• Title/Summary/Keyword: 초전센서

Search Result 105, Processing Time 0.034 seconds

Pyroelectric Properties of the $\beta$-PVDF (Poly(vilnylidene fluoride)) Thin Film Prepared by Vacuum Deposition with Applying Electric Field (전계인가 진공 증착법으로 제작된$\beta$ -PVDF (Poly(vinylidene fluoride)) 박막의 초전 특성)

  • Chang, Dong-Hoon;Kang, Seong-Jun;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.23-30
    • /
    • 2002
  • The PVDF (Polyvinylidene Fluoride) thin film having P phase is prepared by the vacuum deposition with applying the electric field and its pyroelectric properties are studied by using a dynamic method to examine the possibility of the application to the pyroelectric IR sensor. The pyroelectric responses of the PVDF thin film are characterized as the frequency dispersion in both low and high modulation frequency regions, and their frequency dependences are observed. In the low frequency region (2~10Hzz), the polarization can easily rotate with the increase of modulation frequency and show the maximum since the reorientation rate of domains is higher than the modulation frequency. On the other hand, in the high frequency region (100~1000Hz), the pyroelectric response decreases as the frequency increases, because the reorienatation rate of domains is suppressed and thus, the change of polarization decreases. Pyroelectric coefficient, figure of merits for noise equivalent power and detectivity of the PVDF thin film are measured as 3.2$\times$10$^{-10}$ C/$\textrm{cm}^2$.K, 2.34$\times$10$^{-10}$ C.cm/J and 1.32$\times$10$^{-9}$ C.cm/J, respectively. Also, the noise equivalent and the detectivity are 1.66$\times$10$^{-7}$ W/H $z^{$\sfrac{1}{2}$}$, 6.03$\times$10$^{5}$ cm.H $z^{$\sfrac{1}{2}$}$W, respectively.

Measurements of Auditory Evoked Neuromagnetic Fields using Superconducting Quantum Interference Devices (SQUID를 이용한 뇌 청각유발 자장의 측정)

  • 이용호;권혁찬;김진목;박용기
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.421-428
    • /
    • 1997
  • Magnetic field sensors made from superconducting quantum interference device (SQUID) are the most sensitive low-frequency sensors available, enabling measurements of extremely weak magnetic fields from the brain. Neuromagnetic measurements allow superior spatial resolution, compared with the present electric measurements, and superior temporal resolution, compared with the fMRl and PET, providing useful informations for the functional diagnoses of the brain. We developed a 4-channel SQUID system for neuromagnetic applications. The main features of the system are its simple readout electronics and compact pickup coil structure. A magnetically shielded room has been constructed for the reduction of environmental magnetic noises. The developed SQUID system has noise level lower than the magnetic noise from the brain. Magnetic field signals of the spontaneous r-rhythm activity and auditory evoked magnetic fields have been measured.

  • PDF

Effect of P(VDF/TrFE) Film Thickness on the Characteristics of Pyroelectric Passive Infrared Ray Sensor for Human Body Detection (P(VDF/TrFE) 필름의 두께에 따른 인체 감지형 초전형 PIR 적외선 센서의 특성)

  • Kwon, Sung-Yeol
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.114-117
    • /
    • 2011
  • A thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated and then thin 1.6 ${\mu}m$ thickness P(VDF/TrFE) film pyroelectric infrared ray sensor has been fabricated also. These thick and thin P(VDF/TrFE) film pyroelectric infrared ray sensor was mounted in TO-5 housing to detect infrared light of 5.5 ~ 14 ${\mu}m$ wavelength for human body detecting with each other. The noise output voltage of the thick P(VDF/TrFE) film pyroelectric infrared ray sensor were 380 mV and NEP(noise equivalent power) is $3.95{\times}10^{-7}$ W which is the similar value with the commercial pyroelectric infrared ray sensor using ceramic materials as a sensing material. The NEP and specific detectivity $D^*$ of the thin P(VDF/TrFE) film pyroelectric infrared ray sensor were $2.13{\times}10^{-8}$ W and $9.37{\times}106$ cm/W under emission energy of 13 ${\mu}W/cm^2$ respectively. These result caused by lower thermal diffusion coefficient of a thin 1.6 ${\mu}m$ thickness PVDF/TrFE film than the thick 25 ${\mu}m$ thickness poled P(VDF/TrFE) film pyroelectric infrared ray sensor.

