• Title/Summary/Keyword: 초음파 측정 시스템

Search Result 334, Processing Time 0.031 seconds

Improved Localization Algorithm for Ultrasonic Satellite System (초음파위성시스템을 위한 개선된 위치추정 알고리즘)

  • Yoon, Kang-Sup
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.775-781
    • /
    • 2011
  • For the measurement of absolute position of mobile robot in indoor environments, the ultrasonic positioning systems using ultrasound have been researched for several years. Most of these ultrasonic positioning systems to avoid interference between the ultrasound are used for sequential transmitting. However, due to the use of sequential transmitting, the positions of transmitter to receive an ultrasound will change when the mobile robot moves. Therefore the accuracy of positioning is reduced. In this paper, the new position estimation algorithm with weighting factor according to the time of receipt is proposed. By applying the proposed algorithm to existing Ultrasonic Satellite System(USAT), the improved USAT is configured. The positioning performance of the improved USAT with the proposed position estimation algorithm are verified by experiments.

Development of real-time continuous suspended sediment concentration measurement system using acoustic backscatter of H-ADCP (실시간 부유사농도 측정을 위한 횡방향 초음파도플러유속계의 초음파산란도를 활용한 부유사농도 측정 시스템 개발)

  • Son, Geunsoo;Roh, Youngsin;Kim, Dongsu;Choi, Kwangtae;Chung, Hokun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.23-23
    • /
    • 2022
  • 하천의 유량 및 유사량 자료는 하천에서 발생하는 다양한 문제를 분석하기 위한 기초자료로 지속적인 모니터링을 통한 측정자료의 생산이 필요하다. 따라서, 국내에서는 지속적인 유량 측정을 목적으로 전국의 주요 국가하천을 대상으로 약 62개소에서 H-ADCP를 활용하여 지속적인 유량측정을 수행하고 있다. 이때, H-ADCP는 유량을 측정하기 위한 유속자료와 함께 초음파산란도 자료를 부가적으로 제공하고 있어 초음파산란도를 부유사농도의 지표로 활용하여 지속적인 부유사농도를 측정하기 위한 연구가 수행되고 있으며, 기존에 설치된 자동유량관측소의 H-ADCP를 통해서 실시간의 유량자료와 함께 유사량 자료를 제공할 수 있을 것으로 기대되고 있다. 이에 본 연구에서는 자동유량관측소를 대상으로 과거 유사량 측정을 수행한 5개 지점을 선정하여 초음파산란도를 활용한 부유사농도 측정 기술의 적용성을 검토하였고, 이를 통해 제시한 부유사농도 측정 방법을 통해 실시간 부유사농도 측정 시스템을 개발하였다. 그리고 실시간 부유사농도 측정 시스템의 적용성을 검토하기 위해 나주시(남평교) 자동유량관측소 지점에 시스템을 구축하여 초음파기반의 부유사농도 측정 기술을 통한 실시간 부유사농도 산정 방법에 대한 보완 사항과 개선방향을 도출하고자 하였다.

  • PDF

Discharge Measurement by Ultrasonic Discharge Measurement System (초음파 유량측정 시스템에 의한 유량측정)

  • Kim, Chi Young;Yoon, Gwang Suk;Kim, Dong Gu;Kim, Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1198-1202
    • /
    • 2004
  • 초음파를 이용한 측정은 하천의 반대편에 흐름방향에 경사지게 초음파를 발사하여 다시 반사되어 오는 시간차를 기록함으로써 주어진 길이에서 유속을 연속적으로 측정하는 것이다. 하류로 내려가는 음파는 음향 측선(acoustic path)과 평행한 유속 성분 때문에 상류로 올라가는 음파보다 빠른 속도를 가진다. 탄천 및 괴산댐에 초음파 유량 측정시스템을 시험 설치하고 운영 결과를 검토하였다. 시험적용결과 연속적인 유량자료 획득이 가능하였으며, 기존 유속면적법 대비 $4.21\%$의 상대오차를 지니고 있어 기존 방법과 비교적 일치하는 측정결과를 나타냈다. 또한 지표유속(Index Velocity)를 활용한 단일회선 유량산정법을 검토한 결과, 다회선에 의해 운영한 결과와 평균 $2.9\%$의 상대오차를 지니고 있었다. 이 방법은 조석구간 및 배수영향을 받는 구간에서 작은 비용으로 연속유량자료를 획득할 수 있는 방법으로 판단된다. 시험적용 결과 개선해야 할 사항으로는 안정적인 자료 획득을 위한 초음파 변환기의 개선, 자료의 필터링 기술의 정밀화, 그리고 유량산정 방법에서 정확도 향상 기술 개발 등이 도출되었다. 초음파 유량 측정시스템은 자료의 연속성을 확보할 수 있는 점에서 매우 중요한 의미를 지니고 있다. 지금까지의 연속 유량 산출법은 연속적인 수위를 측정하고 각 수위에 따른 유량 측정 후 수위-유량관계를 통하여 연속적인 유량을 산출하였다. 그러나 초음파 유량 측정 시스템은 직접 유속과 수위를 측정하여 연속유량이 산출되기 때문에 연속유량 산출에 비교적 간편하다고 할 수 있다. 또한 정확도 면에서 기존 유량 측정법인 유속-면적법의 불확실도 $5\%\~10\%$에 비교하여 $5\%$ 내외의 정확도 수준을 지니고 있어 정확도 향상을 기대할 수 있다. 경제적인 측면에서도 매년 측정사업에 소요되는 비용과 비교하였을 때 장기적으로는 경제적인 방법이 될 수 있다.

