• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.03 seconds

Reduction of Entrance Surface Dose Depending on Shielding Methods for Panoramagraphy (파노라마 X선 검사시 차폐방법에 따른 Entrance Surface Dose 저감)

  • Choi, Jung-Hyun;Kim, Sung-Chul;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.199-203
    • /
    • 2015
  • Panoramagraphy was the second most used intraoral radiography utilized in Korea, resulting in 17.8% in university dental hospitals, 24.8% in dental hospitals, and 31.4% in dental clinics. Depending on increased demand like orthodontics and implant, panoromagraphy tends to consistently increase. This study were used lead glasses and lead shielding to reduce unnecessary radiation to the eyeballs and thyroid. ESD was 41.4% when radiation was shielded with the lead glasses while reducing 47.3% of ESD by shielding the X-ray tube area with shielding lead. There was no statistically significant difference. The lead glasses is appropriated to reduce unnecessary radiation exposure to the eyeballs.

BLDC Motor Control Unit for Automation of X ray Equipment (X선 기기의 자동화를 위한 BLDC 모터 제어 장치)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.833-838
    • /
    • 2011
  • X-ray device used in the diagnosis has made possible to have more effective and accurate diagnosis, powered by the development of various devices. Based on this, X-ray device has become the most basic and essential diagnostic equipment in clinical medicine. At present, in the image acquisition field using X-ray, the use of Digital radiography which is useful in the acquisition time reduction and transfer of images and is possible to have the dose reduction has expanded. With the structure using one detector, this DR device has disadvantages in that it needs structural changes unlike existing X-ray and the detector should be moved to the desired position depending on the shooting location. Therefore, in this study, using BLDC(Brushless direct current) motor and PID(Proportional integral differential) control method, the automatic control system of 3-axis which is upward and downward, left and right and rotation of detector where having the most movement in DR was designed and produced and its performance was evaluated.

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

Three dimensional analysis of tooth movement using different types of maxillary molar distalization appliances (간접골성 고정원을 이용한 상악 구치부 원심이동 장치 종류에 따른 치아 이동 양상 평가)

  • Kim, Su-Jin;Chun, Youn-Sic;Jung, Sang-Hyuk;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.376-387
    • /
    • 2008
  • Objective: The purpose of this study was to compare the three dimensional changes of tooth movement using four different types of maxillary molar distalization appliances; pendulum appliance (PD), mini-implant supported pendulum appliance (MPD), stainless steel open coil spring (SP) and mini-implant supported stainless steel open coil spring (MSP). Methods: These experiments were performed using the Calorific $machine^{(R)}$ which can simulate dynamic tooth movement. Computed tomography (CT) images of the experimental model were taken before and after tooth movement in 1 mm thicknesses and reconstructed into a three dimensional model using V-works $4.0^{TM}$. These reconstructed images were superimposed using Rapidform $2004^{TM}$ and the direction and amount of tooth movement were measured. Results: The mean reciprocal anchor loss ratio at the first premolar was 17 - 19% for the PD and SP groups. The appliances using mini-implants (MPD or MSP) resulted in less anchorage loss (7 - 8%). On application of a pendulum appliance or MPD, distalization was obtained by tipping rather than by bodily movement. Furthermore, the maxillary second molar tipped distally and bucally. But on application of MSP, distalization was achieved almost by bodily movement. Conclusions: Regarding tooth movement patterns during molar distalization, stainless steel open coil spring with indirect skeletal anchorage was relatively superior to other methods.

