• Title/Summary/Keyword: 촬영지

Search Result 2,101, Processing Time 0.037 seconds

Microcalcification Extraction by Wavelet Transform and Automatic Thresholding (웨이브렛 변환과 자동적인 임계치 설정에 의한 미세 석회화 검출)

  • Won, Chul-Ho;Seo, Yong-Su;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.4
    • /
    • pp.482-491
    • /
    • 2005
  • In this paper, we proposed the microcalcification detection algorithm which is based on wavelet transform and automatic thresholding method in the X-ray mammographic images. Digital X-ray imaging system is essential equipment in the field diagnosis and is widely used in the various fields such as chest, fracture of a bone, and dental correction. Especially, digital X-ray mammographic imaging is known as the most important method to diagnose the breast cancer, many researches to develop the imaging system are processing in country. In this paper, we proposed a microcalcifications detection algorithm necessary in the early phase of breast cancer diagnosis and showed that a algorithm could effectively detect microcalfication and could aid diagnosis-radiologist.

  • PDF

Distortion Corrected Black and White Document Image Generation Based on Camera (카메라기반의 왜곡이 보정된 흑백 문서 영상 생성)

  • Kim, Jin-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.18-26
    • /
    • 2015
  • Geometric distortion and shadow effect due to capturing angle could be included in document copy images that are captured by a camera in stead of a scanner. In this paper, a clean black and white document image generation algorithm by distortion correction and shadow elimination based on a camera, is proposed. In order to correct geometric distortion such as straightening un-straight boundary lines occurred by camera lens radial distortion and eliminating outlying area included by camera direction, second derivative filter based document boundary detection method is developed. Black and white images have been generated by adaptive binarization method by eliminating shadow effect. Experimental results of the black and white document image generation algorithm by recovering geometrical distortion and eliminating shadow effect for the document images captured by smart phone camera, shows very good processing results.

An Improved Method for the Identification of the Space-Vriant Motion Blur using RATS (RATS를 이용한 개선된 지역적 모션 블러 크기 추출 기법)

  • Yang, Hong-Taek;Hwang, Joo-Yeon;Park, Doo-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.1
    • /
    • pp.125-133
    • /
    • 2008
  • Motion blur is a blurring effect on an image caused by the relative motion between the camera and objects in the scene. When an image is captured, motion blurs are caused by relative motion between the camera and the scene. When different objects are moving at different speeds, the characteristics of the blur effect for each object appear differently. To restore the spatially variant blurred image, each of the blur extents should be identified. In this paper, we propose a new method for the identification of blur extent locally using RATS from the image in which the spatially variant motion blur is caused Experiment shows that the proposed algorithm successfully segments the objects with different blurs and identifies the blur extents quite well.

  • PDF

Implementation of Automatic Detection System for CCFL's Defects based on Combined Lighting (조합조명 기반 CCFL 불량판별 자동화 시스템 구현)

  • Moon, Chang-Bae;Ahn, Young-Hoon;Lee, Hae-Yeoun;Kim, Byeong-Man;Oh, Duk-Whan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.69-81
    • /
    • 2010
  • A Cold Cathode Fluorescent Lamp(CCFL) is used as a LCD Monitor's backlight widely. The most common way to check CCFL's defects is an examination with the naked eye. This naked eye examination can cause an examination inconsistency and an industrial disaster. To examine CCFL defects, a shooting equipment and a defect detection algorithm are necessary. This paper shows the shooting environments for checking CCFL and presents some CCFL defect detection algorithms. As a result of experiments, our implementations showed 98.32% of successful defect detection of CCFL.

3D Stereoscopic Terrain Extraction of Road Cut Failure Slope Using Unmanned Helicopter Photography System (무인 헬리콥터 사진촬영시스템을 이용한 도로 절개지 붕괴사면 3차원 입체 지형 추출)

  • Jang, Ho-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.5
    • /
    • pp.485-491
    • /
    • 2010
  • Acquisition of information on failure slope, which may cause apprehension of second hand damage, requires acquisition of fast and accurate topographical data and efficient expression in indirect surveying method without accessing as needed. Therefore, in this study, the images on the intended area were photographed through hovering in the air by approaching collapsed road cut slope with the use of unmanned helicopter photography system. As a result of comparing the points observed by no prism total station and the 10 coordinate points analyzed through image analysis, the averages of absolute values were shown to be 0.056m in X axis direction, 0.082m in Y axis direction and 0.066m Z axis direction. In addition, the RMSE of the error for 10 points of test points were 0.015636m in X axis direction, 0.021319m in Y axis direction and 0.018734m in Z axis direction. Therefore, this method can determine the range of slope and longitudinal and cross sections of each slope in dangerous area that cannot be approached in relational image matching method for the terrains of such collapsed cut slope.

