• Title/Summary/Keyword: 총먼지

Search Result 135, Processing Time 0.026 seconds

A Study on the Wind Ventilation Forest Planning Techniques for Improving the Urban Environment - A Case Study of Daejeon Metropolitan City - (도시환경 개선을 위한 바람길숲 조성 계획기법 개발 연구 - 대전광역시를 사례로 -)

  • Han, Bong-Ho;Park, Seok-Cheol;Park, Soo-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.28-41
    • /
    • 2023
  • The objective of the study was to develop an Urban Windway Forest Creation Planning Technique for the Improvement of the Urban Environment using the case of Daejeon Metropolitan City. Through a spatial analysis of fine dust and heat waves, a basin zone, in which the concentration was relatively serious, was derived, and an area with the potential of cold air flow was selected as the target area for the windway forest development by analyzing the climate and winds in the relevant zone. Extreme fine dust areas included the areas of the Daejeon Industrial Complex Regeneration Business District in Daedeok-gu and Daedeok Techno Valley in Yuseong-gu. Heat wave areas included the areas of Daedeok industrial Complex in Moksang-dong, the Daejeon Industrial Complex Regeneration Business District in Daehwa-dong, and the high-density residential area in Ojeong-dong. As a result of measuring the wind speeds in Daejeon with an Automatic Weather System, the average wind speeds during the day and night were 0.1 to 1.7 m/s,, respectively. So, a plan of for a windway forest that smoothly induces the movement of cold air formed in outer forests at night is required. The fine dust/heat wave intensive management zones of Daejeon Metropolitan City were Daejeoncheon, Yudeungcheon, Gapcheon-Yudeungcheon, and Gapcheon. The windway forest formation plan case involved the old city center of Daejeon Metropolitan City among the four zones, the Gapcheon-Yudeungcheon area, in which the windway formation effect was presumed to be high. The Gapcheon-Yudeungcheon area is a downtown area that benefits from the cold and fresh air generated on Mt. Gyejok and Mt. Wuseong, which are outer forests. Accordingly, the windway forest was planned to spread the cold air to the city center by connecting the cold air generated in the Seosa-myeon forest of Mt. Gyejok and the Namsa-myeon forest of Mt. Wuseong through Gapcheon, Yudeungcheon, and street forests. After selecting the target area for the wind ventilation forest, a climate map and wind formation function evaluation map were prepared for the area, the status of variation wind profiles (night), the status of fine dust generation, and the surface temperature distribution status were grasped in detail. The wind ventilation forest planning concept and detailed target sites by type were identified through this. In addition, a detailed action plan was established according to the direction of creation and setting of the direction of creation for each type of wind ventilation forest.

A Study on Statistical Parameters for the Evaluation of Regional Air Quality Modeling Results - Focused on Fine Dust Modeling - (지역규모 대기질 모델 결과 평가를 위한 통계 검증지표 활용 - 미세먼지 모델링을 중심으로 -)

  • Kim, Cheol-Hee;Lee, Sang-Hyun;Jang, Min;Chun, Sungnam;Kang, Suji;Ko, Kwang-Kun;Lee, Jong-Jae;Lee, Hyo-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.4
    • /
    • pp.272-285
    • /
    • 2020
  • We investigated statistical evaluation parameters for 3D meteorological and air quality models and selected several quantitative indicator references, and summarized the reference values of the statistical parameters for domestic air quality modeling researcher. The finally selected 9 statistical parameters are MB (Mean Bias), ME (Mean Error), MNB (Mean Normalized Bias Error), MNE (Mean Absolute Gross Error), RMSE (Root Mean Square Error), IOA (Index of Agreement), R (Correlation Coefficient), FE (Fractional Error), FB (Fractional Bias), and the associated reference values are summarized. The results showed that MB and ME have been widely used in evaluating the meteorological model output, and NMB and NME are most frequently used for air quality model results. In addition, discussed are the presentation diagrams such as Soccer Plot, Taylor diagram, and Q-Q (Quantile-Quantile) diagram. The current results from our study is expected to be effectively used as the statistical evaluation parameters suitable for situation in Korea considering various characteristics such as including the mountainous surface areas.