Implementation of the Color Matching Between Mobile Camera and Mobile LCD Based on RGB LUT (모바일 폰의 카메라와 LCD 모듈간의 RGB 참조표에 기반한 색 정합의 구현)

  • Son Chang-Hwan;Park Kee-Hyon;Lee Cheol-Hee;Ha Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.3 s.309
    • /
    • pp.25-33
    • /
    • 2006
  • This paper proposed device-independent color matching algorithm based on the 3D RGB lookup table (LUT) between mobile camera and mobile LCD (Liquid Crystal Display) to improve the color-fidelity. Proposed algorithm is composed of thee steps, which is device characterization, gamut mapping, 3D RGB-LUT design. First, the characterization of mobile LCD is executed using the sigmoidal function, different from conventional method such as GOG (Gain Offset Gamma) and S-curve modeling, based on the observation of electro-optical transfer function of mobile LCD. Next, mobile camera characterization is conducted by fitting the digital value of GretagColor chart captured under the daylight environment (D65) and tristimulus values (CIELAB) using the polynomial regression. However, the CIELAB values estimated by polynomial regression exceed the maximum boundary of the CIELAB color space. Therefore, these values are corrected by linear compression of the lightness and chroma. Finally, gamut mapping is used to overcome the gamut difference between mobile camera and moible LCD. To implement the real-time processing, 3D RGB-LUT is designed based on the 3D RGB-LUT and its performance is evaluated and compared with conventional method.

Changes of the Pharyngeal Space by Various Oral Appliances for Snoring (수종의 코골이장치 장착에 따른 인두공간의 변화)

  • Jo, Chul-Bae;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.247-256
    • /
    • 2009
  • The purpose of this study was to investigate the changes of the pharyngeal space when the following appliances were inserted: the mandibular advancement appliance (MAA), tongue retaining appliance (TRA), and mandibular advancement-tongue retaining appliance (MATRA). Nine male dental students exhibiting Class I occlusion, normal body mass index (BMI), and no signs and symptoms of snoring were selected for this study. The three kinds of snoring appliances (MAA, TRA and MATRA) were fabricated for each subject. The mandibular advancement of the MAA and MATRA was set at a distance of 5 mm, and the TRA and MATRA were made to hold the tongue in front of the maxillary incisors by 10 to 20 mm. Lateral cephalometric radiographs of the following four states - with no appliance, MAA, TRA, and MATRA - were taken to examine any anatomical changes resulting from the application of the appliances. All four radiographs were traced and analyzed for twenty selected variables related to the pharyngeal space, cranio-cervical posture, and position of the soft palate and hyoid bone. According to the results of this study, there were significant increases in both the upper and lower oropharyngeal spaces when the mandible and tongue were protruded simultaneously, although there was a significant increase only in upper oropharyngeal space when the mandible or tongue was advanced separately. In conclusion, it is suggested that the MATRA may result in more positive effect on the control of snoring and OSA compared to a single use of the MAA or TRA, especially for the patients whose upper airway obstruction occurs in the lower oropharynx.

The Use of an Iliac Branch Device: Single-Center Study of Endovascular Preservation of Internal Iliac Artery Flow (장골 분지 장치 사용: 내장골동맥 흐름의 혈관내 보존에 대한 단일 기관의 경험)

  • Hyeseung Lee;Jeong-min Lee;Soongu Cho;JungUi Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1339-1349
    • /
    • 2023
  • Purpose To determine the efficacy and safety of iliac branch device (IBD) implantation and to evaluate its limitations based on 7 years of experience in a single center. Materials and Methods This single-center study included patients with bilateral common iliac artery aneurysms (CIAAs). We investigated follow-up CT and reviewed the internal iliac artery (IIA) patency and complications related to IBD. A retrospective analysis was performed and the overall survival rate and freedom from reintervention rate were reported according to the Kaplan-Meier method. Results Of the 38 patients with CIAAs, only 10 (12 CIAAs) were suitable for IBD treatment. Five patients underwent unilateral IBD insertion with contralateral IIA embolization, and three (60%) showed claudication; however, symptoms resolved within 6 months. The 7-year freedom from IBD-related reintervention rate was 77.8%. No procedure-related deaths occurred. Conclusion IBD has good technical success and long-term patency rates; however, anatomical factors frequently limit its application, particularly in Asians. Additionally, unilateral IIA embolization showed relatively mild complications and a good prognosis; therefore, it can be performed safely for anatomically complex aortoiliac aneurysms.

