• Title/Summary/Keyword: 최적 콘크리트 배합

Search Result 214, Processing Time 0.03 seconds

An Experimental Study for the Strength Variations of High-strength Lightweight Concrete According to Grain-size of Artificial Lightweight Aggregate (인공경량골재의 입도에 따른 고강도 경량콘크리트의 강도변화에 대한 실험적 연구)

  • Kim, Sung Chil;Park, Ki Chan;Choi, Hyoung Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.209-217
    • /
    • 2011
  • In recent days, while taller and more massive structures such as huge bridges and super skyscrapers have been welcomed, the structural stabilization in design and construction have been gradually limited due to the major weakness of current concrete which is relatively heavier when compared with its strength. To improve the weakness of the current concrete, The lightweight concrete with light weight and high strength should be used; however, not many researchers in Korea have studied on the lightweight concrete. Generally, artificial lightweight aggregate produced through high-temperature-plasticization has a possibility of its body-expansion with many bubbles. Therefore, depending on the size of aggregate, the effects of bubbles on the specific weight and strength of the lightweight concrete should be studied. In this study, considering grain-size, the mix design of the artificial lightweight aggregate produced through the high-temperature-plasticization and the body-expansion of waste and clay from the fire power plant in Korea was conducted. The experiment to analyze the variation in specific weight and strength of the lightweight concrete was followed. From these experiments, the optimized grain-size ratio of the artificial lightweight aggregate for the enhancement of high-strength from the lightweight concrete was revealed.

Experimental Study on High Strength and high Flowable Concrete Filled Steel Tube for Practical Construction Application (합성강관 충전용 고강도-초유동 콘크리트의 현장적용을 위한 실험적 연구)

  • 윤영수;이승훈;성상래;백승준
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.2
    • /
    • pp.151-161
    • /
    • 1996
  • This paper presents a series of tests to produce the h~gh quality concrete to be filled Inside the steel tube columns. Thls concrete filled steel tube system requires not only the high strength, but a150 the flowable concrete. Laboratory test has been performed to clarlfy the material characteristics and to produce the optlmal mix design proportion. Full scale site mock up test has been then carried out to slnlulate the actual construct~on conditions including the product~on of concrete at the rermcon batch plant, transportation to the construction site, proper workabil~ ty and man power required , 4ddit1onal mock up test has finally been performec to irivesti gate any unfavorable construction s~tuatioils since the actual concrete placement has been sched uled in cold weather period, so that the high quality concrete construction is convinced to be successfully carried out.

The Selection of Optimal Mixing Proportion and Cost Analysis in the SFC (초유동 콘크리트의 최적배합 선정방법 및 경제성 분석)

  • Park, Chil-Lim;Kim, Moo-Han;Kwon, Yeong-Ho;Lee, Sang-Soo;Won, Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.262-268
    • /
    • 1998
  • This research is to examine the selected method of optimal mixing proportion and cost analysis in the super flowing concrete. As confined water $ratio($\beta_p$)$ and K is introduced, itis to establish optimal mixing design of super flowing concrete according to the steps of paste, mortar and concrete. From paste and mortar test, it was led to $$\beta_p$$ and $K_p$satisfying the optimum condions depending on the kinds of binders. Then $$\beta_p$$ and $K_p$ is reflected to the mix condition of super flowing concrete. The result of test, the mix condition of super flowing concrete satisfied the quality performance of concrete with adjustment of additional rate of the superplasticizer. Besides, in case of design strength $350kg/\textrm{cm}^2$ of concrete, material cost in super flowing concrete is able to be reduced 5~16% in replacement of fly ash 30% in ordinary portland cement and slag cement.

