• Title/Summary/Keyword: 최대 수요 전력

Search Result 1,426, Processing Time 0.034 seconds

A 2.5 V 10b 120 MSample/s CMOS Pipelined ADC with High SFDR (높은 SFDR을 갖는 2.5 V 10b 120 MSample/s CMOS 파이프라인 A/D 변환기)

  • Park, Jong-Bum;Yoo, Sang-Min;Yang, Hee-Suk;Jee, Yong;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.4
    • /
    • pp.16-24
    • /
    • 2002
  • This work describes a 10b 120 MSample/s CMOS pipelined A/D converter(ADC) based on a merged-capacitor switching(MCS) technique for high signal processing speed and high resolution. The proposed ADC adopts a typical multi-step pipelined architecture to optimize sampling rate, resolution, and chip area, and employs a MCS technique which improves sampling rate and resolution reducing the number of unit capacitor used in the multiplying digital-to-analog converter (MDAC). The proposed ADC is designed and implemented in a 0.25 um double-poly five-metal n-well CMOS technology. The measured differential and integral nonlinearities are within ${\pm}$0.40 LSB and ${\pm}$0.48 LSB, respectively. The prototype silicon exhibits the signal-to-noise-and-distortion ratio(SNDR) of 58 dB and 53 dB at 100 MSample/s and 120 MSample/s, respectively. The ADC maintains SNDR over 54 dB and the spurious-free dynamic range(SFDR) over 68 dB for input frequencies up to the Nyquist frequency at 100 MSample/s. The active chip area is 3.6 $mm^2$(= 1.8 mm ${\times}$ 2.0 mm) and the chip consumes 208 mW at 120 MSample/s.

Influencing Factors on Outsourcing Success in the Defense Sector (국방부문의 아웃소싱 성공도에 영향을 미치는 요인에 관한 연구)

  • Yu, Dae Beom;Oh, Jay In
    • Information Systems Review
    • /
    • v.18 no.1
    • /
    • pp.79-103
    • /
    • 2016
  • The Korean Army has to construct a system that will enable it to cope immediately with the flexible military relationships in Northeast Asia by systematizing and improving the efficiency of operations. These improvements include building a smart and strong army, concentrating on cost-effective combat skills, maximizing the utilization of private resources, and establishing a military structure based on information and technology. Accordingly, this study proposes solutions to solve the problems affecting the success of outsourcing in the defense industry. Unlike outsourcing in other government ministries, outsourcing in the national defense sector may be unrealistic because this strategy is related to the renovation project of the Ministry of the National Defense. In general, the objective of outsourcing in the defense industry, similar to other businesses, is to improve efficiency and not to reduce troops and national defense budget. Several factors, such as identification and security guarantee, risk reduction, cost saving, quality improvement, the reliability of enterprise, and professional technology, are necessary to ensure outsourcing success in the national defense sector. In terms of effectiveness, the improvement in service quality significantly influences outsourcing success in the national defense sector. Eventually, the national defense forces must be strengthened to prevent the provocative actions of North Korea and other threats by improving identification, sense of national security, and quality unlike the current outsourcing of the government, as well as emulating German GEBB or PMC, which utilizes social capital.

Bio-Signal Detection Monitoring System Using ZigBee and Wireless Network (ZigBee와 무선 네트워크를 이용한 생체신호 검출 모니터링 시스템)

  • Kim, Kuk-Se;Bang, Sun-Kwang;Lee, Jeong-Gi;Ahn, Seong-Soo;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.477-481
    • /
    • 2007
  • The emergency patient who occurs from the place where it is various the control which is quick must come to accomplish in Ubiquitous environment. In the body of the patient or the old person the organism signal sensor about under attaching condition of the patient at real-time about under the monitor ring about under disposing the control which is quick against the emergency patient does to become accomplished at the case real-time when the above will get in the body of the patient or the old person. Using ZigBee (802.15.4) system base on Shor wireless communication protocol because of complement wireless of hospital. This system use ZigBee (802.15.4) system to get for electrocardiogram, blood pressure and pulse bio-sensors. This paper constructs Bio-Sensor communication monitoring system and transmission rate and the delay which it follows possibility and node occurrence rate of wireless sensor network construction hour transmission session it leads and it verifies the effectiveness.

  • PDF

Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines (고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구)

  • Jung, Joon Sig;Choi, Sung Ho;Jeon, Hyung Jin;Kim, Yoon Shin;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.5
    • /
    • pp.353-363
    • /
    • 2014
  • The purpose of this study was to investigated the ELF-MF emission level of various environments such as 258 facilities near located to high voltage transmission lines and 120 high voltage transmission lines, 17 underground cable lines. In addition, ELF-MF reduction rate according to separation distance was calculated by using simulations. An appropriate separation distance showing below 4mG was at least 70m. In the case of the appropriate separation distance for 120 high voltage transmission lines, 154kV required 20m of separation distance and 345kV required 60m of separation distance. The simulation results showed that the appropriate separation distance showing below 4mG was 40m and 60m for overhead 154kV and 345kV respectively. To adjust the worst conditions considering the aspects of environmental impact assessment study and the electric power currents that will increase in the future, the appropriate minimum separation distance for HVTL is judged to be above 70m in this study. Thus, there is a need to establish the greenbelt or buffer zone within 70m so as to create an environment in which the receptors are not exposed and thereby eliminate the risk factors of ELF-MF against humans.