Study on Improvement in Operation and Management of Ultra-light flying device Civil Complaints Management System for Ultralight Aircraft (초경량비행장치의 민원처리시스템 운용 및 관리 효율성 개선을 위한 연구)

  • Seok, Geum-chan;Jang, Moon-su;Ryu, Yeon-seung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.237-246
    • /
    • 2020
  • The background of the research is the following: As a result of ultra-light flying device industry development, the utilization of drones and their efficiency have been increasing. However, problems regarding flight permission·approval procedure have not been improved, resulting in increased number of civil complaints. Thus, the purpose of this research is to minimize such civil petition according to the required standards of the two government organizations through enhancing the procedure for managing and employing the system. The research methods entail pinpointing the problems by analysing ultra-light flying device related literature review and by holding focus-interviews with field experts, thereby verifying and providing improved solutions. Under (MLIT) Ministry of Land, Infrastructure and Transport supervision and in accordance with aviation security law, the research provides various updated functions such as improved civil petition processing system's employment and management system, flight approval, integration of names, process, format regarding aviation photographing approval, tool buttons such as the 'Main' button in the system's homepage. This research has the following expected effects : Firstly in the law and regulations section, the clear distinction in the missions and roles of each organization enhances cooperations in tackling civil petition. Secondly the integration of civil petition process reduces time and improves efficiency. And lastly, the improvement of supplementary tools for the public is expected to minimize civil petitions. Future research needs to be conducted under the supervision of the Ministry of National Defense(MND). Factors such as systematic infrastructure for flight photography approval, related unit's reorganization following the defense reform 2.0, and guaranteed conditions for field security action units need to be ameliorated.

A Study of Transient Radiation Effects on Semiconductor Devices (전자소자의 과도방사선 영향 연구)

  • Lee, Nam-Ho;Oh, Seung-Chan;Whang, Young-Gwan;Kang, Heung-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.660-663
    • /
    • 2011
  • 우주방사선이나 과도펄스(Transient Radiation) 형태의 감마 방사선이 반도체에 조사되면 소자 내부에서 짧은 시간에 다량의 전하가 생성된다. 이 전하들과 증폭된 과전류는 소자의 고장(Upset, Latchup)과 오동작을 유발시키게 되고 나아가 전자부품이 소진(Burnout)되는 직접적인 원인이 된다. 본 연구에서는 이러한 핵폭 방출 과도방사선에 대한 전자부품/장비의 내방사선관련 기초연구로 군전자부품의 감마-과도방사선에 대한 피해분석 시험을 수행하고 나아가 과도방사선 방호기술 체계구축의 필요성에 대해 논하였다. 과도펄스 방사선시험은 군용으로 분류된 반도체 칩을 대상으로 포항 전자빔가속기를 사용하였다. 핵폭발 방출 과도방사선을 모사하기 위해 감마선 변환장치를 MCNP 설계를 통해 제작하고 단일모드의 마이크로초 단위 감마펄스 방사선을 방출시켜 시험대상 칩을 부착한 시험보드에 조사하는 과정으로 실험을 진행하였다. 온라인 고속 측정장치를 통한 전자소자의 과도방사선시험에서 다양한 피해현상을 측정할 수 있었고, 열상카메라 촬영을 통하여 과열상태를 관측함으로써 피해현상의 검증과 더불어 소진현상으로의 전개 가능성을 확인하였다.

  • PDF

An Application of Dynamic Radioscopy Technique to Static Firing Test (동적 방사선투과검사를 이용한 지상연소시험 기술개발)

  • Lim, Soo-Yong;Kim, Jun-Yeop;Kim, In-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.3
    • /
    • pp.32-40
    • /
    • 2006
  • Dynamic Radioscopy technique was developed to observe internal phenomena of motors during firings. For use of this technique, generator and image box consisting of conversion screen, mirror, and video camera were designed and fabricated at our laboratory, and static firing tests were conducted to small motors. Protection devices against vibration and noise induced from during combustion were also made and their performances were evaluated with reference to the vibration criteria. Test results have shown that the vibration levels at concerned points were measured less than vibration criteria, and the internal phenomena during firings were also observed clearly.