  • PDF

Optimal Mix Proportion of Steel Fiber and Hybrid Fiber Reinforced Concrete Using Harmony Search (화음탐색법을 이용한 강섬유 및 하이브리드 섬유보강 콘크리트의 최적배합 설계)

  • Lee, Chi-Hoon;Lee, Joo-Ha;Yoon, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.280-283
    • /
    • 2004
  • Today, the guide line of the SFRC mix design and the construction was not embodied, and the convenience of the practical application on the spot is not good. In this research, hence, the program which is optimized to result the mix proportion by the flexural strength and toughness, was developed to apply with ease SFRC on the practical spot. This program would minimize the number of trial mixes and achieve an economical and appropriate mixture. In addition, the theoretical background on which the program is based, will be the basis of the embodied method to mixing SFRC. New algorithm, in this research, was used to develop the mix proportioning program of SFRC. The new algorithm is the Harmony Search which is the heuristic method mimicking the improvisation of music players. And, beside to single fiber reinforced concrete, it was developed the program about the hybrid fiber reinforced concrete that two kinds of steel fibers, which have the different geometry, was reinforced. This will be able to keep the world trend to study, hence, offers the basis of the next generation research.

  • PDF

Selection of Optimal Mixture of Limestone Cement Paste by Using the Design of Experiment (실험계획법을 이용한 석회석 시멘트 콘크리트의 최적배합 선정)

  • Kim, Geon-Woo;Kim, Jin-Man;Choi, Sun-Mi;Kim, Beom Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.107-108
    • /
    • 2021
  • In the global trend of countries around the world announcing the declaration of carbon neutrality, the development of low-carbon cement in the cement industry can be seen as a very important issue that can determine the future development of the cement industry in the future. Therefore, this study evaluated the strength characteristics of limestone cement paste with limestone powder of CaCO3 and refinery desulfurization waste catalyst of high Al2O3 content, and using a Minitab mixture design to optimize a limestone cement content. As a resuls it was confirmed that limestone cement paste with 5-10% of limestone powder and 1.25-2.5% of the waste catalyst exhibits similar compressive strength to that of OPC.

  • PDF

Experimental Study on the Effects of Mineral Admixtures on the Fluidity and Strength Characteristics of High-Performance Concrete (고성능 콘크리트의 유동성 및 강도에 대한 혼화재의 영향에 관한 실험연구)

  • Oh, Byung Hwan;Um, Joo Yong;Lim, Dong Hwan;Park, Sang Hyun;Cha, Soo Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.783-794
    • /
    • 1994
  • Recently, several failure cases of concrete structures during construction have been reported. The main reason for these failures is attributed to the poor quality of concrete during construction. It is, therefore. necessary to develop and use high quality concrete. The purpose of the present study is to explore the characteristics of superplasticized concrete, especially the effects of mineral admixtures on the fluidity and strength characteristics of high performance concrete. The mineral admixtures considered in the present study are fly ash, blast furnace slag and silica fume, respectively. The major test variables include the amount of these mineral admixtures, cement contents and water-cement ratios. The compressive strengths for various cases were measured and reported. Optimum contents of mineral admixtures for strength development were derived. The corrosion phenomena of reinforcements embedded in various concrete specimens have been also studied. The present study provides useful basis to apply high-performance concrete to actual structures.

  • PDF

Experimental Study on the Application of Concrete Admixture using the EAF Reduction Slag (전기로 환원 슬래그 미분말의 콘크리트용 혼화재 적용성에 관한 실험적 연구)

  • Choi, Jae-Seok;Jang, Pil-Sung;Jo, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6890-6897
    • /
    • 2014
  • EAF reduction slag has unstable properties of expansion and destruction. Therefore, it cannot be used as a construction material. The purpose of this study was to use EAF reduction slag as a concrete admixture. EAF reduction slag contains $11CaO{\cdot}7Al_2O_3{\cdot}CaF_2$ and ${\beta}-C_2S$ (calcium aluminate compounds). To confirm the properties of EAF reduction slag as a concrete admixture, the condensation, compressive strength and activity factor due to substitution rate of EAF reduction slag were measured. Originally, EAF reduction slag was cured rapidly because of its chemical composition ($11CaO{\cdot}7Al_2O_3{\cdot}CaF_2$). On the other hand, when 8% gypsum was added, its properties of condensation and compressive strength were similar to the plain specimen. When 6% gypsum was added, the quality of the KS F 2536 standards (quality standard number 3) were met in terms of activity factor. Overall, 8% gypsum addition is the most appropriate by considering the activity factor in the long-term compressive strength.