KSTAR 토카막 플라즈마 가열을 위한 중성 입자빔 입사장치용 이온원 개발 현황

  • Kim, Tae-Seong;Jeong, Seung-Ho;Jang, Du-Hui;Lee, Gwang-Won;In, Sang-Yeol;O, Byeong-Hun;Jang, Dae-Sik;Jin, Jeong-Tae;Song, U-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.559-559
    • /
    • 2013
  • KSTAR (Korea Superconducting Tokamak Advanced Research) 장치는 차세대 에너지원 중의 하나인 핵융합로를 위한 과학기술 기반을 마련하기 위해 개발된 중형급 토카막 실험장치로서 토카막 운전 영역의 확장과 안정성 확보, 정상상태 운전 도달을 위한 방법 연구, 최적화된 플라즈마 상태와 연속 운전 실현 등을 주요 목표로 하고 있다. 이를 위해 핵융합 반응에 의한 점화조건과 가까운 상태로 플라즈마를 가열해주어야 하며, 토카막 장치의 저항가열 이외에도 외부에서 추가 가열이 반드시 필요하다. 중성 입자빔 입사 장치는 현재 토카막에서 사용되고 있는 가열장치 중 가장 신뢰성있는 추가 가열 장치라 할 수 있으며 한국 원자력연구원에서는 1997년부터 KSTAR 토카막 실험 장치에 사용될 중성 입자빔 입사 장치를 개발해왔었다. 중성빔 입사 장치는 크게 이온원, 진공함, 열량계, 진공 펌프, 중성화 장치, 이온덤프와 전자석으로 이루어져 있으며, 이중 이온원은 중성빔의 성능을 좌우하는 핵심적인 장치라 할 수 있다. 최근 한국원자력연구원에서는 2 MW 중성 입자빔 입사장치용 이온원 개발을 완료하여 KSTAR 토카막 장치에 설치하였으며, 2013년 현재 KSTAR에는 총 두 개의 이온원이 장착되어 최대 약 3 MW 이상의 중수소 중성 입자빔을 입사하여 KSTAR 토카막 실험의 H-mode 달성과 운전 시나리오 연구에 많은 기여를 하고 있다. 한국원자력연구원에서 최초로 개발된 이온원은 미국 TFTR 장치에서 사용되었던 US LPIS (Long Pulse Ion Source)를 기본으로 하여 국내 개발을 수행하였다. 이 온원은 크게 플라즈마를 발생시키는 플라즈마 발생부와 발생된 이온을 인출 및 가속시키는 가속부로 구성되는데, 개발과정에서 가장 먼저 KSTAR의 장주기 운전에 적합하도록 플라즈마 방전부와 가속부의 냉각회로를 요구되는 열부하에 맞게 설계 수정하였다. 그 후 플라즈마 방전부는 방전 시간과 안정성, 플라즈마 밀도의 균일도, 정격 운전, 방전 효율 등을 고려하여 수정 보완하며 개발을 진행하여왔다. 가속부의 경우 국내 제작기술의 한계를 극복하기 위해 빔 인출그리드를 TFTR의 US LPIS 모델의 슬릿형 그리드 타입에서 원형 인출구 타입으로 변경하였으며, 이후 가속 전극의 고전압 내전력 문제, 빔 인출 전류와 전력, 인출 빔의 광학적 질(quality), 빔 인출 시간 동안의 안정성 등을 위해 그리드의 크기와 간격, 모양 등을 변경하여 개발을 수 행하여 왔다. 이 논문은 한국원자력연구원에서 개발이 진행되어 왔던 이온원들을 시간적으로 되짚어 보면서 현재까지의 성과와 문제점, 그리고 앞으로의 개발 방향에 대해 논의하고자 한다.

  • PDF

A Property Analysis on Spatial Distribution of Sea Water Temperature Difference for Site Selection of Ocean Thermal Energy Conversion Plant (해양온도차 발전소의 입지선정을 위한 해수 온도차의 공간적 분포특성 분석)

  • 서영상;장이현;조명희
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.567-575
    • /
    • 1999
  • This study found potential ability to generate electric power using difference in water temperature between sea surface water and deep water in the East Sea which includes the East Sea Proper Water with the temperature less than 1$^{\circ}C$ throughout a year without seasonal variation. To quantify the difference in water temperature between sea surface water and deep water in the East Sea. We computed the annual mean ($^{\circ}C$), the annual amplitude ($^{\circ}C$), the annual phase (degree) and the duration time which showed more than 15$^{\circ}C$ temperature difference from the water temperature data using Harmonic analysis during 1961~1997. The best place for generating electric power in the East Sea seems to be the eastward ocean areas (36$^{\circ}$ 05'N, 129$^{\circ}$ 48'E~36$^{\circ}$ 05'N, 130$^{\circ}$ 00E'E) from Pohang city. The annual mean of the difference in water temperature between sea surface water and 500 m depth was 24$^{\circ}$C at the place to generate electric power in August according to the data of 1961~1997. the maximum duration periods with more than 15$^{\circ}C$ temperature difference were 215 days (5/5-12/10) a year in the place mentioned electricity with a stable plan. In the East Sea coastal areas of the Korean peninsula, the average minimum depth to reach the East Sea Proper Water from surface water is 300 m and fluctuates between 250 m and 350 m throughout a year. Further studies could be needed for the utilization of cold water, such as the East Sea Proper Water for energy conversion.