Presence of Bacteria and Fungi in Inner Compartment of Personal Computers(PCs) (개인용 컴퓨터 내부에서 발견되는 세균과 곰팡이)

  • Kwon, Kil-Koang;Yoon, Seok-Min;Choi, Chang-Ho;Jeong, Bong-Geun;Lee, Ki-Won;Yi, Dong-Heui;Kim, Hyung-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.728-733
    • /
    • 2007
  • Presence and distribution of bacteria and fungi in inner compartment of PCs(Personal Computers) were investigated. Samples for the analysis were collected from inside of PCs which had been used in various facilities including public computer facilities, laboratories and computer training rooms of a university. Total number of PC examined in this study was 51 each. When the total CFU(colony forming unit) of the inner compartment of the PCs was measured, the bacterial count was found to be dependent on the operation time(total running time) of PCs. When the distribution of bacteria in the inner compartment of PCs was estimated, CPU(Central Processing Unit) cooling fan area showed the highest bacterial concentration(average 605 $CFU/cm^2$). In the case of the fungi, various opportunistic pathogens including Aspergillus sp. and Penicillium sp. were isolated and identified in the inner compartment of PCs. And the average of bacterial number in the dust collected from the PCs was 212 CFU/mg. These results indicated that handling of PC might have a risk of infection by the microorganism.

Distribution and Diversity of Beetles(Coleoptera: Carabidae) in Naejangsan National Park, Korea (내장산국립공원 딱정벌레류의 종 분포 및 다양성)

  • Lee, Chong-Kyu
    • Journal of agriculture & life science
    • /
    • v.45 no.4
    • /
    • pp.37-45
    • /
    • 2011
  • The study was carried out to investigate distribution and diversity of beetles with pitfall traps and beatings 3 times at Baegyang temple area of Naejangsan National park from July to September in 2010. A total of 333individuals belonging to 32 species from 13 families were captured beetles at Baegyang temple area of Naejangsan National park. The rate of captured individuals was 17.4% and 13.3% in Synuchus cycloderus and Synuchus nitidus, respectively. The total of two species was 30.7%. The number of individuals by altitude was the highest at 200m, and was order of 500m>400m>700m. A total of 333 individuals belong to 32 species from 13 families were captured at Baegyang temple area of Naejangsan National park. The number of captured individuals by monthly was 95 on July, 178 on August and 60 on September, respectively. Dominance index was the highest to Attelabidae and was the lowest to Rutelidae. Dominance index by monthly was the highest on July and was the lowest on September. Diversity index showed the highest to Rutelidae in family and on August in monthly. Menhinich index was 1.75 which species abundance indicated by beetles at Baegyang temple area of Naejangsan National park.

Environmental Analysis of Waste Cable Recycling Process using a Life Cycle Assessment Method (전과정평가기법을 활용한 폐전선 재자원화 공정의 환경성 평가)

  • Jang, Mi-Sun;Seo, Hyo-Su;Park, Hee-Won;Hwang, Yong-Woo;Kang, Hong-Yoon
    • Resources Recycling
    • /
    • v.31 no.1
    • /
    • pp.37-45
    • /
    • 2022
  • The development of the electrical, electronic, and telecommunication industries has increased the share of electricity in total energy consumption. With the enforcement of the Act on the Promotion of the Development, Use, and Diffusion of New and Renewable Energy in 2021, the mandatory supply ratio of new and renewable energy is expected to expand, and the amount of waste cables generated in the stage of replacing and discarding cables used in the industry is also expected to increase. The purpose of this study was to quantify the environmental burden of waste cable recycling through the life cycle assessment (LCA) method. The results showed that the higher the amount of glue contained in the waste cable, the greater was the amount of fine dust and greenhouse gases generated. In addition, by assigning weights to 10 environmental burden items, it was confirmed that the marine aquatic eco-toxicity potential (MAETP) and human toxicity potential (HTP) had the greatest environmental burden. The main causes were identified as heptane and ethanol, which were the glue contained in the waste cable and the cleaning solutions used to remove them. Therefore, it is necessary to refrain from using glue in the cable production process and reduce the environmental burden by reducing the use of waste cable cleaning solutions used in the recycling process or using alternative materials.

Evaluation of Indoor Air Quality in a Department of Radiation Oncology Located Underground (지하에 위치한 방사선종양학과에서의 실내공기 질 평가)

  • Kim, Won-Taek;Shin, Yong-Chul;Kang, Dong-Mug;Ki, Yong-Kan;Kim, Dong-Won;Kwon, Byung-Hyun
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.243-252
    • /
    • 2005
  • Purpose: Indoor air quality (IAQ) in the radiation treatment center which is generally located underground is important to the health of hospital workers and patients treated over a long period of time. this study was conducted to measure and analyze the factors related to IAQ and subjective symptoms of sick building syndrome, and to establish the causes influencing IAQ and find a solution to the problems. Methods and Materials : Self administrated questionnaire was conducted to check the workers' symptoms and understanding of the work environment. Based on a preliminary investigation, the factors related to IAQ such as temperature, humidity, fine particulate. carbon dioxide, carbon monoxide, formaldehyde, total volatile organic compounds (TVOC), and radon gas were selected and measured for a certain period of time in specific sites where hospital workers stay long in a day. And we also evaluated the surrounding environment and the efficiency of the ventilating system simultaneously, and measured the same factors at the first floor (outdoor) to compare with outdoor all quality, All collected data were assessed by the recommended standard for IAQ of the domestic and international environmental organizations. Results: Hospital workers were discontented with foul odors, humidity and particulate. They complained symptoms related to musculo-skeletal system, neurologic system, and mucosal-irritatation. Most of the factors were not greater than the recommended standard, but the level of TVOC was third or fourth times as much as the measuring level of some offices in the United States. The frequency and the amount of the ventilating system were adequate, however, the problem arising in the position of outdoor-air inlets and indoor-air outlets involved a risk of the indraft of contaminated air. A careful attention was a requirement in handling and keeping chemical substances including a developing solution which has a risk of TVOC emissions, and repositioning the ventilating system was needed to solve the contaminated-air circulation immediately Conclusion We verified that some IAQ-related factors and inadequate ventilating system could cause subjective symptoms in hospital workers. The evaluation of IAQ was surely needed to improve the underground working environments for hospital workers and patients. On the basis of these data, from now on, we should actively engage in designs of the department of radiation oncology or improvement in environments of the existing facilities.

