문에 적용하기 어려운 것으로 나타났다. 따라서, 기존 이론식을 이용하여 부력식 수문의 하향계수 산정을 위한 매개변수 관계식을 개방률을 이용하여 제시하였다. 제시된 매개변수 관계식의 결정계수는 0.721, 수정된 결졍계수는 0.690으로 나타났다. 부력식 수문의 형상비에 따른 하향력을 검토하기 위해서 수치모의를 수행하였다. 모형실험에서 측정된 자료와 수치모형 ANSYS-Fluent의 사용성을 검증하였고, 부력식 수문의 형상비를 0.24, 0.49, 0.69, 0.89, 1.09로 총 5가지로 설정하여 하향계수와 하향력을 분석하였다. 부력식 수문의 하향계수와 하향력 검토는 부력체, 스커트로 구분하여 분석을 수행하였다. 하향계수 분석결과, 하향계수는 개방률이 증가함에 따라 감소하였으며 하향계수가 부력체 부분에서는 0.465~1.542, 스커트 부분에서는 0.058~1.148의 범위로 나타났다. 하향력 분석결과, 하향력은 개방률 0.300 이하에서는 개방률이 증가함에 따라 하향력은 증가하였나 개방율 0.300 초과하면서부터 개방률이 증가함에 따라 하향력이 감소하는 것으로 나타났다. 또한 부력체 부분에서는 형상비가 증가함에 따라 하향력이 감소하였으나, 스커트 부분에서는 형상비가 증가함에 따라 하향력이 증가하였다. 이는 형상비가 증가함에 따라 스커트 부분의 면적이 증가하기 때문이다. 부력식 수문의 전체적인 하향력을 계산한 결과, 부력식 수문의 하향력은 0.002~0.015 kN의 범위를 가지며 형상비가 증가함에 따라 부력식 수문에 발생하는 하향력은 증가하는 것으로 나타났다.

  • PDF

Electrical Properties of Piezoelectric Generator Fabricated with PNN-PZT Ceramic (PNN-PZT 압전 세라믹을 이용하여 제작한 발전소자의 전기적 특성 평가)

  • Lee, Myung-Woo;Kim, Sung-Jin;Yoon, Man-Soon;Ryu, Sung-Lim;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.190-190
    • /
    • 2008
  • 자연적으로 발생되는 파도, 비, 우박 등과 철도, 차량 및 엘리베이터 등과 같은 인위적인 설치, 이동에 의해 발생되는 진동에너지는 우리 일상생활에서 가장 흔하게 발생할 수 있는 에너지원인데, 이러한 진동에너지는 압전 소재를 이용하여 재생 가능하여 최근에는 이에 대한 연구가 활발히 진행되어 왔다. 예를 들면, 미국의 MIT에서는 인간이 걸을 때 신발에 가해지는 압력을 이용하여 전력을 발생시키는 연구를 진행하여 2.9 mW의 전력을 얻었다. 특히 이러한 기술은 인간의 걷기 운동 등과 같은 일상적인 동작으로 필요한 전력을 얻을 수 있고, 세라믹 소자를 이용하기 때문에 전자노이즈가 발생되지 않을 뿐 아니라 반영구적으로 사용할 수가 있어서, 소형 전자기기 등에 서 기존 이차전지를 대체 또는 보완 할 수 있는 기술로 검토되고 있다. PZT계 세라믹스는 높은 유전상수와 우수한 압전특성으로 이러한 압전발전 분야에서 가장 널리 사용되어지고 있다. 하지만 에너지 효율을 높이기 위하여 적층 구조의 제작 시 구조적 특성상 내부전극이 도포된 상태에서 동시 소결이 필요한데, $1000^{\circ}C$ 이상의 높은 소결온도 때문에 소재 원가가 낮은 Ag전극 대신 값비싼 Pd나 pt가 다량 함유된 Ag/Pd, Ag/Pt 전극이 사용되고 있어 경제성이 떨어지는 단점을 갖게 된다. 순수 Ag 전극을 사용하거나 Ag의 비율이 높은 내부전극을 사용하기 위해서는 $900^{\circ}C$ 이하에서 소결되고 우수한 전기적 특성을 보이는 압전 세라믹스 소재를 개발 하는 것이 필요하다. 따라서 본 연구에서는 압전특성이 우수한 $(Pb_{1-x}Cd_x)(Ni_{1/3}Nb_{2/3})_{0.25}(Zr_{0.35}/Ti_{0.4})O_3$ 계의 조성을 설계하고, 소결온도를 낮추기 위해서 2 단계 하소법을 이용하였다. 또한 $MnCO_3$, $SiO_2$, $Pb_3O_4$ 등을 소랑 첨가하여 액상 소걸 특성을 부여하여 소결 온도를 감소시키려는 시도도 하였다. 소결체의 전체적인 제조 공정은 일반적인 벌크 세라믹의 소걸 공정을 따랐다. 최종 소결된 시편을 XRD분석을 통하여 상을 확인하였고 SEM을 이용하여 미세조직을 관찰 하였다. 전기적 특성을 평가하기 위하여 두께를 1mm로 연마한 시편에 Ag 전극을 도포하여 $650^{\circ}C$ 에서 열처리한 후, 분극처리 하였다. Impedance analyzer를 이용하여 압전 특성 (전기기계결합계수 및 기계적품질계수)을 측정 하였고, 압전전하상수는 $d_{33}$-meter로 측정하였다. 본 연구에서는 압전체에 가해지는 하중의 크기, 시편의 크기, 하중을 가하는 방법, 에너지 저장회로의 최적화 등을 다양하게 시도하면서 에너지 변환 및 저장 효율을 평가하였다.

  • PDF