• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.032 seconds

The Relationship between Anterior Disc Displacement without Reduction and Development of Anterior Open Bite (비정복성 관절원판변위와 전치부 개교합 발생간의 관계)

  • Hur, Yun-Kyung;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.293-303
    • /
    • 2007
  • The purpose of this paper is to evaluate if there is a relationship between anterior disc displacement without reduction and development of anterior open bite, and a relation between occurrence of open bite and occlusal appliance therapy. In general, the statistically significant differences were found between the Group 1 and 2 and normal mean group. The variables that represent mandibular size and form, showed a statistical significance in all 3 groups. Also 3 groups patients had a smaller ANB, a larger FMA than normal mean group. When we compared the 3 groups with respect to all cephalometric measurements by One-way analysis of variance (ANOVA), group 1 and 2 patients had a larger FMA, a larger SN to mandibular plane angle, a larger maxillomandibular plane angle, a larger occlusal plane to mandibular plane angle, a smaller total posterior facial height/total anterior facial height(%), and a larger gonial angle than group 3. The statistically significant differences were not found between the Group 1 and 2, and skeletal patterns were similar. Thus, morphologic features of patients with vertical discrepancies may represent a risk factor for the development of anterior open bite with or without occlusal appliance treatment. In case of patients with vertical discrepancy, we may have to be more careful when inducing a change of the vertical dimension.

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF

Estimation of Natural frequencies in Osteoporotic Mouse Femur: A finite Element Analysis and a Vibration Test (골다공증에 걸린 쥐 대퇴골의 고유진동수 예측: 유한 요소 해석 및 진동 실험)

  • Kim, Yoon-Hyuk;Byun, Chang-Hwan;Oh, Taek-Yul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.239-246
    • /
    • 2005
  • In this study, a finite element analysis and a vibration test were performed to estimate the natural frequencies of mouse femurs with osteoporosis. Three groups of the femurs include the osteoporotic group, the treated group and the normal group. For the finite element analysis, the micro finite element model of the femur was reconstructed using the Micro-CT images and the Voxel mesh generation algorithm. In the vibration test, the natural frequencies were measured by the mobility test. from the results, the averaged natural frequencies in the osteoporotic group were the highest, followed by those in the treated group. The finite element models were validated within 15% errors by comparing the natural frequencies in the finite element analysis with those in the vibration test. The developed Micro-CT system, the Yokel mesh generation algorithm, the presented finite element analysis, and vibration test could be useful for the investigation of the structural change of the bone tissue, and the diagnosis and the treatment in the osteoporosis.

A Study on Compression Paddle Materials to Reduce Radiation Exposure Dose During Mammography; PC and PMMA and Carbon (유방촬영 시 피폭선량을 줄이기 위한 압박대 재질의 PC, PMMA, Carbon에 대한 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.81-87
    • /
    • 2015
  • This study was designed the band material in order to reduce the exposure pressure of the breast and the material was measured of Radiolucent and radiation properties with a radiation materials of PC, PMMA, Carbon. Also the image quality by image analysis to obtain the following results are below: Unfors Xi dosimetry using radiation transmittance when the results of 8.353mGy is measured after removal of the cuff, the PC 6.308mGy, PMMA 6.223mGy, Carbon 7.218mGy were measured respectively. Semi-layer PC 0.375mmAl, PMMA 0.370mmAl, with Carbon 0.360mmAl Carbon, PC, PMMA was higher radiation properties and transparency in order. InLight / OSL NanoDotTM dosimeter was used in the cuff and then removed by placing the dosimeter measured results center on 1.143mGy, at the edge 12.56mGy, on the central PC 8.990mGy, at the edge 10.291mGy, PMMA center on 8.391mGy, the edge 9.654mGy, on Carbon center 9.581mGy, 11.313 mGy were measured at the edge of Carbon, PC, PMMA showed a high permeability in order. Image Pixel average J is then removed from the cuff 976.655, PC 831.032, PMMA 819.069, Carbon 897.118 Carbon, PC, PMMA was measured by high order.