Trace element Analysis and Source Assessment of Apartment Parking Lot Dust in Daegu, Korea (공동주택 주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Bae, Gun-Ho;Jung, Cheol-Su;Park, Kyu-Tae;Lee, Myoung-Sook;Shin, Dong-Chan;Kim, Yong-Hye;Yoon, Min-Hye;Han, Young-Jin;Choi, Hyuek;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.756-766
    • /
    • 2011
  • In order to investigate the degree of apartment parking lot dust contamination, total 72 samples of parking lot dust (36 from ground parking lots and 36 from the underground parking lots) were collected in Daegu city from the end of March to the early June 2010. The dust samples were sieved below $100{\mu}m$, and analysed by ICP for 14 elements after an acid extraction. Results obtained from the source assessment of trace element using enrichment factor showed that Fe, K, Mg, Mn, Na and V were influenced by natural sources, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources in both the ground parking lot and the underground parking lot. And results showed that Ca were influenced by natural sources in the ground parking lot, but influenced by anthropogenic sources in the underground parking lot. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Underground parking lot dust was more affected by anthropogenic sources and contaminated compared with the ground parking lot dust. Pollution index of heavy metals revealed that underground parking lot dust was 5.5 times more contaminated with heavy metal components than the ground parking lot dust. The results of correlation analysis among trace elements indicated that components in the ground parking lot were more correlated than those in the underground parking lot, and especially more correlated with natural sources-natural sources. Analysis for correlations between components and influencing factors in the underground parking lot showed that concentrations of heavy metals were higher with smaller number of parking spaces and no ventilation system, and older apartments in last paint and cleaning had relatively higher contents of heavy metals than those of recently painted and cleaned.

Effects of Ambient Particulate Matter($PM_{10}$) on Peak Expiratory Flow and Respiratory Symptoms in Subjects with Bronchial Asthma During Yellow Sand Period (황사기간 중 천식 환자에서 대기 중 미세먼지($PM_{10}$)가 최대호기 유속과 호흡기 증상에 미치는 영향)

  • Park, Jeong Woong;Lim, Young Hee;Kyung, Ssun Young;An, Chang Hyeok;Lee, Sang Pyo;Jeong, Seong Hwan;Ju, Young-Su
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.570-578
    • /
    • 2003
  • Background : Ambient particles during Asian dust events are usually sized less than $10{\mu}m$, known to be associated with the adverse effects on the general populations. But, there has been no considerable evidence linking these particles to the adverse effects on airways. The objectives of this study was to investigate the possible adverse effects of Asian dust events on respiratory function and symptoms in subjects with bronchial asthma. Patients and Methods : From march to June 2002, Asthmatic patients who were diagnosed with bronchial challenge test or bronchodilator response were enrolled. We divided them into three groups; mild, moderate, and severe, according to the severity. Subjects with other organ insufficiency such as heart, kidney, liver, and malignancy were excluded. All patients completed twice daily diaries and recorded peak flow rate, respiratory symptom, and daily activity. Daily and hourly mean pollutant levels of particulate matter < $10{\mu}m$ in diameter($PM_{10}$), nitrogen dioxide($NO_2$), sulphur dioxide($SO_2$), ozone($O_3$) and carbon monoxide(CO) were measured at the 10 different monitoring sites. Results : Dust events occured 14 times during the study period. Daily averages of 4 air pollutant were measured with an increased level of $PM_{10}$, decreased level of $NO_2$ and $SO_2$, and no change in CO during dust days compared to those during control days. An increase in $PM_{10}$ concentration was associated with an increase of subjects with PEF variability of >20% (p<0.05), night time symptom(p<0.05), and a decrease in mean PEF (p<0.05), which were calculated by the longitudinal data analysis. Otherwise, there was no association between $PM_{10}$ level and bronchodialtor inhaler, and daytime respiratory symptoms. Conclusion : This study shows evidence that ambient air pollution, especially $PM_{10}$, during Asian dust events, could be one of the many aggravating factors at least in patients with airway diseases. This data can be used as a primary source to set up a new policy on air environmental control and to evaluate the safety of air pollution index. We also expect that this research will help identify precise components of dust, which are more linked to the adverse effects.