  • PDF

The Implementation of TMM test phantom for evaluating the thermal performance in High Intensity Focused Ultrasound system (강력 집속 초음파 시스템의 열적 성능 평가를 위한 팬텀 개발에 관한 기초연구)

  • Yu, Woo-Jin;Noh, Si-Cheol;Park, Moon-Kyu;Min, Hae-Ki;Park, Jae-Hyun;Choi, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.484-485
    • /
    • 2008
  • 초음파는 의학적 진단 및 치료의 목적으로 널리 사용되어 왔다. 일반적으로, 초음파 조사의 생물학적 무해성은 많은 연구를 통하여 보고되었으나, 최근 초음파 집속을 통한 강력 초음파의 사용에 대한 열적 안전성 평가가 중요한 요소로 대두되고 있다. 이에 본 연구에서는 강력 집속 초음파의 전달 에너지와 열적 분포를 측정하여 안전성 평가에 활용 가능한 초음파 열분포 팬텀을 제안하였다. 온도 분포 측정용 팬텀은 초음파 조직유사 팬텀 재료인 한천을 이용하였으며, 음향학적 특성의 유사성을 평가하였다. 온도 효과를 측정하기 위하여 $3{\times}3$의 형태로 온도 센서를 팬텀 내부에 배열하여 초음파 조사에 따른 온도 분포를 측정하였고 온도 측정을 위한 시스템을 개발하여, 초음파 가열 실험을 수행하였다. 본 연구에서 제안된 초음파 온도 분포 측정용 팬텀의 유용성을 확인하였으며, 온도 분포용 팬텀을 통한 강력 집속 초음파 장비의 열적 성능 평가에 적용 될 수 있을 것으로 사료되었다.

  • PDF

Development of a Laser-Generated Ultrasonic Inspection System by Using Adaptive Error Correction and Dynamic Stabilizer (적응적 에러 보정과 다이나믹 안정기를 이용한 레이저 유도 초음파 검사 시스템 개발)

  • Park, Seung-Kyu;Baik, Sung-Hoon;Park, Moon-Cheol;Lim, Chang-Hwan;Ra, Sung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.391-399
    • /
    • 2005
  • Laser-generated ultrasonic inspection system is a non-contact scanning inspection device with high spatial resolution and wide bandwidth. The amplitude of laser-generated ultrasound is varied according to the energy of pulse laser and the surface conditions of an object where the CW measuring laser beam is pointing. In this paper, we correct the generating errors by measuring the energy of pulse laser beam and correct the measuring errors by extracting the gain information of laser interferometer at each time. h dynamic stabilizer is developed to stably scan on the surface of an object for an laser-generated ultrasonic inspection system. The developed system generates ultrasound after adaptively finding the maximum gain time of an laser interferometer and processes the signal in real time after digitization with high speed. In this paper, we describe hardware configuration and control algorithm to build a stable laser-generated ultrasonic inspection system. Also, we confirmed through experiments that the proposed correction method for the generating errors and measuring errors is effective to improve the performance of a system.

Precision Measurement of Ultrasonic Power the Milliwatt Range (밀리와트 영역의 초음파 파워 정밀 측정)

  • Jho, Moon-Jae;Hwang, Cheol-Ho;Suh, Sang-Joon;Cha, Il-Whan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.25-33
    • /
    • 1990
  • An ultrasonic power measurement system in milliwatt range was constructed. The ultrasonic power can be determined by measuring the radiation pressure on a target using self-compensating microbalance. Measurement was performed using a perfect reflector and a perfect absorber. In order to check the feasibility of the system, the ultrasonic power for the two targets was measured. Also, the systematic measurement errors and the reproducibility were examined. The relative error between two targets is proved to be within 2%. Also when the ultrasonic power range is larger than 10mW, the standard deviation for repeated measurement becomes smaller than ${\pm}$2%.

  • PDF

Development of experimental water level measuring device using an Arduino and an ultrasonic sensor (아두이노와 초음파 센서를 이용한 실험용 수위 측정 장치 개발)

  • Yoo, Moonsung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.143-147
    • /
    • 2018
  • Water levels are measured in various fields such as sewage treatment plants, water treatment plants, rivers, dams, factory storages' tanks. Ultrasonic instruments for water level measurement are expensive and are used for industrial field. Rapid advances in electronics have made it possible to build a wide variety of measurement, monitoring and control functions at low cost. This study was started to make ultrasonic level measurement system at low price. The system was constructed with an Arduino, an ultrasonic sensor and a temperature sensor for use in the experiment. The ultrasonic sensor measures the time from the sensor to the liquid surface. The temperature sensor measures the atmospheric temperature and improves the accuracy of the ultrasonic distance measurement by correcting the sound speed. Arduino controls measurements and calculates the water level. All components of the system are assembled into a device holder. Experiments with this system show that the water level measured by the system is very close to the actual value. This system is also inexpensive and easy to install and maintain, making it suitable for laboratory use.