Mechanical characteristics of high-performance concrete shield segment containing ground granulated blast furnace slag and their improvement by steam curing (고성능 쉴드 세그먼트용 고로슬래그 미분말을 혼입한 콘크리트의 역학적 특성 및 증기양생 효과 분석)

  • Kim, Byoung-Kwon;Lee, Jin-Seop;Lee, Gyu-Phil;Chang, Soo-Ho;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.233-242
    • /
    • 2011
  • This study aims to evaluate the applicability of high-strength concrete mixed with blast furnace slag to shield segment lining in order to improve its performance and economic efficiency. Especially, it was also intended to derive the optimum replacing ratio of ground granulated blast furnace slag to ordinary cement as well as the optimum steam curing condition for shield segment concrete with the design strength of 60 MPa. From a series of experiments, the condition of 50% replacement of ordinary cement by ground granulated blast furnace slag and unit water content of 125 kg/$m^3$ was proposed as the optimum mixing condition. Comparing with standard curing conditions, it was also possible to expect approximately 110~442% strength improvement of concrete by steam curing in the same mixing condition.

Performance of Fresh and Hardened Ultra High Performance Concrete without Heat Treatment (상온 양생한 초고성능 콘크리트(UHPC)의 경화 전과 후의 성능 관계)

  • Kang, Sung-Hoon;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.23-34
    • /
    • 2014
  • This study investigates the relationship between the performance of fresh and hardened Ultra-High Performance Concrete (UHPC) without heat treatment. The performance of fresh UHPC is determined by the slump flow test related to the fluidity of concrete mixtures, and the air content test. The variables of these tests are the water to binder ratio, superplasticizer dosages and volume fractions of steel fiber. Generally, insufficient fluidity and excessive air contents in concrete mixtures lead to the insufficient packing density related to the performance of harden concrete. The performance of hardened UHPC is determined by the compressive and flexural tensile tests. The results of the fresh UHPC tests show that there is the linear correlation between each variable and the slump flow diameter, and that the slump flow diameter is linearly decreased as the air content ratio increase. Using these results, the formula is developed to predict the fresh performance before mixing UHPC. The results of the hardened UHPC tests show that the hardened performance is not influenced by the air content ratio in the range of 3.2 to 4.2 per cent. However, the flexural tensile strength dominantly influenced by the volume fractions of steel fiber.

Structural Performance of Reinforced Concrete Beams Strengthened with Sprayed Fiber Reinforced Polymers (Sprayed FRP로 보강된 철근콘크리트 보의 보강성능에 관한 연구)

  • Lee, Kang-Seok;Son, Young-Seon;Lee, Moon-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.421-431
    • /
    • 2007
  • The main purpose of this study is to develop a sprayed FRP repair and strengthening method, which is a new technique for strengthening the existing concrete structures by mixing one of the carbon or glass chopped fibers and one of the epoxy or vinyl ester resins with high-speed compressed air in open air and randomly spraying the mixture onto the concrete surface. At present, the sprayed FRP repair and strengthening method using the epoxy resin has not been fully discussed. In order to investigate the material property of the sprayed FRP, this study carried out tensile tests of the material specimens, which were changed with the combinations of various variables including the length of chopped fiber and the mixture ratio of chopped fiber and resin. These variables were set to have the equal material strength, compared with that of one layer of the FRP sheet. As a result, the optimal length of glass and carbon chopped fibers was fumed out to be 38 mm, and the optimal mixture ratio between chopped fiber and resin was also turned out to be 1 : 2 from each variable. And also, the thickness of the sprayed FRP to have the equal strength to one layer of the FRP sheet was finally calculated. In is study, a series of experiments were carried out to evaluate the strengthening effects of flexural beams, shear beams and damaged beams strengthened with the sprayed FRP method, respectively. The results revealed that the strengthening effects of the flexural and shear specimens were reasonably similar to those of the FRP sheet, and the developed Sprayed FRP technique is able to be used as a strengthening scheme of existing RC building.