Uncertainty Analysis on Vertical Wind Profile Measurement of LIDAR for Wind Resource Assessment (풍력자원평가를 위한 라이다 관측 시 풍속연직분포 불확도 분석)

  • Kim, Hyun-Goo;Choi, Ji-Hwee;Jang, Moon-Seok;Jeon, Wan-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.185.1-185.1
    • /
    • 2010
  • 원격탐사(remote sensing)란 관측 대상과의 접촉 없이 멀리서 정보를 얻어내는 기술을 말한다. 기상관측분야에는 이미 소다(SODAR) 장비가 폭넓게 사용되거 왔으나 최근 풍력자원평가(wind resource assessment)를 위한 풍황측정에 SODAR와 더불어 라이다(LIDAR)가 적극적으로 활용되기 시작하고 있다. 참고로 SODAR(SOnic Detection And Ranging)는 수직 및 동서 남북 방향으로 음파를 발생시키고 대기유동에 의해 산란 반사된 에코를 수신하여 진동수 변화와 반사에코 강도를 측정하여 각 방향의 에코자료를 벡터 합성함으로써 풍향 및 풍속을 산출하는 원리이다. 반면 LIDAR(Light Detection And Ranging)는 비교적 최근에 풍황측정 용도로 개발된 레이저 탐지에 바탕을 둔 원거리 센서로, 공기입자(먼지, 수증기, 구름, 안개, 오염물질 등)에 의해 산란된 레이저 발산의 도플러 쉬프트(Doppler shift)를 이용하여 풍향 및 풍속을 측정하는 원격탐사 장비이다. 풍력자원평가 측면에서 라이다는 그 정확도가 IEC61400-12에 의거한 풍황탑(met-mast) 측정자료 다수와의 비교검증 실측평가(Albers et al., 2009)를 통하여 입증된 바 있다. 한편 한국에너지기술연구원에서 운용 중인 라이다 시스템은 그림 1의 우측 그림과 같이 1초에 $360^{\circ}$를 스캔하여 50지점에서 반사되는 레이저를 스펙트럼으로 측정하되 설정된 관측높이에서 풍속은 샘플링 부피(sampling volume)의 평균값으로 정의된다. 그런데 샘플링 부피는 설정된 관측높이로부터 상하 12.5m, 총 25m의 높이구간에서 관측한 스펙트럼의 평균값을 그 중앙지점에서의 풍속으로 환산하는 알고리듬(algorithm)을 채택하고 있다. 따라서 비선형적으로 변화하는 풍속연직분포 관측 시 풍속환산 알고리듬에 의한 측정오차가 개입될 가능성이 존재하는 것이다. 이에 본 연구에서는 라이다에 의한 풍속연직분포 측정 시 샘플링 부피의 구간 평균화 과정에서 발생하는 불확도(uncertainty)를 정량적으로 분석함으로써 라이다에 의한 풍속연직분포 관측의 불확도를 정량평가하고자 한다.

  • PDF

Genotoxicity of Heavy Metals among the Particulates in the Working Environment as Assessed by Tradescantia-Micronucleus (Trad-MCN) Assay (자주달개비 미세핵 분석법을 이용한 작업환경내 총 먼지 중 수용성 추출물의 유전독성 평가)

  • Shin, Hae-Shik;Kim, Jin-Kyu;Lee, Jae-Hwan;Hwang, Kap-Sung;Kim, Kyun;Lee, Jeong-Joo;Lee, Jin-Hong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.639-646
    • /
    • 2003
  • In this study, we evaluated genotoxicity of heavy metals among particulates with Tradescantia-micronucleus (Trad-MCN) assay in the various working environment. In a synthetic fiber factory and a rubber factory, chromium concentration was higher than any other heavy metals. On the other hand, nickel concentration was the highest in a semi-conductor factory. The difference in genotoxicity among the working environment was statistically significant as Trad-MCN frequencies were 4.07 $\pm$0.35 MCN/100 tetrads (p< 0.01) for the synthetic fiber factory,5.73 $\pm$0.81 MCN/100 tetrads (p< 0.01) for the rubber factory, and 15.60$\pm$2.58 (p< 0.01) (p< 0.001) for the semi -conductor factory. As a result, heavy metals among particulates in the working environment can be considered to have hazardous potential to human health, although they cannot directly induce DNA damage to the workers in the working environments.