  • PDF

Low-Voltage EM(Elasto-Magnetic) Sensing Technique for Tensile Force Management of PSC(Prestressed Concrete) Internal Tendon (PSC 내부 텐던의 긴장력 관리를 위한 저전압 EM 센싱 기법)

  • Park, Jihwan;Kim, Junkyeong;Eum, Ki-Young;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.2
    • /
    • pp.87-92
    • /
    • 2019
  • In this paper, we have verified a low-voltage EM(elasto-magnetic) sensing technique for tensile force management of PSC(prestressed concrete) internal tendon in order to apply the technique to actual construction sites where stable power supply is difficult. From observation of past domestic and overseas PSC structural accident cases, it was found that PS tension is very important to maintain structural stability. In this paper, we have tried to measure the tensile force from a magnetic hysteresis curve through EM sensors according to voltage value by using relation between magnetostriction and stress of ferromagnetic material based on elastic-magnetic theory. For this purpose, EM sensor of double cylindrical coil type was fabricated and tensile force test equipment for PS tendon using hydraulic tensioning device was constructed. The experiment was conducted to confirm relationship between changes of permeability and tensile force from the measurement results of the maximum / minimum voltage amount. The change of magnetic hysteresis curve with magnitude of tensile force was also measured by reducing amount of voltage step by step. As a result, the slope of estimation equation in accordance with magnitude of magnetic field decreases with the voltage reduction. But it was confirmed a similar pattern of change of magnetic permeability for the magnetic hysteresis loop. So, in this study, it is considered that it is possible to manage the tensions of PSC internal tendon using EM sensing technique in low-voltage state.

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Properties of Perovskite Materials and Devices Fabricated Using the Solvent Engineered One-Step Spin Coating Method (단일 스텝 스핀 코팅 방법에서 증발 제어 공정 변경에 따른 페로브스카이트 박막 물성 및 태양 전지 소자 특성 변화에 관한 연구)

  • Oh, Jungseock;Kwon, Namhee;Cha, DeokJoon;Yang, JungYup
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1208-1214
    • /
    • 2018
  • The one-step spin coating method is reported as an excellent thin film process because it can be easily used to fabricate high-quality methyl-ammonium lead tri-iodide ($MAPbI_3$) perovskite layers. One of the important things in the one-step spin coating method towards obtaining high-quality $MAPbI_3$ layers is the anti-solvent (AS) engineering, which consists of an one-step deposition of the $MAPbI_3$ film and dripping of the AS. The properties of the $MAPbI_3$ layer were found to be strongly influenced by the amount, dispensing speed, and spraying time of the AS solution. The $MAPbI_3$ solution was prepared by dissolving lead iodide and methyl-ammonium iodide in N,N-dimethylformamide and adding N,N-dimethyl sulfoxide. Diethyl ether (DE) was used for the AS solution. The results indicate that a $MAPbI_3$ layer appropriately sprayed with DE is beneficial for improving film quality and device efficiency because nucleation of $MAPbI_3$ layer is affected by the characteristics of DE, which affect the film's crystallinity, density, and surface morphology. The $MAPbI_3$ layer, which was optimized by using 0.7 mL of DE, a 3.03 mL/sec dispensing speed, and a 7 second time to spray after spinning showed the best efficiency of 13.74%, which was reproducible.

Economic Effect Analysis of Pyongyang's 50,000 Housing Units Construction Project (평양 5만세대 주택건설계획의 경제적 효과 분석)

  • JooYung Lee
    • Analyses & Alternatives
    • /
    • v.8 no.1
    • /
    • pp.87-109
    • /
    • 2024
  • At the 8th Party Congress in 2021, North Korea announced a plan to build 50,000 housing units in Pyongyang, and this paper analyzes the economic effects and related informal costs of of the project. Currently, Pyongyang is experiencing a significant housing shortage. It is estimated that the number of households in Pyongyang increased by 184,000 between 1994 and 2020, while the estimated new housing supply during the period was only 30,000. Pyongyang's 50,000 housing units construction project is characterized by the goal of improving the living conditions of workers, the application of the new city construction method, and the largest state-led housing construction since the Arduous March. The project is expected to generate economic effects such as increasing workers' motivation to work, increasing tourism resources, and generating income from related industries. On the one hand, a significant portion of the construction cost of the 50,000-unit housing project in Pyongyang is passed on to companies and households in the form of informal cost such as quasi-taxes and manpower mobilization. In addition, there may be congestion in the power supply and sewerage facilities that occur when moving in. If these costs are not taken into account, the feasibility of a housing construction project may not be properly assessed, making it difficult to sustain it in the long term.