Superconducting properties of layer-by-layer grown $YBa_{2}Cu_{3}O_{7}$ thin film prepared by pulsed laser deposition (펄스 레이저 증착법으로 layer-by-layer 성장시킨 $YBa_{2}Cu_{3}O_{7}$ 박막의 초전도특성)

  • Kim, In-Seon;Lim, Hae-Ryong;Kim, Dong-Ho;Park, Yon-Ki;Park, Jong-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.61-66
    • /
    • 1998
  • High quality c-axis oriented $YBa_{2}Cu_{3}O_{7}$ films were prepared using the pulsed laser deposition on $SrTiO_{3}$(100) substrate. The atomically smooth $SrTiO_{3}$surface with terraces one unit cell in height could be obtained by a high temperature annealing. $YBa_{2}Cu_{3}O_{7}$ thin films deposited on the substrates exhibited layer-by-layer growth with a c-axis unit cell height. $YBa_{2}Cu_{3}O_{7}$ thin films thus prepared showed critical temperature ${\ge}90$ K with transition width ${\le}0.6$ K, room temperature resistivity of ${\sim}300{\mu}{\Omega}cm$, and critical current density ${\sim}4.6{\times}10^{6}A/cm^{2}$ at 77 K.

  • PDF

Development of PLT($PbLaTiO_{3}$) pyroelectric materials (PLT($PbLaTiO_{3}$) 초전재료 개발(II))

  • Park, Sung-Kun;Bae, Seung-Choon;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.491-499
    • /
    • 1997
  • We fabricated the ceramic PLT tablet which was composed of 5, 10 and 15 mol% lanthanum concentration and thin film PLT to develope pyroelectric materials, and investigated their characteristics. Using TG/DTA, we determined calcination and sintering temperature to sinter the PLT completely and to prevent volatilization of the Pb components. The calcination and sintering temperature were $850^{\circ}C$, $1150^{\circ}C$ respectively, and there was a lot of mass loss at higher sintering temperature. By measuring temperature-dielectric constant characteristics of ceramic tablet we investigated dielectric constant characteristics depends on La concentration. The Curie point of PLT with 5, 10 and 15 mol% lanthanum concentration were $330^{\circ}C$, $269^{\circ}C$ and $210^{\circ}C$ respectively. Using PLT ceramic tablet we observed IR detection characteristics, and then deposited PLT thin film by rf magnetron sputtering. We verified that PLT thin film fabricated with completely sintered PLT target had the same structure to target by investigating lattice constant and optical transparency.

  • PDF

Characteristics of c-axis oriented PLT thin films and their application to IR sensor (c-축 배양된 PLT 박막의 특성 및 IR센서 응용)

  • Choi, B.J.;Park, J.H.;Kim, Y.J.;Kim, K.W.
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.87-92
    • /
    • 1996
  • The PLT thin films on (100) cleaved MgO single crystal substrate have been fabricated by rf magnetron sputtering using a PbO-rich target. The dependence of physical and electrical properties on the degree of c-axis orientation has been studied. The degree of c-axis orientation of PLT thin films depends on fabrication conditions. Fabrication conditions of the PLT thin films were such that substrate temperature, working pressure, gas ratio of $Ar/O_{2}$, and rf power density were $640^{\circ}C$, 10 mTorr, 10 seem, and $1.7\;W/cm^{2}$, respectively. In these conditions, the PLT thin film showed the Pb/Ti ratio of 1/2 at the surface, the resistivity of $8{\times}10^{11}{\Omega}{\cdot}cm$, and dielectric constant of 110. The pyroelectric infrared sensors with these PLT thin films showed the peak to peak voltage of 450 m V and signal to noise ratio of 7.2.