The Effect of Muscle Activity on Muscle Architectural of Medial Gastrocnemius in Chronic Stroke Patient Based on Ankle Joint Degree (만성 뇌졸중 환자에서 발목관절 각도에 따른 근 수축이 내측 비복근의 근 구조에 미치는 영향)

  • Kim, Tae-Gon;Bae, Sea-Hyun;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3991-3998
    • /
    • 2012
  • The aim of this study was to effect of muscle activity on muscle architectural of medial gastrocnemius in chronic stroke patient based on ankle joint degree. The subjects of this study were 10 chronic stroke patients modified Ashworth scale(MAS) 2. Ultrasonographic and dynamometer was measured during resting and maximum voluntary isometric contraction(MVIC) on muscle thickness, pennation angle, fascicle length, MVIC. Result from analysis showed that muscle thickness was thinner in the paretic side than in the non-paretic side(p<.001) and the more plantarflexion increased, the thinner muscle thickness became. And at the time of resting rather than of MVIC significant(p<.001). Result from analysis showed that penneation angle was smaller in the paretic side than in the non-paretic side(p<.001) and the more plantarflexion increased, the larger pennation became. And at the time of resting rather than of MVIC significant(p<.001). Result from analysis showed that fascicle was shorter in the paretic side than in the non-paretic side(p<.001) and the more plantarflexion increased, the shorter fascicle length became. And at the time of resting rather than of MVIC significant(p<.001). The results of this study showed that effect of muscle activity on muscle architectural of medial gastrocnemius in chronic stroke patient based on ankle joint degree. Therefore, Ultrasonographic evaluation of chronic stroke patients according ankle joint degree and muscle activity in the clinical diagnosis and therapy is considered a very useful data.

A Study on Muscle Architectural and Tissue Compliance of Biceps Brachii in Stroke Patient Based on Elbow Joint Angle (뇌졸중 환자에서 주관절 각도 변화에 따른 상완이두근의 근구조 및 탄성 변화에 관한 연구)

  • Bae, Sea-Hyun;Jeong, Chan-Joo;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5867-5874
    • /
    • 2012
  • The aim of this study was to find on muscle architectural and tissue compliance of biceps brachii in stroke patient based on elbow joint angle. The subjects of this study were twelve hemiplegic adults after stroke with passive range of motion in the elbow from $10^{\circ}$ to $90^{\circ}$ and Modified Ashworth Scale score 1 to 3 were recruited. Ultrasonography and Myotonometer was used to measure biceps brachii muscle pennation angle, fascicle length, and tissue compliance at the rest condition and pennation angle, fascicle length, and tissue compliance of the biceps brachii muscle were measured in the affected and unaffected sides of people after stroke at 9 different elbow angles ranging from $10^{\circ}$ to $90^{\circ}$ at the rest condition. The results of this study, comparisons found that the pennation angles of the affected biceps brachii muscle were significantly larger(p<.05) than the unaffected muscle in the most extended positions($<40^{\circ}$), whereas the affected fascicle lengths were significantly shorter(p<.05) than the unaffected muscle in most flexed positions($>20^{\circ}$), and the affected tissue compliance were significantly lower(p<.05) than the unaffected muscle in most extended positions($<50^{\circ}$) Therefore, pennation angles, fascicle lengths, and tissue compliance were found to be joint-angle-dependent in both the affected and unaffected sides at the rest condition. Suggest that, the results data can be used as a muscle architectural changes and clinical treatment research in stroke patients.

Experimental study for the irradiation effect of x-ray on the hatching process of fertilized eggs (X선 조사가 닭 유정란 부화과정에 미치는 영향)