Standard of Creativity in the Copyrightable Photographic Works (사진저작물의 창작성 판단 기준)

  • Choi, Eun-Heui
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.7
    • /
    • pp.93-105
    • /
    • 2015
  • Upon ruling that two photographs of "Solsum(located in Samchuk city)" are not substantially similar, issues on the level of protection for the copyrighted photographs expecially on landscape, which appearance could be similar whoever takes, were raised. Accordingly, this study summarizes and suggests the standards of expression differentiating from idea on photographic works. The results are as such. Elements of expression on photographs are positioning of subject, framing, selection of camera angle, control of light's direction and quantity, length of exposure, speed of shutter, timing or posing of the shutter. kinds of emulsion, methods of development, and any other methods of creative and characteristic photography. On the other hand, elements of ideas of photographic works are theme, concept, feeling, appearance of objects, time or season of taking a picture, vantage point, choice of horizontal or vertical angle, etc. As a result, this study reconfirms that copyright law entitles photographers to copyright as to their minimal degree of creativity, not as to their sweat of brows.

Generation of 3-Dimensional Landscape Map from Aerial Photos (항공사진을 이용한 3차원 경관도 제작)

  • Yeu, Bock-Mo;Jeong, Soo;Kim, Won-Dae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.3 no.1 s.5
    • /
    • pp.105-113
    • /
    • 1995
  • Three-dimensional landscape map is very useful in terrain analysis as it looks like real shape of terrain. When three-dimensional landscape map is needed, landscape photos achieved at a position of high elevation or by airplane are generally used. But, this approach can not fully satisfy the user's need to get pictures from various view points. In addition, because photos have some geometric displacement caused by the principle of central projection of camera, it is hard to get accurate locations from the photo. This paper aims to get three-dimensional landscape map similar to real terrain feature from vertical stereo aerial photos by digital photogrammetric techniques. This approach can provide a very useful data for three-dimensional terrain analysis as a function of Geo-Spatial Information System.

  • PDF

Comparison of Quality Control for Chest Radiography between Special Examination and Medical Institution for Pneumoconiosis (진폐 정밀/요양기관과 요양기관의 흉부 방사선분야 정도관리 비교)

  • Lee, Won-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.322-330
    • /
    • 2011
  • To compare of quality control for chest radiography between special examination (SEP) and medical institution for pneumoconiosis (MIP). For the first time, we had visited at 33 institutions (SEP; 17 institutions, MIP; 16 institutions) to evaluate the quality control of chest radiography which is used in diagnosis of patients with pneumoconiotic complications. Image quality was rated by two experienced chest radiologists, and evaluated for radiological technique (RT), reading environment (RE) and image quality (IQ) between SEP and MIP according to the guideline published by OSHRI. Generator capacity, used duration and modality of chest radiography equipment were not signigicant difference between SEP and MIP, but there were signigicant difference in tube voltage and grid ratio used for chest radiography except to tube current and exposure time. SEP was statistically significant higher in RT (71.2 vs. 54.5, p=0.015), RE (78.8 vs. 51.5, p=0.007) to MIP, but not significant difference in IQ (64.8 vs. 59.3, p=0.180). For reliable and precisional diagnosis of patients with pneumoconiotic complications, the MIP requires the evaluation and education of quality control for improving chest radiography.

Dose Change according to Diameter Change of the Cone for Dental X-ray Apparatus (치과구내용 X선발생기의 조사통 직경 변화에 따른 선량변화)

  • Ahn, Sung-Min;Oh, Jung-Hoan;Choi, Jung-Hyun;Shin, Gwi-Soon;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.266-270
    • /
    • 2010
  • In case of the Dental X-ray apparatus, the diameter (or the field size) of the tip of the cone should be less than 7 cm according to the Diagnosis Radiation Equipment Safety Management. However, deviation from the field is not expected to be big as photography is made at close range from the skin. Also, as the size of film or digital detector used in intra-oral photography is $3\times4cm^2$, the size mentioned above can be considered to be much bigger. Furthermore, the patient dose by short-distance photography can not be ignored. Therefore, effect on the patient dose, resolution and image qualty was examined by reducing the cone diameter by 0.5 cm interval. The result showed that the patient dose was reduced and a partial improvement in picture contrast was observed. Therefore, it can be concluded from these results that further investigation may be worthwhile in terms of policy.

A Study on Projection for Apophyseal Joints Diagnosis in X-ray Thoracic Bone Oblique Projection (X-ray 등뼈의 사위 촬영에서 돌기사이관절의 진단을 위한 촬영법 연구)

  • Jun-Heang Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.351-357
    • /
    • 2023
  • This Study Rreceived Subjective Evaluation ROC Evaluation from five projection. of projection. at a University Hospital to Obtain and Diagnose Sharp images of apophyseal joints and Vertral arch of Thoracic vertebrae from thoracic X-ray projection. In the Subjective evaluation, the highest Score was obtained by raising the phantom from Supine to LAO by 70° and scoring 20 points at 5° with the X-ray Tube facing the head. In addition, he scored the highest score of 19 points at 8° with the Prone Phantom standing 60° with RAO and the X-ray Tube facing the head. For Objective Evaluation, the Signal-to-noise ratio, was calculated. ROI was set at 1,564 mm2 to obtain the image signal average value (Mean value) and the Standard deviation (SD value). Objective Evaluation The signal-to-noise ratio, was the highest at 5° toward the head in the LPO 70° position of the phantom in the lying position of the Thoracic spine projection, and the Thoracic Spine was the highest at 8° toward the head of the RAO posture of 5,645.