  • PDF

Development of the Wireless Technique for Health Monitoring of Superconducting Motor (초전도 모터의 상태진단을 위한 데이터 신호 무선처리 기법개발)

  • Seo, K.C.;Lee, M.R.;Lee, J.H.;Kwon, Y.K.;Shon, M.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.829-834
    • /
    • 2004
  • This research is to development advanced health(condition) monitoring system of superconducting motors. Development of advanced condition monitoring systems offers the prospect of improved performance, assessment, and operation, simplified design, enhanced safety, and reduced overall cost of advanced and next generation superconducting motor. For advanced and next generation superconducting motor design, the opportunity exists to develop and implement real-time and continuous monitoring systems by integrating wireless and computational technique. Generally, condition monitoring and control of temperature is essential for managing the superconducting motor components, rotor and structures. In this research, development of advanced monitoring in low temperature and high speed operating environments offers the potential to greatly improve the control of harsh environments. In conventional method, slip rings have been used to acquire data from these sensors. However, the increase of sensors leads to vibration of the rotation axis and noise signals due to kinematics contact. In this study, the wireless data acquisition technique was employed to develop more stable monitoring system adequate for high speed rotating system.

  • PDF

Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System (저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작)

  • Kim I. S;Yu K. K;Park Y. K
    • Progress in Superconductivity
    • /
    • v.6 no.1
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF

Nondestructive Evaluation System using SQUID in Magnetically Un-shielded Environment (비자기 차폐 환경에서의 SQUID를 이용한 비파괴 평가 시스템에 대한 연구)

  • Chung, Soon-Hee;Hwang, Yun-Seok;Choi, Hee-Seok;Kim, Jin-Tae;Lim, Hae-Ryong;Kim, In-Seon;Kwon, Hyuk-Chan;Park, Yong-Ki;Park, Jong-Chul;Lee, Soon-Gul;Lee, Dong-Hoon;Kim, Dong-Ho
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.54-57
    • /
    • 1999
  • 본 연구에서는 SQUID를 이용한 비파괴 평가 시스템을 제작, 측정하였다. 이 시스템은 비자기 차폐 환경에서 작동할 수 있도록 설계하였고, 측정 자기 센서로는 dc 및 rf-SQUID gradiometer를 사용하였다. 비자기 차폐 환경에서 ${\sim}$nT의 미세 자기 신호를 검출하였고, 공간적으로 변화하는 외부 자기 신호를 측정, 분석하였다. 또한, 측정된 자기 신호를 통해 dc-SQUID와 rf-SQUID에 대한 비교를 했다.

  • PDF

Development of Superconducting Transition Edge Sensors for Gamma Ray Detection (감마선 검출을 위한 초전도 상전이 센서)

  • Lee, Young-Hwa;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.9 no.2
    • /
    • pp.162-166
    • /
    • 2008
  • We are developing a sensitive gamma ray spectrometer based on superconducting transition edge sensors. The detector consists of a small piece of high purity Sn as an absorber and a Ti/Au bilayer as a temperature sensor. It is designed to measure the thermal signal caused by absorption of gamma rays. The mechanical support and the thermal contact between the absorber and the thermometer were made with Stycast epoxy. The bilayer was formed by e-beam evaporation and patterned by wet etching on top of a $SiN_X$ membrane. A sharp superconducting transition of the film was measured near 100 mK. When the film was biased to the edge of the transition, signals were observed due to single photon absorption emitted from an $^{241}Am$ source. The measured spectrum showed several characteristic peaks of the source including 59.5 keV gamma line. The full with at half maximum was about 900 eV for the 59.5 keV gamma line. The background was low enough to resolve low energy lines. Considerations to improve the energy resolution of the gamma ray spectrometer are also discussed.

  • PDF