  • Jeon, Byeong-Kyou;Yeo, Jin-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6413-6419
    • /
    • 2013
  • This study examined the irradiation effect of high energy x-rays on the hatching process of fertilized eggs, particularly with regard to malformation and blood cells change. The experimental groups were five day old fertilized eggs irradiated with x rays at doses of 5, 7.5, 10 Gyusing alinear accelerator. The control group was not irradiated. After three weeks, hatched chicks were sacrificed and examined for blood sampling. The survival rate of the x-ray irradiated groups were significantly lower than that of the control group (46.7vs 80%). The malformation rate of the experimental groups was60%, whereas no congenital malformations were observed in the control group. The experimental groups had a significantly higher malformation rate. The types of malformation were left wing defect, proptosis, microcephaly, cervical spine, and feet anomaly. The incidence of malformation increased with increasing radiation dose. The white blood cell count of control group and eachexperimental groups (5 and 7.5 Gy) were 87.64, 100.76 and 81.42 ($10^3/{\mu}L$), respectively. X-ray irradiation of 5 day old chick embryos increased the rate of death and malformation significantly.The malformations were estimated to have occurred by chromosomal abnormalities. Further genetic studies will be needed to confirm the correlation between high energy X-rays and the cause of malformations.

Measurement from Moving Vehicle Health Screening Outside of The Leakage Dose (이동건강검진차량에서 외부의 누설선량 측정)

  • Han, Beom-Hee;Han, Sang-Hyun;Mo, Eun-Hee;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.192-198
    • /
    • 2015
  • Checked out by the moving vehicle health checks for patients, practitioners, and the increase in radiation dose outside the vehicle, but an investigation into the leakage of radiation can still be negligible. In this study, through experimental results were as follows: Dose that occurs most often where the leak in the right door $1.14{\pm}1.75mR/h$, X-ray generator in terms of proximity to the top $0.65{\pm}1.25mR/h$, X-ray generator and away to the bottom in terms $0.91{\pm}1.25mR/h$, the adjacent rear detector in the upper part $96.98{\pm}158.88mR/h$ dose of the leak appeared in various locations. By measuring position from the rear of the adjacent detector $67.48{\pm}97.03mR/h$ dose had the highest leakage into. Generating device for diagnosis of radiation safety regulations regarding the maximum leakage dose per week, but all met back when it is displayed in the leakage dose Hourly rates do not ignore the leakage radiation dose were measured. Therefore, a mobile health screening in a vehicle outside of the leakage radiation dose to the liver and move on we are not interested twelve barrier leakage radiation dose of defense has a chance to re-evaluate the standards required, and move the vehicle health check using the X-ray increases as the dose per hour, depending on the criteria for choosing the appropriate measures that will require effort.

A Study of Heterogeneity Corrections for Radiation Treatment Planning (방사선 치료계획 시 불균질 보정에 관한 고찰)

  • Lee, Je-Hee;Kim, Bo-Gyum;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.89-96
    • /
    • 2006
  • Purpose: To study effectiveness of heterogeneity correction of internal-body inhomogeneities and patient positioning immobilizers in dose calculation, using images obtained from CT-Simulator. Materials and Methods: A water phantom($250{\times}250{\times}250mm^3$) was fabricated and, to simulate various inhomogeneity, 1) bone 2) metal 3) contrast media 4) immobilization devices(Head holder/pillow/Vac-lok) were inserted in it. And then, CT scans were peformed. The CT-images were input to Radiation Treatment Planning System(RTPS) and the MUs, to give 100 cGy at 10 cm depth with isocentric standard setup(Field Size=$10{\times}10cm^2$, SAD=100 cm), were calculated for various energies(4, 6, 10 MV X-ray). The calculated MUs based on various CT-images of inhomogeneities were compared and analyzed. Results: Heterogeneity correction factors were compared for different materials. The correction factors were $2.7{\sim}5.3%$ for bone, $2.7{\sim}3.8%$ for metal materials, $0.9{\sim}2.3%$ for contrast media, $0.9{\sim}2.3%$ for Head-holder, $3.5{\sim}6.9%$ for Head holder+pillow, and $0.9{\sim}1.5%$ for Vac-lok. Conclusion: It is revealed that the heterogeneity correction factor calculated from internal-body inhomogeneities have various values and have no consistency. and with increasing number of beam ports, the differences can be reduced to under 1%, so, it can be disregarded. On the other hand, heterogeneity correction from immobilizers must be regarded enough to minimize inaccuracy of dose calculation.

  • PDF