A Study on Ultrasonic Nonlinear Parameter B/A Measuring System Developement Using PVDF Piezoelectric Film (PVDF 압전박막을 이용한 초음파 비선형 파라메타 B/A 측정 시스템의 개발)

  • 김정구
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.47-52
    • /
    • 1997
  • PVDF 고분자 압전 초츰파 변환기를 이용하여 초음파 비선형 파라케타 B/A 측정 시스템을 제작하였다. 이 측정 시스템은 종래의 비선형 파라메타 B/A측정 시스템에 있어 문제점이었던 장치의 복잡성을 대폭 간랸화할 수있으며 고차 고조파까지도 측정할 수 있는 장점이 있다. 이러한 장치를 이용하여 여러 가지 물질에 대한 B/A를 측정한 결과 다른 문헌치와 잘 일치하였다.

  • PDF

A Study about Measurement Method for Quantitative Classification of Breeding Pig's Locomotor Behaviors using Ultrasonic Sensor Array (초음파 센서 어레이를 이용한 모돈 지제이상 정량분석 방법 연구)

  • Cho, Jinho;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.163-163
    • /
    • 2017
  • 모돈은 교배, 임신, 분만, 포유, 이유를 순환적 반복을 요구하는 개체로서 스마트 농장 시스템의 생산성 향상에 있어서 중요한 요소이다. 본 연구에서는 모돈 능력의 극대화 및 최적의 시스템 관리를 위해서 초음파 센서를 활용한 모돈의 지제 이상 징후를 실시간으로 계측할 수 있는 시스템을 개발하였다. 이 시스템은 높이에 따라 상-중-하(30 cm 간격), 위치에 따라 전면부-후면부에 초음파 센서를 설치하고 이를 마이크로 컨트롤러에 연결하여 모돈의 지제 이상 유무 측정이 가능하도록 하였다. 모돈의 체형과 위치를 고려하여 설치된 초음파 센서의 위치 조절이 가능하도록 하였다. 또한 소형 LCD 모듈을 내장하여 실시간 모니터링이 가능하도록 하였으며, 측정된 데이터는 저장장치인 microSD 카드에 저장되도록 하였다. 모돈사의 환경을 고려하여 방밀형 구조로 하우징 마감하였다. 이 모돈 지체 이상 분석 시스템에 사용된 툴은 C언어를 이용하였다. 건강한 모돈을 대상으로 모돈의 지제의 관찰을 위하여 총 12회의 현장 실증실험이 수행되었으며, 현장 실증 시험 중 소요된 시간은 현장의 상황에 따라 다소 상이하였다 (8시간-28일). 높이 상에 위치한 전면부 및 후면부 초음파 센서 모두에서 모돈이 검출이 된 경우 정상 기립으로 간주하였고, 높이 상에 위치한 전면-후면부 초음파 센서 모두에서 모돈이 검출이 되지 않은 경우 정상적으로 누워 있는 걸로 간주하였다. 높이 하에 위치한 전면부 혹은 후면부 초음파 센서 한곳만 모돈이 검출된 경우 비정상적인 기립으로 간주하였다. 취득된 데이터를 분석한 결과 모돈의 정상적 상태 (기립상태, 누운 상태, 앉은 상태)와 그 외의 비정상적 상태로 분류가 가능하다. 또한 측정된 초음파 센서의 진동의 유무 및 파동형태에 따라서 모돈의 상태 예측이 가능하다. 초음파 센서의 진동 파동이 크고 안정된 상태인 경우 정상적인 활동 상태로 판단하였으며, 진동 파동이 작고 안정적인 경우는 수면 상태로 분류하였다. 실시간으로 지속적인 데이터 획득을 위하여 차후 초음파 센서 및 시스템의 보완작업이 필요하다. 이와같은 모돈의 행동 패턴에 따른 취득된 데이터를 분류하여 모돈의 발정에 의한 행동 특성(기립시간) 분석에 따른 발정 적기 발견 및 정량화 기술 개발에 활용이 가능하다.

  • PDF

Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers (접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향)

  • Choi, Ik-Hwang;Lee, Jae-Ik;Kwon, Goo-Do;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.358-363
    • /
    • 2008
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Thus, in this study, we investigate the effects of such experimental system dependent factors in the measurement of ultrasonic nonlinear parameter by using contact PZT transducer. Experimental results showed that the effect of system dependent nonlinearity is reduced when the contact pressure and transducer input voltage are sufficiently large. These results will be very useful to find out the proper experiment condition to measure rather accurate nonlinear parameter.